Zamel ROW-01 Instruction Manual

1
ZAMEL ROW-01
FITTING INSTRUCTION MANUAL
2
Content
Technical data ......................................................................................................................................... 4
Installation remarks ................................................................................................................................. 5
Mounting ................................................................................................................................................. 5
Registry .................................................................................................................................................... 8
ROW-01 module configuration ............................................................................................................... 9
Installation and configuration of SUPLA on smartphones or tablets .................................................... 13
3
Welcome,
On behalf of the whole Zamel team, we would like to thank you for choosing our product. Remember, this is an electronic device with mains power supply, so keep in mind all safety rules during mounting. Make sure there is no voltage on the connection cables by means of a special measuring equipment before mounting. We did our best to make the product operates properly. But, if you have any remarks regarding the device, its functionality, casing or instruction, etc., we will implement your ideas and create a reliable product. Feel free to contact us by means of an e-mail – we will certainly answer.
ZAMEL Team
supla@zamel.pl
4
Technical data
Nominal voltage supply:
230 VAC
Nominal frequency:
50 / 60 Hz
Nominal power consumption:
0,45 W
Transmission:
Wi-Fi
Operation range:
do 200 m in the open area
Number of external inputs:
2
Cooperation with switches:
monostable (push-buttons) bistable (standard lighting switches without backlight)
Number of output channels:
1
Relay contact parameters:
(voltage free NO contact)
1 x NO 5A / 250 VAC
Maximum output load:
1 x 5A / 250 V AC
incandescent and halogen lamps – 750
W
CFL lamps – 250
W
LED lamps–
60 W
Number of terminal clamps:
6 (cross-section of wires up to 2,5 mm2)
Casing mounting:
Ø60 mm junction box
Temperature operation range:
-10 do +55 °C
Casing protection degree:
IP20
Protection class:
II
Dimensions:
47,5 x 47,5 x 20 mm
Weight:
0,04 kg
Reference standard:
PN-EN 60669, PN-EN 60950, PN-EN 61000 PN-ETSI EN 300 220-1
5
Installation remarks
Do not mount the ROW-01 module in close proximity to each other (if possible, keep 15 cm distance). Particularly avoid mounting one receiver over the another one. It can cause the Wi-Fi connection disturbances.
It is important to obey maximum output loads:
• incandescent and halogen lamps: 750 W / channel
• CFL lamps: 250 W / channel
• LED lamps: 60 W / channel
During installation, pay attention the module is not exposed to a direct influence of water and to operation in increased humidity. Ambient temperature in the mounting place should be within the following range: -10 do +55°C.
ROW-01 module is designed to be installed indoor. During outdoor installation, it is necessary to place the device in an additional hermetic casing.
Installation switches used in a wired control can be connected to IN1 and IN2 inputs of the ROW-01 receiver. The inputs are designed to cooperate with monostable or bistable switches. By default, the IN1 input operates in the monostable mode (doorbells), and the IN2 input in the bistable mode (for standard lighting switches without backlight).
After installation, check proper operation of the receiver, and watch if the LED diode switches on.
Mounting
ROW-01 module is designed to be used in flush mounting. The casing dimensions enable its mounting in flush (minimum Ø60) and surface junction boxes. In case of flush mounting, the use of deepened junction boxes is recommended.
The device is designed for a single-phase installation and must be installed in accordance with standards valid in a particular country. Installation, connection and control should be carried out by a qualified electrician staff, who act in accordance with the service manual and the device functions. For safety reasons, do not mount the device without casing or with a damaged one, as an electric shock may occur.
CAUTION! Before installation make sure the connection cables are not under voltage.