Zephyr DVSE30ASSX, DVSE36ASSX PRODUCT SPECIFICATIONS

DESIGNER
VISTA
WALL
16-7/16”
11-1/4”
8”
9-1/8”
29-15/16” or 35-15/16”
ZEPHYRONLINE.COM
Standard min ducted. 25-1/2” min. recirc. 29-1/2” max. 38-1/2”
Z1C-00VS min. ducted 42” min. recirc. 46” max. 78-1/2”
17-5/8”
13-9/16”
BACK
10-1/16”
18-7/8”
SIDE
2-1/8”
18-7/8”
TOP
4-1/4” ( 8”)
3-7/16” ( 6”)
Remote Blower
Internal Blower
DESIGNER
VISTA
WALL
MODEL Stainless Steel
Size
BLOWER PERFORMANCE Internal Blower (CBI-290C)* Internal Blower (CBI-600A)* In-Line Blower (PBN-1000A)* External Blower (CBE-1000)*
FEATURES Controls Speed Levels
Auto Delay-O
CleanAir Function** Lighting Tri-Level Lighting Filters Perimeter Aspiration System Recirculating Extension Duct Cover Option ADA Compliant
DUCT SPECIFICATIONS Vertical Single Internal Blower Vertical In-Line/External Blower
DVS-E30ASSX 30”
200-290 CFM, 1.4-3 sones 240-600 CFM, 1.8-6 sones 500-1,000 CFM, sones NA 500-1,000 CFM, sones NA
Invisible Touch 3 Yes Yes LED, 5W x2 Yes Aluminum Mesh x2 Yes Yes Yes, Up to 12’ Ceiling Yes, with remote option
6” Round 10” to 8” Round***
ZEPHYRONLINE.COM
DVS-E36ASSX 36”
200-290 CFM, 1.4-3 sones 240-600 CFM, 1.8-6 sones 500-1,000 CFM, sones NA 500-1,000 CFM, sones NA
Invisible Touch 3 Yes Yes LED, 5W x2 Yes Aluminum Mesh x3 Yes Yes Yes, Up to 12’ Ceiling Yes, with remote option
6” Round 10” to 8” Round***
AC POWER Hood w/ CBI-290C Hood w/ CBI-600A Hood w/ PBN-1000A Hood w/ CBE-1000
120V, 60Hz, Max. 1A 120V, 60Hz, Max. 3A 120V, 60Hz, Max. 5.4A 120V, 60Hz, Max. 6.6A
120V, 60Hz, Max. 1A 120V, 60Hz, Max. 3A 120V, 60Hz, Max. 5.4A 120V, 60Hz, Max. 6.6A
OPTIONAL ACCESSORIES Recirculating Kit Remote Control Duct Cover - Stainless Steel
Stainless Steel Telescopic Backsplash Make-Up Air Kit
ZRC-00VS 14000010 Z1C-00VS AK1710 MUA006A (600 CFM) MUA008A (1,000 CFM)
MOUNTING HEIGHT RANGE****
WARRANTY
CEILING HEIGHT
STANDARD DUCT COVER
EXTENSION DUCT COVER
*Blower sold separately. **CleanAir turns your hood on once every four hours for 10 minutes on speed one. ***10” round duct connects to external and in-line blower. Must transition from 10” to 8” before duct passes through ceiling. A 10” to 8” adapter is included with external and in-line blowers. ****Mounting height refers to distance between top of a 36” tall cooking surface and bottom of hood.
Ducted Mounting Height*
Recirc Mounting Height*
Ducted Mounting Height*
Recirc Mounting Height*
24” - 36”
2 year parts, 1 year labor
8’
24” - 34.5”
24” - 30.5”
NA
NA
ZRC-00VS 14000010 Z1C-00VS AK1716 MUA006A (600 CFM) MUA008A (1,000 CFM)
24” - 36”
2 year parts, 1 year labor
8.5’
27.5” - 36”
27.5” - 36”
24” - 24”
NA
9’
33.5” - 36”
33.5” - 36”
24” - 30”
24” - 26”
9.5 ’
NA
NA
24” - 36”
24” - 32”
10’
NA
NA
24” - 36”
24” - 36”
10.5’
NA
NA
24” - 36”
24” - 36”
11’
NA
NA
24” - 36”
24” - 36”
12’
NA
NA
29.5” - 36”
29.5” - 36”
DID YOU KNOW?
The Perimeter Aspiration System moves airflow away from the central area of the hood and evenly distributes it through narrow openings around the perimeter of the hood. This ventilation method increases air velocity and improves the capture of cooking contaminants.
Specifications subject to change, check zephyronline.com for up-to-date information. Zephyr Ventilation | 2277 Harbor Bay Parkway, Alameda, CA 94502 | 888.880.VENT
AUG21.0101