P r o d uc t Na m e a n d M o d e l Num b e r U s e r M an u al
User Manual
InBio160/260/460 Pro Access Control Panel
Date: April 2021
Doc Version: 1.0
English
Thank you for choosing our product. Please read the instructions carefully
before operation. Follow these instructions to ensure that the product is
functioning properly. The images shown in this manual are for illustrative
purposes only.
For further details, please visit our Company’s website
www.zkteco.eu .
Pa g e | 1 C o p y rig h t © 2 0 2 0 Z K T E C O C O ., L T D . A l l r ig h t s r es e r v ed .
InBio160/260/460 Pro Access Control Panel User Manual
Copyright © 2021 ZKTECO CO., LTD. All rights reserved.
Without the prior written consent of ZKTeco, no portion of this manual can be copied or forwarded in any
way or form. All parts of this manual belong to ZKTeco and its subsidiaries (hereinafter the "Company" or
"ZKTeco").
Trademark
is a registered trademark of ZKTeco. Other trademarks involved in this manual are owned by
their respective owners.
Disclaimer
This manual contains information on the operation and maintenance of the ZKTeco equipment. The
copyright in all the documents, drawings, etc. in relation to the ZKTeco supplied equipment vests in and is
the property of ZKTeco. The contents hereof should not be used or shared by the receiver with any third
party without express written permission of ZKTeco.
The contents of this manual must be read as a whole before starting the operation and maintenance of
the supplied equipment. If any of the content(s) of the manual seems unclear or incomplete, please
contact ZKTeco before starting the operation and maintenance of the said equipment.
It is an essential pre-requisite for the satisfactory operation and maintenance that the operating and
maintenance personnel are fully familiar with the design and that the said personnel have received
thorough training in operating and maintaining the machine/unit/equipment. It is further essential for
the safe operation of the machine/unit/equipment that personnel has read, understood and followed the
safety instructions contained in the manual.
In case of any conflict between terms and conditions of this manual and the contract specifications,
drawings, instruction sheets or any other contract-related documents, the contract
conditions/documents shall prevail. The contract specific conditions/documents shall apply in priority.
ZKTeco offers no warranty, guarantee or representation regarding the completeness of any information
contained in this manual or any of the amendments made thereto. ZKTeco does not extend the warranty
of any kind, including, without limitation, any warranty of design, merchantability or fitness for a
particular purpose.
ZKTeco does not assume responsibility for any errors or omissions in the information or documents which
are referenced by or linked to this manual. The entire risk as to the results and performance obtained from
using the information is assumed by the user.
ZKTeco in no event shall be liable to the user or any third party for any incidental, consequential, indirect,
special, or exemplary damages, including, without limitation, loss of business, loss of profits, business
interruption, loss of business information or any pecuniary loss, arising out of, in connection with, or
Page | 1 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
InBio160/260/460 Pro Access Control Panel User Manual
relating to the use of the information contained in or referenced by this manual, even if ZKTeco has been
advised of the possibility of such damages.
This manual and the information contained therein may include technical, othe
r inaccuracies or
typographical errors. ZKTeco periodically changes the information herein which will be incorporated into
new additions/amendments to the manual. ZKTeco reserves the right to add, delete, amend or modify the
information contained in the manual from time to time in the form of circulars, letters, notes, etc. for
better operation and safety of the machine/unit/equipment. The said additions or amendments are
meant for improvement /better operations of the machine/unit/equipment and such amendments shall
not give any right to claim any compensation or damages under any circumstances.
ZKTeco shall in no way be responsible (i) in case the machine/unit/equipment malfunctions due to any
non-compliance of the instructions contained in this manual (ii) in case of operation of the
machine/unit/equipment beyond the rate limits (iii) in case of operation of the machine and equipment in
conditions different from the prescribed conditions of the manual.
The product will be updated from time to time without prior notice. The latest operation procedures
and relevant documents are available on http://www.zkteco .eu
If there is any issue related to the product, please contact us.
ZKTeco Europe
Address
Ctra. Fuencarral, 44. Ed. 1.
Alcobendas, Madrid. Spain
For business-related queries, please write to us at sales@zkteco.eu .
To know more abo
ut our global branches, visit www.zkteco.eu .
Page | 2 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
InBio160/260/460 Pro Access Control Panel User Manual
About the Company
ZKTeco is one of the world’s largest manufacturer of RFID and Biometric (Fingerprint, Facial, Finger-vein)
readers. Product offerings include Access Control readers and panels, Near & Far-range Facial Recognition
Cameras, Elevator/floor access controllers, Turnstiles, License Plate Recognition (LPR) gate controllers and
Consumer products including battery-operated fingerprint and face-reader Door Locks. Our security
solutions are multi-lingual and localized in over 18 different languages. At the ZKTeco state-of-the-art
700,000 square foot ISO9001-certified manufacturing facility, we control manufacturing, product design,
component assembly, and logistics/shipping, all under one roof.
The founders of ZKTeco have been determined for independent research and development of biometric
verification procedures and the productization of biometric verification SDK, which was initially widely
applied in PC security and identity authentication fields. With the continuous enhancement of the
development and plenty of market applications, the team has gradually constructed an identity
authentication ecosystem and smart security ecosystem, which are based on biometric verification
techniques. With years of experience in the industrialization of biometric verifications, ZKTeco was
officially established in 2007 and now has been one of the globally leading enterprises in the biometric
verification industry owning various patents and being selected as the National High-tech Enterprise for 6
consecutive years. Its products are protected by intellectual property rights.
About the Manual
This manual introduces the operations of the InBio160/260/460 Pro Access Control Panel.
All figures displayed are for illustration purposes only. Figures in this manual may not be exactly
onsistent with the actual products.
c
Page | 3 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
InBio160/260/460 Pro Access Control Panel User Manual
Window names, menu items, data table, and field names are inside square
level menus are separated by forwarding slashes. For example,
Document Conventions
Conventions used in this manual are listed below:
GUI Conventions
For Software
Convention Description
Bold font Used to identify software interface names e.g. OK, Confirm, Cancel
>
Folder.
For Device
Convention Description
Multi-level menus are separated by these brackets. For example, File > Create >
< >
[ ]
Button or key names for devices. For example, press <OK>
brackets. For example, pop up the [New User] window
Multi-
/
[File/Create/Folder].
Symbols
Convention Description
his implies about the notice or pays attention to, in the manual
T
The general information which helps in performing the operations faster
he information which is significant
T
are taken to avoid danger or mistakes
C
The statement or event that warns of something or that serves as a cautionary
example.
Page | 4 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
InBio160/260/460 Pro Access Control Panel User Manual
Table of Contents
1 SAFETY INSTRUCTIONS ........................................................................................................................... 6
IMPORTANT S ECURITY I NSTRUCTIONS ............................................................................................................... 6
INSTALLATION I NSTRUCTIONS ........................................................................................................................... 7
2 SYSTEM INTRODUCTION ......................................................................................................................... 9
SYSTEM FUNCTIONAL PARAMETERS .................................................................................................................. 9
PRODUCT TECHN ICAL PARAMETERS ................................................................................................................. 9
CONTROL PANEL I NDICATORS ......................................................................................................................... 10
3 INSTALLATION AND CONNECTION ....................................................................................................... 11
INSTALLATION P ROCEDURE ............................................................................................................................ 11
INSTALLATION OF A CCESS CONTROL PANEL W IRES .......................................................................................... 12
CONTROL PANEL S YSTEM INSTALLATION ......................................................................................................... 13
CONTROL PANEL C ONNECTION T ERMINALS .................................................................................................... 14
CONNECTION WITH DOOR SENSORS , EXIT SWITCHES , AUXILIARY INPUT DEVICES , AND PC485 EXTENSION
COMMUNICATION ....................................................................................................................................................... 17
CONNECTION WITH READERS ......................................................................................................................... 20
RELAY OUTPUT CONNECTION ......................................................................................................................... 22
ACCESS CONTROL O PE R ATOR PANEL S YSTEM P OWER S UPPLY S TRUCTURE ...................................................... 24
4 EQUIPMENT COMMUNICATION ............................................................................................................ 26
ACCESS CONTROL N ETWORKING W IRES AND W IRING ..................................................................................... 26
TCP/IP C OMMUNICATION .............................................................................................................................. 27
RS485 C OMMUNICATION .............................................................................................................................. 27
DIP S WITCH S ETTINGS ................................................................................................................................... 28
ZKPANELWEB ............................................................................................................................................... 31
5 STATEMENT ON THE RIGHT TO PRIVACY ............................................................................................... 38
6 ECO-FRIENDLY OPERATION ................................................................................................................... 39
Page | 5 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
InBio160/260/460 Pro Access Control Panel User Manual
1 Safety Instructions
Important Security Instructions
1. Read and follow the instructions carefully before operation. Please keep the instructions for future
reference.
2. Accessories: Please use the accessories recommended by the manufacturer or delivered with the
product. Other accessories are not recommended, including major alarming systems and
monitoring systems. The primary alarming and monitoring system should comply with the local
applicable fire-prevention and security standards.
3. Installation cautions: Do not place this equipment on an unstable table, tripod mount, support, or
base, lest the equipment falls and get damaged or any other undesirable outcome resulting in
severe personal injuries. Therefore, it is essential to install the equipment as instructed by the
manufacturer.
4. All peripheral devices must be grounded.
5. No external connection wires can be exposed. All the connections and idle wire ends must be
wrapped with insulating tapes to prevent any damage to the equipment by accidental contact of
the exposed wires.
6. Repair: Do not attempt to have an unauthorized repair of the equipment. Disassembly or
detachment is risky and likely to cause shock. All repairs should be done by a qualified technician.
7. If any of the following cases arise, disconnect the power supply from the equipment first and
intimate the technician immediately.
The power cord or connector is damaged.
Any liquid or material spilled into the equipment.
The equipment is wet or exposed to bad weather (rain, snow, etc.).
If the equipment cannot work properly, even if it is operated as instructed, please be sure to adjust
only the control components specified in the operating instructions. Incorrect adjustments on
other control components may cause damage to the equipment; even the equipment may fail to
operate permanently.
The equipment falls, or its performance changes dramatically.
8. Replacing components: If it is necessary to replace a component, only the authorized technician
can replace the accessories specified by the manufacturer.
9. Security inspection: After the equipment is repaired, the technician must conduct security
inspection to ensure proper working of the equipment.
Page | 6 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
InBio160/260/460 Pro Access Control Panel User Manual
10. Power supply: Operate the equipment with only the type of power supply indicated on the label.
Contact the technician for any uncertainty about the type of power supply.
Violation of any of the following cautions is likely to result in personal injury or equipment
failure. We will not be responsible for the damages or injuries caused thereby.
Before installation, switch off the external circuit (that supplies power to the system), including
locks.
Before connecting the equipment to the power supply, ensure the output voltage is within the
specified range.
Never connect the power before completion of installation.
Installation Instructions
1. The conduits of wires under relay must match with the metal conduits; other wires can use PVC
conduits, to prevent failure caused by rodent damage. The Control panel is designed with proper
antistatic, lightning-proof, and leakage-proof functions, ensure its chassis and the AC ground wire
are correctly connected and the AC ground wire is grounded physically.
2. It is recommended not to plug/unplug connection terminals frequently when the system is
powered on. Be sure to unplug the connection terminals before starting any relevant welding job.
3. Do not detach or replace any control panel chip without permission, and an unpermitted
operation may cause damage to the control panel.
4. It is recommended not to connect any other auxiliary devices without permission. All non-routine
operations must be communicated to our engineers in advance.
5. A control panel should not share the same power socket with any other large-current device.
6. It is preferable to install card readers and buttons at the height of 1.4 to 1.5m above the ground
or subject to customers’ usual practice for proper adjustment.
7. It is advised to install control panels at places where maintenance is easy, like a weak electric
well .
8. It is strongly recommended that the exposed part of any connection terminal should not be
longer than 4mm , and specialized clamping tools may be used to avoid short-circuit or
communication failure resulting from accidental contact with excessively exposed wires.
9. To save access control event records, export the data periodically from control panels.
10. Prepare countermeasures according to application scenarios for unexpected power failure, like
selecting power supply with UPS .
11. To protect the access control system against the self-induced electromotive force generated by an
electronic lock at the instant of switching off/on, it is necessary to connect a diode in parallel
Page | 7 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
InBio160/260/460 Pro Access Control Panel User Manual
(please use the FR107 delivered with the system) with the electronic lock to release the
self-induced electromotive force during onsite connection for application of the access control
system.
12. It is recommended that an electronic lock and a control panel should use separate power supplies.
13. It is recommended to use the power supply delivered with the system as the control panel power
supply.
14. In a place with substantial magnetic interference, galvanized steel pipes or shielded cables are
recommended, and proper grounding is required.
Page | 8 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
InBio160/260/460 Pro Access Control Panel User Manual
2 System Introduction
The Access Control management system is a new modernized security management system, which is an
effective measure of security and protection management. It is mainly used to manage the entrances and
exits of highly secured places, such as banks, hotels, equipment rooms, offices, smart communities, and
factories.
System Functional Parameters
High-speed 32-bit 1.2GHz CPU, 128M RAM, and 256M Flash.
Embedded LINUX operating system.
One-door/two-door two-way access or four-door one-way access.
Fingerprint capacity: 20,000.
A maximum of 60,000 cardholders and 100,000 offline event records.
Support of multiple Wiegand card formats and a password keypad, compatible with various types
of cards.
Use Ethernet and RS485 industrial bus dual communication technology, for reliable communications.
Control Panel with a watchdog (hardware) built in to prevent a crash.
Over-current, over-voltage, and inverse-voltage protection for the input of the power supply to
the control panel.
Over-current protection for the power supply to card readers.
Instant over-voltage protection for all input/output ports.
Instant over-voltage protection for communication ports.
Product Technical Parameters
Working Power supply: Rated voltage 12V (±20%) DC, rated current is 2A.
Working environment: Temperature 0°C to 45°C; Humidity 20% to 80%.
Electronic lock relay output: The maximum switching voltage is 12V(DC); The maximum switching
current is 2A.
Auxiliary relay output: The maximum switching voltage is 12V(DC); The maximum switching
current is 1.25A.
The detachable connection terminals are made of alloy-steel non-magnetic flange materials.
Outline dimensions of the control PCB: 181mm(length) × 106mm (width) for InBio160/260 Pro;
226mm (length) × 106mm (width) for InBio460 Pro.
External box dimensions: 350(L)mm × 300(W)mm × 90(H)mm.
Valve regulated lead-acid battery:
Constant voltage charge voltage regulation
Page | 9 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
InBio160/260/460 Pro Access Control Panel User Manual
Cycle use : 14.5V~14.9V(25)
Initial current: less than 2.88A1
Standby use: 13.6V~13.8V(25)
Capacity: 12V, 7.2Ah/20hr
Battery Type: LC-RA127R2T1
Battery Caution:
Do not charge in a gas tight container.
Do not short the battery terminals.
Do not incinerate.
Flush with water at once if contact is made with electrolyte (Acid).
Do not attempt to disassemble the battery.
Control Panel Indicators
When the InBio160/260/460 Pro is powered on, normally the POWER indicator (red) is lit constantly, the
RUN indicator (green) shall flash slowly (indicating the system is normal), and other indicators are all off.
LINK indicator (green): indicates proper TCP/IP connection if it is lit constantly;
ACT indicator (yellow): indicates transmission of TCP/IP data if it flashes;
EXT RS485 (TX) indicator (yellow): indicates sending of 485 data if it flashes;
EXT RS485 (RX) indicator (green): indicates receiving of 485 data if it flashes;
CARD indicator (yellow): indicates input of Wiegand signal if it is lit.
Indicator Diagram:
Figure 2-1 Indicators in the InBio460 Pro
Page | 10 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
InBio160/260/460 Pro Access Control Panel User Manual
3 Installation and Connection
Installation Procedure
Appearance and Internal of the panel box:
Installation steps for the control panel:
Page | 11 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
InBio160/260/460 Pro Access Control Panel User Manual
Installation of Access Control Panel Wires
+12V Power line
TCP/IP Network communication wire
RS485 Network communication wire
Control Panel
Door sensor
Exit button
wiegand
card reader
Outdoor
Figure 3-1 Access Control Panel Wire Installation Diagram
Remarks:
• Ensure the power supply is disconnected before connecting the wires; otherwise, it may cause
severe damage to the equipment.
• The access control wires must be separated according to heavy and light current; the control
panel wires, electronic lock wires, and exit button wires must run through their casing pipes,
respectively.
Indoor
Indoor wiegand card reader