ZTE RSU82C Users Manual

Page 1
ZXSDRRSU82C
RadioSystemUnitofCDMAwith2T4R
UserManual
Version:1.00
ZTECORPORATION NO.55,Hi-techRoadSouth,ShenZhen,P .R.China Postcode:518057 Tel:+86-755-26771900 Fax:+86-755-26770801 URL:http://ensupport.zte.com.cn E-mail:support@zte.com.cn
Page 2
LEGALINFORMATION
Copyright©2011ZTECORPORA TION.
Thecontentsofthisdocumentareprotectedbycopyrightlawsandinternationaltreaties.Anyreproductionor
distributionofthisdocumentoranyportionofthisdocument,inanyformbyanymeans,withoutthepriorwritten
consentofZTECORPORATIONisprohibited.Additionally,thecontentsofthisdocumentareprotectedby
contractualcondentialityobligations.
Allcompany,brandandproductnamesaretradeorservicemarks,orregisteredtradeorservicemarks,ofZTE
CORPORATIONoroftheirrespectiveowners.
Thisdocumentisprovided“asis”,andallexpress,implied,orstatutorywarranties,representationsorconditions
aredisclaimed,includingwithoutlimitationanyimpliedwarrantyofmerchantability,tnessforaparticularpurpose,
titleornon-infringement.ZTECORPORATIONanditslicensorsshallnotbeliablefordamagesresultingfromthe
useoforrelianceontheinformationcontainedherein.
ZTECORPORA TIONoritslicensorsmayhavecurrentorpendingintellectualpropertyrightsorapplications
coveringthesubjectmatterofthisdocument.ExceptasexpresslyprovidedinanywrittenlicensebetweenZTE
CORPORATIONanditslicensee,theuserofthisdocumentshallnotacquireanylicensetothesubjectmatter
herein.
ZTECORPORA TIONreservestherighttoupgradeormaketechnicalchangetothisproductwithoutfurthernotice.
UsersmayvisitZTEtechnicalsupportwebsitehttp://ensupport.zte.com.cntoinquirerelatedinformation.
TheultimaterighttointerpretthisproductresidesinZTECORPORATION.
RevisionHistory
RevisionNo.RevisionDateRevisionReason
R1.025/10/2010FirstEdion
R1.125/12/2010ModifyRFandPowerIndices
R1.208/08/2011AddthenotesofthetypicallossoftheRFcable
SerialNumber:SJ-20101019140047-001(R1.2)
PublishingDate:08/08/201 1
Page 3

FCC&ICSTATEMENT

ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowing twoconditions:(1)thisdevicemaynotcauseharmfulinterference,and(2)thisdevice mustacceptanyinterferencereceived,includinginterferencethatmaycauseundesired operation.
Note:
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassAdigital device,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovide reasonableprotectionagainstharmfulinterferencewhentheequipmentisoperatedin acommercialenvironment.Thisequipmentgenerates,uses,andcanradiateradio frequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructionmanual, maycauseharmfulinterferencetoradiocommunications.
Operationofthisequipmentinaresidentialareaislikelytocauseharmfulinterferencein whichcasetheuserwillberequiredtocorrecttheinterferenceathisownexpense.
I
Page 4
II
Page 5

FCCRadiationExposure Statement

ThisequipmentcomplieswithFCCradiationexposurelimitssetforthforanuncontrolled environment.Thisequipmentshouldbeinstalledandoperatedwithminimumdistance4m betweentheradiator&yourbody.
I
Page 6
II
Page 7

DeclarationofRoHS Compliance

Tominimizetheenvironmentalimpactandtakemoreresponsibilitytotheearthwelive, thisdocumentshallserveasformaldeclarationthatZXSDRRSU82Cmanufacturedby ZTECORPORATIONareincompliancewiththeDirective2002/95/ECoftheEuropean Parliament-RoHS(RestrictionofHazardousSubstances)withrespecttothefollowing substances:
lLead(Pb) lMercury(Hg) lCadmium(Cd) lHexavalentChromium(Cr(VI)) lPolyBrominatedBiphenyls(PBB’s) lPolyBrominatedDiphenylEthers(PBDE’s)
TheZXSDRRSU82CmanufacturedbyZTECORPORATIONmeettherequirementsofEU
2002/95/EC;however,someassembliesarecustomizedtoclientspecications.Additionof
specialized,customer-speciedmaterialsorprocesseswhichdonotmeettherequirementsof
EU2002/95/ECmaynegateRoHScomplianceoftheassembly.T oguaranteecomplianceofthe
assembly,theneedforcompliantproductmustbecommunicatedtoZTECORPORATIONinwritten
form.Thisdeclarationisissuedbasedonourcurrentlevelofknowledge.Sinceconditionsofuseare
outsideourcontrol,ZTECORPORATIONmakesnowarranties,expressorimplied,andassumesno
liabilityinconnectionwiththeuseofthisinformation.
I
Page 8
II
Page 9
Chapter1
SafetyDescription
TableofContents
SafetySpecicationsGuide........................................................................................1-1
SafetySymbols..........................................................................................................1-2
SafetyInstructions......................................................................................................1-3

1.1SafetySpecificationsGuide

Thesesafetyinstructionsmustbeconsideredassupplementaryforlocalsafety regulations.Theprioritymustbegiventolocalsafetyregulationsifthereisanyconict betweenthetwo.
Themaintenancepersonnelmusthavetheknowledgeofsafetyoperationsand maintenancewithrequiredqualicationandtechnicalbackground.
Warning!
Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowing twoconditions:
lThisdevicemaynotcauseharmfulinterference. lThisdevicemustacceptanyinterferencereceived,includinginterferencethatmay
causeundesiredoperation.
Changesormodicationsnotexpresslyapprovedbythepartyresponsibleforcompliance couldvoidtheuser'sauthoritytooperatetheequipment.
TheequipmentisintendedforinstallationinRESTRICTEDACCESSLOCA TIONS.
Alltheoperationandmaintenancepersonnelmustfollowthesafetyprecautionsand instructionsprovidedbyZTECorporationtoavoidanyaccident.
Note:
ZTECorporationdoesnotbearanyliabilitiesincurredbecauseofviolationofthe universalsafetyoperationrequirements,orviolationofsafetystandardsfordesigning, manufacturingandusingtheequipment.
1-1
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 10
ZXSDRRSU82CUserManual

1.2SafetySymbols

Table1-1listssafetysymbols.Theyaretoprompttheuserofthesafetyprecautionstobe
observedduringZXSDRRSU82Coperationandmaintenance.
Table1-1SafetySymbolsDescription
SafetySymbolsMeaning
Nosmoking:Smokingisforbidden
Noammables:Noammablescanbestored.
Notouching:Donottouch.
Universalalertingsymbol:Generalsafetyattentions.
Electricshock:Riskofelectricshock.
Electrostatic:Thedevicemaybesensitivetostaticelectricity .
Microwave:Bewareofstrongelectromagneticeld.
Laser:Bewareofstronglaserbeam.
Scald:Bewareofscald.
Amongstthesesafetysymbols,theuniversalalarmsymbolsareclassiedintothreelevels: danger,warning,andcaution.Theformatsandmeaningsofthethreelevelsaredescribed asbelow:
Danger!
Indicatesapotentiallyhazardoussituationwhich,ifnotavoided,willresultindeathor seriousinjuryofpeople,orequipmentdamagesandbreakdown.
1-2
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 11
Warning!
Indicatesapotentiallyhazardoussituationwhich,ifnotavoided,couldresultindeathor seriousinjury.
Caution!
Indicatesapotentiallyhazardoussituationwhich,ifnotavoided,couldresultinserious injuries,equipmentdamagesorinterruptionofpartservices.

1.3SafetyInstructions

Thissectiondescribesthesafetyinstructionsrelatedtoelectricalsafety,antistatic,heavy objectsandmodules.
Chapter1SafetyDescription
ElectricalSafetyInstructions
Thefollowingaretheelectricalsafetyinstructionsabouttools,highvoltage,powercables, holesandlightning:
lTools
Usespecialtoolsratherthancommontoolsforhigh-voltageandACoperations.
lHighVoltage
Danger!
Highvoltageishazardous.Directorindirectcontactwithhighvoltageormainsupply usingawetobjectcouldresultindeath.
àStrictlyfollowlocalsafetyrulestoinstallACpowerdevices.
àInstallationstaffmustbequaliedforperforminghigh-voltageandACoperations.
àDonotwearanywatch,handchain,bracelet,ringoranyotherconductiveobjects
duringsuchoperations.
àPreventmoisturefromaccumulatingontheequipmentduringoperationsina
dampenvironment.
lPowerCable
1-3
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 12
ZXSDRRSU82CUserManual
lDrillingHoles
Warning!
Neverinstalloruninstallpowercableswhiletheyarelive.Otherwise,thepowercable, whencontactingaconductor,mayresultinsparksorelectricarccausingareoreven damagetoeyes.
àMakesureofshuttingoffpowersupplybeforeinstallingordisconnectingapower
cable.
àBeforeconnectingthepowercable,makesurethattheconnectingcableandits
labelareappropriatefortheactualinstallationrequirements.
Warning!
Itisnotallowedtodrillchassisholeswithoutpermission.
àUnqualieddrillingcoulddamagewiringandcablesinsidethechassis.
Additionally,metalpiecesinsidethechassiscreatedbythedrillingcouldresult inashortcircuit.Useinsulationprotectionglovesandrstmovecablesinsidea chassisawaywhendrillingisnecessaryonachassis.
àProtecteyesduringdrillingasdustoryingdebrismaydamageeyes.
àCleananydebrisintimeafterdrilling.
lLightning
Danger!
Donotperformhigh-voltage,AC,irontowerormastoperationsinathunderstorm.
Thunderstormswouldgiverisetoastrongelectromagneticeldintheatmosphere. Therefore,theequipmentmustbegroundedandprotectedintimeagainstlightning strikes.
1-4
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 13
Chapter1SafetyDescription
AntistaticSafetyInstructions
Caution!
Staticelectricityproducedbyhumanbodycandamagestatic-sensitivecomponentson circuitboard,suchaslarge-scaleintegratedcircuits.
lFrictioncausedbyhumanbodyactivitiesistherootcauseofelectrostaticcharge
accumulation.Staticvoltagecarriedbyahumanbodyinadryenvironmentcanbe upto30kV,andcanremainthereforalongtime.Anoperatorwithstaticelectricity maydischargeelectricitythroughacomponentwhenhe/shetouchestheconductor andcausingdamage.
lWearanantistaticwriststrap(theotherendofwriststrapmustbewellgrounded)
beforetouchingtheequipmentorholdingaplug-inboard,circuitboard,Integrated Circuit(IC)chiporotherdevices,topreventhumanstaticelectricityfromdamaging sensitivecomponents.
lTheantistaticwriststrapusedmustbesubjecttoregularcheck.Donotreplacethe
cableofanantistaticwriststrapwithanyothercables.
lDonotcontactstatic-sensitivemoduleswithanyobjectthateasilygeneratesstatic
electricity.Forexample,frictionofpackagebag,transferboxandtransferbeltmade frominsulationplasticmaycausestaticelectricityoncomponents.Dischargeofstatic electricitymaydamagecomponentswhentheycontactahumanbodyortheground.
lModulesshouldonlycontactmaterialssuchasanantistaticbag.Keepmodulesin
antistaticbagsduringstorageandtransportation.
lDischargestaticelectricityofthetestdevicebeforeuse,thatis,groundthetestdevice
rst.
lDonotplacethemodulenearastrongDCmagneticeld,suchasthecathode-ray
tubeofamonitor.Keepthemoduleatleast10cmaway.
HoistingHeavyObjects
Warning!
Whenhoistingheavyobjects,ensurethatnobodyisstandingorwalkingunderthehoisted object.
lEnsurethehoistercanmeethoistingrequirementswhendisassemblingheavy
equipment,ormovingandreplacingequipment.
lTheinstallationpersonnelmustbedulytrainedandqualiedforhoistingoperations. lHoistingtoolsmustbeinspectedandcompletebeforeservice.
1-5
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 14
ZXSDRRSU82CUserManual
lMakesurethathoistingtoolsarexedrmlyonasufcientlysecuredobjectorwall
lGivebrieforalinstructionsduringhoistingoperationstopreventanymishap.
Unplugging/PluggingaModule
lNeverplugamodulewithexcessiveforce,toensurethatthepinsonthebackplane
lPlugthemodulerightintotheslotandmakesuremodulecircuitfacesdonotcontact
lKeephandsoffthemodulecircuit,components,connectorsandcabletroughwhen
RackMountSafetyInstructions
RackMountInstructions-Thefollowingorsimilarrack-mountinstructionsareincluded withtheinstallationinstructions:
lElevatedOperatingAmbient-Ifinstalledinaclosedormulti-unitrackassembly,the
lReducedAirFlow-Installationoftheequipmentinarackshouldbesuchthatthe
lMechanicalLoading-Mountingoftheequipmentintherackshouldbesuchthata
lCircuitOverloading-Considerationshouldbegiventotheconnectionofthe
lReliableEarthing-Reliableearthingofrack-mountedequipmentshouldbe
beforethehoistingoperation.
donotgetdeformed.
eachotherlestanyshortcircuitmayoccur.
holdingamodule.
operatingambienttemperatureoftherackenvironmentmaybegreaterthanroom ambient.Therefore,considerationshouldbegiventoinstallingtheequipmentinan environmentcompatiblewiththemaximumambienttemperature(Tma)speciedby themanufacturer.
amountofairowrequiredforsafeoperationoftheequipmentisnotcompromised.
hazardousconditionisnotachievedduetounevenmechanicalloading.
equipmenttothesupplycircuitandtheeffectthatoverloadingofthecircuitsmight haveonovercurrentprotectionandsupplywiring.Appropriateconsiderationof equipmentnameplateratingsshouldbeusedwhenaddressingthisconcern.
maintained.Particularattentionshouldbegiventosupplyconnectionsotherthan directconnectionstothebranchcircuit(e.g.useofpowerstrips).
OtherSafetyInstructions
Note:
Donotperformmaintenanceordebuggingindependently,unlessaqualiedpersonis present.
lPerformanairtighttestbeforeRRUdelivery,andprohibitdisassemblingtheRRUon
site.
1-6
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 15
Chapter1SafetyDescription
lReplacinganypartsormakinganychangestotheequipmentmightresultinan
unexpecteddanger.Therefore,besurenottoreplaceanypartsorperformany changestotheequipmentunlessauthorizedotherwise.
lDuetothatRRUisinhightemperatureduringrunning,theRRUshouldbeinstalled
insomeregionsoutofoperators'reachorstrictlyrestricted.
lContactZTEofceifyouhaveanyquestion,toensureyoursafety.
1-7
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 16
ZXSDRRSU82CUserManual
Thispageintentionallyleftblank.
1-8
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 17
Chapter2
ProductDescripition
TableofContents
Overview....................................................................................................................2-1
PositioninaNetwork..................................................................................................2-1
OuterView.................................................................................................................2-2
ProductionFunctions..................................................................................................
ProductionFeatures...................................................................................................2-4

2.1Overview

ZTESoftwareDenedRadio(SDR)usesanarchitectureofseparatingthebaseband partfromtheRadioFrequency(RF)part.Thisarchitecturefeatureshighintegration, lowconsumption,exiblecongurationandconvenientinstallation&maintenance.The newgenerationZTECDMABaseStation(BS)productsbasedontheSDRistherst SDR-basedCDMABSintheindustry.Itisabletohelptheoperatorshavequalitative leap.TheformofthisproductcanbedistributedBBU+RRUorBBU+RSU.Theproduct formofZTESDRcanbedistributedBBU+RRUorBBU+RSU,macroBSormicroBS.
2-3
ZXSDRRSU82CistheRSUpartofZTECDMA2000distributedSDRCommonBTS PlatformSolution.ItprovidesfunctionsincludingRFmodulation/demodulation,forward poweramplication,reverselownoiseamplication,RFperformancemeasurementand carrierpowercontroletc.
Withasmallersizeandlighterweight,theZXSDRRSU82Chassignicantadvantagesfor savingspace,relocations,installationexibility ,andpowersavings.Itdesignedforboth indoorandoutdoorapplications.

2.2PositioninaNetwork

InCDMAmobilecommunicationnetwork,therelationshipbetweenZXSDRRSU82Cand othernetworkentitiesisshowninFigure2-1.
2-1
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 18
ZXSDRRSU82CUserManual
Figure2-1ZXSDRRSU82CPositioninaNetwork
TheZXSDRRSU82CisanindependentRFsubsystem.T ogetherwithBBU,itforms thecompleteBTS.TheBTSimplementsradiotransmissionwiththeMSthroughthe CDMA2000airinterface.Inaddition,theBTSimplementscontrolofradiochannelsand communicationwiththeBSC

2.3OuterView

Figure2-2showstheouterviewofZXSDRRSU82C.
2-2
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 19
Figure2-2OuterViewofZXSDRRSU82C
Chapter2ProductDescripition

2.4ProductionFunctions

ZXSDRRSU82CprovidesprimaryfunctionsisshownasT able2-1.
Table2-1ThePrimaryFunctionsofZXSDRRSU82C
FunctionDescription
Band:800MHz/1.9GHz/2.1GHz
RFmodulation/demodulation
RF
Interface
RFtransceiverduplexer
LownoiseamplicationforreceivedRFsignal
AmplicationfortransmittedRFsignal
RFtransceiver
Baseband-RFinterface:compliantwithCommonPublicRadioInterface
(CPRI)protocol
Airinterface:compliantwithIS-2000ReleaseAandIS-856-A
2-3
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 20
ZXSDRRSU82CUserManual
FunctionDescription
Electroniclabel
RemoteupgradeofsoftwareversionforFPGA/BOOT/DSP/CPU
Remoteresetofserviceboards
Equipment
maintenanceandtest
ReliabilityReversevoltageprotection
ScenarioIndoorandoutdoorapplications
RSSIquery
Automaticcalibration
Reversespectrumquery:queryingthereversereceivedsignalspectrumof
eachcarrier
Poweramplicationcontrolandprotection:over-power,over-temperature,
andstandingwavealarm

2.5ProductionFeatures

HerearetheproductfeaturesofZXSDRRSU82C
lItadoptsmultiplenewtechnologiesinheatdissipationandconnectionmode;hence
itfeatureshighintegrationandcompactstructure.
lItadoptsthesingle-sideddesigninwhichdualduplexerscarrythetransceiver,power
module,andpoweramplicationmodule.
lItistherstRSUthatsupportsthe2T4Rapplicationintheindustry. lEasytransportationandinstallationwillsavelaborandbuildingcosts lSuitableforcomplicatedbasestationenvironments
SupportsstarandchainnetworksbetweenbasebandandRFtoprovidemore convenientsolutionsforcomplicatedbasestationenvironments.
2-4
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 21
Chapter3
TechnicalDescripition
TableofContents
SystemArchitecture...................................................................................................3-1
SignalProcessingFlow..............................................................................................3-2
TechnicalSpecications.............................................................................................3-2

3.1SystemArchitecture

TheZXSDRRSU82Ccomprisestransceiverunit(TR),poweramplierunit(PA),duplexer unit(FL),andpowerunit(PB).Figure3-1illustratestheZXSDRRSU82C’ssystem architecture.
Figure3-1FrameStructureofZXSDRRSU82C
ThefunctionsofZXSDRRSU82C’ssubsystemisshownasTable3-1.
Table3-1Thefunctionsofsubsystem
PartDescription
TR,theunitthatintegratestheprocessor ,clock,CPRIinterface,DPD
digitalpredistortion,RFtransmittingandreceivingfunctions,isthecore
TR
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
unitoftheZXSDRRSU82C.
3-1
Page 22
ZXSDRRSU82CUserManual
PartDescription
PA
FL
PB
lAmpliesdownlinkRFsignalinputviatheTRandthensendsthe
signaltotheFL
lProvidesdigitalpre-distortionfeedbacksignalsfortheTR
lProvidesaP Aoutputenable/disableinterface
lPerformslteringandlownoiseamplicationofthereverseCDMA
signalfromtheantenna
lFilterstheforwardRFsignaltobesent
lReportsLNAalarmstotheTR
lInthecaseofmain/diversitycombinedcabinets,themainreceive
LNAoutputendoftheFLhasthepowersplitterfunctionandreserves
anexternalport(Rxout)
Converts-48VDCinputpowersupplytoDCpowersupplyrequiredby
thePA,TR,orFL

3.2SignalProcessingFlow

TheinternalsignalprocessingowofZXSDRRSU82Cisasbelow:
lForwardlinkprocessing
ThebusinessdatafromBBUenterstheTR,andthenforintermediatefrequency processing.Afterthepoweramplicationsenttotheantennafortransmission.
lReverselinkprocessing
ThereverseCDMAsignalsfromtheantennaareconvertedtobasebanddigitalsignal byTR,thensendtoBBU.

3.3TechnicalSpecifications

3.3.1PhysicalIndices

3.3.1.1Dimension
ThedimensionsofZXSDRRSU82Cinmmare:482.6(H)×88(W)×360.0(D).
3.3.1.2Weight
WeightofaZXSDRRSU82C:<15kg(33.1pounds).

3.3.2PowerIndices

lPowerSupply
3-2
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 23
-48VDCVoltagerange:-40V~-57V .
lPowerConsumption
Inthecaseof2S-2T ,4C/S,15W/C,thetotalpowerconsumptionoftheequipmentis 600W.

3.3.3CapacityIndices

ZXSDRRSU82CCapacityIndicesisshownasT able3-2
Table3-2ZXSDRRSU82CCapacityIndices
ItemCarrierssupported
14C1X+4C1X
24C1X+4CDO
34CDO+4CDO
4theMAX8C/2S-2T
Chapter3T echnicalDescripition

3.3.4TemperatureandHumidity

Temperature:-40℃~+55℃.Thechangefrequencymustbelessthan0.5℃/min.
Relativehumidity:5%~95%

3.3.5EnvironmentalClasses

lGradeOfProtection:IP55 lGroundingRequirements:Jointgroundingresistanceless1W;BTSgrounding
resistanceless5W.
lNoise:Noiseofworkingenvironment:less65dBA

3.3.6ReliabilityIndices

lMeanTimeBetweenFailures(MTBF):>100,000hours lMTTR(MeanTimeToRepair):<0.5hour lAvailability:>99.999%

3.3.7RFIndices

RFindicesoftheZXSDRRSU82Ccomplywith3GPP2C.S0010-C,Recommended MinimumPerformanceStandardsforcdma2000SpreadSpectrumBaseStationand 3GPP2C.S0032-A,RecommendedMinimumPerformanceStandardsforCDMA2000 HighRatePacketDataAccessNetwork.
Table3-3illustratesthe1.9GHztransmitterindices.
3-3
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 24
ZXSDRRSU82CUserManual
Table3-31.9GHzTransmitterIndices
NameIndex
Operatingband1.9GHz(1930MHz~1950MHz)
Transmitteroutputfrequency
tolerance
Occupiedchannelbandwidth1.25MHz
OutputpowerattheTopof
Cabinet(TOC)
Totaltransmitpower
ModulationmodeQuadratureamplitudemodulation
Conductedspuriousemission
andradiatedspurious
emissionsuppression
±0.01ppm
60W
Thetotaltransmitpoweriswithin+2dBand-2dBofthe
manufacturer’sratedpower.
<-45dBc@±885kHzoffsetCenterFreq(RBW30kHz)
<-55dBc@±1.98MHzoffsetCenterFreq(RBW30kHz)
>4MHzOFFSET :
<-36dBm(RBW1kHz)@9KHz<f<150kHz
<-36dBm(RBW10kHz)@150kHz<f<30MHz
<-36dBm(RBW100kHz)@30MHz<f<1GHz
4-16MHzOFFSET:
<-30dBm(RBW30kHz)@1GHz<f<12.5GHz
16M-19.2MOFFSET :
<-30dBm(RBW300kHz)@1GHz<f<12.5GHz
>19.2MHzOFFSET :
<-30dBm(RBW1MHz)@1GHz<f<12.5GHz
Transmitterintermodulation
performance
Pilottimetolerance
toleranceofpilotchannelto
otherchannels
Waveformquality
Pilotcodedomainpower
IfoneBTStransmitsattheratedpowerbutanotherBTS’output
poweris30dBlessthantheformer’sratedpower.Whenthepowers
oftwoBTSsarecombinedontheantennaport,thegenerated
intermodulationspuriousemissionmeetstheconductedspurious
emissionrequirement.TheIFdifferenceofthetransmitsignalsof
twoBTSsis1.25M.
ThePNtimetolerancefallswithin3usandtheinter-carriertolerance
fallswithin1us.
Timedifference:<±50ns TimeT olerance/phase
Phasedifference:<0.05rad
Rhoisgreaterthan0.990dBmunderthecongurationofasingle
pilot.
Withthestandard9CHconguration,thepilotcodedomainpoweris
intherangeof-7.0±0.5dB.
3-4
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 25
NameIndex
Chapter3T echnicalDescripition
Inactivechannelcodedomain
power
DOMACinactivechannel
codedomainpower
DODA TAchannelcode
domainpower
RadiofrequencyFrontEnd
SWR
Withthestandard9CHconguration,theinactivechannelcode
domainpowerislessthan-27dB.
Withcongurationof13FLUSs,theMACinactivechannelcode
domainpowerislessthan-29.5dB(type2).
Withcongurationof13FLUSsattherateof614.44kbs(test1),
theDATAchannelcodedomainpowerisintherangeof-15.5dB
to-14.5dB.
Pilotchannel:Rho>0.97
MACchannel:Rho>0.912 WavequalityofDOchannels
DAT Achannel:Rho>0.97
<2.0
Table3-4illustratesthe1.9GHzreceiverindices.
Table3-41.9GHzReceiverIndices
NameIndex
Operatingband1.9GHz(1850MHz~1870MHz)
Receiversensitivity<-115dBm
Whenthelowerlimitisthereceiversensitivityandtheupperlimit
Receiverdynamicrange
Noisegure<3
Adjacentchannelselection
(ACS)
Singletonedesensitization
Intermodulationspurious
responseattenuation
(noiselevel)equals-55dBm/1.23MHz(Eb/N0=10dB±1dB),the
FrameErrorRate(FER)islowerthan1%.
BandClass6:>-53dBm(±2.5M)
Inthepresenceofasingletonethatis50dBabovetheCDMAsignal
level,andisatoffsetof±750kHzfromthecenterfrequency,the
outputpoweroftheMSincreasesbynomorethan3dB,andthe
FERislessthan1.5%.
Inthepresenceofasingletonethatis75dBabovetheCDMAsignal
level,andisatoffsetof±900kHzfromthecenterfrequency,the
outputpoweroftheMSincreasesbynomorethan3dB,andthe
FERislessthan1.5%.
Inthepresenceoftwointerferingtonesthatare60dBabovethe
CDMAsignallevel,andareatoffsetsof1.25MHzand2.05MHz,
and-1.25MHzand-2.05MHzfromthecenterfrequency ,theoutput
poweroftheMSincreasesbynomorethan3dB,andtheFER
islessthan1.5%.
3-5
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 26
ZXSDRRSU82CUserManual
NameIndex
Conductedspurious
emissionsandradiated
spuriousemissions
RadiofrequencyFrontEnd
SWR

3.3.8InterfaceIndices

TheinterfaceindicesofZXSDRRSU82CisshownasT able3-5.
Table3-5DescriptionofZXSDRRSU82C’sinterfaces
TypeDescriptionIndex
CPRIFiber/Cable2CPRIinterfaces:1CPRIforBBUor
UEUminterface2Tx/Rx2diversityreceivers
<-80dBm,measuredwithintheBTSreceiveband
<-60dBm,measuredwithintheBTStransmitband
<2.0
upper-levelRSU1CPRIforlower-levelRSU
3-6
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 27
Chapter4
HardwareDecsripition
TableofContents
Function.....................................................................................................................4-1
Panel..........................................................................................................................
Button........................................................................................................................4-2
Indicators...................................................................................................................4-3
PanelInterfaces.........................................................................................................

4.1Function

RSUprovidesthefollowingfunctions:
lCommunicationwiththebasebandsubrack lConversionbetweenairinterfaceRFsignalsanddigitalsignals lRFsignalamplication,transmission,andreception lClocksynchronization.
4-1
4-4

4.2Panel

Figure4-1illustratestheZXSDRRSU82Cpanel.
4-1
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 28
ZXSDRRSU82CUserManual
Figure4-1ZXSDRRSU82CPanel

4.3Button

Thereisonlyonebutton(RST)ontheZXSDRRSU82Cpanel.Table4-1describesthe button.
Table4-1ZXSDRRSU82CPanelButtonDescription
ButtonDescription
RSTResetbutton
4-2
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 29

4.4Indicators

Table4-2describesZXSDRRSU82Cpanelindicators.
Table4-2ZXSDRRSU82CPanelIndicatorDescription
IndicatorColorMeaningDescription
Chapter4HardwareDecsripition
RUNGreenRSUrunning
indicator
ALMRedRSUalarmindicatorOffwhenRSUrunsnormallyorisbeing
LNK1GreenIndicatoroftherst
opticalport/electrical
portconnection
OnwhenRSUisbeingresetorstarted.
Blinksin1HzwhenRSUrunsnormally.
Blinksin5Hzwhentheversionisbeing
downloaded.
OffwhenSelftestfails.
resetorstarted,orRSUversionisbeing
downloaded.
Blinksin5Hzwhenacriticalalarmis
generated.
Blinksin1Hzwhenaminoralarmis
generated.
A:Constantlyon.Theopticalberconnection
isnormal.
B:Flashesquickly(1Hz).Itindicatesthatthe
opticalportcommunicationisabnormal.
C:Off.Itindicatesthatthereisnooptical
moduleorthereisnoopticalsignal.(During
thepower-onprocess,theindicatorisinthis
statebydefault.)
Thisindicatorisusedmainlytocheckwhether
theopticalberlinkisconnectedontheeld.
Iftheindicatorashesortheindicatorison,it
indicatesthatthephysicalconnectionofthe
opticalberisnormal.
LNK2GreenIndicatorofthe
secondoptical
port/electricalport
connection
4-3
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
A:Constantlyon.Theopticalberconnection
isnormal.
B:Flashesquickly(1Hz).Itindicatesthatthe
opticalportcommunicationisabnormal.
C:Off.Itindicatesthatthereisnooptical
moduleorthereisnoopticalsignal.(During
thepower-onprocess,theindicatorisinthis
statebydefault.)
Thisindicatorisusedmainlytocheckwhether
theopticalberlinkisconnectedontheeld.
Iftheindicatorashesortheindicatorison,it
indicatesthatthephysicalconnectionofthe
opticalberisnormal.
Page 30
ZXSDRRSU82CUserManual
IndicatorColorMeaningDescription
RF1Red/GreenRFsignalabnormal
RF2Red/GreenRFsignalabnormal

4.5PanelInterfaces

indicatoroftherst
antennaport
indicatorofthe
secondantennaport
A:Thegreenindicatorisconstantlyon.It
indicatesthattheRFoutputisnormal.
B:Theredindicatorisconstantlyon.It
indicatestheantennastandingwavealarm.
C:Thegreenindicatorisoff.Itindicatesthat
thereisnoRFoutput(orthepoweramplier
isshutoff.)(Duringthepower-onprocess,the
twoindicatorsareoffbydefault.)
A:Thegreenindicatorisconstantlyon.It
indicatesthattheRFoutputisnormal.
B:Theredindicatorisconstantlyon.It
indicatestheantennastandingwavealarm.
C:Thegreenindicatorisoff.Itindicatesthat
thereisnoRFoutput(orthepoweramplier
isshutoff.)(Duringthepower-onprocess,the
twoindicatorsareoffbydefault.)
Table4-3describesZXSDRRSU82Cpanelinterfaces.
Table4-3ZXSDRRSU82CPanelInterfaceDescription
InterfaceEntityatendAEntityatendBDescription
ANT1
(TX1/RX1A)
ANT2(RX1B)RSUTherstRxantennaTherstreceivediversityantennafeeder
ANT3(TX2/
RX2A)
ANT4(RX2B)RSUThesecondRx
TX1RX1RSUBBUortheupperlevel
TX2RX2RSULowerlevelcascaded
DBGRSUPCandtestdevice
RSUTherstTxantennaTherstTx/Rxantennafeederinterface
interface
RSUThesecondTx
antenna
antenna
cascadedRSU
RSU
(testboard)
ThesecondTx/Rxantennafeeder
interface
Thesecondreceivediversityantenna
feederinterface
ConnectedtotheCPRIinterfaceofBBU
orupperlevelcascadedRSU
ConnectedtotheCPRIinterfaceofthe
lowerlevelcascadedRSU
Debuginterfaceandtestinterface
4-4
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 31
Chapter4HardwareDecsripition
InterfaceEntityatendAEntityatendBDescription
MONRSUPeripheralProvidesinputinterfaceforfourchannels
ofdrycontactsignalsandRS485
environmentmonitoringinterface
AISGRSUAntennafeederConnectedtoantennafeederAISG
interface
POWERRSUfrontpanelRFpowersupplyin
thepowerdistribution
subrack
-48VDCpowerinputinterface
4-5
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 32
ZXSDRRSU82CUserManual
Thispageintentionallyleftblank.
4-6
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 33
Chapter5
HardwareInstallation
TableofContents
InstallingtheRSUModule..........................................................................................5-1
ConnectingRSUMonitoringCable.............................................................................5-9
InstallingOpticalFibersBetweenBBUandRSU......................................................5-10
InstallingtheInterconnectedCableBetweenBBUandRSU.....................................
InstallingtheRFJumper...........................................................................................5-15

5.1InstallingtheRSUModule

Prerequisites
lBeforeinstallingtheRFmodule,weartheESDwriststraptoavoiddamagingtheRF
module.
lTheRFcabinethasalreadybeeninstalled.
5-12
Context
Figure5-1showsthefrontpanelofaZXSDRRSU82C.
5-1
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 34
ZXSDRRSU82CUserManual
Figure5-1ZXSDRRSU82CPanel
Note:
WhenaZXSDRRSU82Cisusedinasingle-sectorandhigh-carrierscenario,theRF jumperconnectsonlytotheANT1andANT3interfaces.
Steps
1.Determinethetargetslot,holdthehandleofthemodulewithonehand,supportthe lowerbackofthemodulewiththeotherhand,andtrytomakeparallelthemoduleand theguidingplane,asshowninFigure5-2.
5-2
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 35
Figure5-2Step1
Chapter5HardwareInstallation
2.Pushthemoduleslightlyintotheslottomorethanhalfthedepthoftheslot,asshown inFigure5-3.
5-3
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 36
ZXSDRRSU82CUserManual
Figure5-3Step2
3.Changetheplacewhereexerciseforceandthenpushfurtherthemodulewitheven force,asshowninFigure5-4.
5-4
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 37
Figure5-4Step3
Chapter5HardwareInstallation
4.Pushthemoduleuntiltheinnersideofthefrontpanelcloselytouchtheverticalshaft, asshowninFigure5-5.
5-5
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 38
ZXSDRRSU82CUserManual
Figure5-5Step4
5.SecurethemoduleusingveM5x20screws,asshowninFigure5-6.
5-6
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 39
Figure5-6Step5
Chapter5HardwareInstallation
1.Fixingthecabinetwith
5M5x20screws
2.Fixingthegrounding lug
6.Securethegroundlug.
AsshowninFigure5-6,theM5x20screwssecuresthegroundlugoftheRSUmodule tothegroundpoints.
–EndofSteps–
Result
Figure5-7showsthecompletionofinstallingtheRFmodule.
5-7
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 40
ZXSDRRSU82CUserManual
Figure5-7RSUModuleInstalledCompletely
Follow-UpAction
AfterinstallingRSUmodules,connecttheRSUpowercablestotheRSUpower interfaces.RSUpowercableshavebeenroutedtoproperslots,asshowninFigure5-8.
Figure5-8PowerCableConnectingtheRSU
5-8
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 41

5.2ConnectingRSUMonitoringCable

Prerequisites
lZXSDRRSU82CRFcabinethasalreadybeeninstalled. lTheRSUmodulehasalreadybeeninstalled.
Context
TheRSUmonitoringcableoftheRFcabinetisroutedtotherightsideoftheRFcabinet indelivery,asshowninFigure5-9.AftertheRSUmoduleisinstalled,inserttheterminal oftheRSUmonitoringcabletotheMON(monitoring)interfaceoftheRSUmodule.
Figure5-9RSUMonitoringCable
Chapter5HardwareInstallation
Note:
IfmultipleRSUmodulesneedtobemonitored,onlyoneRSUmoduleneedstobe connectedtotheRSUmonitoringcable.
Steps
1.ConnectoneendoftheRSUmonitoringcabletotheMON(monitoring)interfaceof theRSUmoduleandfastenthescrew.
2.BundletheRSUmonitoringcable.
Figure5-10showstheconnectedRSUmonitoringcable.
5-9
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 42
ZXSDRRSU82CUserManual
Figure5-10InstallingtheRSUMonitoringCable
–EndofSteps–

5.3InstallingOpticalFibersBetweenBBUandRSU

Prerequisites
lTheESDwriststrapmustbeworn. lThebasebandpowercabinetandtheRFcabinethavebeenindependentlyinstalled.
Context
WhenthebasebandpowercabinetandtheRFcabinetareinstalledsidebysideorthey arefarawayfromeachother,youneedtoconnectBBUandRSUusingopticalbers.
Payattentiontothefollowingpointswheninstallingopticalbers:
lDonotdamagetheopticalbercladdingduringoperations. lProtectopticalberconnectorsandavoidcontaminatingthem. lDonotforciblybundleopticalbers. lCurveopticalbersattheturning.
Steps
1.Afxatemporarylabel.
5-10
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 43
Chapter5HardwareInstallation
Afxtemporarylabelstobothendsofthenewopticalbertosetupamapping.If morethanoneopticalberneedstobeinstalled,usedifferentlabelstodifferentiate opticalbers.
2.Routeopticalbers.
a.Opticalbersgooutfromthesidewaterproofmoduleofthebasebandmoduleand
gothroughtheroutingaperturesonthebase.
b.Then,opticalbersgothroughtheroutingaperturesonthebaseoftheRFcabinet,
traversethewaterproofmodules,andconnecttothesixopticalinterfacesforRF modules.
Figure5-11showshowopticalberstraversethewaterproofmodules.
Figure5-11WaterproofModulethroughWhichOpticalFibersPass
3.Insertopticalberconnectors.
Insertopticalberconnectorsaccordingtothemappingontemporarylabels.
Caution!
Insertopticalberconnectorstightly.
4.Bundleopticalbers.
Bundleandsecureopticalbersalongtheroutingtroughs,whichcomplieswith relevantregulations.
5.Afxanengineeringlabeltoanopticalber. Removethetemporarylabelfortheopticalberandafxanengineeringlabel.
5-11
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 44
ZXSDRRSU82CUserManual
Caution!
Protectanopticalberwiththewindingtubewhenroutingtheopticalberinsidethe cabinet.Protectanopticalberwiththecorrugatedpipewhenroutingtheopticalber outsidethecabinet.
–EndofSteps–

5.4InstallingtheInterconnectedCableBetweenBBU andRSU

Prerequisites
lTheZXSDRRSU82Ccabinethasalreadybeeninstalled. lTheBBUmoduleandRSUmodulehavealreadybeeninstalled.
Context
ZXSDRRSU82CInthesystem,opticalbersorSFPcablescanbeusedtoconnectBBU andRSU.DuringthestackedinstallationoftheZXSDRRSU82C,a2mSFPhigh-speed cableisrecommendedforinterconnectingBBUandRSU.Figure5-12showsanSFP cable.
Figure5-12High-SpeedCable
5-12
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 45
Chapter5HardwareInstallation
Steps
1.AfxtemporarylabelstobothendsoftheSFRcable,withmarkings0-5tosetup one-to-onemappingwithinterfacesTX0RX0toTX5RX5ofBBUandsixTX/RX interfacesofRSU.
2.InsertoneendoftheSFPcabletoaTX/RXinterfaceofRSU.
3.RoutetheSFPcablealongtheroutingtroughandcabinetsidestotheFSmoduleof BBU.TheSFPcablesconnectingtotheRSUsinslots1to3ontheRFcabinetgo throughtheleftroutingaperturesandthoseSFPcablesgothroughtherightapertures ifconnectingtoslots4to6ontheRFcabinet,asshowninFigure5-13andFigure
5-14.
Figure5-13LayoutoftheSFPCablesintheRFCabinet
5-13
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 46
ZXSDRRSU82CUserManual
Figure5-14SFPCableLayout
4.InsertSFPcablesintotheinterfacesTX0RX0toTX5RX5oftheBBUFSboard accordingtothemarkings0-5,asshowninFigure5-15.
Figure5-15FSBoardConnectingtotheBBU
5.BundleSFPcables.
6.Removetemporarylabelsandafxengineeringlabels.
–EndofSteps–
5-14
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 47

5.5InstallingtheRFJumper

Prerequisites
TheZXSDRRSU82CRFcabinetandothermoduleshavealreadybeeninstalled.
Context
TheRFjumpersforthethreeZXSDRRSU82Cgothroughthewaterproofmoduleonthe right.
RemovethefrontbafeofthebasebeforeinstallingtheRFjumpersandreseatthefront bafeafteralljumpersarecompletelyinstalled.
ThetypicallossoftheRFcable(withthefrequency1.9GHzandcablelength30m)is3.4 dB.
Steps
1.ConnecttheRFjumperstoANT1toANT4interfacesofRSUfromlefttoright.
Chapter5HardwareInstallation
2.WearthewaterproofrubberplugaftereverytwoRFjumpersareinstalled.
3.Insertthehorizontalandlongitudinalslideblocksandusethehexagonringwrenchto fastenthem.
Caution!
Clampthewaterproofrubberplugtightlyandmakesurethattheunusedcabling aperturewearstheplug.
4.RepeattheprecedingstepstoinstallotherRSU-relatedjumpers.
–EndofSteps–
Result
Figure5-16showsthecompletionofinstallingtheRFjumpers.
5-15
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 48
ZXSDRRSU82CUserManual
Figure5-16AntennaFeederJumperInstalledCompletely
TheRFjumpersgooutfromthebase,asshowninFigure5-17.Thecablesbetween cabinetsmustbeprotectedwithprotectivetubes,withoutanyexposedpartofthecables andtheopeningsattwoendsofthesecablesmustbesealed,asshowninFigure5-18.
Figure5-17Lead-OutoftheAntennaFeederJumper
5-16
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 49
Figure5-18CablesinTubes
Chapter5HardwareInstallation
5-17
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 50
ZXSDRRSU82CUserManual
Thispageintentionallyleftblank.
5-18
SJ-20101019140047-001(R1.2)|08/08/2011ZTEProprietaryandCondential
Page 51

Figures

Figure2-1ZXSDRRSU82CPositioninaNetwork....................................................2-2
Figure2-2OuterViewofZXSDRRSU82C...............................................................
Figure3-1FrameStructureofZXSDRRSU82C.......................................................3-1
Figure4-1ZXSDRRSU82CPanel...........................................................................4-2
Figure5-1ZXSDRRSU82CPanel...........................................................................5-2
Figure5-2Step1......................................................................................................5-3
Figure5-3Step2......................................................................................................5-4
Figure5-4Step3......................................................................................................5-5
Figure5-5Step4......................................................................................................
Figure5-6Step5......................................................................................................5-7
Figure5-7RSUModuleInstalledCompletely............................................................5-8
Figure5-8PowerCableConnectingtheRSU...........................................................5-8
Figure5-9RSUMonitoringCable.............................................................................5-9
Figure5-10InstallingtheRSUMonitoringCable.....................................................5-10
Figure5-11WaterproofModulethroughWhichOpticalFibersPass........................
Figure5-12High-SpeedCable................................................................................5-12
Figure5-13LayoutoftheSFPCablesintheRFCabinet........................................5-13
2-3
5-6
5-11
Figure5-14SFPCableLayout................................................................................5-14
Figure5-15FSBoardConnectingtotheBBU.........................................................5-14
Figure5-16AntennaFeederJumperInstalledCompletely......................................5-16
Figure5-17Lead-OutoftheAntennaFeederJumper.............................................
Figure5-18CablesinTubes...................................................................................5-17
5-16
I
Page 52
Thispageintentionallyleftblank.
Figures
Page 53

Tables

Table1-1SafetySymbolsDescription.......................................................................1-2
Table2-1ThePrimaryFunctionsofZXSDRRSU82C...............................................
Table3-1Thefunctionsofsubsystem.......................................................................3-1
Table3-2ZXSDRRSU82CCapacityIndices............................................................3-3
Table3-31.9GHzTransmitterIndices......................................................................3-4
Table3-41.9GHzReceiverIndices..........................................................................3-5
Table3-5DescriptionofZXSDRRSU82C’sinterfaces..............................................3-6
Table4-1ZXSDRRSU82CPanelButtonDescription...............................................4-2
Table4-2ZXSDRRSU82CPanelIndicatorDescription............................................
Table4-3ZXSDRRSU82CPanelInterfaceDescription............................................4-4
2-3
4-3
III
Page 54
Thispageintentionallyleftblank.
Tables
Page 55

Glossary

AISG
-AntennaInterfaceStandardsGroup
BBU
-BaseBandUnit
BSC
-BaseStationController
BTS
-BaseTransceiverStation
CPRI
-CommonPublicRadioInterface
MS
-MobileStation
RF
-RadioFrequency
RSSI
-ReceivedSignalStrengthIndicator
RSU
-RFSystemUnit
SDR
-SoftwareDenedRadio
V