3B Scientific D 900 User Manual

3B SCIENTIFIC
Low Voltage Coil D 1000985
Coil D, 600 turns 1000988 Coil D, 900 turns 1012859
Coil D, 6000 turns 1000990
Instruction sheet
06/12 ALF
®
PHYSICS
1. Safety instructions
The coils conform to the safety regulations for elec­trical test, control and laboratory equipment as specified in DIN EN 61010 Part 1. They are in­tended for use in dry rooms suitable for electrical equipment or installations.
Safe operation of the coils is guaranteed, pro­vided they are used correctly. However, there is no guarantee of safety if the coils are used in an improper or careless manner.
If it is deemed that the coils can no longer be
operated without risk (e.g. visible damage has occurred), the coils should be switched off imme­diately and secured against any inadvertent use.
In schools and training institutions, operation of the coils is to be responsibly supervised by trained personnel.
Depending on the set-up of the transformer, it may be possible to come into contact with dangerous voltages at the secondary coil.
1
Coils 1000988, 1012859, 1000989, 1000990 can be subject to high or low voltages when used as secondary coils. They are not suitable for
experiments performed by students.
Eingriffe in den Aufbau eines Transforma-
tors nur bei abgeschalteter Primärspannung vornehmen.
Always use safety cables for experiments.
Do not exceed the maximum voltage over
any length of time.
Do not open the coils’ cases.
Do not allow the equipment to come into
contact with liquids.
If the coils should become overloaded, they
must be allowed to cool before switching on the current again.
Do not cover the air vents.
The resulting magnetic fields can cause damage to or even destroy electrical/electronic compo­nents and equipment or electromagnetic storage media. Such items must be kept away from the coil by at least the amount specified for safety.
2. Description
Coils, safe to touch, for use as primary or sec­ondary coils in combination with the transformer core D (1000976).
Coils with a variety of winding turns and interme­diate taps. A suitable choice of coil enables all experiments to be performed safely at low volt­age. Simple whole-number winding and interme­diate tap ratios allow the transformer laws to be derived in clear and understandable fashion.
Coils are made of impact-resistant plastic. The ends and taps for the coils are equipped with safety sockets. Number of turns, maximum cur­rent for long-term operation, effective resistance, direction of windings and inductance are speci­fied on the case of the coil. The current may reach approximately double the long-term ma­ximum for short periods (10 seconds).
1000985 1000988 1012859 1000989 1000990
Winding turns Tap(s) Resistance Max. current Inductance
72 6/30/54/66/72 0,1 Ohm 12 A 0.23 mH
600 200/600 3 Ohm 2.2 A 15 mH
900 4.8 Ohm 5 A (7 min) 34 mH
1200 400/1200 12 Ohm 1.2 A 60 mH
6000 2000/6000 300 Ohm 0.2 A 1.5 H
The coil with 900 windings has a reversible tem­perature cut-out inside, which trips when the winding temperature reaches 85°C. It resets after about 10-20 minutes depending on the ambient temperature.
3. Accessories
Mains coil D with connecting lead (230 V, 50/60 Hz) 1000987 or Mains coil D with connecting lead (115 V, 50/60 Hz) 1000986
Transformer core D 1000976
4. Care and maintenance
Before cleaning the coil, disconnect it from
its power supply.
Use a soft, damp cloth to clean it.
5. Disposal
The packaging should be disposed of at
local recycling points.
Should you need to dispose of the coil itself,
never throw it away in normal domestic waste. Local regulations for the disposal of electrical equipment will apply.
6. Technical data
Connections:: 4-mm safety sockets Dimensions: 120 x 90 x 70 mm Opening for iron core: 42 x 42 mm
3
2
Elwe Didactic GmbH Steinfelsstr. 5 08248 Klingenthal Germany www.elwedidactic.com
3B Scientific GmbH Rudorffweg 8 21031 Hamburg Germany www.3bscientific.com
Rights to amend technical specification reserved
© Copyright 2012 3B Scientific GmbH