Motorola Solutions reserves the right to make changes to any product to improve reliability, function, or design.
Motorola Solutions does not assume any product liability arising out of, or in connection with, the application or use of any
product, circuit, or application described herein.
No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent, covering or
relating to any combination, system, apparatus, machine, material, method, or process in which Motorola Solutions products
might be used. An implied license exists only for equipment, circuits, and subsystems contained in Motorola Solutions products.
Service Information
If you have a problem using the equipment, contact your facility’s Technical or Systems Support. If there is a problem with the
equipment, they will contact the Motorola Solutions Support at: http://supportcentral.motorola.com.
Country Selection............................................................................................................................... 31
Operation in the US............................................................................................................................ 31
AP-7161 Access Point Installation Guide5
Radio Frequency Interference Requirements - FCC.......................................................................... 31
Radio Transmitters (Part 15).............................................................................................................. 32
Radio Frequency Interference Requirements - Canada..................................................................... 32
Radio Transmitters............................................................................................................................. 32
CE Marking and European Economic Area (EEA)............................................................................. 32
Statement of Compliance................................................................................................................... 32
Japan (VCCI) - Voluntary Control Council for Interference................................................................ 32
Korea Warning Statement for Class B............................................................................................... 33
Other Countries.................................................................................................................................. 33
Waste Electrical and Electronic WEEE.............................................................................................. 35
Motorola’s Enterprise Mobility Support Center................................................................................... 36
AP-7161 Series ROHS Compliance................................................................................................... 37
6AP-7161 Access Point Installation Guide
AP-7161 Access Point Installation Guide7
Introduction
The AP-7161 is a wireless broadband data system that uses mesh networking technology to support broadband data coverage.
The system offers both 2.4 GHz 802.11b/g/n and 5.x GHz 802.11n Wi-Fi client access with 2.4 GHz 802.11 b/g/n and 5.x GHz
802.11a/n meshing. The dual-band system supports industry standard client devices and features easily deployed fixed
infrastructure nodes.
The AP-7161 is also designed to extend the network with outdoor deployments. Deployments can be managed using the
Motorola Solutions WiNG 5 architecture. The WiNG 5 architecture is a solution designed for 802.11n networking. It leverages
the best aspects of independent and dependent architectures to create a smart network that meets the connectivity, quality and
security needs of each user and their applications, based on the availability of network resources, including wired networks.
WiNG 5 is a Third Generation WLAN solution – taking the best of both the first generation Autonomous access point WLAN and
the second generation Centralized Controller Based WLAN.
The control plane is now distributed between the access points and the controllers. The network administrator has the flexibility
of directing the data plane either being forwarded directly from the access points, or via the controllers. By distributing
intelligence and control between the wireless controllers and APs, the WiNG 5 network can route directly via the best path, as
determined by factors including the user, the location, the application and the available wireless and wired resources.
Once adopted by a Motorola Solutions RFS4000, RFS6000 or RFS7000 series controller, the AP-7161 is managed as an
Adaptive AP running the WiNG 5 network management protocol. Motorola Solutions WiNG 5 Networks extend the differentiation
that Adaptive APs offered to the next level by having the services and security now available at every point in the network. The
traffic flow is optimized to prevent wired congestion as well as wireless congestion. Traffic flows dynamically, based on user and
application, and finds alternate routes to work around any possible network choke points. Mixed-media application optimization
is the hallmark of WiNG 5 networks.
For the latest version of this guide go to:http://support.symbol.com/support/product/manuals.do
Document Conventions
The following graphical alerts are used in this document to indicate notable situations.AP-7161
.
NOTETips, hints, or special requirements that you should take note of.
CAUTIONCare is required. Disregarding a caution can result in data loss or equipment
malfunction.
WARNING! Indicates a condition or procedure that could result in personal injury or
equipment damage.
8AP-7161 Access Point Installation Guide
Package Contents
Carefully remove all protective material from around the AP-7161 and save the shipping container for later storage and shipping.
Verify that you received the equipment listed below:
• AP-7161 access point
• Weatherproof RJ45 plug kit
• AP-7161 Access Point Installation Guide
Inspect the equipment for damage. If you are missing any equipment or if you find any damaged equipment, contact the
Motorola Solutions Support immediately.
AP-7161 Access Point Installation Guide9
Hardware Installation
The AP-7161 access point has the following port designations:
• GE1/POE - LAN Port
• GE2 - WAN Port
• Console Port
An AP-7161 must be installed by trained professionals familiar with RF planning and regulatory limits defined by the regulatory
bodies of the country where the devices are being deployed. All common precautions for grounding and ESD (Electrostatic
Discharge) protection should be observed during deployment and installation. AP-7161 devices must be installed such that no
harmful interference results from device operation.
CAUTIONAll device wiring must comply with the National Electric Code (NEC) or
regulations and procedures defined by the regulatory bodies of the country or
region where the devices are being deployed. All local building and structure
codes must be observed.
WARNING! Strictly observe the following Safety Warnings and Precautions when installing
an AP-7161 access point.
Precautions
Before installing an AP-7161 model access point verify the following:
• Become familiar with all grounding requirements (see Installing an AP-7161 on page 14)
• The grounding cable for an AP-7161 must be a #10 gauge wire cross section. The cable can be attached to the unit using
one of the three recommended methods:
• Loosen the grounding screw, insert the grounding cable into the hole below it and tighten the screw.
• Loosen the grounding screw, wind the grounding cable around and tighten the screw.
• Attach a ring lug to the grounding cable and secure it to the unit using the grounding screw.
• Verify that the deployment environment has a continuous temperature range compatible with the operating temperature
range of the device.
Warnings
• Read all installation instructions and site survey reports, and verify correct equipment installation before connecting the
access point to its power source.
• Remove jewelry and watches before installing this equipment.
• Verify that the unit is grounded before connecting it to the power source.
• Verify that any device connected to this unit is properly wired and grounded.
• Connect all power cords to a properly wired and grounded electrical circuit. Verify that the electrical circuits have appropriate
overload protection.
• Attach only approved power cords to the device.
• Verify that the power connector and socket are accessible at all times during the operation of the equipment.
10AP-7161 Access Point Installation Guide
• Do not hold any component containing a radio such that it is very close to or touching any exposed parts of the body,
especially the face or eyes, while transmitting.
• Do not work with power circuits in dimly lit spaces.
• Do not install this equipment or work with its power circuits during thunderstorms or other weather conditions that could
cause a power surge.
• Verify there is adequate ventilation around the device, and that ambient temperatures meet equipment operation
specifications.
• Avoid contact with overhead power lines.
• Take precautions to avoid injury from falling tools and equipment. Crews should wear hard hats in and around the installation
work site.
• Be aware of vehicular traffic in and around the installation work site.
• Do not operate a portable transmitter near unshielded blasting caps or in an environment where explosives are present
unless the transmitter is especially certified for such use.
Site Preparation
• Consult your site survey and network analysis reports to determine specific equipment placement, power drops, and so on.
• Assign installation responsibility to the appropriate personnel.
• Identify and document where all installed components are located.
• Identify and prepare Ethernet and console port connections.
• Verify that cable lengths are within the maximum allowable distances for optimal signal transmission.
Grounding Requirements
To avoid damage to the equipment, become familiar with Motorola Solutions Policy R56 before installing AP-7161 units. Refer
to Standards and Guidelines For Communication Sites, Version B. Both the hardcopy manual (Part Number 68P81089E50-B)
and the CD version (Part Number 9880384V83) can be ordered from Motorola Solutions.
Section 7.6.4 Broadband - Wireless Access Point Network from the Standards and Guidelines For Communication
Sites applies directly to AP-7161 deployments: SPD (Surge Protection Device) considerations for broadband shall include the
use of SPDs to protect pole-mounted access points and ground-based cabinet architecture. It is important to install proper SPD
applications on both ends of Ethernet, Power-Over Ethernet (POE), Giga-Ethernet (GigE) and AC cable runs. SPDs shall be
located within the node or cabinet, or as close to the entrance as possible, and properly installed into load centers, control
panels and utility power cabinets. While RF protection is a consideration, it shall only be required when antennas are connected
to the node with coaxial cables greater than 610 mm (2 ft.) in length.
Lightning protection should be used on all shielded CAT-5E Ethernet connections.
An outdoor rated Lightning Protection Unit (LPU) kit such as the Motorola Solutions PTP WB2978AA or the HyperLink
AL-CAT6HPJW Lightning Protector should be used.
NOTELightning damage is not covered under the conditions of a standard Motorola Solutions product
warranty. When installed correctly, LPUs provide the best protection from the harmful effects of
lightning. Observe all regional and national codes that apply for lightning protection.
AP-7161 Access Point Installation Guide11
AP-7161 Grounding Connection
The grounding cable for an AP-7161 must be a #10 gauge wire cross section.The grounding screw is located to the right of the
GE1/POE port above the ground symbol.
The cable can be attached to the unit using one of the three recommended methods:
• Loosen the grounding screw, insert the grounding cable into the hole below it and tighten the screw.
• Loosen the grounding screw, wind the grounding cable around and tighten the screw.
• Attach a ring lug to the grounding cable and secure it to the unit by tightening the grounding screw.
When connecting the grounding cable to the unit, use an 8mm Socket and driver to tighten the grounding screw to between 21.9
and 29.2 inch pounds (lbf-in).
Ethernet and Lightning Protection
When installing an AP-7161, lightning protection should be used on all Shielded CAT-5E Ethernet connections. An outdoor rated
Lightning Protection Unit (LPU) kit such as the Motorola Solutions PTP WB2907AA or the HyperLink AL-CAT6HPJW Lightning
Protector should be used. For more information on Motorola Solutions PTP Lightning Protection Unit, refer to the PTP-LPU
Technical Specifications.
Access Point Placement
Observe the following recommended guidelines to help ensure a successful network deployment:
• Mount the device with the black gore vent down.
• Mounting height for network devices should not exceed 30 to 35 feet. Mounting height should vary to accommodate the
topography of the deployment area, foliage, and other obstructions.
• Devices can be deployed using any of the recommended outdoor Deployment Procedures.
• Line of sight (LoS) guidelines should be given special consideration whenever devices will not be installed in a straight line,
such as deploying devices on alternating sides of a roadway.
12AP-7161 Access Point Installation Guide
Antenna Options
Motorola Solutions supports two antenna suites for AP-7161 access points, one suite supporting the 2.4 GHz band and another
suite supporting the 5 GHz band. Select a model best suited to the intended operational environment of your access point. The
AP-7161 model access point can be purchased in a three radio configuration. If a three radio unit is purchased, the access point
ships with two dual-band radios that should be connected to ports R3-A and R3-B. This is in addition to the other six antennas
available to the access point’s other two radios. The single antenna supporting the third radio supports sensor mode only and
can not function as a WLAN radio.
WARNING! Antenna ports where no antenna is mounted must be properly terminated using
an approved IP 67 terminator.
AP-7161 Access Point Installation Guide13
The AP-7161 antenna suite includes the following models:
Antenna DescriptionBandGain
2,4 GHz, fixed DP, Omni, 80 dBi, Type N-M2.4819.5/495ML-2499-FHPAG8-01
5.4 GHz, fixed DP, Omni, 10 dBi, Type N-M4.9-5.8.1019.5/495ML-5299-FHPAG10-01
Dual Band WIPS antenna2.4, 5.2-5.84.5-7.511/280ML-2452-HPAG5A8-01-01
2.4 GHz, downtilt 8 dBi, Type N-M2.4821/533RAN4054A
Height
(in/mm)
P/N
14AP-7161 Access Point Installation Guide
Installing an AP-7161
The following guidelines and procedures should be observed when installing an AP-7161:
Required Tools
The following is a list of the minimal tool set required to install an AP-7161:
• 8 mm socket and driver
• Torque wrench or ratchet with 10mm, 1/2 inch and 3/4 inch sockets.
• Adjustable wrench
Mounting Bracket Options
The mounting bracket kit and extension mounting hardware for the AP-7161 support several options for installation.
The AP-7161 mounting bracket kit contains:
DescriptionPart NumberQuantity
Mounting bracket section 1SKJC120210-0011
Mounting bracket section 2SKJC120210-0021
Mounting bracket section 3SKJC120210-0031
Serrated hex flanged screw, M6 x1.0 x 12SKJC120210-0048
Hex nut, 1/2inch - 13 threadSKJC120210-0064
Hex head bolt, 1/2 inch - 13 thread x 3/4 inchSKJC120210-0072
The three individual sections for the AP-7161 mounting bracket kit (P/N SKJC120210-001, -002 and -003) can be adjusted to