Zebra P460 Handheld Scanner PL460 Phaser Cradle Quick Reference Guide

PL 360/460 Cradle
PL 360/460 Cradle
© 2001 SYMBOL TECHNOLOGIES, INC. All rights reserved. Symbol reserves the right to make changes to any product to improve reliabilit y,
function, or design. Symbol does not assume any product liability arising out of, or in connection with, the
application or use of any product, circuit, or application described herein. No license is granted, either expressly or by implication, estoppel, or otherwise under
Symbol and the Symbol logo are reg istered trademarks of Symbol Technologies, Inc. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged.
Symbol Technologies, Inc. One Symbol Plaza Holtsville, N.Y. 11742-1300
http://www.symbol.com
Patents
This product is covered by one or more of the following U.S. and foreign Patents: U.S. Patent No. 4,460,120; 4,496,831; 4,593,186; 4,603,262; 4,607,156; 4,652,750; 4,673,805; 4,736,095; 4,758,717; 4,816,660; 4,845,350; 4,896,026; 4,897,532; 4,923,281; 4,933,538; 4,992,717; 5,015,833; 5,017,765; 5,021,641; 5,029,183; 5,047,617; 5,103,461; 5,113,445; 5,130,520; 5,140,144; 5,142,550; 5,149,950; 5,157,687; 5,168,148; 5,168,149; 5,180,904; 5,216,232; 5,229,591; 5,230,088; 5,235,167; 5,243,655; 5,247,162; 5,250,791; 5,250,792; 5,260,553; 5,262,627; 5,262,628; 5,266,787; 5,278,398; 5,280,162; 5,280,163; 5,280,164; 5,280,498; 5,304,786; 5,304,788; 5,306,900; 5,321,246; 5,324,924; 5,337,361; 5,367,151; 5,373,148; 5,378,882; 5,396,053; 5,396,055; 5,399,846; 5,408,081; 5,410,139; 5,410,140; 5,412,198; 5,418,812; 5,420,411; 5,436,440; 5,444,231; 5,449,891; 5,449,893; 5,468,949; 5,471,042; 5,478,998; 5,479,000; 5,479,002; 5,479,441; 5,504,322; 5,519,577; 5,528,621; 5,532,469; 5,543,610; 5,545,889; 5,552,592; 5,557,093; 5,578,810; 5,581,070; 5,589,679; 5,589,680; 5,608,202; 5,612,531; 5,619,028; 5,627,359; 5,637,852; 5,664,229; 5,668,803; 5,675,139; 5,693,929; 5,698,835; 5,705,800; 5,714,746; 5,723,851; 5,734,152; 5,734,153; 5,742,043; 5,745,794; 5,754,587; 5,762,516; 5,763,863; 5,767,500; 5,789,728; 5,789,731; 5,808,287; 5,811,785; 5,811,787; 5,815,811; 5,821,519; 5,821,520; 5,823,812; 5,828,050; 5,850,078; 5,861,615; 5,874,720; 5,875,415; 5,900,617; 5,902,989; 5,907,146; 5,912,450; 5,914,478; 5,917,173; 5,920,059; 5,923,025; 5,929,420; 5,945,658; 5,945,659; 5,946,194; 5,959,285; 6,002,918; 6,021,947; 6,047,892; 6,050,491; 6,053,413; 6,056,200; 6,065,678; 6,067,297; 6,068,190; 6,082,621; 6,084,528; 6,088,482; 6,092,725; 6,101,483; 6,102,293; 6,104,620; 6,114,712; 6,115,678; 6,119,944; 6,123,265; 6,131,814; 6,138,180; 6,142,379; D305,885; D341,584; D344,501; D359,483; D362,453; D363,700; D363,918; D370,478; D383,124; D391,250; D405,077; D406,581; D414,171; D414,172, D418,500; D419,548; D423,468; D424,035 D431,158; D430,159; D431,562. Invention No. 55,358; 62,539; 69,060; 69,187 (Taiwan); No. 1,601,796; 1,907,875; 1,955,269 (Japan). European Patent 367,299; 414,281; 367,300; 367,298; UK 2,072,832; France 81/03938; Italy 1,138,713. rev. 09/00
Quick Reference
The PhaserLink PL 360/460 Cradle acts as a stand, host communication interface, and a charger for the Phaser Scanner. It can sit on a desktop or be wall-mounted - whichever is more convenient. The cradle receives data from the scanner via connectors in the bottom of the scanner and the top of the cradle. It then transmits that data to the host device through an attached cable. The cradle also provides power for charging the scanner’s battery pack (in the scanner). The cradle has a charge status indicator light.
There are two versions of the cradle available:
• PL 460 Cradle: the batch retail version
• PL 360 Cradle: the batch industrial version
This Quick Reference Guide provides basic instruction on the set up and use of the cradle. Unless otherwise noted, the term PhaserLink refers to all versions of the cradle.

Equipment Supplied

The equipment supplied is:
• Two Screws (for wall mounting)
• One Velcro Strip (for desk mounting)
• Four Rubber Feet (for desk mounting)
•This Guide
•Cradle
Save the shipping container for storing or shipping. Inspect all your equipment for damage. If anything is damaged or missing, call your authorized Customer Support Representative immediately.

Related Documentation

Phaser Series Scanner Product Reference Guide,
p/n 70-33629-xx
P 360/460 Memory Scanner Quick Reference Guide,
p/n 70-33628-xx
1
PL 360/460 Cradle

Parts of the Cradle

This figure shows the parts of the PhaserLink Cradle:
Scanner Support Ta b
Charging/ Communications Contacts
Charging LED Indicator
COM 1
COM 2
Wal l­mounting Socket 1
Power Port
Wall ­mounting Socket 2
2
Quick Reference

Connecting To The Host

On the bottom of the cradle are three ports -
COM 1
COM 2
COM 1 connects to the host computer, COM 2 is used for daisy­chaining multiple cradles together, and the Power Port supplies power to the cradle.
1. Insert the independent power plug into the Power Port (the cradle cannot be powered by the host computer).
Power Po rt