Beforeyou begin
1. Preparing door
Door Thickness O Screws P Screws
38 - 48 mm 40 mm 20 mm
Note: I f the door is thicker than 38-48 mm, this lock will not be availab le.
2. Determining Handing
The hand of a door is deter mined from the secure side of the door. The term "secure" means the side from
which you u nl oc k an d en te r.
G G
Lef t hand, o pen inwa rd Righ t hand, o pen inwa rd
G G
Lef t hand, o pen out ward Ri ght han d, open ou tward
Note: Please install the mortise (G) accord in g to t he a bove pic tu res.
3
Sta ndpoi nt
Cautions
1. New lock is defined as always open mode until it was unlocked once by mifare card.
2. Please swipe authorised card, time sync card, room card at first for the new lock.
3. The lock is equipped with mechanical keys for manual unlocking. Remove the
mechanical keys from the package and keep them in a safe place.
4. To power on the lock, four alkaline AA batteries (not included) are required.
Non-alk aline and rechargeable batteries ARE NOT RECOMMENDED.
5. Do not remove batteries when the lock is in working state.
6. When battery power is low, the lock will beep to remind user to renew the batteries.
Please do not mix up positive and negative while replacing batter y.
7. Avoid contac ting with corrosive substances, and do not hang objects on the handle.
8. The software within the lock manages the RFID cards, for more details refer to the
software user manual.
9. If there are any questions, please do not hesitate to contact the seller.
4