TC7X Ethernet Cup Conversion
Installation Instructions
NOTE: This rework activity must be performed by
the qualified technician or engineer in an ESD safe
workstation. The technician or engineer must wear
a grounded ESD strap.
1. Remove the AC power from the cradle.
2. Remove the screw securing the ethernet cup to the
cradle using a Phillips screwdriver.
4. Disconnect the ethernet cup cables from the
connectors.
3. Slide the ethernet cup forward and lift.
5. Connect the new ethernet cup cables to the
connectors.
ZEBRA and the stylized Zebra head are trademarks of Zebra Technologies Corp., registered in many jurisdictions
worldwide. All other trademarks are the property of their respective owners. © 2022 Zebra Technologies Corp. and/or
its affiliates. All rights reserved. | zebra.com
MN-004468-01EN Rev. A 3/2022

6. Align the new ethernet cup with the cradle and slide the
ethernet cup back.
7. Using a Phillips screwdriver, secure the new ethernet
cup to cradle with screw.
2