ZTE R8882L268 User Manual

Page 1
ZXSDRR8882L268
LTERemoteRadioFrequencyUnit
UserManual
Version:V2.00
ZTECORPORATION No.55,Hi-techRoadSouth,ShenZhen,P .R.China Postcode:518057 Tel:+86-755-26771900 Fax:+86-755-26770801 URL:http://ensupport.zte.com.cn E-mail:support@zte.com.cn
Page 2
LEGALINFORMATION
Copyright©2013ZTECORPORATION.
Thecontentsofthisdocumentareprotectedbycopyrightlawsandinternationaltreaties.Anyreproductionor
distributionofthisdocumentoranyportionofthisdocument,inanyformbyanymeans,withoutthepriorwritten
consentofZTECORPORATIONisprohibited.Additionally,thecontentsofthisdocumentareprotectedby
contractualcondentialityobligations.
Allcompany,brandandproductnamesaretradeorservicemarks,orregisteredtradeorservicemarks,ofZTE
CORPORATIONoroftheirrespectiveowners.
Thisdocumentisprovided“asis”,andallexpress,implied,orstatutorywarranties,representationsorconditions
aredisclaimed,includingwithoutlimitationanyimpliedwarrantyofmerchantability,tnessforaparticularpurpose,
titleornon-infringement.ZTECORPORATIONanditslicensorsshallnotbeliablefordamagesresultingfromthe
useoforrelianceontheinformationcontainedherein.
ZTECORPORA TIONoritslicensorsmayhavecurrentorpendingintellectualpropertyrightsorapplications
coveringthesubjectmatterofthisdocument.ExceptasexpresslyprovidedinanywrittenlicensebetweenZTE
CORPORATIONanditslicensee,theuserofthisdocumentshallnotacquireanylicensetothesubjectmatter
herein.
ZTECORPORA TIONreservestherighttoupgradeormaketechnicalchangetothisproductwithoutfurthernotice.
UsersmayvisitZTEtechnicalsupportwebsitehttp://ensupport.zte.com.cntoinquirerelatedinformation.
TheultimaterighttointerpretthisproductresidesinZTECORPORATION.
RevisionHistory
RevisionNo.RevisionDateRevisionReason
R1.02011–01–19FirstEdition
SerialNumber:SJ-20110104194923-001
PublishingDate:2011-01-19(R1.0)
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 3
Contents
AboutThisManual.........................................................................................I
Chapter1FCCStatement..........................................................................1-1
Chapter2ProductOverview.....................................................................
2.1DistributedeNodeBSolution...............................................................................2-1
2.2ProductPositioninNetwork................................................................................
2.3ProductFeatures................................................................................................2-4
2.4ProductFunctions..............................................................................................
2.5ProductAppearance...........................................................................................2-5
2.6InstallationScenario...........................................................................................
2.7ProductNetworking............................................................................................2-5
2.8OperationandMaintenanceIntroduction..............................................................2-6
2.9ProductExternalInterfaces.................................................................................2-7
2.10ProductIndicators............................................................................................2-9
Chapter3ProuductTechnicalIndices.....................................................
3.1PhysicalIndices.................................................................................................3-1
3.2WorkingEnvironment.........................................................................................3-1
3.3Bandwidth..........................................................................................................3-1
3.4PowerRequirements..........................................................................................
2-1
2-3
2-4
2-5
3-1
3-2
3.5PowerConsumption...........................................................................................
3.6TransmissionIndex............................................................................................
3.7PerformanceIndices...........................................................................................
3.8ElectromagneticCompatibility.............................................................................
3.9Reliability...........................................................................................................
Chapter4ProductInstallation..................................................................4-1
4.1SafetyDescription.............................................................................................
4.1.1SafetyGuide............................................................................................4-1
4.1.2SymbolDescription..................................................................................4-1
4.1.3SafetyInstructions....................................................................................4-3
4.1.4HoistingOperationInstructions..................................................................
4.2PreparationBeforeInstallation............................................................................4-6
4.2.1PersonnelPreparation..............................................................................4-6
4.2.2ContainerofZXSDRR8882L268..............................................................
4.2.3UnpackingandCheckingFlow..................................................................4-7
I
3-2
3-2
3-2
3-3
3-6
4-1
4-5
4-6
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 4
4.2.4InstallationAccessories............................................................................4-8
4.2.5InstallationFlow.......................................................................................4-9
4.3MountingOnWall.............................................................................................4-10
4.4MountingOnPole............................................................................................
4.4.1One-T o-OneMounting............................................................................4-14
4.4.2One-T o-TwoMounting............................................................................
4.4.3One-T o-ThreeMounting..........................................................................4-18
4.5MountingOnGantry.........................................................................................
4.6ConnectingCables...........................................................................................
4.6.1ConnectionofExternalCables................................................................
4.6.2ExternalCableInstallationFlow..............................................................4-26
4.6.3InstallingPowerCable............................................................................
4.6.4InstallingGroundingCable......................................................................4-29
4.6.5InstallingFiberBetweeneBBUandeRRU...............................................4-29
4.6.6InstallingFibersBetweeneRRUs............................................................4-31
4.6.7InstallingEnvironmentMonitorCable.......................................................4-32
4.6.8InstallingAISGControlCable..................................................................4-33
4.6.9InstallingAntennaFeederJumper...........................................................4-34
4-14
4-16
4-21
4-25
4-25
4-27
Figures.............................................................................................................I
Tables............................................................................................................III
Glossary.........................................................................................................V
II
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 5

AboutThisManual

Purpose
Thismanualgivesintroductionontheproductdescription,technicalindices,andproduct installation.
IntendedAudience
lHardwareInstallationEngineer lOperationandMaintenanceEngineer
PrerequisiteSkillandKnowledge
Tousethisdocumenteffectively,usersshouldhaveageneralunderstandingofwireless telecommunicationstechnology.FamiliaritywithLTEwirelessnetworkanditsrelated componentsishelpful.
WhatisinThisManual
ChapterSummary
Chapter1,FCCStatementIntroducestheFCCstatementsthatthisdevicecomplies
with
Chapter2,ProductOverviewDescribesproductcharacteristic,interfaces,indicators
Chapter3,ProductT echnicalIndicesDescribesthetechnicalindicesoftheproduct
Chapter4,ProductInstallationDescribesinstallationandcableconnectionofthe
product
I
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 6
II
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 7
Chapter1
FCCStatement
FCC&ICStatement
ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowing twoconditions:
lThisdevicemaynotcauseharmfulinterference. lThisdevicemustacceptanyinterferencereceived,includinginterferencethatmay
causeundesiredoperation.
Note:
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassAdigital device,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovide reasonableprotectionagainstharmfulinterferencewhentheequipmentisoperatedin acommercialenvironment.Thisequipmentgenerates,uses,andcanradiateradio frequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructionmanual, maycauseharmfulinterferencetoradiocommunications.
Operationofthisequipmentinaresidentialareaislikelytocauseharmfulinterferencein whichcasetheuserwillberequiredtocorrecttheinterferenceathisownexpense.
Caution!
Changesormodicationstothisunitnotexpresslyapprovedbythepartyresponsiblefor compliancewillvoidtheuser’sauthoritytooperatetheequipment.Anychangetothe equipmentwillvoidFCCandICgrant.
FCCRadiationExposureStatement
ThisequipmentcomplieswithFCCradiationexposurelimitssetforthforanuncontrolled environment.Thisequipmentshouldbeinstalledandoperatedwithminimumdistance4 mbetweentheradiator&yourbody.
1-1
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 8
ZXSDRR8882L268UserManual
Thispageintentionallyleftblank.
1-2
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 9
Chapter2
ProductOverview
TableofContents
DistributedeNodeBSolution.......................................................................................2-1
ProductPositioninNetwork........................................................................................2-3
ProductFeatures........................................................................................................2-4
ProductFunctions......................................................................................................
ProductAppearance...................................................................................................2-5
InstallationScenario...................................................................................................
ProductNetworking....................................................................................................2-5
OperationandMaintenanceIntroduction....................................................................2-6
ProductExternalInterfaces........................................................................................
ProductIndicators......................................................................................................

2.1DistributedeNodeBSolution

2-4
2-5
2-7 2-9
Tosupplycustomerswithmorecompetitivecommunicationequipmentandsolutioninthe market,ZTEdevelopsandpromotesZTESDReBBU(basebandunit)andeRRU(remote radiounit)distributedeNodeBsolutiontimely,whichjointlyperformLTEeNodeBservice.
ZTEdistributedeNodeBsolutionisshowninFigure2-1.
2-1
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 10
ZXSDRR8882L268UserManual
Figure2-1ZTEDistributedeNodeBSolution
ZTE'sLTEeBBU+eRRUdistributedeNodeBsolutionhasthefollowingpredominance:
1.Savinglaborcostandengineeringcostfornetworking.
eBBU+eRRUdistributedeNodeBequipmentissmallinsize,lightinweight,andeasy fortransportationandengineeringconstruction.
2.Fastnetworking,alsosavingthefeesofrentingequipmentroom.
eBBU+eRRUdistributedeNodeBisapplicabletovarioussites,suchasmountedon steeltower,onbuildingtop,oronwall,etc.It'smoreexibleinselectinginstallation site,andnotrestrictedbythespaceofequipmentroom.Itcanhelpoperatorstodeploy networkrapidly.Itcanalsosavethefeesofrentingequipmentroom,andthenetwork operationcost.
3.Convenientinupgradeandcapacityexpansion;savingtheinitialstagecostofthe network.
eRRUcanbemountedasclosetoantennaaspossible,tosavethecostoffeedcable anddecreasethelossoffeedcable.ItalsocanenhancetheoutputpowerofeRRU andincreasethecoverage.
4.Lowpowerconsumption,power-saving.
2-2
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 11
ComparedwithtraditionaleNodeB,eBBU+eRRUdistributedeNodeBhaslowerpower consumption,whichcangreatlyreducetheinvestmentandcostonelectricpower,and thussavethenetworkoperationcost.
5.Distributednetworking,makinggooduseofoperators'networkresourcessupporting eBBU+eRRUdistributednetworking;supportingstarnetworkingmodebetweeneBBU andeRRU.
6.AdoptingamoreperspectiveandgeneralizedeNodeBplatform.
eBBUadoptstheplatformdesignedforthefutureB3Gand4G.Onehardwareplatform canrealizedifferentstandardmodes,andseveralstandardmodescancoexistinone eNodeB.Inthisway,operators'managementcanbesimplied,andseveraleNodeBs tobeinvestedcanbeintegratedintooneeNodeB(multimodeeNodeB).Theoperators canselecttheevolutiondirectionofthefuturenetworkmoreexibly .

2.2ProductPositioninNetwork

ZXSDRR8882L268isaremoteradiounit(eRRU)ofdistributedeNodeB.Thesignalis transmittedorreceivedthroughZXSDRR8882L268toandfrombasebandprocessing unitforfurtherprocessingthroughCPRIinterface.Byapplyingthedistributedsystem,the feederlosswillbereducedwhentheremoteradiounitispositionedclosetotheantenna. Thecoverageisenlargedwiththissolution.
Chapter2ProductOverview
Figure2-2ProductLocation
Note:
ZXSDRR8882L268coversR8882L188,R8882L708,R8882L808,andR8882L268.
2-3
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 12
ZXSDRR8882L268UserManual

2.3ProductFeatures

Multi-ModeeRRU
ZXSDRR8882L268isfullysoftwaredeneddevice.Itsupportsmulti-modeatthesame frequencybandsimultaneously.Therefore,itfullysatisesoperators’requirementsof hybridnetworkdeploymentandlongtermevolutionwiththelowestcost.
MIMOSupported,BetterPerformance
R8882L268supports2T4R(licenseneeded),R8882L188,R8882L708,andR8882L808 support2T2R,whichcanoptimizespectrumefciencygreatlyandimprovenetworkuplink performance.Asaresult,itbringsbettercustomerexperience.
HigherEfciency,LowerTCO
lZXSDRR8882L268’sPAefciencycanreachupto30%thankstothemostadvanced
DohertyP A,DPDlineartechnology.
lItsupportsdynamicadaptivePApowersupplyduetotheoutputpower,whichreduces
powerconsumption.

2.4ProductFunctions

ZXSDRR8882L268istheremoteradiounitofdistributedbasestation.Thesignalis transmittedorreceivedthroughZXSDRR8882L268to/frombasebandprocessingunit forfurtherprocessingviastandardCPRIinterface.
Theproductbasicfunctionsarelistedbelow:
lSupportsthecongurationof5MHz,10MHz,15MHzand20MHzscalable
bandwidth.
lR8882L188supports1710MHz~1785MHz(uplink)/1805MHz~1880MHz(downlink). lR8882L708supports698MHz~716MHz(uplink)/728MHz~746MHz(downlink). lR8882L808supports832MHz~862MHz(uplink)/791MHz~821MHz(downlink). lR8882L268supports2500MHz~2570MHz(uplink)/2620MHz~2690MHz(downlink). lSupports2x2MIMOondownlink. lSupportsQPSK,16-QAM,64-QAMondownlink,QPSKand16–QAMonuplink. lSupportstransmissionandreceivepowerdetection. lSupportsoverloadpowerprotectionforpoweramplier. lSupportspoweramplierswitchingon/offfunction. lZXSDRR8882L268softwarefailurewillnotaffecttherunningofeBBUandother
ZXSDRR8882L268swhichareconnectedtoit.
lSupportseldstrengthscanning,temperaturequery,VSWRquery,drycontact,
hardware/softwareresetting.
2-4
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 13
Chapter2ProductOverview

2.5ProductAppearance

TheappearanceofZXSDRR8882L268isasshowninFigure2-3.
Figure2-3ProductOverallAppearance

2.6InstallationScenario

2.7ProductNetworking

TheZXSDRR8882L268usuallyinstalledonwalloronpoleorongantry.
ZXSDRR8882L268supportsstarnetworkingmodewitheBBU,asshowninFigure2-4.
2-5
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 14
ZXSDRR8882L268UserManual
Figure2-4StarNetworkingMode

2.8OperationandMaintenanceIntroduction

ZXSDRR8882L268supportssystemoperationandmaintenanceremotelyorlocally .
OperateandMaintainSystemRemotely
RemotelyoperatesandmaintainssystembyusingNetNumenmanagementsystem,as showninFigure2-5.
Figure2-5OperateandMaintainSystemRemotely
2-6
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 15
Chapter2ProductOverview
OperateandMaintainSystemLocally
locallyoperatesandmaintainssystembyusingZTE’sLocalMaintenanceTerminal(LMT) softwarekit,asshowninFigure2-6.
Figure2-6OperateandMaintainSystemLocally

2.9ProductExternalInterfaces

TheZXSDRR8882L268externalinterfacesareshowninFigure2-7andFigure2-8.
Figure2-7ProductExternalInterfacesandGroundingTerminal
2-7
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 16
ZXSDRR8882L268UserManual
Figure2-8LMTInterface
Table2-1showsthedetaileddescriptionofalltheexternalinterfaces.
Table2-1ProductExternalInterfacesDescription
No.LabelInterface/TerminalInterfacetype/connector
1PWRPowerinterface/1drycontactDCinterface:
ConnectorXCG18T4K1P1-
01+XC18FJJP1-10.5
Sectionareaofcableis1.5mm
2MON485Serial/2drycontacts8-coressocket(IEC60130-9-ED)
3AISGAISGdeviceinterface8-coresaviationsocket
4OPT1eBBUInterfaceLCtypeopticalinterface
5OPT2ReservedLCtypeopticalinterface
6ANT4(TX1/RX1)AntennaTX/RXinterfaceonchannel150OhmDIN-7/16Connector
7ANT3(RX3)AntennaRXinterfaceonchannel350OhmDIN-7/16Connector
8GroundingT erminal-
9ANT2(RX2)AntennaRXinterfaceonchannel250OhmDIN-7/16Connector
2
10ANT1(TX0/RX0)AntennaTX/RXinterfaceonchannel050OhmDIN-7/16Connector
11LMTOperationandMaintenanceInterface8P8CEthernetinterface
2-8
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 17

2.10ProductIndicators

Chapter2ProductOverview
Note:
TherearenoANT2andANT3interfacesforL708andL808.
ZXSDRR8882L268providessixLEDindicators,whicharelocatedattherightbottom sideofthedevice.TheLEDindicatorsareusedtoshowproductworkingstatusandalarm status,asshowninFigure2-9.
Figure2-9ProductIndicators
Table2-2showsthedetailedinformationoftheindicators.
Table2-2ProductIndicatorDescription
NameColorMeaningWorkingMode
RUNGreenRunningstatuslBlinkingevery1.5second:physicallinkinthe
processofinitialization
lBlinkingevery0.07second:thelinkbetween
eBBUandeRRUisintheprocessof
establishment,orthelinkisbroken
lBlinkingevery0.3second:deviceisingood
state
2-9
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 18
ZXSDRR8882L268UserManual
NameColorMeaningWorkingMode
ALMRedAlarmindicatorlSolidON:thereisalarm
lOFF:thereisnoalarm
OPT1GreenOpticalinterface
OPT2GreenOpticalinterface
VSWR1RedTransmission
VSWR2RedTransmission
runningindicator
runningindicator
channel1VSWR
indicator
channel4VSWR
indicator
lSolidON:physicallinkisgood,logicallinkis
abnormal
lOFF:physicallinkisabnormal
lBlinkingevery0.3second:interfaceisingood
state
lSolidON:physicallinkisgood,logicallinkis
abnormal
lOFF:physicallinkisabnormal
lBlinkingevery0.3second:interfaceisingood
state
lSolidON:thereareVSWRalarms
lOFF:thereisnoVSWRalarm
lSolidON:thereareVSWRalarms
lOFF:thereisnoVSWRalarm
2-10
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 19

3.1PhysicalIndices

Chapter3
ProuductTechnicalIndices
TableofContents
PhysicalIndices.........................................................................................................3-1
WorkingEnvironment.................................................................................................3-1
Bandwidth..................................................................................................................3-1
PowerRequirements..................................................................................................
PowerConsumption...................................................................................................3-2
TransmissionIndex....................................................................................................
PerformanceIndices..................................................................................................3-2
ElectromagneticCompatibility....................................................................................3-3
Reliability....................................................................................................................
3-2
3-2
3-6
ItemIndex
Dimension380mmx320mmx140mm(HxWxD)
Weight20kg

3.2WorkingEnvironment

ItemIndex
Temperature-40~55 Working
RelativeHumidity5%~100%
Temperature-55~70 Storage
RelativeHumidity10%~100%
GroundLessthan0.1Ωbetweengroundingterminaland
deviceterminal
Waterproof/DustproofIP65

3.3Bandwidth

ZXSDRR8882L268supports5MHz,10MHz,15MHzand20MHz.
3-1
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 20
ZXSDRR8882L268UserManual
Note:
L708doesnotsupport20MHz.

3.4PowerRequirements

ThepowersupplyoftheZXSDRR8882L268is-48VDC(range:-37VDC~-57VDC).

3.5PowerConsumption

ThemaximumpowerconsumptionofZXSDRR8882L268is330W.

3.6TransmissionIndex

ZXSDRR8882L268connectstoeBBUthroughCPRIinterfaces.Thedetailedinformation oftheCPRIinterfaceisshowninT able3-1.
Table3-1CPRIInterfaceIndex
CPRIinterface2SFP(LC)2x3.072Gbpsor

3.7PerformanceIndices

OperationFrequencyBand
TheoperationradiofrequencybandofZXSDRR8882L268is2500MHz~2570 MHz(uplink)/2620MHz~2690MHz(downlink)
OutputPower
TheTOCoutputpowerofZXSDRR8882L268is2x30W.
ReceiverSensitivity
ThereceiversensitivityofZXSDRR8882L268isshowninT able3-2.
ItemQuantityInterfacetypeSpeedStandard
CPRIV4.1
2x2.4576Gbps
Table3-2ReceiverSensitivity
Channelbandwidth(MHz)
5/10/15/20FRCA1-3inTable3-3-104
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Referencemeasurement
channel
3-2
Referencesensitivitypower
level(dBm)
Page 21
Chapter3ProuductTechnicalIndices
Table3-3FRCParametersforReferenceSensitivityandIn-channelSelectivity
ReferencechannelA1-3
Allocatedresourceblocks25
DFT-OFDMSymbolspersub-frame12
ModulationQPSK
Coderate1/3
Payloadsize(bits)2216
TransportblockCRC(bits)24
CodeblockCRCsize(bits)0
Numberofcodeblocks1
Codedblocksizeincluding12–bitstrellistermination(bits)6732
Totalnumberofbitspersub-frame7200
Totalsymbolspersub-frame3600

3.8ElectromagneticCompatibility

Thedecisionruleusedinthissectionisdescribesasfollows:
1.RuleA lAcommunicationchannelissetupforthetest,anditisalwaysavailableduring
thetest.
lFERoftheforwardchannelandreversechannelarelessthanorequalto1during
thetest.
lWhenthetesttaskaccomplished,equipmentundertest(EUT)worksnormally
underpre-scheduledmethod,thereisnoinformationlossofusercontrolfunction andthesaveddata,andthecommunicationchannelisstillavailable.
lIftheEUTisatransmitteronly ,testshouldbedoneunderidle-mode,andthere
isnounintentionalradiationduringthetest.
2.RuleB lAcommunicationchannelissetupforthetest,anditisalwaysavailableduring
test.
lEUTworksnormallyunderpre-scheduledmethod,thereisnoinformationlossof
usercontrolfunctionandthesaveddata,andthecommunicationchannelisstill available.
lIftheEUTisatransmitteronly ,testshouldbedoneunderidle-mode,andthere
isnounintentionalradiationduringthetest.
3.RuleR
Thereisnodevicedamageorinterference(suchassoftwaremalfunctionorprotection devicemis-operation)duringthetest.TheEUTworksnormallyunderthedened boundaryaftertransientelectromagneticincident.
3-3
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 22
ZXSDRR8882L268UserManual
ElectronicStaticDischargeImmunity
ItemContactdischargeAirdischargeDecisionRule
Basictesting6kV8kVRuleB
Enhancedtesting8kV15kVRuleR
RFElectromagneticFieldRadiationImmunity
RangeFeatureFieldStrengthDecisionRule
80MHz~800MHz80%AM(1kHz)10V/mRuleA
800MHz~960MHz80%AM(1kHz)10V/mRuleA
960MHz~1400MHz80%AM(1kHz)10V/mRuleA
1400MHz~2700MHz80%AM(1kHz)10V/mRuleA
2700MHz~6000MHz80%AM(1kHz)10V/mRuleA
ElectricalFastTransientBurstImmunity
ItemVoltageRepetitionFrequencyDecisionRule
Basictest±1kV5kHzRuleB
Enhancedtest±2kV5kHzRuleB
signalgeneratorwaveform5/50ns
LightningTolerance
SignalTypeNominalRequired
Antennafeederport10kA±5times
The10KAprotectionisguaranteedbytheduplexof
theRFmodule.Anexternallightningprotectionunit
isneededforthehigherprotectionotherthan10KA
DCpowerportexternalSPD20kA±5times,ResidualVoltageislessthan250V .
ShieldedcableisusedfortheR8882remotepower
supply
Signalport—drycontact3KA
Signalport—RS485signal3KA
AISGpower5KA
Signalport—AISG485port3KA
RadiationTransmission
Frequencyrange(MHz)Quasi-peaklimit(dBuV/m)Distance( ((m) )
30~2303010
3-4
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 23
Chapter3ProuductTechnicalIndices
Frequencyrange(MHz)Quasi-peaklimit(dBuV/m)Distance( ((m) )
230~10003710
1G~3G5010
3G~6G5410
PowerConductedTransmission
Sumlimit(dBuV) Frequencyrange(MHz)
Quasi-peakAveragevalue
0.15~0.5056~6646~56
0.50~55646
5~306050
SignalConductedTransmission
Sumlimit Frequencyrange
Quasi-peakAveragevalue
0.15MHz~0.5MHz84dBuV~74dBuV(Voltage)or40
dBuV~30dBuA(Current)
0.5MHz~30MHz74dBuV(Voltage)or30dBuA
(Current)
74dBuV~64dBuV(Voltage)or30
dBuV~20dBuA(Current)
64dBuV(Voltage)or20dBuA
(Current)
RFElectromagneticFieldConductedImmunity
FrequencyrangeV oltageFeatureDecisionRule
0.15MHz~80MHz10V80%AM1kHzRuleA
SurgeImmunity
OpencircuitVoltage Site
TypeWire—WireWire—Ground
Indoor
DCpower0.51
Longdistancewire(wirelengthlonger
than10meters)
Shortdistancewire(wirelengthlessthan
10meters)
11
--
3-5
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 24
ZXSDRR8882L268UserManual

3.9Reliability

MTBF≥34,0000hours
MTTR1hour
Availability≥99.999842%
ItemCharacteristics
3-6
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 25
Chapter4
ProductInstallation
TableofContents
SafetyDescription.....................................................................................................4-1
PreparationBeforeInstallation...................................................................................4-6
MountingOnWall.....................................................................................................4-10
MountingOnPole....................................................................................................
MountingOnGantry.................................................................................................4-21
ConnectingCables...................................................................................................

4.1SafetyDescription

4.1.1SafetyGuide

OnlytheprofessionalpersonnelwhohavepassedthetrainingrelatedtoZXSDRR8882 L268canoperateandmaintaintheequipment.
4-14
4-25
BasicrequirementsonZXSDRR8882L268maintenancepersonnelinclude:
lBefamiliarwithZXSDRR8882L268equipmentprincipleandnetworking; lHoldcertainnetworkoptimizationskill.
Duringtheoperationandmaintenanceoftheequipment,allthesafetyrulesandrelated operationproceduresonthesitemustbestrictlyabidedby,toavoidbodyinjuries orequipmentdamages.Thesafetyprecautionsintroducedinthismanualareonly supplementarytothelocalsafetyspecications.
ZTEshouldinnowaybeliableforanylossesordamagescausedbyviolationof theuniversalsafetyoperationrequirementsorthesafetystandardsfordesigning, manufacturingandusingtheequipment.

4.1.2SymbolDescription

Table4-1showssafetysymbolsanditsmeanings.
Table4-1SafetySymbolsandTheirDescriptions
SafetySymbolsMeaning
Beware!
Bewareofelectrostaticdischarge
4-1
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 26
ZXSDRR8882L268UserManual
Fourtypesofsafetylevelsareavailable:danger,warning,cautionandnote.T otherightof asafetysymbolisthetextdescriptionofitssafetylevel.Underthesymbolisthedetailed descriptionaboutitscontents.Theformatsareasfollows.
SafetySymbolsMeaning
Warnagainstelectricshock
Cautionagainstscald
Bewareoflaser
Becarefulofmicrowave
Danger!
Indicatesanimminentlyhazardoussituationwhich,ifnotavoided,willresultindeathor seriousinjury.Thissignalwordistobelimitedtothemostextremesituations.
Warning!
Thissignmeansthattheremaybeamajororseriousaccident,equipmentdamageor interruptionofkeyservicesifyouignorethissafetywarning.
Caution!
Indicatesapotentiallyhazardoussituationwhich,ifnotavoided,couldresultinminoror moderateinjury.Itmayalsobeusedtoalertagainstunsafepractices.
Note:
ANotestatementisusedtonotifypeopleofinstallation,operation,ormaintenance informationthatisimportant,butnothazard-related.
4-2
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 27

4.1.3SafetyInstructions

ElectricalSafety
Danger!
Neverconnectordisconnectanyhotpowercables.Attheinstantwhenpowercables touchconductors,electricsparksorarcsmayoccur,whichmaycausereoreyeinjury.
Turnoffthepowersupplybeforeinstallingorremovingapowercable.
Makesurethecablesandthecablelabelsmatchthepracticalinstallationconditionsbefore connectingthem.
Warning!
Chapter4ProductInstallation
Donotdrillanyholesonthecabinetonyourown.Improperdrillingmaydamagethewiring andcablesinsidethecabinetandthemetalscrapsproducedduringthedrillingwillcause shortcircuitsinthecircuitboardsiftheyenterthecabinet.
StaticElectricity
Caution!
Thestaticelectricitygeneratedbyhumanbodycandamagetheelectrostatic-sensitive componentsonthecircuitboard,suchasthelargescaleintegratedcircuit(IC).
Accumulatedelectrostaticcharges(ESC)derivefromfrictioncreatedbyhumanbody movements.Inadryenvironment,thestaticvoltagecarriedbyahumanbodycanbe upto30kV ,andcanremaininthehumanbodyforalongtime.Whenanoperatorwho carriesstaticelectricitytouchesacomponent,hewilldischargeelectricitythroughthe component,thusdamagingthecomponent.
Beforetouchinganyequipmentorholdingtheboard,circuitboard,andICchip,wearthe antistaticwriststrapandmaketheotherendofitbewellgrounded.Thishelpsavoid damagingelectrostatic-sensitivecomponentsbythestaticelectricityofhumanbody .
4-3
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 28
ZXSDRR8882L268UserManual
Laser
Donotgazeatthelaserbeamfromtheopticaltransceiverorinsidetheopticalber; otherwise,youreyesmaybedamaged.
HighTemperature
Thesurfacetemperatureofsomedevicesisquitehigh,sodonottouchthemtoavoida scaldinjury.
Warning!
Danger!
HotSurface
No-Touching!
Temperaturesexceedingthelimitsarepermittedprovidedthatthefollowingconditionsare met:
–unintentionalcontactwithsuchapartisunlikely,and
-theparthasamarkingindicatingthatthispartishot.Itispermittedtousethe (IEC60417-5041(DB:2002-10))toprovidethisinformation.
HoistingHeavyObjects
Warning!
Donotwalkaboutrightundertheboomandthehoistedobjectswhentheyarebeing hoisted.
symbol
lWhendisassemblingheavyequipment,ormovingandreplacingequipment,make
surefacilitieswithproperhoistingcapabilityareinplace.
lThepersonnelthathoisttheequipmentshouldhavereceivednecessarytrainingand
acquiredthecorrespondingqualication,andthehoistingtoolsshouldhavebeen checkedandbecomplete.
4-4
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 29
Chapter4ProductInstallation
lMakesurethatthehoistingtoolsarexedrmlytoaxtureorawallthatcanbearthe
weightforthehoisting.
lUsebriefcommandstopreventmisoperation.
Plugging/UnpluggingaModule
Here,modulesincludeboardsandsubracks.
Caution!
lOperatorsmustweartheantistaticwriststrap. lDonotplugamodulewithgreatforcelestthatthepinsonthebackplanebebent. lPlugthemodulerightintotheslotandavoidcontactbetweenthemoduleandthe
circuitfacelestthatanyshortcircuitoccur.
lDonottouchthemodulecircuits,components,connectorsandwiringslotswhen
holdingamodule.
lRFmoduleisveryhotduringoperation,soyoushouldbecarefulon
plugging/unplugging.
Personnel
Caution!
Non-professionalsshouldnotmaintainordebugtheinteriorofanyequipmentunless instructedbyprofessionalsonsite.
Replacingthepartsormodifyingtheequipmentmaygiverisetoextradanger.Therefore, neverreplaceanypartsormodifytheequipmentbyanymeansunlessotherwise authorized.T oensureyoursafety,pleasecontactZTECorporationifyouhaveany problem.

4.1.4HoistingOperationInstructions

IfitisrequiredtohoisteRRUtothetower,refertothefollowinginstructions.
lNaturalconditionsforhoistingoperationaresatised,suchasnofogandhighvisibility .
Thehoistingoperationisprohibitedinwindy,snowy,orrainydays.
lToolsforhoistingoperationareavailable,suchasthehoistingrope(withabearing
capacityof100kg)andthecrownblock,andthecrownblockisrmlyinstalledin appropriatepositiononthetower.
lOpenthepackagetocheckifthecabinetisingoodcondition.Hoistthecabinettothe
toweraftertheinspection.
Performthefollowingstepsforhoistingoperation.
4-5
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 30
ZXSDRR8882L268UserManual
leRRUhandlecannotbeusedtobindthehoistingrope. lPriortohoisting,carefullycheckitagain,includingiftheboundisrmandthebracket
mountingscrewsaretightened.
lItisstrictlyprohibitedtousesteelwireropeasthehoistingrope. lDuringthehoistingprocedure,irrelevantpersonisprohibitedtostandsurroundingthe
tower,especiallyundertheeRRU,toavoidunexpectedinjury.

4.2PreparationBeforeInstallation

4.2.1PersonnelPreparation

Theeldengineeringsupervisorisinchargeofthetrainingandmanagementofinstallation personnel,tomakesuretheinstallationisperformedcorrectlyandcontrolinstallation quality.Theinstallationpersonnelperformtheinstallation.
RequirementsonEngineeringSupervisor
lTheengineeringsupervisorshouldhavequalitycontrolability . lTheengineeringsupervisorshouldhavereceivedcorrespondingZTEtrainingand
obtainedcertication.
lTheengineeringsupervisorshouldbefamiliarwiththematerials,toolsandoperation
methodsusedintheinstallation.
lTheengineeringsupervisorshouldbefamiliarwiththeinstallationowandinstallation
methodsofeachcomponent.
lTheengineeringsupervisorshouldfollowthe“SafetyFirst”principle,toensurethe
smoothcompletionofinstallation.
RequirementsonInstallationPersonnel
lTheinstallationpersonnelshouldhavereceivedcorrespondingZTEtrainingand
obtainedcertication.
lTheinstallationpersonnelshouldbehealthy,havenotdrunkalcohol. lTheinstallationpersonnelshouldfollowthesafetyinstructionsoftools,andusesafety
belts.
lTakecareoftheoperationmachineryandtoolstopreventthemfromfalling. lTheinstallationpersonnelshouldnotwearlooseclothesandslipperyshoes.

4.2.2ContainerofZXSDRR8882L268

ZXSDRR8882L268usescartonsforpacking.TheZXSDRR8882L268cabinetis wrappedbyEPEpolyfoamandthenputintothecarton,asshowninFigure4-1.
4-6
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 31
Figure4-1PackingofZXSDRR8882L268
Chapter4ProductInstallation

4.2.3UnpackingandCheckingFlow

Figure4-2showstheowofunpackingandchecking.RefertoUnpackingandChecking
ManualintheZXSDRR8882L268engineeringmaterialsfordetailedstepsand
precautions.
4-7
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 32
ZXSDRR8882L268UserManual
Figure4-2UnpackingandInspectionFlow

4.2.4InstallationAccessories

AlltherelatedinstallationaccessoriesareshowninT able4-2.
4-8
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 33
Chapter4ProductInstallation
Table4-2InstallationAccessoriesDescription
NameAppearanceDescription
Wall-mountingcomponentsItisusedtomountZXSDR
R8882L268onthewall
PoleMountingClipsItisusedtomountwallmounting
componentsonthepole,and
theZXSDRR8882L268is
mountedonwallmounting
components
Expansionmounting
components
LPUmountingcomponentsItisusedtomountLPUonthe

4.2.5InstallationFlow

Figure4-3showstheinstallationow.
Itisusedtomountthethird
ZXSDRR8882L268onthewall
mountingcomponents
pole
4-9
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 34
ZXSDRR8882L268UserManual
Figure4-3InstallationFlow

4.3MountingOnWall

Prerequisite
BeforeinstallingZXSDRR8882L268,youshouldatleastleavethefollowingspacefor productfuturemaintenance.
lFrontside:600mm lBackside:40mm lleftandrightside:100mm lUPanddownside:250mm
Steps
1.Markoninstallationpositionsbasedonlayoutmarkingtemplateonwall,asshownin
Figure4-4,andthendrillingholes.
4-10
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 35
Figure4-4T emplateHolePosition
Chapter4ProductInstallation
2.Fixthewall-mountingcomponentsontothewallrmlywiththebolts,asshownin
Figure4-5.
Figure4-5InstallingWall-mountingComponents
1.HexBolt
2.SpringWasher
3.FlatWasher
4.InsulationWasher
5.Wall-Mounting components
Thewall-mountingcomponentsisinstalledonthewall,asshowninFigure4-6.
4-11
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
6.InsulationPlate
7.ExpansionBolt
Page 36
ZXSDRR8882L268UserManual
Figure4-6Wall-mountingComponentsOnWall
3.Hungthedeviceonthewall-mountingcomponentsonthenotchdepartment,asshown inFigure4-7.
Figure4-7HungDeviceOnTheWall-mountingComponents
4.MounttheZXSDRR8882L268ontothewall-mountingcomponents,andthenfasten itwiththeM6bolts,asshowninFigure4-8.
4-12
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 37
Figure4-8FasteningZXSDRR8882L268
Chapter4ProductInstallation
1.Insulationwasher2.Springwasher3.Bolt
TheZXSDRR8882L268isinstalledonwall,asshowninFigure4-9.
Figure4-9ZXSDRR8882L268IsInstalledOnWall
–EndofSteps–
4-13
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 38
ZXSDRR8882L268UserManual

4.4MountingOnPole

4.4.1One-To-OneMounting

Steps
1.Fixingthewall-mountingcomponentsandpolecliptogether,asshowninFigure4-10.
Figure4-10FixingWall-mountingcomponentsandPoleClips
2.Fixingthewall-mountingcomponentsandpoleclipsonthepole,asshowninFigure
4-11.
Figure4-11FixingWall-mountingComponentsandPoleClipsOnPole
1.Bolt
2.Springwasher
3.Flatwasher
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
4.Wall-mounting components
5.PoleClips
4-14
Page 39
Chapter4ProductInstallation
3.Hungthedeviceonthenotchpartofthewall-mountingcomponents,asshownin
Figure4-12.
Figure4-12HungtheDeviceOntheWall-mountingComponents
4.Fixingthedeviceonthewall-mountingcomponents,asshowninFigure4-13.
Figure4-13FixingTheDeviceOnTheWall-mountingComponents
ZXSDRR8882L268isinstalledrmlyonthepole,asshowninFigure4-14.
4-15
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 40
ZXSDRR8882L268UserManual
Figure4-14ZXSDRR8882L268IsInstalledOnPole
–EndofSteps–

4.4.2One-To-TwoMounting

Steps
1.Fixingthewall-mountingcomponentsandpolecliptogether,asshowninFigure4-15.
Figure4-15FixingWall-mountingcomponentsandPoleClips
2.Fixingthewall-mountingcomponentsandpoleclipsonthepole,asshowninFigure
4-16.
4-16
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 41
Chapter4ProductInstallation
Figure4-16FixingWall-mountingComponentsandPoleClipsOnPole
1.Bolt
2.Springwasher
3.Flatwasher
4.Wall-mounting components
5.PoleClips
3.Hungthedevicesonthenotchpartofthewall-mountingcomponentsrespectively,as showninFigure4-17.
Figure4-17HungtheDevicesOntheWall-mountingComponents
4.Fixingthedevicesonthewall-mountingcomponents,asshowninFigure4-18.
4-17
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 42
ZXSDRR8882L268UserManual
Figure4-18FixingTheDevicesOnTheWall-mountingComponents
ZXSDRR8882L268areinstalledrmlyonthepole,asshowninFigure4-19.
Figure4-19ZXSDRR8882L268areInstalledOnPole
–EndofSteps–

4.4.3One-To-ThreeMounting

Steps
1.Fixingthewall-mountingcomponentsandpolecliptogether,asshowninFigure4-20.
4-18
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 43
Chapter4ProductInstallation
Figure4-20FixingWall-mountingcomponentsandPoleClips
2.Fixingthewall-mountingcomponentsandpoleclipsonthepole,asshowninFigure
4-21.
Figure4-21FixingWall-mountingComponentsandPoleClipsOnPole
1.Bolt
2.Springwasher
3.Flatwasher
4.Wall-mounting components
5.PoleClips
3.Fixingthethirdwall-mountingcomponentsbyusingtheexpansioncomponentstothe othertwoones,asshowninFigure4-22.
4-19
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 44
ZXSDRR8882L268UserManual
Figure4-22FixingTheThirdWall-mountingComponents
4.Hungdevicesonthenotchpartofthewall-mountingcomponentsrespectively,as showninFigure4-23.
Figure4-23HungtheDevicesOntheWall-mountingComponents
ZXSDRR8882L268areinstalledrmlyonthepole,asshowninFigure4-24.
4-20
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 45
Figure4-24ZXSDRR8882L268AreInstalledOnPole
Chapter4ProductInstallation
–EndofSteps–

4.5MountingOnGantry

Steps
1.Assemblethegantry.
a.InstalltheverticalshaftandthebottomplatebyusingtheM5x16screw,asshown
inFigure4-25.
Figure4-25InstallingTheVerticalShaftAndTheBottomPlate
4-21
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 46
ZXSDRR8882L268UserManual
b.FastentheverticalshaftandthecoverplatebyusingtheM5x16screw,asshown
inFigure4-26.
Figure4-26FastenTheVerticalShaftAndTheCoverPlate
c.InstalltheslantedrackbyusingtheM5x16screw,asshowninFigure4-27.
Figure4-27InstallingTheSlantedRack
2.Drillholes
a.Accordingtotheengineeringdesigndrawing,determinetheinstallationposition
ofthegantryandmarkinstallationholesbyusingthemarkingpen.Figure4-28 showstheinstallationholesofthegantry.
4-22
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 47
Figure4-28MarkingTheDrillingHolesPosiotion
Chapter4ProductInstallation
b.Drillholesbyusingtheelectricpercussiondrill(drillbit:φ12)attheplaceswhere
installationholesaremarked.Atthesametime,usethevacuumcleanertoremove thedustgeneratedduringthedrillingofholes.
c.Puttheexpansionsleeveontothemetalconeoftheexpansionbolt,fastenthe
nutslightly,striketheexpansionboltintotheinstallationholebyusingtherubber hammer,fastenthenuttightlytomaketheboltfullyexpanded,andthenremove thenut,asshowninFigure4-29.
Figure4-29InstallingTheExpansionBolt
3.Installthegantry.
4-23
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 48
ZXSDRR8882L268UserManual
Ifthegantryisinstalledontheconcreteoor,usetheM10x100expansionbolt,as showninFigure4-30;ifthegantryisinstalledonthewoodenoor,usetheM10x40 tappingscrew,asshowninFigure4-31.
Figure4-30InstallingTheGantryOnTheConcreteFloor
Figure4-31InstallingTheGantryOnTheWoodenFloor
4.Installthewall-mountingcomponentsonthegantry .
5.InstalltheZXSDRR8882L268onthewall-mountingcomponents.Thedeviceis installedrmlyonthegantry,asshowninFigure4-32.
4-24
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 49
Figure4-32ZXSDRR8882L268IsInstalledOnGantry
Chapter4ProductInstallation
–EndofSteps–

4.6ConnectingCables

4.6.1ConnectionofExternalCables

Table4-3describestheconnectionofZXSDRR8882L268externalcables.
Table4-3ConnectionofZXSDRR8882L268ExternalCables
CabletypeConnectionrelationDescription
PowercableConnectstheZXSDRR8882
L268powerinterfacetothe
powersupplyequipment
interface
Oneendiscircular6-core
cableconnector(hole)with
plasticcover,theotherendis
reservedforpowercable.The
lengthofcableisbasedonthe
engineeringsurvey.
4-25
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 50
ZXSDRR8882L268UserManual
GroundingcableConnectsoneZXSDRR8882
L268groundbolttothecopper
bar
FiberConnectstoeBBUandfor
ZXSDRR8882L268cascading
too.
EnvironmentmonitorcableConnectstheZXSDRR8882
L268environmentmonitor
interfacetotheexternalmonitor
componentsorthedrycontact.
AISGcableConnectstheZXSDRR8882
L268debugginginterface
(AISG)
Thegroundingcableismade
upofstrandsofame-retardant
wire.Thecrosssectional
areaofZXSDRR8882L268
groundingcableis25mm
Copperlugsarecrimpedatboth
endsofthegroundingcable.
Devicesupportssinglemode/
multi-modeopticalbercable.
Fortheenvironmentmonitor
cable,endAisPINheader.
EndB,with3mlengthintotal,
ismadedependingontheeld
engineeringconditions.
AISGisusedtoprovidethe
RS485signalandtheDC
voltageoutput.
2
.
AntennajumperConnectsZXSDRR8882L268
tomainfeeder

4.6.2ExternalCableInstallationFlow

Figure4-33liststheinstallationowofexternalcable.Thisowcanbeadjustedbasedon
actualconditions.
TheRFjumperusuallyuses
thenished1/2″jumperwith
2mlength.Thejumpercan
becustomizeddependingon
actualconditions.Oneend
ofthejumperisNconnector
(male)andtheotherendisDIN
connector(female).
4-26
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 51
Figure4-33ExternalCableInstallationFlow
Chapter4ProductInstallation

4.6.3InstallingPowerCable

Context
-48VDCisusedforZXSDRR8882L268cabinet.Apowercableisprovidedforthe equipment.Oneendiscircular6-corecableconnector(hole)withplasticcover,theother endisreservedforpowercable.Thelengthofcableisbasedontheengineeringsurvey.
4-27
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 52
ZXSDRR8882L268UserManual
Figure4-34showsthestructureofZXSDRR8882L268powercable.
Figure4-34StructureofPowerCable
Table4-4describesthecoloranddenitionofinnercoreofthepowercable.
Table4-4ColorandDenitionofInnerCoreofthePowerCable
CorecolorDenitionSignalDescription
Blue-48V-48VGND
Blue-48V-48VGND
Black-48VGND-48Vground
Black-48VGND-48Vground
WhiteNODE_IN+Drycontact
BrownNODE_IN-Drycontact
Note:
1.Ifthetwo-corecableisadopted,thebluecorecablestandsfor-48Vandtheblack corecablestandsfor-48VGND.
2.Ifthefour-corecableisadopted,thetwobluecorecablesconnectedinparallelstand for-48Vandtheblackcorecablesconnectedinparallelstandfor-48VGND.
Steps
1.ConnectendAofpowercablewithDCINinterfacelocatedatthebottomofZXSDR R8882L268.
2.StriptheprotectivecoatofendBandconnectittolightningprotectionunitaccording tocoloroftheinnercorecable.
3.MakewaterproofprotectionofendB.
4.Attachlabelsatbothendsofthepowercable.
5.Fixthepowercable.
–EndofSteps–
4-28
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 53

4.6.4InstallingGroundingCable

Context
ThegroundingcableofZXSDRR8882L268ismadeupofstrandsofame-retardantwire. Thecrosssectionalareaofgroundingcableis25mm endsofthegroundingcable,asshowninFigure4-35.
Figure4-35StructureofGroundingCable
Steps
1.CoverandxacopperlugontheagroundingboltoftheZXSDRR8882L268cabinet.
Chapter4ProductInstallation
2
.Copperlugsarecrimpedatboth
2.Connecttheothercopperlugtotheearth-networkingcopperbarandxitwithbolts, asshowninFigure4-36.
Figure4-36GroundingCopperBar
3.Attachthelabelonthegroundingcable.
4.Measurethegroundingresistanceandmakesureitislessthan5ohms.
–EndofSteps–

4.6.5InstallingFiberBetweeneBBUandeRRU

Prerequisite
TheZXSDRR8882L268unithasbeeninstalledandsecurelyfastened.
4-29
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 54
ZXSDRR8882L268UserManual
Context
Figure4-37showsberconnectionbetweenZXSDRR8882L268andeBBU.
Figure4-37FiberthatconnectsZXSDRR8882L268andeBBU
1.Outdoorsealingcomponent
WhileconnectingaeBBUtoZXSDRR8882L268,makesurethatthebasebandRFber interface(LC1/2)ofZXSDRR8882L268isconnectedtotheopticalinterfaceconnectorof eBBU.
Steps
1.Attachlabelsatbothendsoftheber.
2.AdjustthesideofendAwiththecolormarkandinsertberinterface,andscrewdown thenuts,asshowninFigure4-38.
Figure4-38InstallingFibers
1.Colormark
3.ConnectendAofthebertothebaseband-RFberinterface(LC1/2)ofZXSDRR8882 L268.ConnectendBoftheber,whichisaDLCconnector,totheeBBUoptical connector.
4.ScrewdowntheoutdoorsealcomponentatendAforwaterproof.
–EndofSteps–
4-30
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 55

4.6.6InstallingFibersBetweeneRRUs

Prerequisite
TheZXSDRR8882L268cabinetforcascadehasbeeninstalledandsecurelyfastened.
Context
Figure4-39showsthestructureofcascadebersbetweenZXSDRR8882L268s.
Figure4-39CascadeberbetweenZXSDRR8882L268s
1.Outdoorsealingcomponent
Chapter4ProductInstallation
OninterconnectionbetweenZXSDRR8882L268s,connecttwobaseband-RFberinter­faces(OPT1/2)fortwoZXSDRR8882L268sbyusingaber.
Steps
1.Attachlabelsatbothendsoftheber.
2.Maketheequipmentandthesidewithcolormarkfacetoyou.Inserttheberconnector intoopticalinterfaceandscrewdownthenuts,asshowninFigure4-40.
Figure4-40InstallingFibers
1.Colormark
4-31
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 56
ZXSDRR8882L268UserManual
3.ConnectendAofthebertobaseband-RFberinterface(OPT1/2)ofZXSDRR8882 L268.ConnectendBofthebertobaseband-RFinterface(OPT1/2)oftheother ZXSDRR8882L268.
4.Screwdowntheoutdoorsealcomponentforwaterproof.
–EndofSteps–

4.6.7InstallingEnvironmentMonitorCable

Prerequisite
TheZXSDRR8882L268cabinethasbeeninstalledandsecurelyfastened.
Context
Theenvironmentmonitorcableprovidesa485interface,usedforZXSDRR8882L268 environmentmonitor.Italsoprovidesfourextensionaccessesforexternaldrycontact monitor.
EndAiscircular8-coreplugandendBismadedependingonactualconditions.Thetotal lengthis3m.Figure4-41showsthestructureofenvironmentmonitorcable.
Figure4-41EnvironmentMonitorCable
Theconnector,connectingtheenvironmentmonitoringcabletoZXSDRR8882L268,is 8-corestraightweldedconnector(pin)mountedonpanel.Theconnectorappearanceis showninFigure4-42.
Figure4-42AppearanceofEnvironmentMonitorCable
ThecableconnectorpinsandconnectionareshowninT able4-5.
Table4-5CablePinDescription
PinCorecolorSignalDescription
PIN1BrownDrycontactinput,positivepolarity
4-32
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 57
Chapter4ProductInstallation
PinCorecolorSignalDescription
PIN2YellowDrycontactinput,negativepolarity
PIN3BlueDrycontactinput,positivepolarity
PIN4WhiteDrycontactinput,negativepolarity
PIN5GreenPositiveRS485bussignal
PIN6GreyNegativeRS485bussignal
PIN7RedPositiveRS485bussignal
PIN8BlackNegativeRS485bussignal
Note:
ConnecttherstdrycontactofeRRUtooutdoorDClightningprotectionbox.
Steps
1.ConnectendAofenvironmentmonitorcabletoenvironmentmonitorinterfaceof ZXSDRR8882L268cabinet.
2.ConnectendBofenvironmentmonitorcabletoexternalmonitorpartordrycontact.
3.AttachthelabelsonendB.
–EndofSteps–

4.6.8InstallingAISGControlCable

Context
AISGisusedtocontroltheelectrical-adjustmentantenna.
Figure4-43showsthestructureofAISGcontrolcable.
4-33
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 58
ZXSDRR8882L268UserManual
Figure4-43StructureofAISGControlCable
Table4-6describesthemeaningofsequencenumberofAISGcontrolcable.
Table4-6MeaningofSequenceNumberofAISGControlCable
PinsatendAPinsatEndBNameMeaning
PIN3PIN1RS485BRS485-
PIN5PIN2RS485ARS485+
PIN6PIN3,PIN4DCDCoutput
PIN7PIN5,PIN6DCRTNDCRTN
PIN1,PIN2,PIN4,PIN8NCNull
Steps
1.ConnectendAtoZXSDRR8882L268debugginginterface(AISG)andscrewdown thebolt.
2.ConnectendBtothecontrolinterfaceofelectricaladjustmentantennaandscrew downthebolt.
–EndofSteps–

4.6.9InstallingAntennaFeederJumper

Context
RFjumperisacablesegmentthatconnectsmainfeederandantennafeederinterfaceof ZXSDRR8882L268cabinet.TheRFjumperisinstalledafterthemainfeederisinstalled completely.
TheRFjumperusuallyusesthenished1/2″jumperwith2mlength.Thejumpercanbe customizeddependingonactualconditions.
Figure4-44showsinstallationpositionsofRFjumper.
4-34
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 59
Figure4-44InstallationPositionofRFJumper
Steps
Chapter4ProductInstallation
1.ConnectDINconnector(male)ofRFjumperwithDINconnector(female)ofmain feeder.
2.ConnectDINconnector(male)ofRFjumperwithRFantennainterfaceofcabinet.
3.Sealtheconnectorstomakethemwaterproof.
–EndofSteps–
4-35
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 60
ZXSDRR8882L268UserManual
Thispageintentionallyleftblank.
4-36
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 61

Figures

Figure2-1ZTEDistributedeNodeBSolution.............................................................2-2
Figure2-2ProductLocation......................................................................................
Figure2-3ProductOverallAppearance....................................................................2-5
Figure2-4StarNetworkingMode.............................................................................2-6
Figure2-5OperateandMaintainSystemRemotely..................................................2-6
Figure2-6OperateandMaintainSystemLocally......................................................2-7
Figure2-7ProductExternalInterfacesandGroundingT erminal................................2-7
Figure2-8LMTInterface..........................................................................................2-8
Figure2-9ProductIndicators....................................................................................
Figure4-1PackingofZXSDRR8882L268...............................................................4-7
Figure4-2UnpackingandInspectionFlow...............................................................4-8
Figure4-3InstallationFlow.....................................................................................4-10
Figure4-4T emplateHolePosition..........................................................................4-11
Figure4-5InstallingWall-mountingComponents...................................................4-11
Figure4-6Wall-mountingComponentsOnWall......................................................
Figure4-7HungDeviceOnTheWall-mountingComponents.................................4-12
Figure4-8FasteningZXSDRR8882L268..............................................................4-13
4-12
2-3
2-9
Figure4-9ZXSDRR8882L268IsInstalledOnWall...............................................4-13
Figure4-10FixingWall-mountingcomponentsandPoleClips................................4-14
Figure4-11FixingWall-mountingComponentsandPoleClipsOnPole..................4-14
Figure4-12HungtheDeviceOntheWall-mountingComponents...........................
Figure4-13FixingTheDeviceOnTheWall-mountingComponents.......................4-15
Figure4-14ZXSDRR8882L268IsInstalledOnPole.............................................4-16
Figure4-15FixingWall-mountingcomponentsandPoleClips................................4-16
Figure4-16FixingWall-mountingComponentsandPoleClipsOnPole..................4-17
Figure4-17HungtheDevicesOntheWall-mountingComponents.........................4-17
Figure4-18FixingTheDevicesOnTheWall-mountingComponents......................4-18
Figure4-19ZXSDRR8882L268areInstalledOnPole...........................................4-18
Figure4-20FixingWall-mountingcomponentsandPoleClips................................
Figure4-21FixingWall-mountingComponentsandPoleClipsOnPole..................4-19
Figure4-22FixingTheThirdWall-mountingComponents.......................................4-20
Figure4-23HungtheDevicesOntheWall-mountingComponents.........................4-20
4-15
4-19
I
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 62
ZXSDRR8882L268UserManual
Figure4-24ZXSDRR8882L268AreInstalledOnPole..........................................4-21
Figure4-25InstallingTheVerticalShaftAndTheBottomPlate..............................
Figure4-26FastenTheVerticalShaftAndTheCoverPlate..................................4-22
Figure4-27InstallingTheSlantedRack..................................................................4-22
Figure4-28MarkingTheDrillingHolesPosiotion....................................................4-23
Figure4-29InstallingTheExpansionBolt...............................................................4-23
Figure4-30InstallingTheGantryOnTheConcreteFloor......................................
Figure4-31InstallingTheGantryOnTheWoodenFloor........................................4-24
Figure4-32ZXSDRR8882L268IsInstalledOnGantry.........................................4-25
Figure4-33ExternalCableInstallationFlow...........................................................4-27
Figure4-34StructureofPowerCable.....................................................................4-28
Figure4-35StructureofGroundingCable...............................................................4-29
Figure4-36GroundingCopperBar.........................................................................4-29
Figure4-37FiberthatconnectsZXSDRR8882L268andeBBU.............................
Figure4-38InstallingFibers....................................................................................4-30
Figure4-39CascadeberbetweenZXSDRR8882L268s......................................4-31
Figure4-40InstallingFibers....................................................................................4-31
4-21
4-24
4-30
Figure4-41EnvironmentMonitorCable..................................................................4-32
Figure4-42AppearanceofEnvironmentMonitorCable..........................................4-32
Figure4-43StructureofAISGControlCable..........................................................
Figure4-44InstallationPositionofRFJumper........................................................4-35
4-34
II
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 63

Tables

Table2-1ProductExternalInterfacesDescription.....................................................2-8
Table2-2ProductIndicatorDescription.....................................................................
Table3-1CPRIInterfaceIndex.................................................................................3-2
Table3-2ReceiverSensitivity...................................................................................3-2
Table3-3FRCParametersforReferenceSensitivityandIn-channel
Selectivity................................................................................................3-3
Table4-1SafetySymbolsandTheirDescriptions.....................................................4-1
Table4-2InstallationAccessoriesDescription...........................................................4-9
Table4-3ConnectionofZXSDRR8882L268ExternalCables...............................4-25
Table4-4ColorandDenitionofInnerCoreofthePowerCable.............................4-28
Table4-5CablePinDescription..............................................................................
Table4-6MeaningofSequenceNumberofAISGControlCable.............................4-34
2-9
4-32
III
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 64
Thispageintentionallyleftblank.
Tables
IV
SJ-20110104194923-001|2011-01-19(R1.0)ZTEProprietaryandCondential
Page 65

Glossary

AISG
-AntennaInterfaceStandardsGroup
CPRI
-CommonPublicRadioInterface
CRC
-CyclicRedundancyCheck
LTE
-LongTermEvolution
MTBF
-MeanTimeBetweenFailures
MTTR
-MeanTimeToRepair
QAM
-QuadratureAmplitudeModulation
QPSK
-QuadraturePhaseShiftKeying
RF
-RadioFrequency
SDR
-SoftwareDenedRadio
eBBU
-evolvedBaseBandUnit
eNodeB
-EvolvedNodeB
eRRU
-evolvedRemoteRadioUnit