3B Scientific Teltron Tube Holder D User Manual

3B SCIENTIFIC
07/12 ALF
®
PHYSICS
Tube Holder D 1008507
1 Base plate 2 Holes for inserting Helm-
holtz coils 3 Stanchion 4 Clamping jaws for tubes 5 Retaining slider 6 Fork 7 Stock for tubes and opti-
cal analogue equipment

1. Safety instructions

When operating tubes, the terminals may be live to high voltages that are dangerous to touch.
Do not modify circuits unless all power sup-
plies are turned off.
Do not mount or remove tubes unless all
power supplies are turned off.

2. Description

The tube holder accommodates all tubes of the series D and their accessories, such as the Helmholtz Coils D (100644) and Auxiliary Coil (100645) plus the Optical Analogue equipment (1000656).
The tube holder consists of a robust base plate with an upright stanchion and a fork-shaped holder for hot cathode tubes that can be rotated by 360° and is made of heat-resistant, highly insulating plastic. The tubes are secured into sprung clamps with retaining sliders. Two holes are bored in the base plate to accommodate a pair of Helmholtz coils at the “Helmholtz separa­tion distance” for generating a uniform magnetic field. The tube holder rests on three non-slip rubber feet.
1

3. Technical data

Dimensions: 230x175x320 mm3 approx. Separation of
holes for coils: 76 mm approx. Weight: 1.5 kg approx.

4. Operation

4.1 Setting up and removing hot cathode tubes

Tubes should not be mounted or removed
unless all power supplies are disconnected.
Push the jaw clamp sliders on the stanchion
of the tube holder right back so that the jaws open.
Push the bosses of the tube into the jaws. Push the jaw clamps forward on the stan-
chions to secure the tube within the jaws.
To remove the tube, push the jaw clamps
right back again and take the tube out of the jaws.

4.2 Setting up the Helmholtz coils D (100644)

Place the tube in the holder as described
above.
Insert the Helmholtz tubes into the holes
with the connections facing outwards. Push the sleeves on the rod upwards and insert the rod at an angle.
Push the sleeves into the holes to secure
the coils.

4.3 Setting up the auxiliary coil (1000645)

Place the coil on the upper fork. Push the retaining slider over the lip of the
auxiliary coil to secure the coil in place.
4.4 Setting up the optical analogue equip­ment (1
Insert the aluminium disc with the grating
000656)
into the stanchion from behind.
-
-
Fig. 1 Setting up a tube (left), a tube, the Helmholtz coils and the auxiliary coil (right)
3B Scientific GmbH • Rudorffweg 8 • 21031 Hamburg • Germany • www.3bscientific.com
Subject to technical amendments
© Copyright 2012 3B Scientific GmbH
Loading...