APPEARANCE
according to th e details in­cluded in this operating manual. Installation, connection and control should be carried out by a qualied electrician staff, who act in acco rd­ance with the ser vice manual and t he device functions. Di sassembling of the devic e is equal with a loss of guara ntee and can cause el ec­tric shock. Before installation make sure the connection c ables are not under voltage. The cruciform h ead screwdriver 3,5 mm should be used to instal the d evice. Improper tr ansport,
storage, and use of the device in uence its
wrong functio ning. It is not advisa ble to instal the device in the fo llowing cases: if any device part is missin g or the device is damaged or d e­formed. In case o f improper functioning of the device contact the producer.
CAUTION
FEATURES
TECHNICAL DATADESCRIPTION
● cooperation with wireless EXTA FREE
control system transmitters,
● 1 NO/OC output relay (dry contacts),
● lighting, heating operation control,
● easy junction box Ø 60 mm installation,
● 5 operation modes: switching on, swit-
ching off, monostable mode, bistable mode, time mode (switch off delay),
● wide operation range (up to 230 m),
● operation is optically signalled,
● low current consumption, possibility of
constant operation,
● possibility of increasing operation ran-
ge by means of RTN-01 retransmitter.
Radio receivers are used both as el-
ements in mounting in ush and surface
installation cable boxes and as an ac-
tuator built directly in lighting ttings and
other receivers. ROP-01 enables opera­tion in 5 different modes (switching on, switching off, monostable mode, bistable mode, time mode.)
ROP-01
Input (supply) terminals: L, N
Input rated voltage: 230 V AC
Input voltage tolerance: -15 ÷ +10 %
Nominal frequency: 50 / 60 Hz
Nominal power consumption: 0,29 W
Number of operation modes: 5
Number of channels: 1
Transmission: radio 868,32 MHz
Transmission way: unidirectional
Coding: addressing transmission
Maximum number of transmitters: 32
Range: up to 230 m in the open air
Time adjustment: 1 second ÷ 18 hours (every second)
Optical signalling of transmitter’s operation: red LED diode
Relay output clamps: 12, 11, 14
Relay contacts parameters: 1NO/NC 5A / 250V~ AC1 1250 VA
Number of terminal clamps: 5
Section of connecting cables: up to 2,5 mm
2
Ambient temperature range: -10 ÷ +55 oC
Operating position: free
Casing mounting: junction box Ø 60 mm
Casing protection degree: IP20 (EN 60529)
Protection level: II
Overvoltage category: II
Pollution degree: 2
Surge voltage: 1 kV (EN 61000-4-5)
Dimensions: 47,5 x 47,5 x 20 mm
Weight: 0,043 kg
Reference standard: EN 60669, EN 60950, EN 61000
The symbol means selective collecting of electrical and electronic equipment. It is forbidden to put the used equipment together with other waste.
Optical signalling of receiver’s operation
Programming buttons
Relay output terminals (12, 11, 14)
Input (supply) terminals (L, N)
CONNECTION
APPLICATION
1-channel radio receiver ROP-01 operates as a receiv­er of 8-channel remote con­troller P-256/8 and of 2-chan­nel button radio transmitter RNK-02 (light sources switch
on/switch off control).
The above mentioned trans­mitters can also control op­eration of radio lighting switch RWL-01 and remote control socket RWG-01.
CAPACITY
750W
250W
500W
375W
MOUNTING
1. Disconnect power supply by the phase fuse, the circuit-breaker or the switch-disconnector combined to the proper circuit.
2. Check if there is no voltage on connection cables by means of a special measure equipment.
3. Connect the cables with the termi­nals in accordance with the install­ing diagram.
4. Install ROP-01 device in installa­tion cable box.
5. Switch on the power supply from the mains.
WARRANTY CARD
There is 24 months guarantee on the product
1. ZAMEL provides a two-year warranty for its products.
2. The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances
b) defects resulting from incorrect installation or operation of ZAMEL products; c) defects resulting from any changes made by CUS­TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold; d) defects resulting
from force majeure or other aleatory events for which ZAMEL is not liable; e) power supply (batteries) to be equipped with a device
in the moment of sale (if they appear);
3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect.;
4. ZAMEL will review complaints in accordance with existing regulations.;
5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL.
6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy between the goods and the contract.
Salesman stamp and signature, date of sale
The ZAMEL company devices which
are characterised with this sign can
cooperate with each other.
VER. 005_20.05.2011
COOPERATION AND OPERATION RANGE
Symbol ROP-01 ROP-02 ROB-01 SRP-02 SRP-03 RWG-01 RWL-01 ROM-01 ROM-10 RDP-01 RTN-01
RNK-02 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m
RNK-04 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m
P-256/8 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m
P-257/4 (2) 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m
RNM-10 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m
RNP-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m
RNP-02 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m
RNL-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m
RTN-01 200 m 200 m 200 m 200 m 200 m 250 m 200 m 250 m 250 m 200 m 250 m
RCR-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m
RTI-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m
RXM-01 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m
* - 1-channel transmitters do not cooperate with roller blinds controllers.
CAUTION: The given range concerns open area - an ideal condition without any natural or articial obstacles. If there are some obstacles between a transmitter and a receiver,
it is advisable to decrease the range according to: wood and plaster - from 5 to 20, bricks - from 10 to 40%, reinforced concrete - from 40 to 80 %, metal - from 90 to 100% , glass - from 10 to 20%. Over- and underground medium and high electrical power lines, radio and television transmitters, GSM transmitters set close to a device system have
also a negative inuence on the range.
TRANSMITTERS RECEIVERS
RNK-02
2–channel button radio transmitter
RNL-01
Radio foot transmitter
ROP-01
1-channel radio receiver
RWL-01
Radio lighting switch
RNK-04
4-channel button radio transmitter
RTI-01
IR/EXTA FREE
transceiver
ROP-02
2-channel radio receiver
RWG-01
Remote control socket
P-256/8
8-channel remote controller
RNM-10
4-channel radio modular transmitter
RDP-01
1-channel radio dimmer
SRP-02
Radio roller blinds controller
P-257/4
4-channel remote controller
RNP-01
4-channel radio transmitter
ROB-01/12-24V
Radio gate controller
SRP-03
Central radio roller blinds controller
P-257/2
2-channel remote controller
RNP-02
4-channel radio transmitter
ROM-01
1-channel radio modular receiver
ROM-10
2-channel radio modular receiver
RCR-01
Radio motion sensor
RXM-01
Translator
RS-485/EXTA FREE
ACCESSORIES
ANT-01
External antenna
RTN-01
Retransmitter
OPERATION
The device can operate in ve modes:
MONOSTABLE
the relay operates only while pressing transmit­ter’s push-button.
BISTABLE
(one push-button) the device changes relay status cyclically always
after pressing the same push-
-button.
SWITCH ON
the device switches on after pressing the push-
-button.
SWITCH OFF
the device switches off after pressing the push-
-button.
TIME
the device switches off according to the
adjusted time (tp),
but it may be switched off before
adjusted time nishes. Default
settings - 15 seconds.
CAUTION! Adjusted time can not be deleted.
RADIO TRANSMITTERS PROGRAMMING
TIME PROGRAMMING
RADIO TRANSMITTERS DELETION
MONOSTABLE mode:
BISTABLE mode:
SWITCH ON/SWITCH OFF mode (two push-buttons):
TIME mode (one push-button)
An exemplary programming procedure with the use of P-257/2 remote controller. The procedure for the rest of radio EXTA FREE transmitters is analogous.
CAUTION: Every transmitter can cooperate with ROP-01 in a different mode, depending on how they were added to the device. One transmitter can be added during one programming cycle. Full memory is signalled with pulsating LED red diode.
Press transmitter’s
push-button for
a longer time.
Press the transmitter’s push-button
for a longer time. LED red diode switches
on (rst signal pulsates, next the signal is
constant).
Press and release transmitter’s push-
button. LED red diode switches on
(the signal pulsates, next the signal is
constant).
Press and release transmitter’s push-
button. LED red diode switches on
(rst signal pulsates, next the signal is
constant).
Release transmitter’s
push-button. LED red diode
switches on (rst signal
pulsates, next the signal is
constant).
Release transmitter’s push-button.
LED red diode switches on (the
signal pulsates), next the LED red
diode switches off - it means the
TRANSMITTER IS ADDED.
Press and release the same transmitter’s
push-button. LED red diode
switches on (the signal pulsates)
and next it switches off -
THE TRANSMITTER IS ADDED.
Press and release the same transmitter’s
push-button. LED red diode switches on (the signal pulsates) and next it switches
off - THE TRANSMITTER IS ADDED.
Press the same transmitter’s push-
-button and release it. LED red dio­de switches on (the signal pulsates)
and next it switches off -
THE TRANSMITTER IS ADDED.
Press PROG push-button of ROP-01 device
for a longer time until LED red diode switches on
(constant signal). Next release PROG push-button.
Press PROG push-button of ROP-01 device
for a longer time until LED red diode switches on
(constant signal). Next release PROG push-button.
Press PROG push-button of ROP-01 device
for a longer time until LED red diode switches on
(constant signal). Next release PROG push-button.
Press PROG push-button of ROP-01 device
for a longer time till LED red diode switches on
(constant signal). Next release PROG push-button.
Maximum time is 18 hours.
Press PROG push-button of ROP-01 device for a longer time till
LED red diode switches on (constant signal). Next release PROG
push-button. Wait (for about 5 seconds) till LED red diode switches
on (rst signal pulsates, next the signal is constant).
After the adjusted time is
nished (the number of LED
red diode ashes) press
PROG push-button and then
release it - TIME IS ADDED.
Press PROG push-button of ROP-01 device and then release it. LED red diode switches
off and then switches on (signal pulsates).
Every LED diode pulse equals 1 second.
1s 2s ns
Press PROG push-button of ROP-01 device
for a longer time.
After 5 seconds LED red diode switches on
(signal pulsates) and then it switches off.
Release the push-button in ROP-01 -
MEMORY IS DELETED.