Zamel RTS-02 Manual Instruction

OPERATION AND FUNCTIONALITY
In the operation mode where a room temperature sensor and a oor temperature limiter are used (position 8 of the conguration menu), pressing and hold­ing the button for 3 seconds causes current oor temperature displayes. In case the sensor is not mounted or is damaged - Er symbol will be displayed.
7) Current day and time adjustment.
● Momentary pressing of the button causes the hour pulsates.
● Choose proper hour and AM / PM symbol by pressing and holding ▲ and ▼ buttons (AM shows time since midnight, AM shows time since noon).
● After choosing the hour press again the button. Minutes should pulsate.
● Choose proper minutes by pressing and holding ▲ and ▼ buttons.
● After choosing the minutes press again the button. The days of the week should pulsate.
● Choose a proper day by pressing and holding ▲ and ▼ buttons. Press once button. The display should show proper time and day. if no button is pressed
within 20 seconds the regulator switches to the operation mode according to the adjusted programme
8) Programme planning.
It is recommended to see the default settings of Times and temperatures in an exemplary schedule. If the programme is suitable press button so the regula­tor starts operation according to the default settings. To change the adjusted times and temperatures follow the below description. Specify demanded times and temperatures. Four time intervals must be programmed per one day. Temperature and starting time of the heating phase can be chosen independently. (For example, following settings can be chosen: 05:00 AM and 21°C for the beginning of the rst heating time-interval for a workday, and also 07:00 AM and 16,5°C for the rst cooling time interval). It is recommended to write all time intervals and temperatures for all intervals in a table. A complete table enables to save the user’s programme.
Heating schedule (programme default setting):
Time interval
Heating
9) Heating programme introduction
1. Press once button . „PRGM SETTING” command displays. Pulsating symbols of weekdays „Mon Tue Wed Thu Fri” will be shown on a display with
currently programmed start times for the rst heating time interval. The temperature for this interval will also be shown. The icon programming of the rst time interval (Get up).
2. Press button  to adjust programmed time and temperature. Press button once (programmed temperature value will be displayed in a pulsating way).
Press ▲ and ▼ buttons to change the displayed temperature for the rst heating time interval.
3. Press button  once (programmed time value will be displayed in a pulsating way). Press ▲ and ▼ buttons to adjust the demanded time. Time displayed
changes in a 15 minutes way. Press TIME button again after demanded time was chosen to return to the temperature change mode.
4. Press button once. The icon
and temperature for the second heating time interval.
5. Repeat steps 2 and 3 to adjust parameters for the second time interval of the programme.
6. Repeat steps from 2 to 5 for the third and fourth time intervals of the programme.
7. Press button  once. „SA” symbol is displayed (programming for Saturday). The display also shows currently adjusted start time and temperature for
the rst heating time interval.
8. Repeat steps from 2 to 7 to insert programme data for Saturday.
9. Press button once to adjust Sunday („SU”) and repeat steps from 2 to 7 to insert programme data for Sunday.
10. Press button after inserting all data for the heating programme.
10) Return to the default settings.
Press button  to enter the programming mode. Press simultaneously ▲ and ▼ buttons for 3 seconds. „DEF” symbol is displayed three times (it pulsates), the programme returns to the setting phase. Press button so the regulator can start operation according to the default setting. In case no button is pressed within 20 seconds the regulator returns to the operation mode compatible with the adjusted programme.
11) Control of the adjusted programme.
In order to check the adjusted programme settings before the programme starts, it is recommended to follow the below description. Press button to to check the rst time interval data for a working day. Pressing button every time makes times and temperatures are displayed for the following time interval (sequentially) for working days, and next for Saturday and Sunday (every time and temperature can be changed while reviewing). Press button so the regulator can start operation according to the adjusted programme.
Days of the week (5 days) Saturday Sunday
Start time Temperature Start time Temperature Start time Temperature
6:00 AM 21 °C 6:00 AM 21 °C 6:00 AM 21 °C
8:00 AM 16,5 °C 8:00 AM 16,5 °C 8:00 AM 16,5 °C
5:00 PM 21 °C 5:00 PM 21 °C 5:00 PM 21 °C
10:00 PM 16,5 °C 10:00 PM 16,5 °C 10:00 PM 16,5 °C
signals about
for the second time interval programming is displayed (Go out). The display also shows currently adjusted start time
WARRANTY CARD
There is 24 months guarantee on the product
Salesman stamp and signature, date of sale
1. ZAMEL Sp. z o.o. assures 24 months guarantee for the product.
2. The manufacturer’s guarantee does not cover any of the following actions: a) mechanical damage during transport, loading / unloading or under other circumstances, b) damage caused by incorrect product mounting or misuse, c) damage caused by unauthorised modications made by the PURCHASER or any third parties to the product or any other devices
needed for the product functioning,
d) damage caused by Act of God or any other incidents independent of the manufacturer - ZAMEL Sp z o.o.
e) power supply (batteries) to be equipped with a device in the moment of sale (if they appear);
3. The PURCHASER shall lay any claims in writing to the dealer or ZAMEL Sp. z o.o.
4. ZAMEL Sp. z o.o. is liable for processing any claim according to current Polish legislation.
5. ZAMEL Sp. z o.o. shall process the claim at its own discretion: product repair, replacement or money return.
6. The manufacturer’s guarantee is valid in the Republic of Poland.
7. The PURCHASER’s statutory rights in any applicable legislation whether against the retailer arising from the purchase contract or
otherwise are not affected by this warranty.
MATEC – ELECTRIC HEATING SYSTEMS
TEMPERATURE CONTROLLER RTS-02
ZAMEL Sp. z o.o.
ul. Zielona 27, 43-200 Pszczyna, Poland
tel. +48 32 449 15 00, +48 32 210 46 65, fax +48 (32) 210 80 04
www.zamel.com, e-mail: matec@zamel.pl
TECHNICAL DATADESCRIPTION
RTS-02 temperature controller is a pro-
grammable regulator. It is used to heat oors
and to limit oor’s temperature. The device
cooperates with electric and water oor heat-
ing systems. RTS-02 is equipped with battery
supply backup (2 x AA battery).
FEATURES
• a big LCD display;
• the LCD display shows simultaneously the
adjusted temperature and the room tem-
perature;
• user’s settings and default settings are kept
in a non-volatile memory;
• temperature is displayed in: Celsius or Fahrenheit (temperature) scales;
• 3 control modes - MODE A: - control by means of a room sensor, MODE F: - con­trol by means of a floor sensor, MODE AF:
- control by means of a room sensor with floor temperature limitation;
• separate programming possibility for 5 weekdays and for a cycle of 1 day / 1 day (Saturday/Sunday);
• programming with four separate time inter­vals / temperature intervals during a day;
• calibration possibility of a displayed tem­perature value;
• protection against freezing;
• pump protection.
The device is designed for single-phase
installation and must be installed in ac
CAUTION!
connected according to the details included in this operating manual. Installation, connection and con trol should be carr ied out by a qualied electri cian
staff, who act in accordanc e with the service manual and the device functions.
In case of casing dismantling an electric shock may occur, and the guarantee is lost then. Before instal
lation make sure the connection cables are not un-
der vo ltage. The c rucifo rm head screwdriver 2,5 mm
should be used to instal the devic e. Improper trans
port , storage, an d use of the device inuence its wrong func tioning. It is not advisable to instal the device in the following cases: if any device part is missing or the device is damage d or deforme d. In case of improper functioning of the device contact
the producer.
cordance with standards valid in a par­ticular countr y. The device should be
The symbol means selective collecting of electrical and electronic equipment. It is forbidden to put the used equipment together with other waste.
Room temperature adjustment range: +5 ÷ +50 °C
Accuracy of temperature measurement: ±1 °C
APPEARANCE
1. Power supply button (Switch on / Switch off).
2 A bi-functional button to display the room temperature,
the oor temperature and time adjustments.
-
3 Default settings button.
4 Programme start conrmation button.
5 Reset button.
-
6 Maximum temperature adjustment button.
7 Minimum temperature adjustment button.
-
-
25
24
23
the remaining time to wake up time to go and rest programme setting adjustment mode. 22. Cofg: Signalling of regulator’s conguration mode. 23. Signalling of the cur­rent regulator’s operation mode. 24. Signalling of the holiday temperature mode. 25. Current room temperature display.
8 9 10 11 12
Input (supply) terminals: L, N
Input rated voltage: 100 ÷ 240 V~
Nominal frequency: 50 / 60 Hz
Nominal power consumption: 0,40 W – STANDBY
Battery backup: Yes (2 x AA battery)
NTC senor terminals: RT2+, RT2-
Temperature sensor: NTC 100k dla 25 °C
Floor temperature control range: +5 ÷ +50 °C
Adjustment accuracy: ±0,5 °C
Output type: relay 16A dla 250 VAC
Number of terminal clamps: 7
Section of connecting cables: 0,5 ÷ 1,5 mm
Ambient temperature range: -5 ÷ +50 °C
Casing mounting: surface
Casing protection degree: IP21
Protection level: II
Overvoltage category: II
Dimensions: 90 x 115 x 29 mm (height x width x depth)
Reference standard:
1819202122
, the remaining time to leave , the remaining time to return , the remaining
. 20. Day / time adjustment: current time and day display. 21. Prog setting: Signalling of the
MANUAL INSTRUCTION
RTS-02
Weight: 0,180 kg
1617
2
ETSI EN301 489-1, ETSI EN301 489-3, EN 60730-1:2000+A12:2003, EN 60730-2-9:2002
8. Current day or programmed days display. 9. Cur- rent time or programmed time display. 10. Am: time in- dication: morning and afternoon, Pm: time indication: afternoon and evening, Days: number of days, Hours:
number of hours. 11. Temperature scales display: Cel-
13
sius (°C) or Fahrenheit (°F). 12. Temperature adjust­ment range. 13. Temperature limit excess in AF mode
14
signalling.14. Regulator’s programming mode signal­ling. 15. Pump protection mode signalling. 16. 16-A: Signalling of the mode operation with a room tempera-
15
ture sensor, 16-F: Signalling of the mode operation with a oor temperature sensor, 16-AF: Signalling of
the mode operation with a room temperature sensor
and a oor temperature limiter. 17. Heating switch on signalling. 18. Standby symbol. 19. Time ranges:
plik: inst_cet_en_rts-02 | modykacja: 20.04.2017
REGULATOR’S MOUNTING PLACE
● The regulator should be installed in a heated room - flat surface mounting,
Regulator
● Mounting height: about 120 cm from the heated floor surface,
● The regulator should be mounted in a place without a direct sunlight and strong draughts,
● Temperature in mounting places should not exceed values given in technical parameters T = -5 °C ÷ +50 °C,
● Mounting of RTS-02 temperature regulator is shown in the attached diagram.
Heating mat
CAUTON: In case the oor sensor was not mounted or was damaged during mounting phase, the regulator switches off the output that controls heating in AF MODE.
TEMPERATURE REGULATOR MOUNTING
1. Undo 2 mounting screws from the regulator’s base. Carefully separate the
Wall mounting screws
control panel from the base. Pressing or levering the regulator can dama­ge the regulator’s module.
2. Floor sensor cable should be connected to RT2+ and RT2- terminals on a
terminal strip (see gure). In case the oor sensor was not mounted or was damaged during mounting phase, the regulator switches off the output that controls heating in AF MODE, and when the oor temperature command
is chosen - Er symbol is displayed.
3. Connect power supply and load cables with the terminals left on the ter-
minal strips which is placed on the regulator’s base (gure). Place the supplying base to the wall.
4. Mount the base to the wall by means of two mounting screws. (Levelling guarantees only the good look of the mounted device and do not inuence
Base
proper working of the regulator).
5. Place the control panel back in the base. Mount the control panel to the base by means of two screws described in point 1.
Control panel
Mounting screws
RT2-, RT2+: oor sensor terminals
N, L: power supply terminals
T1, T2: load terminals
Figure - terminal block description of the RTS-02 regulator
RT2- N T1 T2 LRT2+
CONTROLLER’S OPERATION MODES
The regulator can operate in three modes, which can be chosen by pressing 8 of the conguration menu.
MODE A: a regulation mode by means of a room temperature sensor; In this mode an (internal) air sensor of the regulator is used. The device switches on and switches off the oor heating or another heating system based on a comparison of the demanded temperature and the room temperature. Heating should start immediately when the demanded temperature is 1 °C higher than the room temperature in the fast heating mode or 3 °C higher than the room temperature in the slow heating mode.
MODE F: a regulation mode by means of a oor temperature sensor; This mode is used in case there is no inner oor sensor and there is no possibility of its mounting.
Application
Preserving the same oor temperature in bathrooms and rooms where a warm surface is demanded. In this mode there is an external oor sensor control. The heating is switched on and switched off on the basis of a comparison of the demanded temperature with the current oor temperature. The heating should start when the demanded temperature is 1 °C higher than the oor temperature in the fast heating mode or 3 °C higher than the oor temperature in the slow heating mode.
Caution: In case the oor sensor was not mounted or was damaged during mounting phase, the regulator blocks the output that controls heating in F MODE. Er symbol will be displayed in the oor temperature place.
MODE AF: a regulation mode by means of a room sensor and a oor temperature limiter; AF mode is a normal operating mode in oor heating systems.
Floor sensor cable should be connected to RT2+ and RT2- terminals on a terminal strip. In case the oor sensor is not mounted, a pulsating symbol Alarm will be displayed and the regulator blocks the output that controls heating. Er symbol will be displayed in the oor temperature place.
In AF mode the regulator switches on and switches off the heating on the basis of a comparison of the room temperature, the demanded temperature and the adjusted oor temperature limit with a current oor temperature. Minimum and maximum oor temperature limit is adjusted by choosing positions 3 or 4 in the conguration menu. If the oor temperature is between the upper and the bottom temperature limit, heating should start immediately if the demanded temperature is 1 °C higher than the current room temperature in the fast heating mode or 3 °C higher than the current room temperature in the slow heating mode. In case the oor temperature exceeds the adjusted upper limit the heating will be switched off and a pulsating symbol Alarm will be displayed. In case the oor temperature lowers below the adjusted bottom limit the heating should switch on and a pulsating symbol Alarm will be displayed. If the oor tem­perature exceeds the upper adjusted limit - Hi symbol will be displayed; if the oor temperature will be below the bottom limit - Lo symbol will be displayed. A pulsating symbol Alarm will also be displayed.
FUNCTIONING
Conguration menu
Conguration menu enables the adjustment of some heating system values and user demand values. In order to enter the conguration menu switch the temepature controller into position OFF (protection against freezing) by pressing button, and next holding button for 3 seconds.
The rst position of the conguration menu appears on the display. Press
button to enter the next menu position. Change the position value by means of
▲ and ▼ buttons. Press button to escape from the conguration menu. Press the button to enter the operation mode according to the adjusted pro­gramme. If no button is pressed within 20 seconds the menu is automatically closed. In order to return to the default settings enter the conguration menu to press and hold for 3 seconds ▲ and ▼ buttons simultaneously. „DEF” command appears three times on the display, and position 1 of the menu will be displayed to indicate that all conguration settings are default.
Conguration menu table shows all conguration options:
Pos Pressed
10
button
1
2
3
4
5
6
7
8
9
Displayed command
(default settings)
01 (0) -3 --- +3 Increasing or lowering the displayed temperature value
02 (35 °C) 18 ÷ 35 °C Choosing the maximum room temperature setting
03 (5 °C) 5 ÷ 20 °C Choosing the minimum oor alarm temperature
04 (40) 20 ÷ 40 °C Choosing the maximum oor alarm temperature
05 ( °C) °C / °F Choosing Celsius or Fahrenheit (temperature) scales
06 (FA) FA / SL Choosing fast heating mode (FA) or slow heating mode (SL)
07 (OO) PP / OO Choosing pump protection function (PP). Switching off pump protection function (OO).
08 (AF) AF / F / A Choosing the operation mode: A: Regulation mode by means of a room temperature sensor.
09 (1) 1, 2, 3 Choosing the LCD backlight.
Choice range by means of
▲ and ▼ buttons
F: Regulation mode by means of a oor sensor. AF: Regulation mode by means of a room
sensor and a oor temperature limiter.
Press
button to return to the operation mode according to the adjusted programme.
Description
Explanation of particular options:
1) Recalibration of the displayed temperature in the range of -3 to +3 degrees. The displayed room temperature value can be changed to 3 degrees above
or below indications compatible with default settings for temperature measurement. The regulator was precisely calibrated, but there is a possibility to change the displayed value in order to adjust it, for example, to values of the previously used device by a user. The room temperature, current temperature or the adjusted tem­perature will be shown in the right part of the LCD display.
2) Choosing the maximum room temperature setting. This position enables to adjust the maximum room temperature. 35°C is the default setting. The adjustment can be changed in the range of 18 to 35°C by means of ▲ and ▼ buttons.
3) Choosing the minimum oor alarm temperature. Use ▲ and ▼ buttons to choose a demanded minimum limit temperature. The temperature can be changed in the range of 5 to 20 °C. 5°C is the default setting.
4) Choosing the maximum oor alarm temperature. Use ▲ and ▼ buttons to choose a demanded maximum limit temperature. The temperature can be changed in the range of 20 to 40 °C. 40°C is the default setting.
5) Choosing Celsius or Fahrenheit (temperature) scales. The temperature scale can be chosen either in Celsius or in Fahrenheit. Celsius is the default setting.
6) Choosing fast heating mode (FA) or slow heating mode (SL). FA mode: - the heating is switched on when the adjusted temperature is 1 °C higher than the
room temperature. SL mode: - the heating is switched on when the adjusted temperature is 3 °C higher than the room temperature.
7) Choosing pump protection function (PP). In case of water installation systems it is recommended to switch on the pump for at least 15 seconds every 24 hours,
it will protect the pump against seizing. Choose the PP position to activate the pump protection mode. Choose the OO position to switch off the pump protection mode. OO, 15 symbol is displayed during the pump protection mode is activated. OO is the default setting.
8) Choosing the temperature regulation mode. The regulator can operate in three modes: A, F and AF (AF is the default setting). A: Regulation mode by means of a room temperature sensor. F: Regulation mode by means of a oor sensor. AF: Regulation mode by means of a room sensor and a oor temperature limiter.
9) Choosing the LCD backlight.The backlight improves the contrast of the LCD display in poor light conditions. 1 is the default setting. 1 - the backlight is switched on by pressing any button of the regulator, 2 - backlight is switched off, 3 - he backlight is on continuously.
OPERATION AND FUNCTIONALITY
1) Activation of the anti-freezing mode (anti-freezing) / switching off the device.
In a sufciently warm climate, a user can switch off the regulator or activate the anti-freezing mode by pressing button.Quick pressing of the button ac- tivates the anti-freezing mode, the display shows the hour, the weekday and the room temperature. 5°C is the default setting of the anti-freezing temperature. In this mode a temperature fall in a room up to 5°C causes the heating switches on until the temperature reaches 9°C. In cases of installation systems with hot water by choosing PP option (position 7 in the conguration menu), the device activates the pump for at least 15 seconds once per 24 hours in order to avoid its seizing. Pressing shortly again the power supply button causes the anti-freezing mode switches off and a return to the standard operation mode. Pressing and holding the button for 3 seconds causes the device switches off.
2) Functioning according to the adjusted programme and operation in a mode to preserve the temperature at the same level.
After a momentary pressing of the button the regulator controls the heating system according to the adjusted programme. „Prog running” command on the display signals about the regulator’s operation which is compatible with the adjusted programme. Pressing and holding the button for 3 seconds causes the regulator changes its mode to preserve the temperature at the same level. In this mode the regulator preserves the room temperature according to the previously adjusted value. „Hold” command on the display informs about regulator’s operation in this mode.
3) Change to a manual operation of the temperature.
Pressing ▲ and ▼ buttons during operation of the adjusted programme enables a user to choose a demanded temperature. The new setting deletes tempera­ture values chosen for the programme in progress and forces the temperature to be kept at a chosen level until the programme switches to the next phase (the next time-interval). After the new phase has started the regulator starts operation according to the adjusted programme.
4) Preserving the holiday temperature.
Pressing and holding the button for 3 seconds causes vacation command appears on the display. It informs that the regulator changed to the previously adjusted holiday temperature. By means of button the number of the days (from 1 to 99) can be increased, and pressing the button can decrease the number of the days. Pressing ▲ and ▼ buttons choose required holiday temperature. Pressing the  button enables to return to the operation of the adjusted programme.
5) Device reset.
If the information on the display is shown incorrectly, gently press the reset button. Reset with the help of an object with a thin tip, for example, a straightened
paper clip. This will reset the regulator’s settings.