This product was manufactured
in a plant whose quality system
is certified/registered as being
in conformity with ISO 9001.
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.ari.org
TM
O
T
A
D
R
E
I
I
A
F
S
I
T
R
C
E
O
C
M
A
T
I
N
U
C
E
R
T
I
A
R
Y
R
R
E
Q
U
I
P
F
I
C
A
T
I
N
O
I
S
T
A
N
D
with ARI.
P
L
Y
H
E
A
T
G
P
U
M
P
T
F
N
E
M
O
S
N
O
I
T
C
E
S
0
4
2
D
R
A
R
E
R
U
T
C
A
F
U
N
A
M
Certification applies only
when the complete
system is listed
I
N
LISTED
036-21030-003 Rev. B (0203)
DESCRIPTION
The EFD Series heat pump is the outdoor part of a versatile system designed to economically heat and cool a home or small business. The compact design of these outdoor units make them ideal
for ground or roof installation. They are available with sweat connect field piping connections. These units have service valves and
contain enough refrigerant charge for the outdoor unit, a matching
indoor coil and 15 feet of interconnecting piping.
EFD heat pumps may be custom-matched with one of YORK's
indoor line of evaporator blower sections, each designed to serve
a specific function. Electric heaters are available for both single
and three phase applications, in a variety of sizes.
For Add-On applications, the indoor coil may be applied in the
supply duct of a conventional gas, oil or electric furnace. The heat
pump will be the primary source of heat for the building with the
furnace operating only when the heating requirement exceeds the
capacity of the heat pump.
WARRANTY
5-year lim
5-year limited co
ited parts warranty.
mpressor warranty.
FEATURES
• QUALITY CONDENSER COILS - The coil is constructed of
enhanced copper tube and aluminum fins.
• COIL PROTECTION - Coils are protected from damage by a
polymer mesh applied between the coil face, and a PVC coated
steel coil guard.
• DEFROST CONTROL - Time / Temperature defrost control
provides field selectable time periods between defrost cycles
(30, 60 and 90 minutes). LED lockout indicator, anti-short cycle
timer protection are also provided. A built-in soft lockout helps
to avoid nuisance trips on high pressure.
• PROTECTED COMPRESSOR - The compressor is internally
protected against high pressure and temperature. This is
accomplished by the simultaneous operation of high pressure
relief valve and a temperature sensor which protect the compressor if undesirable operating conditions occur. All units have
standard crankcase heat for added protection (except 048 and
060, since they are scroll compressors).
• DURABLE FINISH - Cabinet is made of pre-painted steel. The
pre-treated flat galvanized steel provides a better paint to steel
bond, which resists corrosion and rust creep. Special primer
formulas and glossy earth tone finish insure less fading when
exposed to sunlight.
• LOWER INSTALLED COST - Installation time and costs are
reduced by the fully exposed refrigerant connections and the
single panel covering of the electrical controls. The small base
dimension means smaller mounting pads or less materials
required for mounting, thus lowering installation costs.
• TOP DISCHARGE - The air from the top mounted fan is blown
up away from the structure and any landscaping. This allows
space saving arrangements of multi-unit installations.
• LOW OPERATING SOUND LEVEL - The upward air flow carries the normal operating noise up and away from the living
area. The rigid top panel effectively isolates any motor sound.
Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and compressor operating sounds. A compressor blanket accessory is available for
those applications requiring further sound reduction.
• LOW MAINTENANCE - Long life permanently lubricated
motor- bearings need no annual servicing.
• RE-USABLE SERVICE VALVES - Provided on all sweat fit-
tings on both the liquid and vapor connections for ease of evacuating.
• U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
1. Rated in accordance with ARI Standard 110, utilization range “A”.
2. Dual element fuses or HACR circuit breaker.
3. All scrolls listed with a superscript “B” are Bristol scrolls. All scrolls listed with a superscript “C” are Copeland scrolls.
4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than
15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
B
2Unitary Products Group
Page 3
036-21030-003 Rev. B (0203)
Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 & 3 Phase
ID Orifice included w/Instruction Package5361677578, 8184, 8793
INDOOR COIL
COIL ORIFICE
1
G1FA/G1UA024S14, 175953+2------
G1FA/G1UA030S146553+561+0-----
G1FA/G1UA036S1473-61+267+0----
G1FA/G1UA036S1773--67+5----
G1FA/G1UA048S1784---75+381+584+0-
G1FA/G1UA048S2184---75+581+584+0-
G1FA/G1UA060S21, 2490-----87+793+0
G2FD024(S,H)14, 176153+561+0-----
G2FD030(S,H)1765-61+267+0----
G2FD035(S,H)1465-61+267+0----
G2FD036(S,H)17, 2175--67+575+0---
G2FD042(S,H)2178--75+178+0--
G2FD046(S,H)1778---75+378+0--
G2FD048(S,H)21, 2484----81+584+2-
G2FD060(S,H)2490-----87+493+0
G2FD061SH2490------93+8
G1HD0245953+561+1-----
G1HD03669--67+575+0---
G1HD04881----78+287+0-
G1HD06093----81+987+093+8
F2RP/FP0185353+0------
F2RP/FP0246153+461+0-----
F2RP/FP03065-61+267+0----
F2RP/FP03675--67+575+0---
F2RP/FP04278---75+378+0--
F2FP04884----81+584+2-
F2FP06090------93+0
REFRIGERANT LINE ADDER OZ. / FT.0.660.660.680.680.680.700.70
FOOTNOTES:
1. These orifices are factory mounted in the flow control device of each indoor coil.
REQUIRED SYSTEM ORIFICE + ADDITIONAL CHARGE, OZ.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaportor and for 15 feet of interconnecting line
tubing.
2. Verify the orifice size and additional charge required for specific evaportor coil in the system using the above table.
3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above.
4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for
evaportor + adder for line set.
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210/240.
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters.
3. TXV = Use 1TV700 Series Kit.
4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC
5. FG8, FG9, and FL8 furnaces and F2RP / F2FP/F2FV air handlers have B.O.D (Blower on Delay) standard.
2. Heating performance and efficiency is the same for TXV application. Heating MBH based on 70° DB entering indoor air, 72% RH outdoor air with 25 feet of
interconnecting piping and no supplemental electric heat operation.
3. Integrated heating capacities include the effect of defrost cycles in the temperature range where they occur.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature.
Air HandlerCoil
N1AHB08G2FD024(S,H)171.031.031.00
N1VSB12G2FD024(S,H)171.071.071.00
F2RP/F2FP0241.011.011.06
G1UA024S141.021.021.06
G1UA024S171.021.021.06
G2FD024(S,H)141.031.031.06
G2FD024(S,H)171.031.031.06
G1UA030S141.031.031.06
G1HD0241.011.011.06
G1FA024S141.021.021.06
G1FA024S171.021.021.06
G1FA030S141.031.031.06
T.C.S.C.KW
10Unitary Products Group
Page 11
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.E4FD024S06
INDOOR COIL MODEL NO.F2RP/F2FP024
CONDENSER
ENTERING AIR
TEMPERATURE
75
85
95
105
115
125
ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature.
Air HandlerCoil
N1AHB08 G2FD024(S,H)171.021.021.00
N1AHB08 G2FD030(S,H)171.041.041.00
N1AHB08 G2FD035(S,H)141.041.041.00
N1VSB12 G2FD024(S,H)171.041.040.91
N1VSB12 G2FD030(S,H)171.061.060.95
F2RP/F2FP0301.031.021.05
G2FD024(S,H)141.021.051.00
G2FD024(S,H)171.021.051.00
G1HD0241.021.021.00
G1UA030S141.021.021.00
G1UA036S171.041.041.00
G1UA036S211.041.041.00
G2FD030(S,H)171.041.041.00
G2FD035(S,H)141.041.041.00
G1FA030S141.021.021.00
G1FA036S171.041.041.00
G1FA036S211.041.041.00
T.C.S.C.KW
Unitary Products Group11
Page 12
036-21030-003 Rev. B (0203)
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.E4FD030S06
INDOOR COIL MODEL NO.F2RP/F2FP030
CONDENSER
ENTERING AIR
TEMPERATURE
75
85
95
105
115
125
ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature.
Air HandlerCoil
N1AHB12 G2FD030(S,H)171.001.001.04
N1AHB12 G2FD035(S,H)141.001.001.04
N1AHB12 G2FD036(S,H)171.011.011.04
N1AHB12 G2FD036(S,H)211.011.011.04
N1VSB12 G2FD036(S,H)171.031.031.04
N1VSB12 G2FD030(S,H)171.001.001.04
F2RP/F2FP0361.011.011.04
G2FD030(S,H)171.001.001.00
G2FD035(S,H)141.001.001.04
G1UA036S171.001.001.00
G1UA036S211.001.001.00
G2FD036(S,H)211.011.011.04
G2FD036(S,H)171.011.011.04
G1HD0361.001.001.00
G1FA036S171.001.001.00
G1FA036S211.001.001.00
T.C.S.C.KW
12Unitary Products Group
Page 13
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.E4FD036S06, E4FD036S25, 46
INDOOR COIL MODEL NO.F2RP/F2FP036
CONDENSER
ENTERING AIR
TEMPERATURE
75
85
95
105
115
125
ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature.
Air HandlerCoil
N1AHB12 G2FD036(S,H)171.021.021.00
N1AHB12 G2FD036(S,H)211.021.021.00
N1AHB12 G2FD042(S,H)171.041.041.00
N1AHB12 G2FD046(S,H)171.041.041.00
N1VSB12 G2FD036(S,H)171.041.040.89
N1VSB16 G2FD036(S,H)211.041.040.89
N1VSB12 G2FD046(S,H)171.061.060.91
N1VSC16 G2FD042(S,H)211.061.060.91
F2RP/F2FP0421.021.020.97
G1UA048S171.041.041.00
G1UA048S211.041.041.00
G1HD0361.021.021.00
G2FD036(S,H)171.021.020.97
G2FD036(S,H)211.021.021.00
G2FD042(S,H)211.041.041.00
G2FD046(S,H)171.041.041.00
G1HD0361.021.020.80
G1FA048S171.041.041.00
G1FA048S211.041.041.00
T.C.S.C.KW
Unitary Products Group13
Page 14
036-21030-003 Rev. B (0203)
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.E4FD042S06
INDOOR COIL MODEL NO.F2RP/F2FP042
CONDENSER
ENTERING AIR
TEMPERATURE
75
85
95
105
115
125
ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature.
Air HandlerCoil
N1AHC16 G2FD042(S,H)211.001.001.03
N1AHC16 G2FD048(S,H)211.021.021.04
N1VSC16 G2FD048(S,H)211.041.040.97
F2FP0481.021.021.00
G2FD042(S,H)211.001.001.03
G1UA048S211.021.020.99
G1HD048S1.011.011.03
G2FD046(S,H)171.011.011.03
G1HD060S1.051.051.04
G2FD048(S,H)211.021.021.04
G2FD048(S,H)241.021.021.04
G1FA048S211.021.020.99
T.C.S.C.KW
14Unitary Products Group
Page 15
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.E4FD048S06, E4FD048S25, 46
INDOOR COIL MODEL NO.F2FP048
CONDENSER
ENTERING AIR
TEMPERATURE
75
85
95
105
115
125
ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature.
Air HandlerCoil
N1AHC16 G2FD048(S,H)210.990.990.99
N1AHD20 G2FD048(S,H)240.990.990.99
N1AHD20 G2FD060(S,H)241.021.021.00
N1VSC16 G2FD048(S,H)211.001.000.94
N1VSD20 G2FD060(S,H)241.041.040.93
G1HD048S0.980.980.98
G2FD048(S,H)210.990.990.99
G2FD048(S,H)240.990.990.99
G1UA048S211.001.001.00
G1UA060S211.021.021.00
G1UA060S241.021.021.00
G2FD060(S,H)241.021.021.00
G1HD0601.011.010.99
G1FA048S211.001.001.00
G1FA060S211.021.021.00
G1FA060S241.021.021.00
T.C.S.C.KW
Unitary Products Group15
Page 16
036-21030-003 Rev. B (0203)
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.E4FD060S06, E4FD060S25,46
INDOOR COIL MODEL NO.F2FP060
CONDENSER
ENTERING AIR
TEMPERATURE
75
85
95
105
115
125
ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature.
Air HandlerCoil
F2FV0601.031.031.00
N1VSD20G2FD060(S,H)241.041.040.94
N1AHD2006 G2FD060(S,H)24 1.031.020.89
G1FA060S21,1.000.991.00
G1HD0600.990.990.99
G1UA060S21,1.021.021.04
G2FD060(S,H)241.031.020.99
T.C.S.C.KW
16Unitary Products Group
Page 17
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NOE4FD018S06
EVAPORATOR COIL MODEL NOF2RP/F2FP018
AIR TEMP.
ENTERING
OUTDOOR
UNIT
60
47
40
30
17
10
NOTE:
ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
AIR TEMP.
ENTERING
INDOOR
COIL
6021.11.783.5621.71.783.6621.91.654.00
7020.01.813.3320.91.833.4321.31.703.76
8018.91.843.0820.01.883.2020.51.763.50
6018.31.653.2618.51.673.2518.71.573.48
7017.11.702.9517.61.723.0017.91.613.25
8015.71.752.6416.61.772.7417.01.653.01
6014.81.323.2516.81.613.0317.51.513.36
7013.71.502.6615.81.662.7715.71.562.92
8012.72.001.8414.71.722.5013.91.892.14
6014.01.522.6714.41.532.7214.11.402.91
7012.81.562.3713.31.582.4313.41.472.63
8011.51.602.0712.11.642.1512.61.552.35
6010.61.402.2311.21.422.3211.41.352.49
70 9.4 1.481.8710.01.472.0010.31.432.12
808.21.581.538.81.531.699.21.521.77
609.01.342.049.51.372.109.91.292.32
707.61.371.688.21.411.778.71.341.97
806.21.421.337.01.471.457.61.401.65
MBTUH
600650700
K.W.C.O.P.MBTUHK.W.C.O.P.MBTUHK.W.C.O.P.
036-21030-003 Rev. B (0203)
ID CFM
Multipliers for determining the performance with other indoor sections.
Air HandlerCoil
F2RP/F2FP0241.010.981.03
G2FD024(S,H)14,171.021.001.02
G1HD0241.031.011.03
G1UA024S171.021.021.00
G1UA030S141.031.011.02
G1FA024S171.021.021.00
G1FA030S141.031.031.00
T.C.S.C.KW
Unitary Products Group17
Page 18
036-21030-003 Rev. B (0203)
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NOE4FD024S06
EVAPORATOR COIL MODEL NOF2RP/F2FP024
AIR TEMP.
ENTERING
OUTDOOR
UNIT
60
47
40
30
17
10
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
AIR TEMP.
ENTERING
INDOOR
COIL
6027.22.213.7227.42.173.8027.01.974.12
7026.12.273.4626.72.253.5826.52.043.90
8025.02.483.0325.92.473.1626.02.263.47
6023.22.013.3923.22.053.3223.71.903.66
7022.02.073.1322.42.123.1023.21.983.44
8020.82.232.7421.62.302.7622.62.153.08
6018.41.633.2721.01.993.0621.81.873.39
7017.41.862.7320.12.052.8419.91.933.00
8016.52.561.8819.22.202.5418.12.422.18
6017.21.892.6317.71.912.6817.31.752.86
7016.11.932.4116.81.962.4816.91.822.67
8015.02.022.1515.92.062.2216.41.952.44
6013.01.732.2013.51.802.2014.01.672.45
7012.01.752.0112.51.832.0013.11.702.25
8010.91.761.8211.51.861.8112.21.722.07
6010.81.721.8911.21.751.9311.71.642.14
70 9.5 1.721.6710.21.761.7410.41.671.88
808.21.671.489.11.731.599.11.651.67
MBTUHK.W.C.O.P.MBTUHK.W.C.O.P.MBTUHK.W.C.O.P.
750800850
ID CFM
Multipliers for determining the performance with other indoor sections.
Air HandlerCoil
F2RP/F2FP0301.020.991.03
G2FD035(S,H)141.001.001.00
G2FD030(S,H)171.011.011.00
G2FD024(S,H)14,171.001.001.00
G1HD0240.981.010.97
G1UA030S140.981.040.95
G1UA036S17,211.001.030.97
G1FA030S140.981.040.95
G1FA036S17,211.001.030.97
T.C.S.C.KW
18Unitary Products Group
Page 19
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NOE4FD030S06
EVAPORATOR COIL MODEL NOF2RP/F2FP030
AIR TEMP.
ENTERING
OUTDOOR
UNIT
60
47
40
30
17
10
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
AIR TEMP.
ENTERING
INDOOR
COIL
6034.52.763.7734.82.753.8234.92.733.86
7033.02.863.4734.22.873.5934.72.883.64
8031.72.943.2433.82.973.4334.63.003.49
6029.62.553.4129.92.553.4430.12.553.46
7028.02.643.1129.02.663.2029.52.683.23
8026.52.722.8628.22.753.0129.02.783.06
6026.82.413.2227.62.463.2727.82.483.26
7025.32.512.9326.22.552.9926.52.572.99
8023.92.622.6524.82.642.7325.22.672.74
6023.22.302.9124.12.322.9924.52.353.00
7021.22.352.6122.22.382.6922.82.422.71
8019.22.422.2920.32.472.3821.02.522.41
6018.22.072.5818.52.112.5718.82.172.54
7016.52.132.2717.02.172.3017.42.222.30
8014.72.191.9815.52.232.0416.02.272.07
6015.01.982.2915.82.022.3716.42.082.39
7013.62.012.0414.22.062.0914.82.112.12
8012.12.051.7912.52.091.8213.22.141.86
MBTUHK.W.C.O.P.MBTUHK.W.C.O.P.MBTUHK.W.C.O.P.
100010501100
036-21030-003 Rev. B (0203)
ID CFM
Multipliers for determining the performance with other indoor sections.
Air HandlerCoil
F2RP/F2FP0360.980.981.00
G2FD035(S,H)141.011.011.00
G1FD030S171.011.011.00
G1FD036S17,211.011.011.00
G1HD0361.020.971.05
G1UA036S17,211.011.011.00
G1FA036S17,211.011.011.00
T.C.S.C.KW
Unitary Products Group19
Page 20
036-21030-003 Rev. B (0203)
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NOE4FD036S06, E4FD036S25, 46
EVAPORATOR COIL MODEL NOF2RP/F2FP036
AIR TEMP.
ENTERING
OUTDOOR
UNIT
60
47
40
30
17
10
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
AIR TEMP.
ENTERING
INDOOR
COIL
6042.83.343.8543.23.283.9742.53.253.94
7040.33.523.4541.43.473.5941.43.463.60
8038.53.683.1640.23.653.3240.93.663.37
6036.63.093.4837.03.073.5436.13.063.46
7034.43.233.1235.23.233.2035.13.233.18
8032.63.362.8533.93.382.9534.53.402.98
6032.72.973.2033.72.983.2934.52.993.35
7031.03.092.9231.93.102.9932.83.123.06
8029.33.222.6530.23.242.7131.23.262.78
6027.52.802.8428.92.842.9429.02.862.92
7025.82.872.6027.22.922.6927.52.942.70
8023.62.972.3025.13.032.3925.63.062.42
6022.02.552.5322.52.602.5422.62.632.52
7020.32.622.2721.02.682.3021.32.712.30
8018.52.682.0319.42.752.0819.82.782.10
6018.42.442.2819.22.502.3119.52.542.31
7016.72.482.0317.72.552.0918.02.592.10
8015.02.511.8016.12.591.8816.52.621.89
MBTUHK.W.C.O.P.MBTUHK.W.C.O.P.MBTUHK.W.C.O.P.
110012001300
ID CFM
Multipliers for determining the performance with other indoor sections.
Air HandlerCoil
F2RP/F2FP0421.001.001.00
G2FD036(S,H)171.001.001.00
G2FD036(S,H)211.001.001.00
G2FD042(S,H)210.990.991.00
G2FD046(S,H)170.990.991.00
G1HD0361.031.011.02
G1UA048S210.990.991.00
G1FA048S210.990.991.00
T.C.S.C.KW
20Unitary Products Group
Page 21
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NOE4FD042S06
EVAPORATOR COIL MODEL NOF2RP/F2FP042
AIR TEMP.
ENTERING
OUTDOOR
UNIT
60
47
40
30
17
10
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
AIR TEMP.
ENTERING
INDOOR
COIL
6049.83.584.0848.63.484.0947.93.484.04
7047.83.893.6146.83.783.6346.13.733.63
8047.64.333.2246.64.193.2645.94.073.30
6041.33.413.5641.03.353.5940.23.333.54
7039.83.683.1739.53.623.2039.13.603.19
8039.54.082.8439.34.012.8838.93.932.90
6037.93.273.4037.23.233.3737.13.223.38
7036.03.562.9735.63.512.9735.63.492.99
8035.23.912.6434.93.852.6635.13.822.69
6031.63.073.0231.63.053.0431.63.053.04
7030.33.382.6329.93.332.6330.23.332.66
8029.63.672.3728.83.602.3529.53.592.41
6023.22.812.4223.52.822.4423.72.832.46
7022.23.012.1622.63.012.2022.83.022.21
8021.13.231.9221.73.221.9821.93.231.98
6019.22.592.1719.42.612.1819.72.652.18
7018.22.761.9318.72.781.9718.92.811.97
8016.82.891.7117.62.921.7717.72.941.77
MBTUHK.W.C.O.P.MBTUHK.W.C.O.P.MBTUHK.W.C.O.P.
140015001600
036-21030-003 Rev. B (0203)
ID CFM
Multipliers for determining the performance with other indoor sections.
Air HandlerCoil
F2FP0481.020.991.03
G2FD042(S,H)210.990.981.01
G2FD046(S,H)170.990.961.03
G2FD048(S,H)21,1.000.941.06
G1HD0481.000.961.04
G1HD0601.000.951.05
G1UA048S211.000.941.06
G1FA048S211.000.941.06
T.C.S.C.KW
Unitary Products Group21
Page 22
036-21030-003 Rev. B (0203)
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NOE4FD048S06, E4FD048S25, 46
EVAPORATOR COIL MODEL NOF2FP048
AIR TEMP.
ENTERING
OUTDOOR
UNIT
60
47
40
30
17
10
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
AIR TEMP.
ENTERING
INDOOR
COIL
6055.43.904.1757.64.024.2056.73.834.34
7055.34.473.6355.24.343.7354.83.904.13
8055.25.243.0952.84.683.3152.74.203.68
6047.04.253.2447.13.703.7348.93.743.83
7046.94.273.2347.04.183.3047.23.803.64
8046.34.892.7746.94.802.8745.44.103.25
6037.33.273.3542.63.993.1343.03.643.47
7037.03.682.9442.64.073.0742.23.823.24
8036.25.361.9842.14.622.6739.75.062.30
6035.83.692.8536.83.722.9037.73.573.10
7034.83.832.6636.23.892.7336.43.622.95
8033.54.242.3235.54.332.4035.03.902.63
6028.73.302.5529.23.302.5929.43.052.83
7027.53.572.2528.03.572.3028.43.292.53
8026.23.871.9926.83.862.0427.33.552.26
6024.63.042.3825.03.042.4125.42.812.66
7023.23.342.0323.63.342.0723.93.082.28
8021.83.541.8122.23.531.8522.63.262.03
MBTUHK.W.C.O.P.MBTUHK.W.C.O.P.MBTUHK.W.C.O.P.
145016001750
ID CFM
Multipliers for determining the performance with other indoor sections.
Coil
G2FD048(S,H)21,21.000.941.06
G2FD060(S,H)241.000.951.05
G1HD0481.000.951.05
G1HD0601.000.951.05
G1UA060S241.000.951.05
G1FA048S211.000.961.04
G1FA060S241.000.951.05
G1UA048S211.000.961.04
T.C.S.C.KW
22Unitary Products Group
Page 23
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NOE4FD060S06, E4FD060S25, 46
EVAPORATOR COIL MODEL NOF2FP060
AIR TEMP.
ENTERING
OUTDOOR
UNIT
60
47
40
30
17
10
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
AIR TEMP.
ENTERING
INDOOR
COIL
6070.05.583.7368.15.393.7566.15.233.75
7071.75.823.6670.35.613.7268.75.443.75
8071.66.793.1370.76.513.2369.76.313.28
6060.35.333.3259.95.193.3857.75.113.31
7060.85.563.2161.05.423.3059.35.343.26
8060.36.352.7861.06.182.8959.76.082.88
6055.44.983.2456.05.013.2753.84.953.17
7056.05.373.0456.05.323.0755.55.293.06
8055.76.002.7155.15.862.7556.45.842.82
6049.74.833.0050.14.783.0549.84.733.07
7048.45.242.6948.95.182.7549.05.142.77
8046.65.552.4447.25.472.5147.65.452.54
6039.74.712.4740.94.762.5238.74.752.39
7038.54.982.2739.74.992.3337.74.992.22
8037.35.352.0438.45.312.1236.85.312.03
6035.14.652.2436.54.672.3236.84.652.35
7033.54.882.0434.74.892.1035.14.892.13
8032.15.061.8833.15.071.9433.65.081.97
MBTUHK.W.C.O.P.MBTUHK.W.C.O.P.MBTUHK.W.C.O.P.
175018001850
036-21030-003 Rev. B (0203)
ID CFM
Multipliers for determining the performance with other indoor sections.
Air HandlerCoil
F2FV0600.980.981.00
GFD060(S,H)240.980.951.03
G1HD0600.981.050.94
G1UA060S21,241.010.981.03
G1FA060S21,241.010.981.03
T.C.S.C.KW
Unitary Products Group23
Page 24
MATCHING INDOOR COMPONENTS
ADD-ON COILS - FOR FURNACE APPLICATIONS
G1UA
1/2 CASED
UPFLOW
G1FA
FULL CASED
UPFLOW
* Available with factory installed horizontal drain pan.
G1HD
HORIZONTAL DUCT
AIR HANDLERS - FOR NON-FURNACE APPLICATIONS
N1AH OR N1VS
MODULAR BLOWER
(UPFLOW, HORIZONTAL
AND DOWNFLOW)
G1NA
UNCASED
UPFLOW
G2FD*
MULTI-POSITION
(UPFLOW, HORIZONTAL
AND DOWNFLOW)