3B Scientific CPR Lilly Pro User Manual

0 (0)

CPRLillyP70/1 (1017774)

CPRLillyProP71/1 (1017775)

CPRLillyP70 (1017772)

CPRLillyProP71 (1017773)

CPRLilly(P70) und CPRLillyPRO(P71)

Contents

Introduction

3

Delivery contents

3

Quick introduction

4

Assembly, start-up and use

5

Simulations

6

Medical procedures

14

General safety instructions

16

FAQ

16

Maintenance and care

17

Replacement parts list

18

Technical data

19

P70

P70/1

P71

P71/1

2

Introduction

Thank you for choosing this 3B Scientific® product. Please read the operating instructions carefully before setting up the device. This will ensure that it works correctly, and that you can work satisfactorily with this product. You can register your simulator at www.3Bscientific.com.

CPRLilly™ and CPRLillyPRO™ are training simulators for cardio-pulmonary resuscitation (CPR). The simulator meets the latest CPR guidelines of the AHA (American Heart Association) and the ERC (European Resuscitation Council). The simulator has a robust construction, is easy to use and offers realistic working scenarios. It is therefore suitable both for medical training and for first aid courses in schools and associations. It offers all the necessary features for learning about the life-saving algorithm comprising heart massage and artificial respiration for adults. Its features are:

Torso with shoulders and the necessary anatomical features for finding the ideal pressure point for cardiac massage

Head with airways for mouth-to-mouth and mouth-to-nose resuscitation

Head tilt to open the airways

Resuscitator ventilation is possible

Realistic thoracic spring force and the required compression depth of 5 cm prepare the trainee for a situation with a real person

A sound indicates that the required compression depth has been reached

Thanks to the disposable respiration bags the mannequin is hygienic, and is easy to clean and maintain

CPRLilly™ and CPRLillyPRO™ have two respiratory systems that are disconnected from each other. The advantage: the user‘s breath goes into the disposable throat bag only. The inner circulation is not contaminated.

CPRLilly™ and CPRLillyPRO™ are developed and made in Germany.

While developing CPRLilly™ and CPRLillyPRO™, we paid special attention to creating a simulator that would be quick and easy to use, especially with regard to hygiene and for large training groups. The face mask is dish-washer safe and replacements can be bought. For maximum hygiene you can provide each course participant with his or her own mask and disposable throat bag.

Delivery contents:

CPRLilly™ (P70) and CPRLillyPRO™ (P71) each comprise 1 simulator 5 Lower face masks (including teeth)

25 Throat bags

1 Carry case

1 Disinfectant

1 Tracksuit top

1 Android tablet PC (version P71)

1 Plug adaptor for the charger (version P71)

1 Charger (version P71)

3

3B Scientific CPR Lilly Pro User Manual

Quick Introduction

4

Assembly (start-up and use)

Instructions (safety and general information)

Fully charge the CPRLillyPRO™ and the Android tablet using the power pack provided before using it for the first time! For the CPRLillyPRO™ this may take up to 3 hours. While on charge, the LED indicator will fl ash orange quickly. When the LED fl ashes orange slowly, the battery is fully charged. (Version P71)

To avoid getting moisture into the inner circulation, respiration may only be carried out when a throat bag has been inserted.

The throat bag should not be changed in the rain, because water could get into the inner circulation. The CPRLilly™ and CPRLillyPRO™ could get damaged

When being used, „noises“ will be heard (version P71).

This does not mean that the simulator is not working properly!

Assembly / Installation

• Removing the face mask

• Putting in a new bag

• Attaching a face mask

• Disinfecting the face mask

5

Power supply (Version P71)

The CPRLillyPRO™ is powered via the small-device 15 Volt socket. CPRLillyPRO™ comes with a multinational mains adaptor for use in over 150 countries. It can operate between 100 and 240 Volts and at a mains frequency of 50 or 60 Hz. We recommend always charging the CPRLillyPRO™ with the supplied mains adaptor included.

Changing/charging the battery Doing a course with a flat battery

Even if the battery is flat, you can still do your course! Simply connect the mains adaptor to the CPRLillyPRO™.

Extended period of non-use

If the device is not used for an extended period of time, ensure that CPRLillyPRO™ is charged at least every two years, so that the battery is not damaged by becoming completely discharged.

If you intend to not use the device for an extended period, charge the battery up completely until the LED flashes orange slowly.

Changing the battery

The CPRLillyPRO™ has a very long-life NiMH battery that only discharges very slowly. It should only be changed by a specialist or an authorised electrician. You can order a replacement battery from the accessory list if necessary. The instructions for inserting the new battery are provided with the battery. If the LED flashes red, either a battery defect has been detected, or the connected charger is not powerful enough.

If the LED is flashing red, but you are using the original mains adaptor, please contact the customer service.

Simulations

Switching the device on/off (Version P71)

1. Switching on the device

The electronics inside the CPRLilly™ automatically switch off after 5 minutes of inactivity, or the device can be switched off manually by holding down the on/off button.

6

Loading...
+ 13 hidden pages