Zephyr AK2100, AK2136 Use, Care And Installation Manual

USE, CARE AND INSTALLATION GUIDE
Read all instructions before installing and operating this appliance
IMPORTANT SAFETY NO TICE
Installation
The installation instruction in this manual is intended for qualified installers, service technicians or persons with similar qualified background. DO NOT attempt to install this appliance yourself. Injury could result from installing the unit due to lack of appropriate electrical and technical background.
All electrical wiring should be properly installed, insulated, and grounded. Overly accumulated grease on old duct work should be cleaned out or duct work should be replaced if necessary to avoid the possibility of grease fire. Check all sections and joints on duct work to insure proper connection and all joints should be properly taped.
Operations
Read all instructions in this manual before operating the appliance. Save these instructions for future reference.
ALWAYS leave safety grills attached in place at all times. Operating blowers could catch on to hair, fingers, and loose clothing.
Keep unit and residue containers clean from grease accumulation from time to time. NEVER dispose foreign substances into the blowers. Do not dispose cigarette ashes or ignitable substances into the blowers.
Cleaning
Use with extreme caution while performing the Self Cleaning Function and safety grills are removed. Beware of fingers, hair, loose clothing from getting in the blowers and NEVER leave children unattended.
NEVER disassemble parts to clean without proper instructions. Disassembly are recommended to be performed by qualified personnel only. We are not responsible for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance. Call our Service Center for removal instructions.
WARNING
MODEL: TYPHOON AK2100, AK2136
CONTROLS
2
Controls Overview
delay off
5 10 15
lowminutes high on/off lamp
(A) turns blowers on/ off
(B) adjust to higher speed level (1 to 6)
(D) turns lights on/off and dim (night light)
(C) adjust to lower speed level (6 to 1)
(E) shuts off hood in 5, 10 or 15 minutes
(F) Indicator: indicates 5, 10, or 15 minutes delay when lit
(G) Indicator: indicates level of blower speed from 1 to 6
Level 1(low) -Indicator 1 flashing Level 2 - Indicator 1 lit Level 3 - Indicator 2 flashing Level 4 - Indicator 2 lit Level 5 - Indicator 3 flashing Level 6 (high) - Indicator 3 lit
1 2 3
Zephyr Model AK2100 & AK2136 Touch Control Module
Blower Controls
Turn on the blowers by pressing “on/off” once.
Adjust level of speed (1 to 6) by pressing “high” or “low”.
Speed Indicator The speed indicator will show the speed the blowers are operating at as follow:
Level 1(low) -Indicator 1 flashing Level 2 - Indicator 1 lit Level 3 - Indicator 2 flashing Level 4 - Indicator 2 lit Level 5 - Indicator 3 flashing Level 6 (high) - Indicator 3 lit
Note: The control is equipped with a speed setting memory module. When turning on the blowers, the speed level will start at the speed setting last memorized.
Turn off the blowers by pressing “on/off” again.
Lights Controls
Turn on halogen lamps by pressing “lamp”.
Press 2nd time will dim to night light.
Press again to turn lamps off.
Note: Use type HR16 (E27) halogen bulbs only. Max 35W
CONTROLS
press:
turns blowers on
on/ off
highlow
adjust speed from low to high (1 to 6)
high
low
1 2 3
turns blowers off
on/ off
indicator:
press:
press:
turns lights on
lamp
press:
turn lights down (night light)
lamp
press again:
turns lights off
lamp
press again:
3
Timed Delay Off
Press “delay off” once to turn all range hood operation off in 5 minutes.
Indicator “5” will be lit
Press “delay off” twice to turn all range hood operation off in 10 minutes.
Indicator “5” & “10” will be lit
Press “delay off” the third time to turn all range hood operation off in 15 minutes.
Indicator “5”, “10” & “15” will be lit
CONTROLS
press once:
turns off in 5 minutes
delay off
Indicator
indicator “5” will be lit
5 10 15
delay off
press twice:
turns off in 10 minutes
delay off
Indicator
indicator “5” & “10” will be lit
5 10 15
delay off
press again:
turns off in 15 minutes
delay off
Indicator
indicator “5”, “10” & “15” will be lit
5 10 15
delay off
4
INSTALLATION
MIN. 18” MAX 30”
net width
CLEARANCES
Minimum clearance above range should be no less than 18“ from the range surface to the range hood’s base. Maximum height are recommended not to exceed 30” for maximum efficiency.
Net width on all models are call out width less 1/4”.
Note: Refer Manufacturers’ height clearance requirements on all high btu and professional ranges.
5
DUCT REQUIREMENT
Minimum duct size should be no less than 7”. Smaller duct size, long duct run and turns will reduce hood performance and efficiency.
Use single wall ridgit type galvanized pipes only, do not use flexible type ducts.
Generally, use minimum duct size recommended (7”). Reduce the number of turns and bends. If long duct run (beyond 20’ vertical and 35’ horizontal) is required, increase
Duct Type Round Duct Size 7” Minimum Duct opening Vertical
size of duct to 8 or 9”.
If a reducer is required, use a long reducer instead of a short pancake reducer. Install reducers as far away from duct opening as possible.
If turns are required: Install first elbow as far away from opening as
possible. Between elbows, install as far as possible. Use two 45 elbow (installed as far apart as
possible), instead of one 90 elbow. Increase duct size.
Call Out Size Net Width
30” 29-3/4” 36” 35-3/4”
INSTALLATION
6
DUCT OPENING
Front
Rear
Front
Rear
Wall
7”
8”
(min. cutout)
C/L
C/L
ELECTRICAL & DRILL LOCATIONS
Front
Rear
7”
C/L
Electrical K/O (3/4”)
1-3/8”
3-3/4”
1-13/16”
10-5/16”
13-7/8”
C/L
9”
30” & 36” models (AK2100, AK2136)
30” models (AK2100)
Front
Rear
7”
C/L
Electrical K/O (3/4”)
2”
13-1/8”
1-13/16”
10-5/16”
16-7/8”
C/L
36” models (AK2136)
30”
36”
9-1/2”
Wall
Wall
Wal l