ZKTECO PV10M/R User Manual

User Manual
PV10M/R Near-infrared Palm Device
Version: 1.0
Date: June 2020
1
Preface
Thank you for choosing our product PV10M/R Near-infrared Palm Device. Please read this User Manual carefully
before use.
We strongly believe that Palm Vein Device brings you and your customers an excellent user experience and will
uplift your Brand Image and the Management to a higher level.
Considering the stability of the product quality and service life, please do not intentionally dismantle the pr
or modify the system settings without professional instructions. For further queries, please contact the local
dealers.
oduct
Content
1. Introduction ........................................................................................................................................................................................................ 1
2. Dimensions .......................................................................................................................................................................................................... 2
3. Technical Specications .....................................................................................
4. Technical Features ........................................................................................................................................................................................... 6
5. Installation Procedure .................................................................................................................................................................................... 7
6. Maintenance and Cleanline
7. FAQ ....................................................................................................................................................................................................................... 20
ss Guidelines ........................................................................................................................................ 19
.......................................................................................... 4
1
1. Introduction
PV10M/R is a touchless device which is used to capture the palm and vein features. It uses a near-infrared ll light,
a wide dynamic image sensor, and an aspherical distortion-free camera system. It can capture the palm and vein
images under the palm skin, thus oering an excellent anti-spoong performance.
It has a built-in high-performance, low-power-consumption processor with a frequency up to 4
interface for power supply and communication, supporting the mainstream operating system.
By combining with the ZKPalm SDK, customers can easily develop a palm recognition system.
00MHz, a USB
2
2. Dimensions
PV10R
3
PV10M
Connector pinout
(7pin 1.25mm)
Pin 1 +5 V
Pin 2 GND
Pin 3 Shield GND
Pin 4 USB D-
Pin 5 USB D+
Pin 6 Reserved
Pin 7 Reserved
4
3. Technical Specications
Feature Specications
Sensor
H/W
OS
Grayscale 256 levels
Image Size 480 * 640 pixels
Distortion Rate Less than 1%
Connector 7-pin 1.25mm USB 2.0
Power Consumption 0.5W (Standby) / 1.5W (Operating)
Interface USB 2.0 (High speed)
Power Requirements USB 5V
Temperature -10°C to 45°C / 14°F to 113°F
Humidity 0 to 90% RH
Lighting Environment Enrollment <800 Lux; Authentication <2000 Lux
Dimensions
Windows Windows XP / Windows 7 / Windows10 (32/64bits)
Android Android 4.1 or higher version
PV10M : 52.4 * 52.4 * 16.8mm (±1 mm)
PV10R : 41.5 * 34 mm (Radius*Height)
5
Recognition Method
1:1 and 1:N
Certications
ZKPalm SDK
Recognition Angle Roll ± 60°, Pitch ± 30°
Capacity 6,000 templates
Accuracy FRR=0.68% when FAR=0.001%
Recognition Time <300ms (Quad-core Cortex-A9 up to 1.6GHz)
CE, FCC, RoHS