Zibro SRE 179E user manual

Page 1
SRE 179 E
3
2
6
5
FIN
4
>
u
1
=
MANUEL D'UTILISATION
GEBRAUCHSANWEISUNG
BRUGSANVISNING
INSTRUCCIONES DE USO
OPERATING MANUAL
ISTRUZIONI D’USO
BRUKSANVISNING
GEBRUIKSAANWIJZING
BRUKSANVISNING
2
10
20
30
40
50
60
70
80
90
Page 2
3
PAGE
PLIANTE
2
6
5
FIN
5
4
>
u
FALTBLATT
FOLDEUDSIDE
HOJA DESPLEGABLE
AUKI TAITETTU SIVU
FOLD-OUT PAGE
PIEGHEVOLE
UTBRETTSIDE
1
=
E E E E E E E E E E E E E E E E E E E E E
UITVOUWBLAD
UTVIKNINGSSIDA
-
EMC
-
LV
Page 3
Dear Sir, Madam,
Congratulations with your purchase of the Zibro, the number one brand among
movable heaters. You have purchased a first-class quality product, which will
serve you for many years to come. This, of course, provided you use the heater
correctly. Please read these Directions for Use first, to ensure maximum lifetime
for your Zibro.
Your heater comes with a 48-month manufacturer’s warranty on all defects in
material or workmanship.
We wish you much warmth and comfort with your Zibro.
Yours sincerely,
PVG International b.v.
Customer Service Department
1 READ THE DIRECTIONS FOR USE FIRST.
2 IN CASE OF ANY DOUBT, CONTACT YOUR ZIBRO DEALER.
3 BEFORE YOU START READING, FOLD OUT THE LAST PAGE. E E E E E E E E E E
4
50
Page 4
GENERAL DIRECTIONS FOR USE
Below you will find the main steps to be taken for using your Zibro. For more details, please refer to the MANUAL (pages 53 ff.).
Remove all packaging materials (Fig. A).
1
Fill the removable tank 7 (refer to Section B, Fig. D).
2
Insert the plug into the wall-socket.
3
MAIN COMPONENTS
A
Front plate
B
Grid
C
Base plate
4
Lid for removable tank
E
Operation panel
F
Handle
G
Removable tank
H
Air filter
Ignite the heater using the
4
If required, change the temperature using the adjustment keys
5
(refer to Section E).
Switch off the heater by pressing the
6
key M (refer to Section D).
key M.
The first time you ignite your heater it will smell
like ’new’ for a short time.
Store your fuel in a cool and dark place.
Fuel has a limited shelf life. Start every heating
season with renewed fuel.
The right quality of fuel will be assured, when you
use Zibro Extra or Zibro Kristal for your heater.
If you change to another brand and/or type of
parrafin oil, you must first finish up all the remaining fuel in the heater.
I
Vent filter
J
Thermostat
K
Plug + cord
L
Information display
M
N
O
P
Q
R
S
T
key
Childproof lock
Adjustment keys (time and temperature)
TIMER
SAVE key
Indicator lights
EXTENSION
Air quality control system
E E E E E E E E E E E E E E E E E E E E E E E
4
51
Page 5
Only the use of the
correct fuel will ensure
safe, efficient, and
comfortable use of your
Zibro.
WHAT YOU NEED TO KNOW IN ADVANCE
ALWAYS MAKE SURE THAT THERE IS SUFFICIENT VENTILATION
This heater is equipped with an air quality control system . When there is insufficient ventilation in the room or when the heater is being used in a room which is too small, the heater will shut off automatically. For comfortable and safe heating ensure that there is sufficient ventilation. Note: To avoid unexpected shut off, we recommend to put a door or window ajar when the heater is operating.
For each Zibro model the minimum size of space is specified in which you can use the heater safely, without additional ventilation (refer to Section P). If a particular room is smaller than the specified space, always leave a window or door slightly ajar (± rooms and/or at altitudes above 1,500 metres. Do not use your Zibro in cellars or other underground areas.
THE RIGHT FUEL
Only use Class C1 paraffin fuel in accordance with BS2869: Part 2, or equivalent. Your Zibro heater has been designed for use with high-quality water-free pure paraffin oil, such as Zibro Extra or Zibro Kristal. Only fuels of this kind will ensure clean and proper burning. Lower quality fuel may result in:
E increased possibility of malfunctioning E incomplete burning E reduced heater lifetime E smoke and/or smells E deposits on the grid or mantle
Using the right fuel is therefore essential for safe, ef of your heater.
2.5 cm). We also recommend doing this in highly insulated or draught-free
ficient, and comfortable use
This transportation cap
is packed separately in
the box. Only this cap
ensures trouble-free
transportation of the
heater after use.
Store it well!
4
Always refer to your local Zibro dealer for the right fuel for your heater.
A
52
Page 6
MANUAL
654
321
6
543
2
1
E E E E E E
A INSTALLING THE HEATER
Carefully remove your Zibro from the box and check the contents. In addition to the heater you also need to have:
E a manual fuel pump E a transportation cap E these directions for use
Keep the box and the packaging materials (Fig. A) for storage and/or transportation.
Open the lid of the removable tank D and remove the piece of cardboard.
Fill the removable tank as indicated in Section B.
The floor should be firm and completely level. Reposition the heater, when it is not level. Do not try to correct the situation by placing books or other goods under the heater
B
.
Insert the plug K into the wall-socket (230 Volts - AC / 50 Hz) and set the correct time using the adjustment keys O (refer to Section C).
Your Zibro is now ready for use.
C
D
B FILLING FUEL
Do not fill the removable tank in the living room, but in a more suitable place (there can always be some spillage). Follow the procedure below:
Make sure that the heater is switched off.
Open the lid 4 and lift the removable tank 7 out of the heater (Fig. B). Note: Some drops may leak from the tank. Put down the removable tank (cap pointing upwards) and screw of
Take the manual fuel pump and insert the smooth, most rigid tube into the jerrycan. Make sure that it is in a higher position than the removable tank (Fig. D). Insert the ribbed hose into the opening of the removable tank.
Lock the switch button on top of the pump (turn clockwise).
f the fuel cap (fig. C).
Squeeze the pump a few times, until fuel starts flowing into the removable tank. As soon as this happens, there is no need to press any longer.
E
empty full
Check the removable tank fuel gauge G while filling the tank (Fig. E). Stop filling by loosening the switch button on top of the pump (turn anti-clock­wise), once the gauge indicates that the tank is full. Never overfill the tank, especially not when the fuel is very cold (fuel expands when it heats up).
4
53
Page 7
8
7
F: When the 4-digit stops
blinking, the setting has
been locked to the
indicated value.
Let the remaining fuel in the pump flow back into the jerrycan and carefully remove the pump. Carefully screw the fuel cap back on the tank. Clean off any spilled fuel.
Check whether the fuel cap is straight and tightened properly. Reinstall the removable tank in the heater (cap down). Close the lid.
C SETTING THE CLOCK
It is only possible to set the correct time, when the heater is connected to the mains and not burning. Use the adjustment keys O to set the time. First press either of the two keys to switch on the function (the 4-digit L will start blinking). Next, set the hours using the key (Nhour) and the minutes using the key (Mmin.). Press once to increase the value by one step. When you hold down the key value will continue going up, until you release the key again. After approximately 10 seconds the 4-digit will stop blinking and the setting will be locked. 5 minutes after switching off the heater, the information on the display will disappear and the heater will automatically switch into the stand-by position.
When the heater has been unplugged for more than 10 minutes (or after a
power failure), the time needs to be set again.
, the
G: The required
temperature on the left,
the measured
temperature on the
right.
D IGNITING THE HEATER
When used for the first time, a new heater may give out a smell for a short while. You should therefore provide extra ventilation.
M
Always ignite the heater with the button lighter. blinking, indicating that the ignition procedure has started. This will take a short while. Once the heater is burning, the information display L will show two numbers (Fig. G). The actual room temperature is indicated below ROOM, while the temperature setting is indicated below SET Prior to igniting the heater, always check for sufficient fuel in the removable tank.
Just press the button M to ignite the heater. The button will start
. The latter can be changed with the adjustment keys (refer to Section E).
. Never use matches or a cigarette
button M will remain lit (red). The
E SETTING THE REQUIRED TEMPERATURE
The temperature setting can only be adjusted, when the heater is burning. Use the adjustment keys O to adjust the temperature. First press either of the two keys to switch on the function (the °C mark and 4-digit L will start blinking). Next, adjust the temperature using the key (Mmin.) to set the temperature to a higher setting and the key (Nhour) to lower the temperature. Press once to increase the value one step. After approximately 10 seconds the °C mark and 4-digit will stop blinking and the setting will be locked (Fig. F). The available temperature settings range from 6°C minimum to 28°C maximum. When the heater has been unplugged for more than 10 minutes (or after a power failure), the temperature will reset to the factor
y setting of 20°C.
F USING THE TIMER
The timer allows you to switch on the heater automatically at a preset time. In order to switch on the timer, the correct time must have been set (refer to Section C) and the heater should be off. Follow the procedure below:
4
54
Page 8
21432
1
H: The TIMER indicator
light indicates that the
timer function has been
switched on.
Press the button M and then the TIMER key P immediately after that. The TIMER light and the information display L will start blinking.
Use the adjustment keys O to set the time at which the heater must ignite. Use the key (Nhour) to set the hours and the key (Mmin.) to set the minutes (interval of 5 minutes).
After approximately 10 seconds the information display will show CLOCK again and the TIMER indicator light will light up, indicating that the timer function has been activated (Fig. H).
The timer will ensure that the room will have been heated to approximately the required temperature at the set time.
When you want to switch of
you have to do is press the TIMER key (refer to Section G).
Press the button M once to clear the timer setting.
G SWITCHING OFF THE HEATER
There are two ways to switch off the heater.
Press the button M. The information display will show the CLOCK signal. Within approximately one minute the flame will have extinguished.
Press the TIMER key P, when you want to switch off the heater and ignite it again with the timer the next time. This not only switches of it also activates the timer function. Y adjustment keys O (refer to Section F).
H THE INFORMATION DISPLAY
The information display L not only serves as an indicator of the (set) time and temperature (Sections C, E, and F), it also indicates any malfunctioning of the heater. The code on the information display tells you what is the matter:
f the heater and ignite it again with the timer, all
f the heater, but
ou can change the required time with the
In case of any
malfunctioning the
information display will
tell you what is the
matter.
CODE INFORMATION WHAT TO DO
e - 0 Temperature within the heater too high. Cool-down and re-ignite. f - 0 Power interrupted. Re-ignite the heater. e - 1 Faulty thermostat. Contact your dealer. f - 1 Faulty burner thermistor. Contact your dealer. e - 2 Starting problems. Contact your dealer. e - 5 Tipping-over protection. Re-ignite the heater. e - 6 Poor burning. Contact your dealer. e - 7 Room temperature If necessary,
above 32°C. re-ignite the heater.
e - 8 Defective booster. Contact your dealer. e - 9 Air filter dirty; or Clean filter
Fuel pump dirty. Contact your dealer.
4
55
Page 9
The heater has been in operation continuously for a period of 69 hours hours and has turned itself off automatically. Switch the heater back on.
+
-- : --
-- : --
+
e - 1 1
Always contact your Zibro dealer for any malfunctioning not listed above.
AUTOMATIC DEACTIVATION
This heater is fitted with a safety system that ensures that it switches off automatically after 69 hours continuous operation. The following will then appear in the display: . If desired, you can switch the heater on again by pressing the button M (see Section D).
AUTOMATIC CLEANING MODE
When the heater has been burning continuously for two hours at its highest setting, the burner will automatically start an autoclean procedure. The display will show the autocleaning code cl:05 running back to cl:01. The procedure takes 5 minutes, during which the heater will burn at its lowest setting, while the bur autocleans. When the burner is clean again, the heater will automatically switch back to the highest setting again.
Out of fuel. Refill removable tank.
+
Too little ventilation. Ventilate better. Too little ventilation. Ventilate better.
ner
I: When the mark
appears, the childproof
lock has been activated.
J: When the SAVE function is activated, the heater will automatically switch on or off in order
to remain within a
specified temperature
range.
I CHILDPROOF LOCK
The childproof lock can be used to prevent children accidentally changing the heater settings. When the heater is burning and the childproof lock is on, the heater can only be switched off. Other functions are blocked then. If the heater has already been switched off, the childproof lock also prevents accidental ignition of the heater. down for more than 3 seconds. The KEY-LOCK indicator information display (Fig. I), indicating that the childproof lock has been activated. Switch off the childproof lock by pressing the key N and holding it down for more than 3 seconds once again.
Activate the childproof lock by pressing the appropriate key N and holding it
J THE CORRECT USE OF 'SAVE'
The 'SAVE' function allows you to limit the temperature. When this function is activated, the heater will automatically switch off, when the room temperature exceeds the set temperature by 3°C. Subsequently, when the room temperature has dropped again to the set temperature, the heater will automatically switch on again. Activate the 'SAVE' setting by pressing the appropriate Q key. will display on the information display (Fig. J). Switch off the function by pressing the SAVE key once again.
Without the 'SAVE' setting your heater will maintain the set temperature by approximation as well, by adjusting its heating capacity. 'SAVE' is an economy
setting, which you can use when, for instance, you are not present in the room or to keep it frost-free.
( )
will appear on the
4
56
Page 10
321
K: When the FUEL
indicator has appeard,
the information display
will show the number of
minutes of fuel left in
the tank.
L: A blinking
indicator light is a sign
that you need extra
ventilation.
K THE 'FUEL' INDICATOR
When the FUEL indicator appears, it means that there is only fuel left for 10 more minutes. The count-down of the remaining heating time can be seen in the information display L (Fig. K). Now you have two options:
E you remove the fuel tank and refill it outside the living room (section B) or E you push the button EXTENSION S. By pushing this button, the remaining
heating time will extend to 90 minutes. The heater will automatically switch back to its lowest position. In the display the number 90 will appear you will hear an alarm signal every two minutes, warning you to refill the removable tank. If you do not react, the heater will extinguish by itself. The heater will also sound a warning signal, when it switches off. The fuel indicator will blink, while four lines (--:--) are blinking in the information
display. You can stop this by pressing the button M once more. Once the heater has used up all its fuel and extinguished, it will take some time, after the refill, before the heater is completely ready for use again.
, which will decline to 10. At the arrival of 10,
L THE 'VENT' INDICATOR
When there is insufficient ventilation in the room, an intermittent buzzer will be heard (approximately once each 30 seconds) and the VENT indicator will be blinking. When this signal is given, ensure that the ventilation of the room is improved (e.g. by opening a door or window a little more), to avoid that the heater shuts off. When the ventilation of the room is improved, the VENT indicator and buzzer will be deactivated. When there is still insufficient ventilation, the heater shuts off automatically. When this occurs, e -1 1 is displayed and the indicator is blinking and VENT indicator ( (e.g. by opening a door or window a little more), the heater can be ignited by
M
pushing
again.
) is lit. After improving the ventilation of the room
Fuel filter
M
M MAINTENANCE
Switch off the heater and let it cool down, before you start any maintenance work. Also disconnect the plug from the mains. Your Zibro needs hardly any maintenance. It is, however, important that you clean the air filter 8 and the vent filter 9 with a vacuum cleaner and the grid 2 with a damp cloth, both on a weekly basis. Remove the air filter cap occasionally (Fig. M) and clean it with soapy water. Prior to reinstallation, make sure that the air filter cap has fully dried. Regularly inspect the fuel filter as well:
Remove the removable tank 7 from the heater and remove the fuel filter
(Fig. N). Some drops may leak from the filter; keep a cloth at hand.
N
Remove the dirt by tapping the fuel filter upside-down against a hard surface.
(Never clean it with water!)
Reinstall the fuel filter into the heater.
e recommend that you remove dust and stains in time with a damp cloth,
W because otherwise these may cause stains that are hard to remove.
Do not remove any heater components yourself. Always contact your Zibro dealer for repairs. When the power cord is damaged, it may only be replaced by an authorised fitter. Use a new cord of the type H05 VV-F.
4
57
Page 11
N STORAGE (END OF THE HEATING SEASON)
432
1
At the end of the heating season, you must store the heater in a dust-free place, if possible in its original packaging. Unused fuel cannot be used in the next heating season. We therefore recommend that you burn up all fuel. If there is still some fuel left, do not throw it away, but dispose of it in accordance with the local regulations for the disposal of domestic chemical waste. Always start the new heating season with fresh fuel. When you start re-using the heater follow the instructions again (starting from section A and as specified).
O TRANSPORTATION
O
Take the following measures to avoid fuel leakage during the transportation of the heater:
Let the heater cool down.
Remove the removable tank G from the heater and remove the fuel filter
(refer to Section M, Fig. N). Some drops may leak from the filter; keep a cloth
at hand. Store the fuel filter and the removable tank outside the heater
.
transportation cap
Place the transportation cap into the position of the fuel filter (Fig. O).
Press it tight.
Always move the heater in an upright position.
P SPECIFICATIONS
Ignition electrical Dimensions (mm) width 550 Fuel paraffin (including base plate) depth 328 Capacity (kW) max. Capacity (kW) min. Suitable space (m Fuel consumption (l/hr) Fuel consumption (g/hr) Burning time per tank (hr) Capacity removable tank (litres) 7.6 continuous Weight (kg) Monitoring of the quality of ventilation (air renewal):
Direct measurement of the CO
* At maximum setting ** Specified values are indicative
3)**
*
*
*
3.90
1.05
Accessories manual fuel pump
65-170
0.109-0.406 87-325
level (NDIR CO2-sensor E-Guard T).
2
Mains 230V
18.2
Electrical consumption
12.0
Fuse rating 250V, 5A
height 445
transportation cap
-- AC/50 Hz
igniter 320 W
29W
4
58
Page 12
Q WARRANTY PROVISIONS
7654321
Your heater comes with a 48-month warranty starting on the date of purchase. Within this period all defects in material or workmanship will be repaired without any charge. The following provisions shall apply regarding this warranty:
We expressly dismiss all other claims for damages, including consequential damages. Any repairs or replacements of components within the term of warranty will not result in an extension of the term of warranty. The warranty shall no longer apply, when the heater has been modified, non-original parts have been used, or when it is repaired by third parties. The warranty shall not apply to parts that are subject to normal wear, such as the burner mat and the manual fuel pump. The warranty shall only apply, when you present the original, dated proof of purchase, provided no changes have been made to it. The warranty shall not apply to damages caused by actions not in compliance with the Directions for Use, neglect, and the use of an incorrect type of fuel, or fuel past its use-by date. The use of incorrect fuel can even be dangerous*. Transportation costs and the risks involved during the transportation of the heater or heater components shall always be for the account of the purchaser.
In order to avoid unnecessary costs, we recommend that you always read the ’Directions for Use’ carefully first. In case they offer no solution, please take the heater to your dealer for repair.
* Highly inflammable substances may induce uncontrollable burning, causing flames to break out. Should this happen, never try to move the heater, but always switch off the heater immediately. In case of emergency you may use a fire extinguisher, but only a type B extinguisher: a carbon dioxide or powder extinguisher.
11 TIPS FOR SAFE USE
1 Children should be supervised to ensure that they do not play with the
appliance.
2 Do not move the heater when it is burning or still hot. Do not refill nor
service the heater when it is burning or still hot.
3 Position the front of the heater at a distance of minimum 1.5 metres
from walls, curtains, and furniture.
4 Do not use the heater in dusty rooms. You will not have optimum
burning in such rooms. Do not use the heater in the immediate surrounding of a bath, a shower or a swimmingpool.
5 Switch off the heater, before you leave or go sleeping. Unplug the
heater as well, when you go away for a longer period of time (e.g. holidays).
6 Store and move fuel only in suitable tanks and jerrycans. 7 Make sure that the fuel is not exposed to heat or extreme temperature
changes. Always store the fuel in a cool, dry and dark place (sunlight will af
fect the quality).
8 Never use the heater in places where harmful gasses or fumes may be
present (e.g. exhaust gasses or paint fumes).
9 Beware that the grid of the heater becomes hot. If the appliance is
covered there is a risk of fire.
10 Always make sure that there is sufficient ventilation. 11 This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of expe rience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
-
Defective electrical devices and batteries must be kept separate from household waste. Ensure that there is effective recycling where possible. Ask you local council or dealer for expert advice on recycling.
4
59
Page 13
G
E
A
B
C
L
F
D
J
T
I
H
K
E
QP
R
O
SN
M
Page 14
DISTRIBUTED IN EUROPE BY PVG INTERNATIONAL b.v.
i ÖSTERREICH
K.B. Deutschland GmbH Bahnhofstrasse 150a D – 48712 GESCHERE tel:
+49 (0) 2542 – 917560 fax: +49 (0) 2542 – 917568 email: info@kb-deutschland.de
e BELGIË
PVG Belgium NV/SA Industrielaan 55 2900 SCHOTEN tel:
+32 3 326 39 39 fax: +32 3 326 26 39 email: pvgbelgium@zibro.com
q SCHWEIZ
PVG Schweiz AG Salinenstrasse 63 4133 PRATTELN tel:
+41 61 337 26 51 fax: +41 61 337 26 78 email: pvgint@zibro.com
2 DEUTSCHLAND
K.B. Deutschland GmbH Bahnhofstrasse 150a D – 48712 GESCHERE tel:
+49 (0) 2542 – 917560 fax: +49 (0) 2542 – 917568 email: info@kb-deutschland.de
4 UNITED KINGDOM
Scott Brothers Ltd. The Old Barn, Holly House Estate Cranage, Middlewich, CW10 9L
T UK tel.: +44 1606 837787 fax: +44 1606 837757 email: sales@scottmail.co.uk
> ITALIA
PVG Italy SRL Via Niccolò Copernico 5 50051 CASTELFIORENTINO (FI) tel:
+39 571 628 500 fax: +39 571 628 504 email: pvgitaly@zibro.it
u NORGE
Appliance A/S Gefionsvej 7 DK-3400 HILLERØD tel:
+45 70 205 701 fax: +45 70 208 701 email: appliance@appliance-group.com
1 NEDERLAND
PVG International B.V. P.O. Box 96 5340 AB OSS tel: +31 412 694 694 fax: +31 412 622 893 email: pvgnl@zibro.com
New 7/09
6 DANMARK
Appliance A/S Gefionsvej 7 DK-3400 HILLERØD tel: +45 70 205 701 fax: +45 70 208 701 email: appliance@appliance-group.com
5 ESPAÑA
PVG España S.A. Pol. Ind. San José de Valderas II Comunidad ”La Alameda” C/ Aurora Boreal, 19 28918 LEGANÉS (Madrid) tel: +34 91 611 31 13 fax: +34 91 612 73 04 email: pvgspain@zibro.com
3 FRANCE
PVG France SARL 4, Rue Jean Sibélius
. 185
B.P 76410 SOTTEVILLE SOUS LE VAL tel: +33 2 32 96 07 47 fax: +33 0 820 34 64 84 email: pvgfrance@zibro.com
FFIINN
FFIINN
SUOMI
Appliance A/S Gefionsvej 7 DK-3400 HILLERØD tel: +45 70 205 701 fax: +45 70 208 701 email: appliance@appliance-group.com
9 PORTUGAL
Gardena, Lda Recta da Granja do Marquês ALGUEIRÃO 2725-596 MEM MARTINS tel: + 35 21 92 28 530 fax:
+ 35 21 92 28 536 email: pvgint@zibro.com
: POLSKA
PVG Polska Sp. z. o. o.
ścielna 110
ul. Ko 26-800 Białobrzegi tel:
+48 48 613 00 70 fax: +48 48 613 00 70 email: pvgpoland@zibro.com
= SVERIGE
Appliance A/S Gefionsvej 7 DK-3400 HILLERØD tel: +45 70 205 701 fax:
+45 70 208 701 email: appliance@appliance-group.com
y SLOVENIJA
Monteko d.o.o. Neubergerjeva 4 1000 Ljubljana tel: +386 (0)1 437 1273 fax: +386 (0)1 437 1273 email: info@zibro.si
TTRR
TTRR
TURKEY
PVG Is›tma Klima So¤utma Ltd.fiti.
Tepekule is merkezi Anadolu Cad. No: 40 K:3 D:306 35010 BA
YRAKLI/IZMIR tel: + 90 232 461 51 01 fax: + 90 232 461 51 85 email: pvgturkey@zibro.com
PVG Traffic avg©090702 man_SRE179E
Loading...