ZTE R8854S2600 User Manual

Page 1
Chapter6
Post-InstallationCheck
ItemNo.Description
Groundingand
Waterproong
CableRouting
1Installtheequipmentaccordingtothesitesurvey'sdesigndrawing
andensurethattheequipmentiswithin45°protectionofthe
lightningarrester.
2EnsurethattheinstallationsequenceofRRUpartsiscorrectand
installthemainequipmentsecurely.
3Ensurethatthecrimpingclipcloselypressesthenakedpartofthe
powercable'sshieldinglayerinthemaintenancewindow.
4EnsurethattheRRU,outdoorpowercable,andfeeder'sgrounding
pointcomplywithrelevantrequirements.
5Checktheantennafeeder's"1+3+3"waterproofprotectionand
ensurethatthemaintenancewindowissecurelyinstalledtoavoid
waterpenetration.
6Ensurethatthegroundingcard'scableisrouteddownwards,the
anglebetweenthegroundingleadandthefeederisnotlargerthan
15°.Removetherustontheterminalofthegroundingcablebefore
itisconnected.
7Ensurea20cmverticalcableroutingforRRUconnectorsand
antennaconnectors,andthattheprotectioncapsofallunusedRRU
connectorsaretightlyscrewed.
8Ensurethattheremainingantennafeedersarewoundinto"S"or"8"
shapeandtheremainingbersarewoundonthewirespooland
storedinaproperplace.
9Ensurethatawatertrapismadeforthecablethatisledintothe
equipmentroomandthelowestpointofthewatertrapis10to20cm
lowerthanthebottomedgeoftheinletportatthefeederwindow.
10Ensurethatoutdoorcablesarebundledbyusingblacktiesanda
sectionof2-3threads(3-5cm)isreserved.
11Ensurethatallcablesareconnectedsecurelyandlabelsarehanged
properlyatbothends.
12Ensurethatcablesareroutedproperlyandstraightly,withoutany
crossing,obviousups,downsandskews,orywire.
6-1
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 2
ZXSDRR8854HardwareInstallation
Thispageintentionallyleftblank.
6-2
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 3
Chapter7
Power-onInspection
TheZXSDRR8854ispoweredonafterinstallation.Ifanyerrorsarefound,youmust troubleshoottheZXSDRR8854.
Context
Figure7-1showsthepower-oninspectionowoftheZXSDRR8854.
Figure7-1Power-onInspectionFlow
Steps
1.ConnectthepowersupplyequipmenttotheZXSDRR8854,orswitchontheaircircuit breakerofthelightningprotectionbox.
7-1
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 4
ZXSDRR8854HardwareInstallation
2.Powerthedeviceonat30-secondintervalsinorderofcellstoavoidcurrentsurge. Checkwhetherornotthebercablesinacellareconnectedproperlythroughthe indicatorsontheBBU.
–EndofSteps–
7-2
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 5
Chapter8
Closure
Afterinstallation,performthefollowingoperations:
lPuttoolsinorder.
Putthetoolsusedduringtheinstallationbackinrightpositions.
lCollectunexpectedmaterials.
Collectunexpectedmaterialsandhandthemovertothecustomer.
lRemovewastematerials.
Removewastematerialsandcleantheenvironment.
lCompletetheinstallationreport.
Completetheinstallationreportandsubmittheinstallationreporttothepersonin charge.
Ifthesiteisoperatingproperly,notifytheoperationandmaintenanceengineersthat theinstallationiscompleted.
8-1
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 6
ZXSDRR8854HardwareInstallation
Thispageintentionallyleftblank.
8-2
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 7
Chapter9
InstallingtheDCJunction Box
ThisproceduredescribeshowtoinstalltheDCjunctionbox(ODCPD1).
TheZXSDRR8854DCpowerconnectorcannotbeconnectedtothepowercablewiththe sectionalareaof10mm
2
mm
or16mm externalpowersupplyistoolong,aDCjunctionbox(ODCPD1)isneededtoconnectthe powercabletothatwiththesectionareaof4mm
2
mustbeusedbecausethedistancebetweentheZXSDRR8854andan
2
or16mm
Steps
InstallingtheODCPD1
1.FixthemountingbracketoftheODCPD1totheZXSDRR8854withfourscrews,see
Figure9-1.
2
.Ifthepowercablewiththesectionalareaof10
2
or6mm
2
.
Figure9-1FixingtheMountingBracketoftheODCPD1
9-1
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 8
ZXSDRR8854HardwareInstallation
Caution!
TheODCPD1canbeinstalledbythebackortheside.Theinstallationpositionofit shouldensurethatitcanbeopenedata90°angleatleastforeasymaintenance.
2.FixtheODCPD1tothemountingbracketwithtwoscrewsincludedwiththeODCPD1, seeFigure9-2.
Figure9-2FixingtheODCPD1JunctionBox
InstallingthePowerCable
3.OpenthecoverplateoftheODCPD1,seeFigure9-3.
Figure9-3OpeningtheCoverPlateoftheODCPD1
9-2
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 9
Chapter9InstallingtheDCJunctionBox
4.Maketheendsofthepowercableaccordingtothediagramontheinnersideofthe coverplate,seeFigure9-4.CrimptheOTterminalsoftheexternalDCpowerinput cableandtheDCpowercableconnectoroftheRRU.Thepartbetweentheshielded layerandtheOTterminalmustbewrappedwithinsulationtape.
Figure9-4MakingaDCPowerCableConnector
5.PasstheDCpowercablethroughthewaterproofplugoftheODCPD1andxittothe correctterminal,seeFigure9-5.
Figure9-5SecuringtheDCPowerCable
6.ClosethecoverplateoftheODCPD1andevenlytightenthesixwaterproofscrewson thecoverplate,seeFigure9-6.
9-3
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 10
ZXSDRR8854HardwareInstallation
Figure9-6ClosingtheCoverPlateoftheODCPD1
Caution!
Thescrewsmustbefastenedtopreventwaterintrusion.
7.ConnecttheotherendoftheDCpowercabletotheRRUandtheexternalpower supplyequipmentrespectively.
8.Bundleandlabelthecable.
InstallingtheProtectiveGroundingCable
9.InstallthegroundingcablefromtheRRUtotheODCPD1,andthegroundingcable fromtheODCPD1tothegroundingbar,seeFigure9-7.
9-4
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 11
Chapter9InstallingtheDCJunctionBox
Figure9-7ConnectingtheProtectiveGroundingCabletotheGroundingBusbar (ODCPD1)
–EndofSteps–
9-5
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 12
ZXSDRR8854HardwareInstallation
Thispageintentionallyleftblank.
9-6
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 13
Chapter10
WaterproongOutdoor Connectors
Waterproongoutdoorconnectorsisa"1+3+3"process,thatis,wrappingonelayerof
PVCinsulatingtape,threelayersofwaterproofinsulatingtape,andthreelayersofPVC
insulatingtapearoundaconnector.
ThePVCinsulatingtapeisusedtopreventconnectorsfromdamage,ageing,andwater ingress.
Steps
1.Cleanthecableconnectorandensurethatnodirtoroilstainexistsontheconnector.
2.Wrapalayerofelectricinsulationtape.
Afteracableconnectorisconnected,wraptheconnectorwiththeinsulationtape downwardsinthedirectionthattheconnectoristightened,witheachroundcovering halfofthepreviousround,seeFigure10-1.Ensurethatthepartabout10mmtothe connectorendiswrappedwiththeinsulationtape.Whenwrappingtheconnector, stretchthetapewithproperforce.
Figure10-1WrappingaLayerofElectricInsulationTape
3.Wrapthreelayersofwaterprooftape.
10-1
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 14
ZXSDRR8854HardwareInstallation
Extendthewaterprooftapeuntilitswidthis50%to75%oftheoriginalwidth.
Wrapthreelayersofwaterprooftapeinthedirectionthattheconnectoristightened topreventtheconnectorfromloosening.Wraptheconnectorupwardsfortherst layer,downwardsforthesecondlayer,andthenupwardsagainforthethirdlayer, witheachroundcoveringaboutonethirdofthepreviousroundtopreventtheingress ofrainwater,seeFigure10-2.Donotcutoffthetapebeforetheconnectorisfully wrappedwiththreelayers.Ensurethatthepartwrappedwiththewaterprooftapeis morethan20mminlength.
Afterwrappingtheconnectorwiththewaterprooftape,gripandpinchthewrappedpart repeatedlywithbothhandstomakethewaterprooftapesecurelystucktothecable andthecableconnector.
Figure10-2WrappingWaterproof/UVResistanceTape
Caution!
Theoutermostlayeroftapeshallbeappliedfromthebottomuptoavoidwater penetration.
4.WrapthreelayersofUVresistancetape.
WraptheconnectorwiththreelayersofUVresistancetapeinthesamedirection ofwrappingwaterprooftape,seeFigure10-2.Payattentiontothefollowingwhen wrappingacable:
lTheUVresistancetapeshouldbestretchedandwrappedwithproperforceto
preventitfrombeingstretchedtoomuch.
lTheupper-layertapecovers1/2thebottom-layertapeinlength. lThewrappinglengthoftheUVresistancetapemustbe10mmlongerthanthat
ofthewaterprooftape.Wrapthreelayers.
Afterwrapthreelayers,gripandpinchboththeUVresistancetapeandwaterproof tapetoensurethattheyaresecurelyadhered.
5.Securethetape'stwoends.
10-2
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 15
Chapter10WaterproongOutdoorConnectors
Afterapplyingthetape,useblackultraviolet-prooftiestosecurelybundlethetape's twoends,asshowninFigure10-3.Usethediagonalplierstocutofftheexcessive tiesandreserveasectionof3mmatthemouth.Thisavoidstapeexpansionunder hightemperature.
Figure10-3FixingBothEnds
–EndofSteps–
10-3
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 16
ZXSDRR8854HardwareInstallation
Thispageintentionallyleftblank.
10-4
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 17
Chapter11
InstallingaGantry
Thisproceduredescribeshowtoinstallagantry.
Steps
AssemblingaGantry
1.Fixtwopoststotwosidesofthebaseframewith12M5×16screws,seeFigure11-1.
Figure11-1AssemblingthePostandBaseFrame
2.FixthetopbeamtothepostswithfourM5×16screws,seeFigure11-2.
Figure11-2TighteningthePostandTopBeam
3.InstallthetwosupportingplateswithsixM5×16screwsrespectively ,seeFigure11-3.
11-1
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 18
ZXSDRR8854HardwareInstallation
Figure11-3AssemblingtheSupportingPlate
DrillingHolesandInstallingExpansionBolts
4.Marktheholepositionswithadrillingtemplateandmarkerpen.
5.Drillholesatthemarkedpositionswithanelectricpercussiondrill(12mmindiameter) andremovethechippingswithavacuumcleaner,seeFigure11-4.
Figure11-4DrillingHolesandInstallingExpansionBolts
FixingtheGantry
6.Fixthegantryinoneofthefollowingways:
If...Then...
InstallthegantryonaconcretebaseplateFixthegantrywithM10×100expansionbolts,seeFigure
11-5.
InstallthegantryinashelterFixthegantrywithM10×40self-tappingscrews,see
Figure1 1-6.
11-2
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 19
Figure11-5FixingtheGantrytoaConcreteBaseplate
Chapter11InstallingaGantry
Figure11-6FixingtheGantrytoaShelter
–EndofSteps–
11-3
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 20
ZXSDRR8854HardwareInstallation
Thispageintentionallyleftblank.
11-4
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 21
Chapter12
LabelingSpecications
Labelsincludeindoorandoutdoorlabels.
lOutdoorlabelsarehangtagsthataredeliveredwiththedevice. lIndoorlabelsaretheselfadhesivepaper-printedlabelsthatmayneedtobeproduced
atsiteifnecessary .
Labelsmustmeetthefollowingrequirements:
lThespecialpasterofZTECorporationmustbeusedforpaperlabels. lContentsonrackrowlabelsandcolumnlabelsshouldmeettheengineeringdesign
requirements.
lBoardsshouldnotbelabeledandidentiersonaboardshouldnotbealtered. lAlllabelsshouldbeattachedtofacethesamedirection.Thesidethatindicates
wherethecableisconnectedtoshouldfaceupwardortowardstheoperationand maintenancepositionfortheconvenienceofbeingread.
lAllcablessuchasthepowercable,groundingcable,transmissioncable,andfeeder
shouldbelabeledatbothends.
lForopticalbers,networkcables,andtrunkcables,anindoorlabelshouldbepasted
20mmawayfromtheconnectoratbothendseach.
lOutdoorlabelsshouldbesecuredwithcabletiesatthesameheightanddirection.
12-1
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 22
ZXSDRR8854HardwareInstallation
Thispageintentionallyleftblank.
12-2
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 23
Figures
Figure1-1ZXSDRR8854InstallationFlow...............................................................1-1
Figure2-1DeviceHoisting........................................................................................
Figure2-2BindstheRRU.........................................................................................2-3
Figure2-3DoNotOpentheAirtightPart...................................................................2-4
Figure2-4DoNotInstallAnyPortUpwards..............................................................2-5
Figure2-5DoNotInstalltheRRUHorizontally.........................................................2-6
Figure2-6RecommendedSpaceforInstallingZXSDRR8854(inmm).....................2-7
Figure2-7MinimumSpaceforInstallingZXSDRR8854(inmm)..............................2-8
Figure4-1Wall-MountedInstallation.........................................................................
Figure4-2Pole-MountedInstallationofaSingleRRU..............................................4-2
Figure4-3Pole-MountedInstallationofTwoRRUs...................................................4-2
Figure4-4PoleHoop-MountedInstallationofaSingleRRU.....................................4-3
Figure4-5Gantry-MountedInstallation.....................................................................4-4
Figure4-6L-shapeSupportInstallation....................................................................4-5
Figure4-7InstallationPositionsofExpansionBolts..................................................
Figure4-8ExternalViewofanExpansionBolt..........................................................4-7
Figure4-9InstallinganExpansionBolt.....................................................................4-8
2-2
4-1
4-6
Figure4-10SecuringtheFixingClamp.....................................................................4-9
Figure4-11InstallingtheRRUSupport...................................................................4-10
Figure4-12InstallingtheRRUSupporttotheFixingClamp....................................4-10
Figure4-13SecuringtheRRU................................................................................
Figure4-14ChannelSteelPole-MountedInstallation..............................................4-12
Figure4-15AngleSteelPole-MountedInstallation..................................................4-12
Figure4-16AssemblingthePoleMountAssembly.................................................4-13
Figure4-17InstallingthePoleMountAssembly(1)................................................4-14
Figure4-18InstallingthePoleMountAssembly(2)................................................4-15
Figure4-19InstallingtheRRUSupport...................................................................4-15
Figure4-20InstallingtheRRUonthePoleMountAssembly..................................4-16
Figure4-21SecuringtheRRU................................................................................
Figure4-22AssemblingthePoleComponent........................................................4-18
Figure4-23InstallingthePoleComponent(1)........................................................4-18
Figure4-24InstallingthePoleComponent(2)........................................................4-19
4-11
4-16
I
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 24
ZXSDRR8854HardwareInstallation
Figure4-25InstallingtheRRUSupport...................................................................4-20
Figure4-26InstallingtheRRUsonthePoleMountAssembly.................................
Figure4-27SecuringtheRRUs..............................................................................4-22
Figure4-28InstallingtheRRUSupport..................................................................4-24
Figure4-29InstallingtheFixingCliptothePole.....................................................4-26
Figure4-30MountingtheZXSDRR8854...............................................................4-26
Figure4-31TighteningtheCaptiveScrew..............................................................
Figure4-32InstallingtheAdapterPlate..................................................................4-29
Figure4-33SecuringtheFixingClamp...................................................................4-30
Figure4-34InstallingtheRRUSupport...................................................................4-31
Figure4-35InstallingtheRRUontheGantry..........................................................4-31
Figure4-36SecuringtheFixingClamp...................................................................4-34
Figure4-37InstallingtheRRUSupport...................................................................4-35
Figure4-38InstallingtheRRUontheL-shapeSupport..........................................
Figure5-1CableConnectionDiagram......................................................................5-3
Figure5-2ConnectingtheProtectiveGroundingCabletotheGroundingBusbar
(Directly).................................................................................................5-4
4-21
4-27
4-35
Figure5-3MakingaFeederConnector.....................................................................5-5
Figure5-4InstallingAntennaFeederCables............................................................5-6
Figure5-5ZXSDRR8854AntennaFeederConnectionDiagram..............................5-7
Figure5-6InstallingaMonitoringCable....................................................................5-8
Figure5-7InstallingtheAISGCable.........................................................................5-9
Figure5-8Openthemaintenancewindow..............................................................
5-10
Figure5-9Wirestrippingthepowercable...............................................................5-11
Figure5-10Insertthecrimpedtubularterminal.......................................................5-1 1
Figure5-11Unscrewthecrimpingclip....................................................................5-12
Figure5-12Insertthepowercable..........................................................................5-12
Figure5-13ConnectingthePowerCabletotheGroundingKit...............................5-14
Figure5-14ConnectingthePowerCabletotheDCPD...........................................5-14
Figure5-15Openthecrimpingclip.........................................................................5-15
Figure5-16Removethewhitedustcap..................................................................
5-15
Figure5-17Inserttheopticalcable.........................................................................5-16
Figure5-18Securetheopticalcable.......................................................................5-17
Figure7-1Power-onInspectionFlow........................................................................7-1
Figure9-1FixingtheMountingBracketoftheODCPD1...........................................9-1
Figure9-2FixingtheODCPD1JunctionBox............................................................9-2
II
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 25
Figure9-3OpeningtheCoverPlateoftheODCPD1................................................9-2
Figures
Figure9-4MakingaDCPowerCableConnector......................................................
Figure9-5SecuringtheDCPowerCable.................................................................9-3
Figure9-6ClosingtheCoverPlateoftheODCPD1..................................................9-4
Figure9-7ConnectingtheProtectiveGroundingCabletotheGroundingBusbar
(ODCPD1)..............................................................................................9-5
Figure10-1WrappingaLayerofElectricInsulationTape........................................10-1
Figure10-2WrappingWaterproof/UVResistanceT ape..........................................10-2
Figure10-3FixingBothEnds..................................................................................10-3
Figure11-1AssemblingthePostandBaseFrame..................................................11-1
Figure11-2TighteningthePostandT opBeam.......................................................
Figure11-3AssemblingtheSupportingPlate..........................................................11-2
Figure11-4DrillingHolesandInstallingExpansionBolts........................................11-2
Figure11-5FixingtheGantrytoaConcreteBaseplate...........................................11-3
Figure11-6FixingtheGantrytoaShelter...............................................................11-3
9-3
11-1
III
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 26
Thispageintentionallyleftblank.
Figures
IV
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 27
Tables
Table2-1InstrumentsandMetersList......................................................................2-6
Table4-1AccessoriesforWall-MountedInstallation..................................................
Table4-2AccessoriesforSingle-RRUPole-MountedInstallation............................4-12
Table4-3AccessoriesforTwo-RRUPole-MountedInstallation...............................4-17
Table4-4InstallationAccessoriesofPoleHoop-MountedInstallationModeofa
SingleRRU...........................................................................................4-23
Table4-5AccessoriesforGantry-MountedInstallation............................................4-28
Table4-6AccessoriesforL-shapeSupportInstallation...........................................4-33
Table5-1AntennaFeederCableInstallation.............................................................5-5
4-6
V
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 28
Thispageintentionallyleftblank.
Tables
VI
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential
Page 29
Glossary
AISG
-AntennaInterfaceStandardsGroup
BBU
-BaseBandUnit
DC
-DirectCurrent
MON
-Monitor
PVC
-PolyvinylChloride
RRU
-RemoteRadioUnit
VII
SJ-20160405141455-003|2018-01-03(R1.3)ZTEProprietaryandCondential