ZXSDRR8860EGU858UserManual
NameShapeFunction
Clampassembly
forpolemounted
installation
Mountingbracket
assemblyfor
polemounted
installation
Forthepolewith
1or2R8860E
GU858polemounted
installation
Forthepolewith3
R8860EGU858pole
mountedinstallation
MountingBaseUsedbypole
mountedinstallation
ofR8860EGU858
MountingPieceUsedbyxingonthe
pole
4-22
SJ-20101210110401-001|2010-12-06ZTEProprietaryandCondential
NameShapeFunction
Chapter4Installation
Lightningpretector
piece
ExpansionpieceForthepolewith
ProtectionshadeToshieldR8860E
Usedbypole
mountedinstallation
ofLightningpretector
box
thethirdR8860E
GU858polemounted
installation
GU858fromdirect
sunlight
4.5.2.2WallMountedInstallation
Fixtheassemblyforwallmountedinstallationonthewall,andthenxR8860EGU858on
theassemblywithbolts,asshowninFigure4-7.
4-23
SJ-20101210110401-001|2010-12-06ZTEProprietaryandCondential
ZXSDRR8860EGU858UserManual
Figure4-7WALLMOUNTEDINSTALLA TIONFORR8860EGU858
4.5.2.3PoleMountedInstallation(PoleMountingKit)
Ifthereareonly1or2R8860EGU858s,usetheclampassemblytoxit/themonthepole,
asshowninFigure4-8.
4-24
SJ-20101210110401-001|2010-12-06ZTEProprietaryandCondential
Chapter4Installation
Figure4-8POLEMOUNTEDINST ALLATIONFOR1OR2R8860EGU858s
Ifthereare3R8860EGU858s,usethemountingbracketassemblytoxthemonthepole,
asshowninFigure4-9.
Figure4-9POLEMOUNTEDINSTALLATIONFOR3R8860EGU858s
4.5.2.4PoleMounting(UniversalSheet-MetalKit)
InthesingleR8860EGU858solutiontheunitisxedonthepolebyanuniversalmounting
kit,asshowninFigure4-10.
4-25
SJ-20101210110401-001|2010-12-06ZTEProprietaryandCondential
ZXSDRR8860EGU858UserManual
Figure4-10TheSingleR8860EGU858MountingSolution
InthedoubleR8860EGU858solutiontheunitisxedonthepolebyanuniversalmounting
kit,asshowninFigure4-11.
Figure4-11TheDoubleR8860EGU858MountingSolution
InthetripleR8860EGU858solutiontheunitisxedonthepolebyanuniversalmounting
kit,asshowninFigure4-12.
4-26
SJ-20101210110401-001|2010-12-06ZTEProprietaryandCondential
Figure4-12TheTripleR8860EGU858MountingSolution
Chapter4Installation
4.5.3R8860EGU858Installation
TheinstallationofR8860EGU858includestwoparts,thatis,mainpartinstallationand
cableinstallation.TheinstallationowisshowninFigure4-13.
4-27
SJ-20101210110401-001|2010-12-06ZTEProprietaryandCondential
ZXSDRR8860EGU858UserManual
Figure4-13R8860EGU858INSTALLA TIONFLOW
4.5.3.1WallMountedInstallationforR8860EGU858
Steps
1.DrillholesonthewallwithholingtemplateaccordingtotheR8860EGU858installation
positionspeciedintheengineeringdesigndocuments,andinstalltheexpansion
bolts.Thedepthoftheholeshouldbeabout60mm.Theholingtemplateisshownin
Figure4-14.
4-28
SJ-20101210110401-001|2010-12-06ZTEProprietaryandCondential
Figure4-14HOLINGTEMPLATE
Chapter4Installation
2.Assemblethewallmountedinstallationassembly,asshowninFigure4-15.Fixthe
assemblyonthewallwithbolts.
4-29
SJ-20101210110401-001|2010-12-06ZTEProprietaryandCondential
ZXSDRR8860EGU858UserManual
Figure4-15ASSEMBLINGWALL-MOUNTEDINSTALLA TIONASSEMBLY
1.Expansionbolt
2.Insulationplate
3.Wall-mountingplate
4.Insulationflange
5.Flatwasher
6.Springwasher
7.Nut
3.HangtheR8860EGU858cabinetonthewallmountedinstallationassembly(alignit
withtheclamps),andxthecabinettotheassemblywith2M6bolts,asshownin
Figure4-16.
4-30
SJ-20101210110401-001|2010-12-06ZTEProprietaryandCondential
Figure4-16FIXINGTHECABINET
Chapter4Installation
1.Wall-mountinginstallat
ioncomponentsclamp
2.Screw
3.Fixationboard
–EndofSteps–
4.5.3.2PoleMountedInstallationforR8860EGU858PoleMountingKit
4.5.3.2.1Installing1R8860EGU858
Steps
1.Install2setsofclampassembliesonthepole,andfastenthemjustalittle.Adjustthe
distancebetweenthepoleclampassembliesaccordingtothescrewholesandthen
fastenM8bolts.Finally,fastenthescrewsonthepoleclampassemblies,asshown
inFigure4-17.
4-31
SJ-20101210110401-001|2010-12-06ZTEProprietaryandCondential
ZXSDRR8860EGU858UserManual
Figure4-17INSTALLINGCLAMPASSEMBL Y
1.M8nut
2.Springwasher
3.Flatwasher
4.Insulationflange
5.Wall-mounting
installationassemblies
6.Insulationboard
7.Hoop
8.Bolt
9.Pole
10.Plainwasher
11.Springwasher
12.NutHoop
13.Hoop
2.HangtheR8860EGU858cabinetonthewallmountedinstallationassembly(alignit
withtheclamps),andxthecabinettotheassemblywith2M6bolts,asshownin
Figure4-18.
4-32
SJ-20101210110401-001|2010-12-06ZTEProprietaryandCondential
Figure4-18FIXINGTHECABINET
Chapter4Installation
1.Screw2.Clipboard3.Fixationboard
–EndofSteps–
4.5.3.2.2Installing2R8860EGU858s
Steps
1.Install4setsofclampassembliesonthepole,andfastenthemjustalittle,asshown
inFigure4-19.
4-33
SJ-20101210110401-001|2010-12-06ZTEProprietaryandCondential
ZXSDRR8860EGU858UserManual
Figure4-19INSTALLINGCLAMPASSEMBL Y
1.Nut
2.Springwasher
3.Plainwasher
4.Hoop
5.Bolt
Note
Wheninstalling2R8860EGU858s,decidethelengthofclampassemblybolts
accordingtotheresultofengineeringsurvey.Ifthepolediameterisintherange60
mm~90mm,useboltswiththelength80mm.Ifthepolediameterisintherange90
mm~120mm,useboltswiththelength130mm.
2.Assemble2setsofwallmountedinstallationassembliesandfastentheM8bolts,as
showninFigure4-20.Fastentheboltsoftheclampassemblies.
4-34
SJ-20101210110401-001|2010-12-06ZTEProprietaryandCondential
Chapter4Installation
Figure4-20ASSEMBLINGWALL-MOUNTEDINSTALLA TIONASSEMBLY
1.Bolt
2.Springwasher
3.Plainwashe
4.Insulationflange
5.Wall-mounting
installationassemblies
6.Insulationwasher
7.Hoop
3.HangtheR8860EGU858cabinetonthewallmountedinstallationassembly(alignit
withtheclamps),andxthecabinettotheassemblywith2M6bolts,asshownin
Figure4-21.
Figure4-21FIXINGTHECABINET
1.Screw2.Wall-mounting
SJ-20101210110401-001|2010-12-06ZTEProprietaryandCondential
installationassemblies
4-35
ZXSDRR8860EGU858UserManual
3.Fixationboard
–EndofSteps–
4.5.3.2.3Installing3R8860EGU858s
Steps
1.Install4setsofmountingbracketassembliesonthepole,backtoback,andfasten
themjustalittle,asshowninFigure4-22.
Figure4-22INSTALLINGMOUNTINGBRACKETASSEMBLY
1.Fixationplate
2.Nut
3.Springwasher
4.Plainwasher
2.Assemble3setsofwallmountedinstallationassembliesandfastentheM8bolts,as
showninFigure4-23.Fastentheboltsoftheclampassemblies.
4-36
SJ-20101210110401-001|2010-12-06ZTEProprietaryandCondential
5.Bolt
Chapter4Installation
Figure4-23ASSEMBLINGWALL-MOUNTEDINSTALLA TIONASSEMBLY
1.Fixationplate
2.Largeinsulationplate
3.Wall-mounting
installationassemblies
4.Insulationflange
5.Plainwasher
6.Springwasher
7.Bolt
3.HangtheR8860EGU858cabinetonthewallmountedinstallationassembly(alignit
withtheclamps),andxthecabinettotheassemblywith2M6bolts,asshownin
Figure4-24.
Figure4-24FIXINGTHECABINET
1.Screw2.Wall-mounting
installationassemblies
4-37
SJ-20101210110401-001|2010-12-06ZTEProprietaryandCondential
3.Fixationboard