Yokogawa EJX438B User Manual

User’s Manual
EJX118B and EJX438B Diaphragm Sealed Differential Pressure and Pressure Transmitters
IM 01C27H01-01EN
Yokogawa Electric Corporation
8th Edition
EJX118B and EJX438B Diaphragm Sealed Differential Pressure and Pressure Transmitters
IM 01C27H01-01EN 8th Edition

Contents

1. Introduction ............................................................................................... 1-1
1.1 Safe Use of This Product .................................................................................1-2
1.2 Radio Wave ........................................................................................................1-3
1.3 Warranty .............................................................................................................1-3
1.4 Trademarks ........................................................................................................1-3
1.5 ATEX Documentation .......................................................................................1-4
2. Handling Cautions .................................................................................... 2-1
2.1 Model and Specications Check .....................................................................2-1
2.2 Unpacking ..........................................................................................................2-1
2.3 Storage ...............................................................................................................2-1
2.4 Selecting the Installation Location ................................................................ 2-2
2.5 Pressure Connection ........................................................................................ 2-2
2.6 Restrictions on Use of Radio Transceivers ...................................................2-3
2.7 Insulation Resistance and Dielectric Strength Test ......................................2-3
2.8 Installation of an Explosion-Protected Instrument .......................................2-4
2.8.1 FM Approval .......................................................................................2-4
2.8.2 CSA Certication ................................................................................2-5
2.8.3 ATEX Certication ..............................................................................2-5
2.8.4 IECEx Certication .............................................................................2-7
2.9 EMC Conformity Standards .............................................................................2-7
2.10 Pressure Equipment Directive (PED) .............................................................2-7
2.11 Low Voltage Directive .......................................................................................2-8
2.12 Regulatory Compliance for Radio and Telecommunication ........................2-8
2.12.1 Radio and Telecommunications Terminal Equipment Directive (R&TTE)
....................................................................................................2-8
2.12.2 FCC compliance ................................................................................2-8
2.12.3 Industry Canada (IC) compliance ......................................................2-9
i
3. Component Names .................................................................................. 3-1
8th Edition: Jan. 2014 (YK) All Rights Reserved, Copyright © 2010, Yokogawa Electric Corporation
IM 01C27H01-01EN
4. Installation ................................................................................................. 4-1
4.1 Precautions .......................................................................................................4-1
4.2 Mounting the Diaphragm Seals .......................................................................4-1
4.3 Transmitter Mounting ....................................................................................... 4-2
4.4 Mounting the Flushing Connection Ring ....................................................... 4-4
4.4.1 Mounting to Pressure Detector Section .............................................4-4
4.4.2 Mounting to Process Flange ..............................................................4-4
4.5 Afxing the Teon Film ....................................................................................4-5
4.6 Rotating Transmitter Section ...........................................................................4-5
4.7 Changing the Direction of Integral Indicator ................................................. 4-6
4.8 Changing the direction of the antenna ...........................................................4-6
5. Wiring ......................................................................................................... 5-1
5.1 Mounting Antenna and Wiring .........................................................................5-1
5.1.1 Mounting the antenna ........................................................................5-1
5.1.2 Mounting External Antenna and Wiring Antenna Extension Cable ...5-2
5.1.2.1 Mounting of External Antenna ............................................................5-2
5.1.2.2 Wiring of Antenna Extension Cable ...................................................5-2
5.1.2.3 Mounting of Arrester and Wiring ........................................................5-4
5.2 Grounding ..........................................................................................................5-4
ii
6. Operation ................................................................................................... 6-1
6.1 Preparation for Starting Operation ................................................................. 6-1
6.2 Zero Point Adjustment ..................................................................................... 6-2
6.3 Starting Operation ............................................................................................ 6-3
6.4 Connecting to the Field Wireless Network ..................................................... 6-3
6.5 Shutting Down The Transmitter ......................................................................6-5
6.6 Venting or Draining Transmitter Process-Detector Section ........................6-5
6.6.1 Draining Condensate for Flushing Connection Ring .........................6-6
6.6.2 Venting Gas for Flushing Connection Ring ........................................6-6
7. Setting Parameters ................................................................................... 7-1
7.1 Environment for parameter setting .................................................................7-1
7.2 Preparing Software ...........................................................................................7-1
7.2.1 Softwares for the Field Wireless Conguration Tool and the Device
Conguration Tool ..............................................................................7-1
7.2.2 Software Download ............................................................................7-1
7.3 Setting Parameters ...........................................................................................7-1
7.3.1 Parameter Usage and Selection ........................................................7-1
7.3.2 Function Block and Menu Tree ..........................................................7-3
7.3.3 Parameters for Wireless Communication ........................................7-17
7.3.4 Tag and Device Information .............................................................7-18
7.3.5 Unit ...................................................................................................7-18
7.3.6 Range Change .................................................................................7-18
7.3.7 Output Mode ....................................................................................7-18
IM 01C27H01-01EN
7.3.8 Output Signal Low Cut Mode Setup ................................................7-19
7.3.9 Impulse Line Connection Orientation Setup ....................................7-19
7.3.10 Integral Indicator Display Mode .......................................................7-19
7.3.11 Integral Indicator Scale Setup ..........................................................7-20
7.3.12 Unit for Displayed Temperature .......................................................7-20
7.3.13 Unit for Displayed Static Pressure ...................................................7-20
7.3.14 Zero Point Adjustment and Span Adjustment ..................................7-21
7.3.15 Software Write Protect .....................................................................7-23
7.3.16 Switching to Deep Sleep Mode ........................................................7-23
7.3.17 Switching to Silence Mode ...............................................................7-23
7.4 Self-Diagnostics ..............................................................................................7-24
7.4.1 Identify Problems by Using the Device Conguration Tool ..............7-24
7.4.2 Alert Report ......................................................................................7-25
7.4.3 Checking with Integral Indicator .......................................................7-27
8. Maintenance .............................................................................................. 8-1
8.1 Overview ............................................................................................................ 8-1
8.2 Calibration Instruments Selection .................................................................. 8-1
8.3 Calibration .........................................................................................................8-1
8.4 Disassembly and Reassembly ........................................................................8-3
8.4.1 Replacing the Integral Indicator .........................................................8-3
8.4.2 Replacing the RF Assembly ...............................................................8-4
8.4.3 Replacing the CPU Assembly ............................................................8-4
8.4.4 Replacing the Battery Pack ...............................................................8-5
8.4.5 Replacing the Batteries ......................................................................8-5
8.4.6 Handling Batteries ..............................................................................8-6
8.5 Troubleshooting ................................................................................................8-7
8.5.1 Basic Troubleshooting .......................................................................8-7
8.5.2 Troubleshooting Flowcharts ...............................................................8-8
8.5.3 Errors and Countermeasures ..........................................................8-10
iii
9. Parameter Summary ................................................................................ 9-1
10. General Specications .......................................................................... 10-1
10.1 Standard Specications .................................................................................10-1
10.2 Model and Sufx Codes .................................................................................10-5
10.3 Optional Specications ...............................................................................10-11
10.4 Dimensions ...................................................................................................10-14
Revision Information ...............................................................................................i
IM 01C27H01-01EN
<1. Introduction>

1. Introduction

1-1
Thank you for purchasing the DPharp EJX Differential Pressure and pressure transmitter.
Your EJX Pressure Transmitter was precisely calibrated at the factory before shipment. To ensure both safety and efciency, please read this manual carefully before you operate the instrument.
NOTE
This manual covers the EJX118B and EJX438B diaphragm sealed differential pressure and pressure transmitter and describes how to use for not only the integral antenna type transmitters but also the detachable antenna ones. Unless otherwise stated, the illustrations in this manual are of the EJX118B diaphragm sealed differential pressure with an integral antenna type. Users of the other models and specications should bear in mind that certain features of their instrument will differ from those shown in the illustrations of the EJX118B.
Model
EJX118B EJX438B
• Please note that changes in the specications, construction, or component parts of the instrument may not immediately be reected in this manual at the time of change, provided that postponement of revisions will not cause difculty to the user from a functional or performance standpoint.
• Yokogawa assumes no responsibilities for this product except as stated in the warranty.
• If the customer or any third party is harmed by the use of this product, Yokogawa assumes no responsibility for any such harm owing to any defects in the product which were not predictable, or for any indirect damages.
• The following safety symbols are used in this manual and on the product:
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
Regarding This Manual
• This manual should be provided to the end user.
• The contents of this manual are subject to change without prior notice.
• All rights reserved. No part of this manual may be reproduced in any form without Yokogawa’s written permission.
• Yokogawa makes no warranty of any kind with regard to this manual, including, but not limited to, implied warranty of merchantability and tness for a particular purpose.
• If any question arises or errors are found, or if any information is missing from this manual, please inform the nearest Yokogawa sales ofce.
• The specications covered by this manual are limited to those for the standard type under the specied model number break-down and do not cover custom-made instruments.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or physical damage. It may also be used to alert against unsafe practices.
IMPORTANT
Indicates that operating the hardware or software in this manner may damage it or lead to system failure.
NOTE
Draws attention to information essential for understanding the operation and features.
IM 01C27H01-01EN
<1. Introduction>
1-2
Functional grounding terminal
Caution This symbol indicates that the operator must refer to an explanation in the user’s manual in order to avoid the risk of injury or death of personnel or damage to the instrument.

1.1 Safe Use of This Product

For the safety of the operator and to protect the instrument and the system, please be sure to follow this manual’s safety instructions when handling this instrument. If these instructions are not heeded, the protection provided by this instrument may be impaired. In this case, Yokogawa cannot guarantee that the instrument can be safely operated. Please pay special attention to the following points:
(a) Installation
• This instrument may only be installed by an engineer or technician who has an expert knowledge of this device. Operators are not allowed to carry out installation unless they meet this condition.
• With high process temperatures, care must be taken not to burn yourself by touching the instrument or its casing.
• Never loosen the process connector nuts when the instrument is installed in a process. This can lead to a sudden, explosive release of process uids.
• When draining condensate from the pressure detector section, take appropriate precautions to prevent the inhalation of harmful vapors and the contact of toxic process uids with the skin or eyes.
(b) Wiring
• The instrument must be installed by an engineer or technician who has an expert knowledge of this instrument. Operators are not permitted to carry out wiring unless they meet this condition.
(c) Maintenance
• Please carry out only the maintenance procedures described in this manual. If you require further assistance, please contact the nearest Yokogawa ofce.
• Care should be taken to prevent the build up of dust or other materials on the display glass and the name plate. To clean these surfaces, use a soft, dry cloth.
(d) Explosion Protected Type Instrument
• Users of explosion proof instruments should refer rst to section 2.8 (Installation of an Explosion Protected Instrument) of this manual.
• The use of this instrument is restricted to those who have received appropriate training in the device.
• Take care not to create sparks when accessing the instrument or peripheral devices in a hazardous location.
• Repair or modication to this instrument by customer will cause malfunction of explosion protect function and hazardous situation. If you need to repair or modication, please contact the nearest Yokogawa ofce.
(e) Modication
• Yokogawa will not be liable for malfunctions or damage resulting from any modication made to this instrument by the customer.
• When removing the instrument from a hazardous process, avoid contact with the uid and the interior of the meter.
• All installation shall comply with local installation requirements and the local electrical code.
IM 01C27H01-01EN
<1. Introduction>
1-3

1.2 Radio Wave

IMPORTANT
- This instrument is equipped with a wireless
module which is designated as a certication of construction type as a wireless facility for 2.4 GHz band low-power data communication system of the Radio Act. Refer to 2.12 “Regulatory Compliance for Radio and Telecommunication” for detail.
- Due to the designated certication of
construction type, users may be subject to legal punishment in case of:
- Disassembling or modifying the wireless module or antenna in this instrument
- Peeling off the certication label attached to the wireless module in this instrument
- Preventing interference with other wireless stations
The operating frequency bandwidth of this
instrument may overlap the same range as industrial devices, scientic devices, medical devices, microwave ovens, licensed premises radio stations and non-licensed specied low-power radio stations for mobile object identication systems used in factory production lines.
Before using this instrument, ensure that
neither a premises radio station nor specied low power radio station for mobile object identication systems is in use nearby.
If this instrument causes radio wave
interference to a wireless station for mobile object identication systems, promptly change the frequency being used or turn off the source of radio wave emissions. Then, contact a Yokogawa ofce regarding countermeasures to prevent interference, such as setting up partitions.
• If any problems are experienced with this instrument, the customer should contact the Yokogawa representative from which this instrument was purchased or the nearest Yokogawa ofce.
• If a problem arises with this instrument, please inform us of the nature of the problem and the circumstances under which it developed, including the model specication and serial number. Any diagrams, data and other information you can include in your communication will also be helpful.
• The party responsible for the cost of xing the problem shall be determined by Yokogawa following an investigation conducted by Yokogawa.
• The purchaser shall bear the responsibility for repair costs, even during the warranty period, if the malfunction is due to:
- Improper and/or inadequate maintenance by
the purchaser.
- Malfunction or damage due to a failure
to handle, use, or store the instrument in accordance with the design specications.
- Use of the product in question in a location
not conforming to the standards specied by Yokogawa, or due to improper maintenance of the installation location.
- Failure or damage due to modication or
repair by any party except Yokogawa or an approved representative of Yokogawa.
- Malfunction or damage from improper
relocation of the product in question after delivery.
- Reason of force majeure such as res,
earthquakes, storms/oods, thunder/ lightening, or other natural disasters, or disturbances, riots, warfare, or radioactive contamination.

1.3 Warranty

• The warranty shall cover the period noted on the quotation presented to the purchaser at the time of purchase. Problems occurring during the warranty period shall basically be repaired free of charge.

1.4 Trademarks

In this document, trademarks or registered trademarks are not marked with “™” or “®”. Product names and company names in this document are trademarks or registered trademarks of the respective companies
IM 01C27H01-01EN
<1. Introduction>

1.5 ATEX Documentation

This is only applicable to the countries in European Union.
1-4
GB
DK
E
NL
SK
CZ
I
LT
LV
EST
PL
SF
P
F
D
S
SLO
H
BG
RO
M
GR
IM 01C27H01-01EN
<2. Handling Cautions>
The antenna is a detachable
Antenna

2. Handling Cautions

2-1
This chapter provides important information on how to handle the transmitter. Read this carefully before using the transmitter.
EJX Series transmitters are thoroughly tested at the factory before shipment. When taking delivery of an instrument, visually check them to make sure that no damage occurred during shipment.
Also check that all transmitter mounting hardware shown in gure 2.1 is included. If the transmitter is ordered without the mounting bracket and the process connector, the transmitter mounting hardware will not be included. After checking the transmitter, carefully repack it in its box and keep it there until you are ready to install it.
type when Amplifier housing code 8 is selected, and no antenna is provided for Amplifier housing code 9.
Spacer
Transmitter mounting bolt
U-bolt

2.2 Unpacking

Keep the transmitter in its original packaging to prevent it from being damaged during shipment. Do not unpack the transmitter until it reaches the installation site.

2.3 Storage

The following precautions must be observed when storing the instrument, especially for a long period.
(a) Select a storage area which meets the following
conditions:
• It is not exposed to rain or subject to water seepage/leaks.
• Vibration and shock are kept to a minimum.
• It has an ambient temperature and relative humidity within the following ranges.
Ambient temperature: –40 to 85°C –30 to 80°C LCD visible range Relative humidity: 0% to 100% R.H. Preferred temperature and humidity: approx. 25°C and 65% R.H.
U-bolt nut
Figure 2.1 Transmitter Mounting Hardware
Mounting bracket (Flat type)
2.1 Model and Specications Check
The model name and specications are written on the name plate attached to the case.
CAL
MODEL SUFFIX
SUPPLY OUTPUT MWP
Figure 2.2 Name Plate
STYLE
mA DC
RNG
V DC
NO.
Made in Japan TOKYO 180-8750 JAPAN
: Refer to USER'S MANUAL.
F0202.ai
F0201.ai
(b) When storing the transmitter, repack it carefully in
the packaging that it was originally shipped with.
(c) If the transmitter has been used, thoroughly
clean the chambers inside the cover anges, so that there is no process uid remaining inside. Before placing it in storage, also make sure that the pressure-detector is securely connected to the transmitter section.
(d) Preferably remove the batteries for storage. For
maximum battery life, the storage temperature should not exceed 30°C.
NOTE
When storing the instrument with a battery pack, it is recommended to put the instrument in Deep Sleep mode to conserve the batteries. For details on how to switch to Deep Sleep mode, refer to subsection 8.3.16 “Switching to Deep Sleep Mode”.
IM 01C27H01-01EN
<2. Handling Cautions>
1.5m or more
2-2

2.4 Selecting the Installation Location

The transmitter is designed to withstand severe environmental conditions. However, to ensure that it will provide years of stable and accurate performance, take the following precautions when selecting the installation location.
(a) Wireless Communication
NOTE
The installation location of this transmitter must meet the following conditions:
- Adjust the direction of the antenna to be in the upright position regardless of the orientation of this transmitter. See section 4 for adjusting the antenna.
- Install the transmitter at least 1.5m above the ground or oor.
(b) Ambient Temperature
Avoid locations subject to wide temperature variations or a signicant temperature gradient. If the location is exposed to radiant heat from plant equipment, provide adequate thermal insulation and/or ventilation.
(c) Ambient Atmosphere
Do not install the transmitter in a corrosive atmosphere. If this cannot be avoided, there must be adequate ventilation.
(d) Shock and Vibration
Although the transmitter is designed to be relatively resistant to shock and vibration, an installation site should be selected where this is kept to a minimum.
(e) Installation of Explosion-protected Transmitters
An explosion-protected transmitters is certied for installation in a hazardous area containing specic gas types. See subsection
2.8 “Installation of an Explosion-Protected Transmitters.”
F0203.ai
- Ensure that there are no obstacles such as walls or pipes within a 30-cm radius of each antenna.
- Conrm that each eld wireless equipment compliant with ISA100.11a can see the antenna of other devices which locate within its own communication range. In the star topology network, the visibility to the antenna of gateway is a mandatory clause.

2.5 Pressure Connection

WARNING
• Never loosen the process ange bolts when an instrument is installed in a process. The device is under pressure, and a loss of seal can result in a sudden and uncontrolled release of process uid.
• Since the accumulated process uid may be toxic or otherwise harmful, take appropriate steps to prevent the contact of such uids with the skin or eyes and the inhalation of vapors from these uids even after dismounting the instrument from process line for maintenance.
The following precautions must be observed in order to safely operate the transmitter under pressure.
(a) Make sure that there are no leaks in the impulse
piping.
(b) Never apply a pressure higher than the
specied maximum working pressure.
IM 01C27H01-01EN
<2. Handling Cautions>
2-3

2.6 Restrictions on Use of Radio Transceivers

IMPORTANT
Although the transmitter has been designed to resist high frequency electrical noise, if a radio transceiver is used near the transmitter or its external wiring, the transmitter may be affected by high frequency noise pickup. To test this, start out from a distance of several meters and slowly approach the transmitter with the transceiver while observing the measurement loop for noise effects. Thereafter use the transceiver outside the range where the noise effects were rst observed.

2.7 Insulation Resistance and Dielectric Strength Test

Since the transmitter has undergone insulation resistance and dielectric strength tests at the factory before shipment, normally these tests are not required. If the need arises to conduct these tests, heed the following:
(a) Do not perform such tests more frequently than
is absolutely necessary. Even test voltages that do not cause visible damage to the insulation may degrade the insulation and reduce safety margins.
(b) Never apply a voltage exceeding 500 V DC
(100 V DC with an internal lightning protector) for the insulation resistance test, nor a voltage exceeding 500 V AC (100 V AC with an internal lightning protector) for the dielectric strength test.
(c) The procedure for conducting these tests is as
follows:
• Insulation Resistance Test
4) Turn ON the insulation tester power and measure the insulation resistance. The voltage should be applied as briey as possible to verify that the insulation resistance is at least 20 MΩ.
5) After completing the test and being very careful not to touch exposed conductors disconnect the insulation tester and connect a 100 kΩ resistor between the grounding terminal and the short­circuiting battery connection terminals. Leave this resistor connected at least one second to discharge any static potential. Do not touch the terminals while it is discharging.
NOTE
When storing the instrument with a battery pack, it is recommended to put the instrument in Deep Sleep mode to conserve the batteries. For details on how to switch to Deep Sleep mode, refer to subsection 7.3.16 “Switching to Deep Sleep Mode”.
• Dielectric Strength Test
1) Remove the battery pack. See subsection 9.4.6 for details on how to remove it.
2) Short-circuit the battery connection terminals in the terminal box.
3) Turn OFF the dielectric strength tester. Then connect the tester between the shorted battery connection terminals and the grounding terminal. Be sure to connect the grounding lead of the dielectric strength tester to the ground terminal.
4) Set the current limit on the dielectric strength tester to 0.1 mA, then turn ON the power and gradually increase the test voltage from ‘0’ to the specied voltage.
5) When the specied voltage is reached, hold it for one minute.
6) After completing this test, slowly decrease the voltage to avoid any voltage surges.
1) Remove the battery pack. See subsection 9.4.6 for details on how to remove it.
2) Short-circuit the battery connection terminals in the terminal box.
3) Turn OFF the insulation tester. Then connect the insulation tester plus (+) lead wire to the shorted battery connection terminals and the minus (–) leadwire to the grounding terminal.
NOTE
When storing the instrument with a battery pack, it is recommended to put the instrument in Deep Sleep mode to conserve the batteries. For details on how to switch to Deep Sleep mode, refer to subsection 7.3.16 “Switching to Deep Sleep Mode”.
IM 01C27H01-01EN
<2. Handling Cautions>
[Installation Diagram]
2-4
2.8 Installation of an Explosion­Protected Instrument
If a customer makes a repair or modication to an intrinsically safe instrument and the instrument is not restored to its original condition, its intrinsically safe construction may be compromised and the instrument may be hazardous to operate. Please contact Yokogawa before making any repair or modication to an instrument.
CAUTION
This instrument has been tested and certied as being intrinsically safe. Please note that severe restrictions apply to this instrument’s construction, installation, external wiring, maintenance and repair. A failure to abide by these restrictions could make the instrument a hazard to operate.
WARNING
The battery pack may be replaced in a hazardous area. The battery pack has surface resistivity greater than 1G ohm and must be properly installed in the enclosure of the transmitter. Care must be taken during transportation to and from the point of installation to prevent electrostatic charge build-up.
• Temperature Class: T4
• Ambient temperature: -50 to 70°C
Note 2. Installation
• Installation should be in accordance with ANSI/ISA-RP12.06.01 and the National Electric Code (NFPA 70).
• Dust-tight conduit seal must be used when installed in a Class II, III, Group E, F and G environments.
• Note a warning label worded “SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY,” and “INSTALL IN ACCORDANCE WITH DOC. NO. IFM037-A20”.
Amplifier housing code 7
Hazardous Location
Transmitter
Battery Pack
[Intrinsically Safe] Class I, II, III, Division 1, Groups A,B,C,D,E,F,G Class I, Zone 0 in Hazardous (Classified) Locations AEx ia IIC
Amplifier housing codes other than 7
Hazardous Location
Arrester
(*1, *2)
Antenna Connector
[Nonincendive] Class I, II, Division 2, Groups A,B,C,D,F,G Class III, Division 1. Class I, Zone 2, Group IIC, in Hazardous (Classified) Locations
Antenna
(*1)

2.8.1 FM Approval

Caution for FM intrinsically safe type. (Following contents refer “DOC. No. IFM037-A20”)
Note 1. Model EJX Series Differential, gauge
and absolute pressure transmitters with optional code /FS17 are applicable for use in hazardous locations.
• Applicable Standard: Class 3600, Class 3610, Class 3611, Class 3810, NEMA 250, ANSI/ISA-60079-0, ANSI/ISA-60079-11
• Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1, Groups E, F & G and Class III, Division 1, Class I, Zone 0, in Hazardous Locations, AEx ia IIC
• Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division 2, Groups F & G and Class III, Division 1, Class I, Zone 2, Groups IIC, in Hazardous Locations.
• Enclosure: NEMA 4X (Indoors and outdoors).
Transmitter
Battery Pack
*1: These apparatus are simple apparatus. *2: Arrester may not be connected.
[Intrinsically Safe] Class I, II, III, Division 1, Groups A,B,C,D,E,F,G Class I, Zone 0 in Hazardous (Classified) Locations AEx ia IIC
[Nonincendive] Class I, II, Division 2, Groups A,B,C,D,F,G Class III, Division 1. Class I, Zone 2, Group IIC, in Hazardous (Classified) Locations
Note 3. Maintenance and Repair
• The instrument modication or parts replacement by other than authorized representative of Yokogawa Electric Corporation is prohibited and will void FM Approvals approval.
Note 4. Battery Pack USE ONLY BATTERY PACK YOKOGAWA
F9915MA OR F9915NS.
F0210.ai
IM 01C27H01-01EN
<2. Handling Cautions>
2-5
Note 5. Special Conditions for safe use POTENTIAL ELECTROSTATIC CHARGING
HAZARD-SECURE DISTANCE OF 100MM FROM ANTENNA.
DO NOT OPEN WHEN CL II, III, DIV 1,2
ATMOSPHERE IS PRESENT.
2.8.2 CSA Certication
Caution for CSA Intrinsically safe type. (Following contents refer to “DOC No. ICS030”)
Note 1. Model EJX Series differential, gauge,
and absolute pressure transmitters with optional code /CS17 are applicable for use in hazardous locations
Certicate: 2325443
• Applicable standard: CAN/CSA-C22.2 No.0, CAN/CSA-C22.2 No.0.4, C22.2 No.25, CAN/CSA-C22.2 No.94, CAN/CSA-C22.2 No.157, C22.2 No.213, CAN/CSA-C22.2 No.61010-1, CAN/CSA- C22.2 No.60079-0, CAN/CSA-E60079-11, IEC60529
• Ex ia IIC T4
• Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1, Groups E, F & G, Class III, Division 1
• Nonincendive for Class I, Division2, Groups A, B, C & D, Class II, Division2, Groups F & G, Class III, Division1
• Enclosure: IP66/IP67 and Type 4X
• Temperature Code: T4
• Ambient Temperature: –50 to 70°C
• Max. Process Temp.: 120°C
[Installation Diagram]
Amplifier housing code 7
Hazardous Area
Transmitter
Battery Pack
[Intrinsically Safe] Group IIC, Zone 0 Class I, II, III, Division 1, Groups A,B,C,D,E,F,G
Amplifier housing code 8 and 9
Hazardous Area
Arrester
(*1, *2)
Antenna Connector
Transmitter
Battery Pack
*1: These apparatus are simple apparatus. *2: Arrester may not be connected.
[Intrinsically Safe] Group IIC, Zone 0 Class I, II, III, Division 1, Groups A,B,C,D,E,F,G
[Nonincendive] Class I, II, Division 2, Groups A,B,C,D,F,G Class III, Division 1
Antenna
(*1)
[Nonincendive] Class I, II, Division 2, Groups A,B,C,D,F,G Class III, Division 1
Note 3. Battery Pack
• Use only YOKOGAWA battery pack F9915MA or F9915NS .
Note 4. Special Conditions for safe use
• Potential electrostatic charging hazard ­secure distance of 100mm from antenna.
2.8.3 ATEX Certication
F0205.ai
Note 2. Installation
• Installation should be in accordance with Canadian Electrical Code Part I and Local Electrical Code.
• Do not alter drawing without authorization from CSA.
• The instrument modication or parts replacement by other than authorized representative of Yokogawa Electric Corporation is prohibited and will void Canadian Standards Intrinsically safe and nonincendive Certication.
(1) Technical Data
Caution for ATEX Intrinsically safe type.
Note 1. Model EJX Series pressure transmitters
with optional code /KS27 for potentially explosive atmospheres:
• No. KEMA 10ATEX0164 X
• Applicable Standard: EN 60079-0:2009, EN 60079-11:2012, EN 60079-26:2007
• Type of Protection and Marking code: Ex ia IIC T4 Ga
• Group: II
• Category: 1 G
• Ambient Temperature: –50°C to 70°C
• Process Temperature (Tp.): 120°C max.
• Enclosure: IP66/IP67
IM 01C27H01-01EN
<2. Handling Cautions>
2-6
Note 2. Installation
• Installation should be in accordance with local installation requirements. (Refer to the Control Drawing)
[Control Drawing]
Amplifier housing code 7
Hazardous Area
Transmitter
Battery Pack
Amplifier housing code 8 and 9
Hazardous Area
Arrester
(*1, *2)
Antenna connector
Transmitter
Battery Pack
*1: These apparatus are simple apparatus. *2: Arrester may not be connected.
Antenna
(*1)
F0206.ai
Note 3. Battery Pack
• Use only YOKOGAWA battery pack F9915MA or F9915NS.
Note 4. Special conditions for Safe Use
• In case the enclosure of the Pressure Transmitter is made of aluminum, if it is mounted in an area where the use of category 1 G apparatus is required, it must be installed such, that, even in the event of rare incidents, ignition sources due to impact and friction sparks are excluded.
• For applications in explosive atmospheres caused by gases, vapors or mists and where category 1 G apparatus is required, electrostatic charges on the non-metallic parts of the Pressure Transmitter shall be avoided.
WARNING
Potential electrostatic charging hazard - secure distance of 100mm from antenna.
(2) Operation
WARNING
Take care not to generate mechanical sparking when access to the instrument and peripheral devices in a hazardous location.
(3) Maintenance and repair
WARNING
The instrument modication or parts replacement by other than an authorized Representative of Yokogawa Electric Corporation is prohibited and will void the certication.
(4) Name Plate
• Name Plate
CAL
MODEL SUFFIX
SUPPLY OUTPUT MWP
STYLE
mA DC
RNG
V DC
NO.
Made in Japan TOKYO 180-8750 JAPAN
: Refer to USER'S MANUAL.
F0207.ai
• Tag plate for intrinsically safe type
No. KEMA 10ATEX016 4 X Ex ia IIC T4 Ga
KS27
*3
WARNIN G
ENCLOSUR E: IP66/IP67 Tamb.: -50 TO 70°C MAX PROC ESS TEMP.: 120°C
POTENTIAL ELEC TROSTATIC CHARGING HA ZARD - SECURE D ISTANCE OF 100MM FROM A NTENNA. USE ONLY BATTERY PACK YOKOGAWA F9915 MA OR F9915NS. POTENTIAL ELEC TROSTATIC CHARGING HA ZARD - SEE USER 'S MANUAL.
F0208.ai
MODEL: Specied model code. STYLE: Style code. SUFFIX: Specied sufx code. SUPPLY: Supply voltage. OUTPUT: Output signal. MWP: Maximum working pressure. CAL RNG: Specied calibration range. NO.: Serial number and year of production TOKYO 180-8750 JAPAN: The manufacturer name and the address
*1: The rst digit in the nal three numbers of the serial
number appearing after “NO.” on the nameplate indicates the year of production. The following is an example of a serial number for a product that was produced in 2010:
91K819857 032 The year 2010
*2: “180-8750” is a zip code which represents the following
address.
2-9-32 Nakacho, Musashino-shi, Tokyo Japan
*3: The identication number of Notied Body.
*1
*2
.
.
IM 01C27H01-01EN
<2. Handling Cautions>
2-7
2.8.4 IECEx Certication
Caution for IECEx Intrinsically safe type.
Note 1. Model EJX Series pressure transmitters
with optional code /SS27 for potentially explosive atmospheres:
• No. IECEx KEM 10.0074X
• Applicable Standard: IEC 60079-0: 2011, IEC 60079-11:2011, IEC 60079-26: 2006
• Type of Protection and Marking code: Ex ia IIC T4 Ga
• Ambient Temperature: –50°C to 70°C
• Process Temperature (Tp.): 120°C max.
• Enclosure: IP66/IP67
Note 2. Installation
• Installation should be in accordance with local installation requirements. (Refer to the Control Drawing)
[Control Drawing]
Amplifier housing code 7
Hazardous Area
Transmitter
Battery Pack
Amplifier housing code 8 and 9
Hazardous Area
Arrester
(*1, *2)
Antenna connector
Antenna
(*1)
Note 4. Battery Pack
• Use only YOKOGAWA battery pack F9915MA or F9915NS.
Note 5. Special conditions for Safe Use
• In case the enclosure of the Pressure Transmitter is made of aluminum, if it is mounted in an area where the use of apparatus of equipment protection level Ga is required, it must be installed such, that, even in the event of rare incidents, ignition sources due to impact and friction sparks are excluded.
• For applications in explosive atmospheres caused by gases, vapors or mists and mounted in an area where the use of apparatus of equipment protection level Ga is required, electrostatic charges on the non­metallic parts of the Pressure Transmitter shall be avoided.
WARNING
Potential electrostatic charging hazard ­secure distance of 100mm from antenna.
Take care not to generate mechanical sparking when access to the instrument and peripheral devices in a hazardous location.

2.9 EMC Conformity Standards

Transmitter
Battery Pack
*1: These apparatus are simple apparatus. *2: Arrester may not be connected.
F0209.ai
Note 3. Maintenance and Repair
• The instrument modication or parts replacement by other than authorized representative of Yokogawa Electric Corporation is prohibited and will void IECEx Intrinsically safe Certication.
WARNING
The instrument modication or parts replacement by other than an authorized Representative of Yokogawa Electric Corporation is prohibited and will void the certication.
EN61326-1 Class A, Table 2 (For use in industrial locations), EN61326-2-3
CAUTION
This instrument is a Class A product, and it is designed for use in the industrial environment. Please use this instrument in the industrial environment only.

2.10 Pressure Equipment Directive (PED)

(1) General
EJX Series pressure transmitters are
categorized as piping under the pressure accessories section of directive 97/23/EC, which corresponds to Article 3, Paragraph 3 of PED, denoted as Sound Engineering Practice (SEP).
IM 01C27H01-01EN
<2. Handling Cautions>
2-8
(2) Technical Data
Article 3, Paragraph 3 of PED, denoted as
Sound Engineering Practice (SEP).
(3) Operation
CAUTION
• The temperature and pressure of uid should be maintained at levels that are consistent with normal operating conditions.
• The ambient temperature should be maintained at a level that is consistent with normal operating conditions.
• Please take care to prevent water hammer and the like from inducing excessive pressures in pipes and valves. If phenomena are likely, install a safety valve or take some other appropriate measure to prevent pressure from exceeding PS.
• Take appropriate measures at the device or system level to protect transmitters if they are to be operated near an external heat source.

2.11 Low Voltage Directive

Applicable standard: EN61010-1, EN61010-2-030
(1) Pollution Degree 2
"Pollution degree" describes the degree to which a solid, liquid, or gas which deteriorates dielectric strength or surface resistivity is adhering. " 2 " applies to normal indoor atmosphere. Normally, only non-conductive pollution occurs. Occasionally, however, temporary conductivity caused by condensation must be expected.
(2) Installation Category I
(Anticipated transient overvoltage 330 V)
"Overvoltage category (Installation category)" describes a number which denes a transient overvoltage condition. It implies the regulation for impulse withstand voltage. " I " applies to electrical equipment which is supplied from the circuit when appropriate transient overvoltage control means (interfaces) are provided.

2.12 Regulatory Compliance for Radio and Telecommunication

Please conrm that a installation region fulls a standards, require additional regulatory information and approvals, contact to Yokogawa Electric Corporation.
2.12.1 Radio and Telecommunications
Terminal Equipment Directive (R&TTE)
We, Yokogawa Electric Corporation hereby declare that this equipment, model EJX-L series is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
The CE declaration of conformity for R&TTE for this product can be found at http://www.
yokogawa.com/d/

2.12.2 FCC compliance

This equipment contains transmitter module FCC ID: SGJ-WFC001. This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of this device.
Co-located:
This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter.
FCC WARNING:
Changes or modications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
IM 01C27H01-01EN
<2. Handling Cautions>
This radio transmitter IC Number
NOTE
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual,may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

2.12.3 Industry Canada (IC) compliance

This equipment contains transmitter module IC: 8999A-WIC001.
This Class A digital apparatus complies with Canadian ICES-003.
8999A-WIC001 has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Antenna type: Gain: COLLINEAR 9 dBi, 50 Ω Sleeve 2.14 dBi, 50 Ω
French: Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
2-9
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired, operation of the device.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante.
Le présent émetteur radio IC Number 8999A-WIC001 a été approuvé par Industrie Canada pour fonctionner avec les types d’antenne énumérés ci-dessous et ayant un gain admissible maximal et l’impédance requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur. Antenne type: Gain: COLLINEAR 9 dBi, 50 Ω Sleeve 2.14 dBi, 50 Ω
IM 01C27H01-01EN
<3. Component Names>

3. Component Names

3-1
EJX118B
Transmitter
section *
* See below for details
Cover flange
Diaphragm seal
(high pressure side)
Diaphragm seal
(low pressure side)
Pressure­detector section
Capillary tube
Figure 3.1 Component Names (External View of Flush type)
Flushing connection ring
Diaphragm seal with flushing connection ring
Drain/vent plug
Antenna (Note 3)
EJX438B
Transmitter
section *
* See below for details
Cover flange
Diaphragm seal
Pressure­detector section
F0301.ai
Ground terminal
Zero-adjustment screw
Bolt
Integral indicator
Amplifier cover
Note 1: Write Protection is set by sliding the hard write protection switch (WR) shown in gure. The hardware write protection switch is
set to the E side (Write enable) for delivery. Set an unused switch to H side.
Note 2: When the switch is D side (write protection setting), provisioning is acceptable. For details of provisioning, refer to section 7.4
“Connecting to Field Wireless Network”.
Note 3: The detachable antenna is applied when the amplier housing code 7 or 8 is specied.
Mounting screw
Slide switch
Transmitter section
CPU assembly
RF assembly
Write protection switch
Not in use
Cover flange
Hardware write protection switch (WR)
Write Protection
E WRD
Switch Position
(Note 1)
Write Protection
Pressure-detector section
ED
NO
H
(Write disabled)
L
L
(Write enabled)
YES
ED
H
(Note 2)
F0302.ai
Figure 3.2 Component Names (Details of Transmitter section)
Table 3.1 Display Symbol
Display Symbol Meaning of Display Symbol
Display mode is ‘square root’. (Display is not lit when ‘linear’ mode.) ▲ The output signal being zero-adjusted is increasing. ▼ The output signal being zero-adjusted is decreasing.
Write protect function is enabled.
IM 01C27H01-01EN
<4. Installation>
Flange

4. Installation

4-1

4.1 Precautions

Before installing the transmitter, read the cautionary notes in section 2.4, “Selecting the Installation Location.” For additional information on the ambient conditions allowed at the installation location, refer to subsection 10.1 “Standard Specications.”
NOTE
To connect this transmitter to the eld wireless network, information on connecting to eld wireless devices needs to be set beforehand. Refer to 6.4 “Connecting to the Field Wireless Network.”
IMPORTANT
• When welding piping during construction, take care not to allow welding currents to ow through the transmitter.
• Do not step on this instrument after installation.
• For the EJX438B, there is a small hole in the low pressure side cover ange that is used to measure the atmospheric pressure.
The hole must not face upward. See section
10.4, “Dimensions,” for the location of the hole.
• Never loosen the four bolts securing the cover anges (Refer to gure 3.2.) If the seal liquid leaks, the transmitter cannot be used.

4.2 Mounting the Diaphragm Seals

Mount the diaphragm seals using the anges as shown in Figure 4.1. Figure 4.2 and Figure 4.3 shows how to mount the diaphragm seals on a tank. The mating ange, gasket, bolts and nuts are to be procured by the customer.
Bolt
The product is shipped with these parts assembled.
Correctly install the diaphragm seals on the high and low pressure sides of the process (The label on each diaphragm seal is marked HIGH or LOW.)
Figure 4.1 Mounting the Diaphragm Seals
Diaphragm
Ød
Gasket
Nut
F0401.ai
IMPORTANT
Please use a gasket with an inside diameter (ød) that is greater than the diameter of the diaphragm seal. If a gasket with a smaller inside diameter is used, the diaphragm may not function correctly. (Refer to Subsection 10.4 ‘Dimensions’)
IM 01C27H01-01EN
<4. Installation>
Low
IMPORTANT
• When measuring the liquid level of the tank, the minimum liquid level (zero point) must
IMPORTANT
Install the sealed diaphragm so that the shank positions downward.
pressure side
be set to a level at least 50 mm above the center of the high pressure side diaphragm seal (see Figure 4.2).
• Correctly install the diaphragm seals on the high and low pressure sides of the process,
High pressure side
checking the label on each seal.
• To avoid measuring error duets temperature difference between the two diaphragm seals, capillary tube must be bound together. The capillary tube must be securely xed to the tank wall to prevent movement by wind or vibration. If the capillary tube is too
The transmitter should be installed as low as possible below the position where the high pressure side diaphragm seal is installed.
long, loosely coil the extra tube portion (coil diameter of 300 mm or more) and secure the coiled tube with a clamp.
Figure 4.2 Installing the Diaphragm Seals to a
Tank (differential pressure transmitter)
• During the diaphragm seal installation, ensure as far as possible that no seal liquid head pressure is applied to the diaphragm seals.
• Exercise care so as not to damage
IMPORTANT
Install the sealed diaphragm so that the shank positions downward.
diaphragm surfaces. Since the diaphragm protrudes approx. 1 mm from the ange surface, do not place the pressure detector section face down on a surface as this can damage the diaphragm.
• Do not sharply bend or twist capillary tube or apply excessive stress to them.
4-2
Minimum liquid level
50mm minimum
F0402.ai
F0403.ai
Figure 4.3 Installing the Diaphragm Seals to a
Tank (pressure transmitter)

4.3 Transmitter Mounting

■ The transmitter can be mounted on a nominal 50 mm (2-inch) pipe using the mounting bracket supplied, as shown in Figure 4.4. The transmitter can be mounted on either a horizontal or a vertical pipe.
IM 01C27H01-01EN
<4. Installation>
(P–P0) × dHg
4-3
■ When mounting the bracket on the transmitter, tighten the (four) bolts that hold the transmitter to a torque of approximately 39 N·m {4 kgf·m}.
IMPORTANT
The transmitter should be installed at least 600 mm below the high pressure (HP) process connection to ensure a positive head pressure of ll uid. Pay special attention to vacuum applications.
Refer to “When the transmitter can’t be
installed at least 600 mm below the HP process connection” if the transmitter can’t be installed at least 600 mm below.
Never loosen the four bolts securing the cover ange or the screws at the joints between the capillary tube and cover anges (Refer to gure 3.2.) If the seal liquid leaks, the transmitter cannot be used.
Transmitter mounting bolt
U-bolt nut
Vertical pipe mounting
Mounting bracket
50mm (2-inch) pipe
U-bolt
■ When the transmitter can’t be installed at least 600 mm below the HP process connection.
IMPORTANT
The transmitter should be installed at least 600 mm below the high pressure (HP) process connection to ensure a positive head pressure of ll uid. Pay special attention to vacuum applications. If it can not be installed at least 600 mm below the HP process connection, please use the equation below:
h = ×7.5×10–3 [mm]
h: Vertical height between the HP process
connection and the transmitter (mm) h≤0: Install the transmitter at least h (mm) below the HP process connection h>0: Install the transmitter at most h (mm)
above the HP process connection P: Pressure in the tank (Pa abs) P0: Minimum working pressure limit of
the transmitter (Pa abs) If the ambient
temperature range is –10 to 50°C.
2951 (Wetted parts material code SW, SE
and SY)
3185 (Wetted parts material code TW)
4573 (Wetted parts material code HW)
3810 (Wetted parts material code UW) ds: Specic gravity of ll uid (at 25°C), refer
to table 10.1 on section 10.1 General
Specications. dHg:Specic gravity of the Mercury 13.6 (at
25°C)
ds
Figure 4.4 Transmitter Mounting
U-bolt nut
Mounting bracket
U-bolt
Transmitter mounting bolt
50mm (2-inch) pipe
F0404.ai
IM 01C27H01-01EN
<4. Installation>
4-4
Low pressure side
P
h
High pressure
(+)
side
0
(–)
F0405.ai
Figure 4.5 Example of Installation to Tank for
Differential Pressure Transmitter (Caution on Installation)

4.4 Mounting the Flushing Connection Ring

4.4.1 Mounting to Pressure Detector Section

The ushing connection ring is mounted to the pressure detector section as shown in Figure 4.7. At the factory shipment, the ushing connection ring is already assembled and attached to process detector section.
Pressure-detector section
Ring
Drain/vent plug
Spiral gasket
Ring holder
h
(+)
0
(–)
P
Figure 4.6 Example of Installation to Tank for
Gauge Pressure Transmitter (Caution on Installation)
F0406.ai
Groove for installing spiral gasket
View from pressure detector section
F0407.ai
Figure 4.7 Mounting to Pressure Detector Section
(1) Mount the ring holder on the ring and loosely
tighten the mounting screws.
(2) Place the spiral gasket in the ring groove. With
the ring correctly aligned and ush with the face of the pressure detector, securely tighten each ring holder’s mounting screws.
(3) Position the ring so that the drain/vent plugs are
aligned straight up and down.

4.4.2 Mounting to Process Flange

Tighten the bolts to completely close the gap between the ring and the pressure detector section. The mating ange, gasket, stud bolts and nuts are to procured by the customer.
IM 01C27H01-01EN
<4. Installation>
Teflon film
IMPORTANT
Mating flange
Gasket
Figure 4.8 Mounting to Process Flange
Spiral gasket
Ring
Diaphragm
Pressure-detector section
F0408.ai
1) Position the diaphragm seal so that the diaphragm is in a upward position.
2) Pour the uorinated oil on the diaphragm and gasket area covering it completely and evenly. Be careful not to scratch the diaphragm or change the its shape.
3) Afx the teon lm over the diaphragm and gasket area.
4) Next, carefully inspect the cover and try to identify any entrapped air between the diaphragm and the teon lm. The air must be removed to ensure optimum performance. If air pockets are present, use your ngers to remove the air by starting at the center of the diaphragm and work your way out.
5) Position the gasket on the Teon lm.
6) Mount the transmitter onto the process ange.
IMPORTANT
4-5
• Conrm that there is no gap between the ring and the process-detector section after they are mounted on the process ange. A gap can lead to a sudden, explosive release of process uids.
• When mounting or removing the ring, take care not to tilt the pressure detector downward as the ring can slip off and cause injury.
• When re-mounting the ring, use the new spiral gasket as shown in below table.
Table 4.1 Spiral Gasket for Pressure Detector
Section Side*
Part number Size Description F9350SV ø100×ø120×t4.5 For 3-inch ange F9970XF ø100×ø120×t4.5 For 3-inch ange** F9350ST ø70×ø90×t4.5 For 2-inch ange F9970XD ø70×ø90×t4.5 For 2-inch ange** F9346ZH ø60×ø75×t4.5 For 1 1/2-inch ange F9970XB ø60×ø75×t4.5 For 1 1/2-inch ange**
*: Material; 316SST (Hoop), PTFE Teon (Filler) **: For oil-prohibited use (Option code: /K1, /K5)
4.5 Afxing the Teon Film
The FEP Teon option includes a teon lm and uorinated oil. Before mounting the diaphragm seal to the process ange, afx the teon lm as follows:
PART No.
F9347XA F9347YA
Fluorinated oil [PART No.: F9145YN]
Diaphragm
Gasket area
Diaphragm seal
Figure 4.9 Afxing the Teon Film
Process flange size
For 3inch (80 mm) For 2inch (50 mm)
F0409.ai

4.6 Rotating Transmitter Section

WARNING
Intrinsic safe type transmitters must be, as a rule, do not rotate transmitter section if it is powered. In case you need to rotate when the transmitter is powered, using gas detector and conrm no existence of explosive gas before rotating.
IM 01C27H01-01EN
<4. Installation>
4-6
The transmitter section can be rotated approximately 360° (180° to either direction or 360° to one direction from the original position at shipment, depending on the conguration of the instrument.) It can be xed at any angle within above range.
1) Remove the ve setscrews that fasten the transmitter section and capsule assembly, using the Allen wrench.
2) Rotate the transmitter section slowly and stop it at designated position.
3) Tighten the ve setscrews to a torque of 1.5 N·m.
IMPORTANT
Do not rotate the transmitter section more than the above limit.
Transmitter section
Rotate 180°segments

4.8 Changing the direction of the antenna

Adjust the direction of the antenna to be in the upright position. Figure 4.11 shows factory setup antenna position. If the transmitter is installed to vertical impulse piping, follow the procedure below and change the antenna position.
1) Loosen the two mounting screws at the bottom of the antenna by using a 2.5 mm Allen wrench (see Figure 4.11).
The screws might come off and be lost if
loosened too much; loosen the screws by about three rotations.
2) Press forward and down 90 degrees by rotating the axis at the bottom of the antenna.
3) Tighten the two screws to a torque of 1.5 N·m by using a torque wrench. When doing this, be careful not leave a gap between the antenna and housing.
Pressure-detector section
F0410.ai
Figure 4.10 Rotating Transmitter Section

4.7 Changing the Direction of Integral Indicator

WARNING
Intrinsic safe type transmitters must be, as a rule, remove a battery pack in non-hazardous area before open/close the Amplier Cover or disassembling and reassembling the Integral Indicator.
An integral indicator can be rotated in four positions at 90°. Follow the instructions in section 8.4.1 for removing and attaching the integral indicator.
F0411.ai
Figure 4.11 Mounting Screw Position
F0412.ai
Figure 4.12 Adjusting Antenna Position
IM 01C27H01-01EN
<5. Wiring>

5. Wiring

5.1 Mounting Antenna and Wiring

For Amplier housing code 8 and 9, an antenna is not attached to the transmitter. The following provides the instructions for mounting the antenna and installing the remote antenna and wiring using antenna extension cable.
IMPORTANT
5-1
The antenna connector is covered with a cap at the time of delivery. Keep the cap attached until the installation of the antenna or antenna cables to protect the inside connection part. The unscrewed cap should be stored in order to replace it immediately after the antenna or antenna cables are removed.
CAUTION
To maintain the ultimate conditions of radio­frequency signal, protect the connectors of antenna, extension antenna cable, and arrester from the corrosive atmosphere by the following treatment.
1. Clean the connection to be protected.
2. Wind the butyl rubber self-bonding tape around the connection. See the manual of the tape about the winding.
3. To protect the butyl rubber self-bonding tape from the environment such as ultraviolet rays and so on, wind vinyl tape (or a vinyl type self-bonding tape) on it.
Antenna connector
F0501.ai
Figure 5.1 Mounting the antenna
CAUTION
When installing the antenna, screw the antenna by tightening the lower nut part. Screwing the antenna by holding the antenna body may cause failure such as cable disconnection. The same manner should be taken when unscrewing the antenna.

5.1.1 Mounting the antenna

Screw the provided antenna into the antenna connector of the transmitter. The antenna may be sold as available accessories and supplied separately.
1. Unscrew the antenna connector cap on the
antenna connector.
2. Screw the provided antenna into the antenna
connector. Tighten the antenna connector with a torque of 2 to 3 N∙m.
Antenna body
Nut part
F0502.ai
Figure 5.2 Antenna
IM 01C27H01-01EN
<5. Wiring>
5-2

5.1.2 Mounting External Antenna and Wiring Antenna Extension Cable

5.1.2.1 Mounting of External Antenna

Mount the external antenna at the proper location according to the wireless environment described in 2.4 Selecting the Installation Location. The mounting to the pipe such as 50 mm (2-inch) pipe needs to secure the enough strength to endure a strong wind, vibration and so on. The antenna must be mounted vertically.
Fixing of External Antenna
Fix an external antenna appropriately using the bracket provided as the external antenna option to 50 mm (2-inch) pipe.
Vertical pipe mounting
2-inch pipe
U Bolt
Horizontal pipe mounting
Antenna
Nut
Mounting Procedure of External
Antenna
1. Fix the bracket by U-bolt and nut to 50 mm (2­inch) pipe.
2. Fix the antenna extension cable to the bracket 1 using the provided nut with a torque of 6 to 7 N∙m as shown in the Figure 5.3 above. Use the nut which is attached to the antenna extension cable.
3. Screw the antenna into the antenna connector of the antenna extension cable on the bracket
1.
Tighten the antenna connector with a torque of
2 to 3 N∙m.
4. Protect the connection as necessary. For details of the protection, see “5.1 Mounting Antenna and Wiring.”

5.1.2.2 Wiring of Antenna Extension Cable

1. Use the provided antenna extension cable to connect the antenna connector with the external antenna. Tighten the connector of the antenna extension cable with a torque of 2 to 3 N∙m. The minimum bending radius while checking the wiring position should be more than 200 mm.
2. When using two extension cables, the provided arrester should be inserted between these cables.
3. Before the wiring work, conrm the polarities (male/female) of the connectors of antenna, extension antenna cable, and arrester. Tighten the connector of the antenna extension cable with a torque of 2 to 3 N∙m.
4. Protect the connectors of antenna, extension antenna cable, and arrester as necessary. See “5.1 Mounting Antenna and Wiring.”
5. Fix the extension antenna cable to the appropriate structure to protect the cable from the vibration, wind, and so on. The minimum bending radius for xing in the state maintained for a long period should be more than 80 mm.
Bracket
Nut
Antenna Extension Cable
Figure 5.3 Fixing the remote antenna
F0503.ai
IM 01C27H01-01EN
<5. Wiring>
Antenna
Antenna extension cable 2: 10 m
Antenna
5-3
Protect by self-bonding tape
Protect by self-bonding tape
Transmitter body
Antenna extension cable 1: 3 m
Figure 5.4 Wiring the antenna extension cable
CAUTION
Use the dedicated antenna extension cable provided by Yokogawa as accessories for the transmitters.
Arrester
Grounding cable
Antenna extension cable 1: 3 m
Transmitter body
F0504.ai
IM 01C27H01-01EN
<5. Wiring>
5-4

5.1.2.3 Mounting of Arrester and Wiring

Mount an arrester between the extension cables and connect the grounding cable to the grounding terminal of the arrester as required.
Connect the grounding cable to the grounding terminal on the transmitter body. Class C grounding with the grounding resistance of 10 Ω or less is necessary. Do not share the ground with other devices.
Antenna side
Antenna extension cable 2
Grounding cable
Arrester

5.2 Grounding

When using the antenna extension cable with an arrestor, Class C grounding with the grounding resistance of 10 Ω is required. Always ground the transmitter case in accordance with national and local electrical codes. The most effective transmitter case grounding method is a direct connection to earth ground with minimal impedance.
CAUTION
Grounding is recommended for safe operation.
Ground terminal
F0507.ai
Figure 5.7 Ground Terminal
Antenna extension cable 1
Transmitter side
Figure 5.5 Connection of the arrester and antenna
extension cable
Antenna side
Protect by self-bonding tape
Grounding cable
F0505.ai
Transmitter side
Figure 5.6 Arrester protection by self-bonding
tape
F0506.ai
IM 01C27H01-01EN
<6. Operation>
F0601.ai

6. Operation

6.1 Preparation for Starting Operation

This section describes the operation procedure for the EJX118B as shown in Figure 6.1 when measuring liquid level in a closed tank, and EJX438B as shown in Figure 6.2 when measuring pressure in a tank.
NOTE
It is required to set security and network information to enable the transmitter to be connected to the Field Wireless Network. For more details, refer to section 6.4 “Connecting to the Field Wireless Network”.
Diaphragm seal (low pressure side)
Transmitter mounting pipe 50mm (2 inches)
Figure 6.2 Pressure Measurement
Diaphragm seal
Capillary tube
Pressure transmitter
6-1
F0602.ai
Closed tank
Diaphragm seal (high pressure side)
Capillary tube
Differential pressure
transmitter
Transmitter mounting pipe 50mm (2 inches)
Figure6.1 Liquid Level Measurement in a Closed
Tank
(a) Conrm that there is no leak in the connecting
part of each diaphragm seal mounting ange.
(b) Insert batteries into the battery case, and install
to the transmitter. To insert batteries into the battery case, be careful to polarity of batteries and battery case. For details of Installation of battery, refer to section 8.4.4 and 8.4.5.
Battery case is installed in the transmitter when
shipped from the factory, however, batteries are sold separately and not included.
(c) Using the device conguration tool, conrm
that the transmitter is operating properly. Check parameter values or change the setpoints as necessary.
Integral Indicator’s indication can be used to conrm that the transmitter is operating properly. For details on how to conrm, refer to subsection
7.4 “Self-Diagnostics”. ISA100 devices display self-diagnostic information in an easy-to-understand manner using four categories (Check function, Maintenance required, Failure, and Off specication) according to NAMUR NE107*.
* NAMUR NE107 “Self-Monitoring and Diagnosis of Field
Devices”
IM 01C27H01-01EN
<6. Operation>
6-2
Conrm that transmitter is operating
properly by integral indicator.
• If the transmitter is faulty, an error code is displayed.
Self-diagnostic error on integral indicator (Faulity transmitter)
F0603.ai
Figure 6.3 Integral Indicator with Error Code
NOTE
If any of the above errors are indicated on the display of the integral indicator or the device conguration tool, refer to subsection 8.5.3 for the corrective action.
(1) When you can obtain the Low Range Value
from the actual measured value of 0% (0 kPa, atmospheric pressure);
■ Using the transmitter’s zero-adjustment screw
Before adjusting zero point, make sure followings.
• The External zero trim parameter (External Zero Trim) is “Trim on”. For details, refer to section 7 “Setting Parameters”.
• Use a slotted screwdriver to turn the zero adjustment screw. Turn the screw clockwise to increase the output or counterclockwise to decrease the output.
• The zero point adjustment can be made with a resolution of 0.01% of the setting range. The degree of zero adjustments varies with the screw turning speed; turn the screw slowly to make a ne adjustment, quickly to make a rough adjustment.
Verify and Change Transmitter Parameter Setting and Values
The parameters related to the following items are minimum required to be set for operation, and set at factory as specied in order. Conrm or change the parameters if needed.
• Measurement range(measurement lower/upper limit, unit)
• Output (Non linearization mode / Sq root mode)

6.2 Zero Point Adjustment

After completing preparations for operating the transmitter, adjust the zero point. There are two zero point adjusting ways.
IMPORTANT
Do not turn off the power to the transmitter immediately after performing a zero point adjustment. Powering off within 30 seconds of performing this procedure will return the zero point to its previous setting.
External Zero Adjustment Screw
F0604.ai
Figure 6.4 External Zero Adjustment Screw
IM 01C27H01-01EN
<6. Operation>
0.8
6-3
■ Using the Device Conguration Tool
Refer to subsection 7.3.14 “Zero-point Adjustment and Span Adjustment”.
(2) When you cannot obtain the Low Range
Value from the actual measured value of 0%;
Adjust the transmitter output to the actual measured value obtained by a glass gauge, etc.
[Example] The measuring range of 0 to 2m; the actual measured value of 0.8m
Actual measured value=
■ Using the transmitter’s zero-adjustment screw
Turn the zero adjustment screw to match the output signal to the actual measured value.
■ Using the Device Conguration Tool
Refer to subsection 7.3.14 ”Zero Point Adjustment and Span Adjustment”.
x100=40.0%
2

6.3 Starting Operation

After completing the Zero Point Adjustment, follow the procedure below to start operation.
1) Conrm the operating status.
2) After conrming the operating status, perform the following:

6.4 Connecting to the Field Wireless Network

Preparation work prior to connecting to a
Field Wireless Network
This transmitter does not need to be connected with a physical wire. Instead of physical wiring, it is necessary to set the eld wireless devices to communicate with before installing the transmitter. This procedure is called a provisioning. This transmitter supports provisioning via infrared communication using a provisioning device and can be securely connected to a network. If the provisioning information is not set, the transmitter cannot be connected to the eld wireless network.
Provisioning:
Provisioning is work to set the security and
network information to enable the transmitter to be connected to the eld wireless network. This transmitter supports a provisioning method using infrared communication.
For details on provisioning using a provisioning device, and procedure for connecting the transmitter to the Field Wireless Network, refer to the User’s Manual, FieldMate Versatile Device Management Wizard (IM 01R01A01-01E), YFGW710 Field Wireless Integrated Gateway (IM 01W01F01-01EN) and YFGW410 Field Wireless Management Station (IM 01W02D01-01EN).
IMPORTANT
• Close the terminal box cover and the amplier cover. Screw each cover in tightly until it will not turn further.
• Tighten the zero-adjustment cover mounting screw to secure the cover.
within 30cm
F0605.ai
Figure 6.5 Provisioning Example
IM 01C27H01-01EN
<6. Operation>
6-4
Provisioning work
This subsection describes provisioning work using FieldMate as the provisioning device. Provisioning work performs provisioning for each eld wireless device using FieldMate and an infrared adapter. If Yokogawa-recommended infrared device is used for provisioning, distance between the transmitter glass window and the infrared device should be within 30cm. For details of Yokogawa­recommended infrared device, refer to subsection
8.2 “Calibration Instruments Selection”. Perform the following provisioning tasks.
• Setting provisioning information
• Creating a provisioning information le
1) Setting provisioning information Set the device tag and network ID using a
FieldMate provisioning function. The device tag, network ID, and join key are set in the eld wireless device. It is not necessary to input a join key because FieldMate automatically generates it.
Setting device tag
The device tag is used for the user to
recognize the Field Wireless Device.
Setting network ID
This is the network ID for the eld wireless
network to which the eld wireless device is connected. Set a value from 2 to 65535.
The eld wireless device is connected to the
eld wireless network corresponding to the network ID set by provisioning work.
2) Creating a provisioning information le The following provisioned information is stored
in the provisioning information le.
Connecting to a eld wireless network
The action after installing the battery pack varies depending on the silence setting. Mounting the battery pack automatically starts a search for the eld wireless network. When the Field Wireless Integrated Gateway is found, the instrument enters the join status. When the Field Wireless Integrated Gateway is not found and a specied time based on the silence mode has elapsed, a cycle of a one-hour pause and six-minutes search is repeated until the instrument can join the eld wireless network. For details on the procedure to switch to silence mode, refer to subsection 7.3.17 “Switching to Silence Mode.”
Mounting battery pack
Boot
Search failure for
Infrared communication
Deep sleep (a)
(Disconnect)
Deep sleep setting
Operation (d)
Figure 6.6 Wireless Connection Process
the specified time
Infrared communication
Ready 1: Searching (b)
Infrared communication
(Disconnect)
(Connect)
Confirm connecting status: Join (c)
(Publish)
Pause (b)
1 hour passed
Search failure for 6 minutes
Ready 2: Searching (b)
(Connect)
F0606.ai
• Network ID
• Device tag
• EUI64
• Join key
• Provisioner (name of the user who performed provisioning work by FieldMate)
• Date (Time and date when provisioning was performed by FieldMate)
This provisioning information le is required to
load from the Field Wireless Congurator to the Field Wireless Integrated Gateway. Store the le carefully.
IM 01C27H01-01EN
<6. Operation>
(a) Deep sleep
NOTE
If the transmitter searches the Field Wireless Network for long time at low ambient temperature condition, sometimes error “AL.70 LOWBAT” is displayed on the Integral Indicator. Even though using new batteries, it can occur. It occurs because of battery characteristics. After joining to the Field Wireless Network, this error will be cleared within one hour if battery has
F0607.ai
(b) Ready and pause
no failure.

6.5 Shutting Down The Transmitter

When shut down the transmitter, remove the battery pack or set the transmitter to deep sleep mode by the Device Conguration Tool.
6-5
(c) Conrm connecting status
(d) Join
F0608.ai
F0609.ai
F0610.ai
NOTE
Whenever shutting down the transmitter for a long period, detach the transmitter (diaphragm seals) from the tank
• Refer to subsection 8.4.4 “Replacing the Battery Pack” for the battery pack removing.
• When storing the instrument with a battery pack inserted, it is recommended to put the instrument into deep sleep mode to conserve battery power. For details on how to switch to deep sleep mode, refer to subsection 7.3.16 “Switching to the Deep Sleep Mode”.
6.6 Venting or Draining Transmitter Process­Detector Section
If condensate (or gas) collects in the transmitter process-detector section, the measured pressure may be in error. If it is not possible to congure the piping for self draining (or self-venting) operation, you will need to loosen the drain (vent) screw on the ushing connection ring to completely drain (vent) any stagnated liquid (gas). However, since draining condensate or bleeding off gas gives the pressure measurement disturbance, this should not be done when the loop is in operation.
IM 01C27H01-01EN
<6. Operation>
When you loosen the drain screw,
6-6
WARNING
Since the accumulated liquid (or gas) may be toxic or otherwise harmful, take appropriate care to avoid contact with the body, or inhalation of vapors.

6.6.1 Draining Condensate for Flushing Connection Ring

1) Gradually open the drain screw to drain from
the ushing connection ring.(See gure 6.7.)
2) When the ushing connection ring is completely
drained, close the drain screw.
3) Tighten the drain screw to a torque of 10 N·m
{1 kgf·m}.
the accumulated liquid(or gas) will be expelled in the direction of the arrow.
Drain screw
F0611.ai
Figure 6.7 Draining for Flushing Connection Ring

6.6.2 Venting Gas for Flushing Connection Ring

1) Gradually open the vent screw to vent gas from
the ushing connection ring.(See gure 6.8.)
2) When the ushing connection ring is completely
vented, close the vent screw.
3) Tighten the vent screw to a torque of 10 N·m
Vent screw
When you loosen the vent screw, the accumulated liquid(or drain) will be expelled in the direction of the arrow.
F0612.ai
Figure 6.8 Venting for Flushing Connection Ring
IM 01C27H01-01EN
<7. Setting Parameters>

7. Setting Parameters

7-1
This transmitter can remotely handle range changes, Tag No. setup, monitoring of self­diagnostic results, and zero point adjustment, etc. according to communication with the eld wireless conguration tool or the device conguration tool.

7.1 Environment for parameter setting

After installing the battery pack, perform provisioning and have the instrument join the eld wireless network. This transmitter supports the OOB (out-of-band) method using the infrared communication as a provisioning method. Refer to Subsection 6.4 “Connecting to the Field Wireless Network” for details of the provisioning.
CF (Capabilities File)/DD (Device Description)
A CF le contains information, such as the
vendor of the eld device, its model and revision, available types of process data (ow rate, temperature, pressure, etc.), and number of data items. A DD le contains the information on parameters, such as data structures and attributes.
DeviceDTM
DeviceDTM (Device Type Manager), is driver
software for eld devices provided based on the FDT (Field Device Tool) technology.
The eld wireless conguration tool or the device conguration tool allows conrming the device information. Refer to Subsection 8.2 “Calibration Instruments Selection” for the eld wireless conguration tool or the device conguration tool of our recommendation.

7.2.2 Software Download

Infrared port
F0701.ai
Figure 7.1 Infrared port of the transmitter

7.2 Preparing Software

7.2.1 Softwares for the Field Wireless Conguration Tool and the Device Conguration Tool
Before using the device conguration tool, conrm that CF/DD and DeviceDTM for your transmitter (wireless EJX) are installed in the device conguration tool. CF/DD and DeviceDTM are provided by DVD-ROM attached to YFGW710 Field Wireless Integrated Gateway. Refer to YFGW710 Field Wireless Integrated Gateway (IM 01W01F01-01EN) for details.
Software download function permits to update wireless eld device software via ISA100.11a wireless communication. For details, refer to YFGW710 Field Wireless Integrated Gateway (IM 01W01F01-01EN) or YFGW410 Field Wireless Management Station (IM 01W02D01-01EN).

7.3 Setting Parameters

7.3.1 Parameter Usage and Selection

Before setting a parameter, please see the following table for a summary of how and when each parameter is used.
IMPORTANT
After setting and sending data with the eld wireless conguration tool or the device conguration tool, wait 30 seconds before turning off the transmitter. If it is turned off too soon, the settings will not be stored in the transmitter.
IM 01C27H01-01EN
<7. Setting Parameters>
7-2
Table 7.1 Parameter Usage and Selection
Item Description
Tag No. Sets the tag No. as Device Tag (Software Tag). Sixteen characters
(alphanumeric characters, including - and •) can be set.
Output The process variable and the diagnostic result can be output.
Either or all of differential pressure (AI1:Process Value), static pressure (AI2:Process Value), temperature(AI3:Process Value) of capsule or amplier and self-diagnostic information (UAPMO:Diagnostic Status) can be set to the output
Range Adjust the range corresponding for 0% to 100%.
The unit of the range, input value at 0% (LRV) and input value at 100% (URV) is set.
Note: LRV and URV can be set within the range of -32000 to 32000.
Damping time constant Damping time constant is used to reduce the large uctuation of pressure
signal and given by each Process Value Filter Time parameter for differential Pressure/pressure (AI1) and Static pressure (AI2).
Output signal and integral indicator mode Sets mode for output signal and integral indicator to “linear mode”
(proportional to input differential pressure) or to “Square root mode” (proportional to ow).
Output signal low cut mode Used mainly to stabilize output near 0 if output signal is the square root
mode. Two modes are available: forcing output to 0% for input below a specic value, or changing to proportional output for input below a specic value.
Integral indicator range of scale and unit Sets one of differential pressure/pressure value, static pressure value, or
temperature value for the integral indicator scale.
Note: LRV and URV can be set within the range of -32000 to 32000.
Unit for displayed temperature Sets a temperature unit to be displayed. Unit for displayed static pressure Sets a pressure unit for the static pressure to be displayed Direction of impulse piping connection
(which is high pressure, L side or R side)
Used where installation conditions makes it imperative to connect high pressure side impulse line to low pressure side of transmitter.
Normally, correspond by replacing impulse line, and use this function only when unavoidable.
Range with actual input applied Range corresponding for 0% to 100% signal is set with actual input
applied. The output setting can be done just 100% to user’s reference pressure
output. However, when shipping it, the calibration is done in high accuracy as for
DPharp. Please do the span setting by a usual range setting.
Zero Point Adjustment and Span Adjustment Handle Zero Point Adjustment and Span Adjustment.
There are two methods of Zero Point Adjustment, using external zero-
adjustment screw and using the device conguration tool. Reset adjustment The amount of the adjustment set by user can be cleared. Software write protect Prohibit writing the setting data. Operational mode Set the operational mode of the sensor and integral indicator, etc.
Note: Some of the parameter settings are in the dialogue form called method, the on-line instructions you can congure the parameters
easily.
IM 01C27H01-01EN
<7. Setting Parameters>
7-3

7.3.2 Function Block and Menu Tree

(1) Function Block
The function of this transmitter is shown below. A specic function might not be able to be used according to the eld wireless conguration tool used. When the eld wireless conguration tool of our recommendation is used, the software attached to the Field Wireless Integrated Gateway is necessary for setting the dotted line part. Refer to Subsection 8.2 “Calibration Instruments Selection” for the eld wireless conguration tool of our recommendation.
(a) Integral antenna type (Amplier housing code: 7)
Online Menu
UAPMO
UDO
CO
TRANSDUCER
AI1 DP
AI2 SP
AI3 Temp
(UAPMO)
Configuration
Diagnostics/Alerts
Power Status
Identification
(UDO)
APP Download
(CO)
Configuration
Others
(TRANSDUCER)
Block Info
Configuration/
Calibration
Others
(Configuration)
UAP Option
Hardware Write Protect
Static Revision
Reset Energy Left
Radio Silence
(Diagnostics/Alerts)
Diagnostic Status
Diagnostic Status Detail1,
Diagnostic Status Detail2
Diagnostic Switch
Diagnostic Configuration
(Power Status)
Energy Left
Power Supply Status
(Identification)
Version Revision
CTS Version
ITS Version
Identification Number
(APP Download)
DESCRIPTION
STATE
MAX_BLOCK_SIZE
LAST_BLOCK_DOWNLOADED
ERROR_CODE
(Configuration)
COMM_ENDPOINT
COMM_CONTRACT
PUB_ITEM_MAX
PUB_ITEM_NUM
PUB_ITEM
(Others)
REVISION
(Block Info)
Tag Description
(Configuration/Calibration)
Auto Recovery
Model
Sensor Serial Number
Measurement Rate
Measurement Mode
Wireless Status
Display Selection
LCD Mode
Special Order ID
Unit Sel1
Display Unit1
EJX Key
Test Key 1
Test Key 2
Test Key 3
(Others)
Special Cmd
(COMM_ENDPOINT)
Network address of remote endpoint
Transport layer port at remote endpoint
Object ID at remote endpoint
Stale data limit
Data publication period
Ideal publication phase
PublishAutoRetransmit
Configuration status
(COMM_CONTRACT)
ContractID
Contract_Status
Actual_Phase
(PUB_ITEM)
ObjectID
AttributeID
AttributeIndex
Size
F0702-1.ai
IM 01C27H01-01EN
<7. Setting Parameters>
Online Menu (continued)
7-4
(AI1 DP)
• Block Info
• Block Mode
• Dynamic Variables
• Configuration
• Calibration
• Others
(Block Info)
• Tag Description
(Block Mode )
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Dynamic Variables)
• Process Value
• Simulation
(Configuration)
• Block Mode
• Concentrator OID
• Scale *
• Process Value Filter Time
(Process Value)
• Process Value.Status
• Process Value.Value **
(Simulation)
• Simulate Switch
• Transducer Value
• Simulate Value
(Block Mode)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Scale)
• Scale.EU at 100% *
• Scale.EU at 0% *
• Scale.Units Index *
• Scale.Decimal *
(Transducer Value)
• Transducer Value. Status
• Transducer Value. Value
(Simulate Value)
• Simulate Value. Status
• Simulate Value. Value
(Calibration)
• Block Mode
• Cal Cmd *
• Cal Status
• Calibration Highest Point *
• Calibration Lowest Point *
• Calibration Minimum Span
• External Zero Trim *
(Others)
• Upper Limit
• Lower Limit
• PV Range *
• Linerization Type *
• Flow Constant *
• Lower cutoff
• Low Cut Mode *
• H/L Swap *
• T Zero Cmp *
• Temp Zero *
• Temp Select *
(Block Mode)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(PV Range)
• PV Range.EU at 100% *
• PV Range.EU at 0% *
• PV Range.Units Index *
• PV Range.Decimal *
F0702-2.ai
*: When the data of these parameters is rewritten, it is necessary to set the operational mode of the block to O/S (Out of Service). **: When the data of these parameters is rewritten, it is necessary to set the operational mode of the block to Manual.
IM 01C27H01-01EN
<7. Setting Parameters>
Online Menu (continued)
7-5
(AI2 SP)
• Block Info
• Block Mode
• Dynamic Variables
• Configuration
• Others
(Block Info)
• Tag Description
(Block Mode )
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Dynamic Variables)
• Process Value
• Simulation
(Configuration)
• Block Mode
• Concentrator OID
• Scale *
• Process Value Filter Time
(Process Value)
• Process Value.Status
• Process Value.Value **
(Simulation)
• Simulate Switch
• Transducer Value
• Simulate Value
(Block Mode)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Scale)
• Scale.EU at 100% *
• Scale.EU at 0% *
• Scale.Units Index *
• Scale.Decimal *
(Transducer Value)
• Transducer Value. Status
• Transducer Value. Value
(Simulate Value)
• Simulate Value. Status
• Simulate Value. Value
(Others)
• Upper Limit
• Lower Limit
• PV Range *
• Linerization Type *
• Flow Constant *
• Lower cutoff
• Cal Cmd *
• Cal Status
• Calibration Highest Point *
• Calibration Lowest Point *
• Calibration Minimum Span
• Static Pres Type *
• SP Select *
(PV Range)
• PV Range.EU at 100% *
• PV Range.EU at 0% *
• PV Range.Units Index *
• PV Range.Decimal *
F0702-3.ai
*: When the data of these parameters is rewritten, it is necessary to set the operational mode of the block to O/S (Out of Service). **: When the data of these parameters is rewritten, it is necessary to set the operational mode of the block to Manual.
IM 01C27H01-01EN
<7. Setting Parameters>
Online Menu (continued)
7-6
(AI3 Temp)
• Block Info
• Block Mode
• Dynamic Variables
• Configuration
• Others
(Block Info)
• Tag Description
(Block Mode )
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Dynamic Variables)
• Process Value
• Simulation
(Configuration)
• Block Mode
• Concentrator OID
• Scale *
• Process Value Filter Time
(Process Value)
• Process Value.Status
• Process Value.Value **
(Simulation)
• Simulate Switch
• Transducer Value
• Simulate Value
(Block Mode)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Transducer Value)
• Transducer Value. Status
• Transducer Value. Value
(Simulate Value)
• Simulate Value. Status
• Simulate Value. Value
(Scale)
• Scale.EU at 100% *
• Scale.EU at 0% *
• Scale.Units Index *
• Scale.Decimal *
(Others)
• Sensor Range
• Tertiary Value Sel *
(Sensor Range)
• Sensor Range.EU at 100%
• Sensor Range.EU at 0%
• Sensor Range.Units Index **
• Sensor Range.Decimal **
F0702-4.ai
*: When the data of these parameters is rewritten, it is necessary to set the operational mode of the block to O/S (Out of Service). **: When the data of these parameters is rewritten, it is necessary to set the operational mode of the block to Manual.
IM 01C27H01-01EN
<7. Setting Parameters>
(b) Detachable antenna type (Amplier housing code: 8 or 9)
7-7
Online Menu
UAPMO
UDO
CO
TRANSDUCER
AI1 DP
AI2 SP
AI3 Temp
(UAPMO)
Configuration
Diagnostics
Alerts
Power Status
Identification
(UDO)
APP Download
(CO)
Configuration
Others
(TRANSDUCER)
Block Info
Configuration/
Calibration
Others
(Configuration)
UAP Option
Hardware Write Protect
Static Revision
Reset Energy Left
Radio Silence
Energy Harvest Type
(Diagnostics)
Diagnostic Status
Diagnostic Status Detail.1
Diagnostic Status Detail.2
Diagnostic Switch
Diagnostic Configuration
(Power Status)
Energy Left
Power Supply Status
Power Supply Voltage
(Identification)
Version Revision
CTS Version
ITS Version
Identification Number
(APP Download)
DESCRIPTION
STATE
MAX_BLOCK_SIZE
LAST_BLOCK_DOWNLOADED
ERROR_CODE
(Configuration)
COMM_ENDPOINT
COMM_CONTRACT
PUB_ITEM_MAX
PUB_ITEM_NUM
PUB_ITEM
(Others)
REVISION
(Block Info)
Tag Description
(Configuration/Calibration)
Auto Recovery
Model
Sensor Serial Number
Measurement Rate
Measurement Mode
Wireless Status
Display Selection
LCD Mode
Special Order ID
Unit Sel1
Display Unit1
LCD Intermittent Time
XD Filter
EJX Key
Test Key 1
Test Key 2
Test Key 3
(Others)
Special Cmd
(Alerts)
• Other Faults Alert
• Faults Non-compliance Alert
• Faults Process Influence Alert
• Simulation Active Alert
• Soft Update Incomplete Alert
• Power Low Alert
• Power Critical Low Alert
• Fault Prediction Alert
• Environmental Conditions Alert
• Outside Sensor Limits Alert
• Out of Service Alert
• Calibration Problem Alert
• Faults Sensor or Actuator Alert
• Faults Electronics Alert
(COMM_ENDPOINT)
Network address of remote endpoint
Transport layer port at remote endpoint
Object ID at remote endpoint
Stale data limit
Data publication period
Ideal publication phase
PublishAutoRetransmit
Configuration status
(COMM_CONTRACT)
ContractID
Contract_Status
Actual_Phase
(PUB_ITEM)
ObjectID
AttributeID
AttributeIndex
Size
F0702-5.ai
IM 01C27H01-01EN
<7. Setting Parameters>
Online Menu (continued)
7-8
(AI1 DP)
• Block Info
• Block Mode
• Dynamic Variables
• Configuration
• Calibration
• Others
(Block Info)
• Tag Description
(Block Mode )
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Dynamic Variables)
• Process Value
• Simulation
(Configuration)
• Block Mode
• Concentrator OID
• Scale *
• Process Value Filter Time
(Process Value)
• Process Value.Status
• Process Value.Value **
(Simulation)
• Simulate Switch
• Transducer Value
• Simulate Value
(Block Mode)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Scale)
• Scale.EU at 100% *
• Scale.EU at 0% *
• Scale.Units Index *
• Scale.Decimal *
(Transducer Value)
• Transducer Value. Status
• Transducer Value. Value
(Simulate Value)
• Simulate Value. Status
• Simulate Value. Value
(Calibration)
• Block Mode
• Cal Cmd *
• Cal Status
• Calibration Highest Point *
• Calibration Lowest Point *
• Calibration Minimum Span
• External Zero Trim *
(Others)
• Upper Limit
• Lower Limit
• PV Range *
• Linerization Type *
• Flow Constant *
• Lower Cutoff
• Low Cut Mode *
• H/L Swap *
• T Zero Cmp *
• Temp Zero *
• Temp Select *
(Block Mode)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(PV Range)
• PV Range.EU at 100% *
• PV Range.EU at 0% *
• PV Range.Units Index *
• PV Range.Decimal *
F0702-6.ai
*: When the data of these parameters is rewritten, it is necessary to set the operational mode of the block to O/S (Out of Service). **: When the data of these parameters is rewritten, it is necessary to set the operational mode of the block to Manual.
IM 01C27H01-01EN
<7. Setting Parameters>
Online Menu (continued)
7-9
(AI2 SP)
• Block Info
• Block Mode
• Dynamic Variables
• Configuration
• Others
(Block Info)
• Tag Description
(Block Mode )
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Dynamic Variables)
• Process Value
• Simulation
(Configuration)
• Block Mode
• Concentrator OID
• Scale *
• Process Value Filter Time
(Process Value)
• Process Value.Status
• Process Value.Value **
(Simulation)
• Simulate Switch
• Transducer Value
• Simulate Value
(Block Mode)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Scale)
• Scale.EU at 100% *
• Scale.EU at 0% *
• Scale.Units Index *
• Scale.Decimal *
(Transducer Value)
• Transducer Value. Status
• Transducer Value. Value
(Simulate Value)
• Simulate Value. Status
• Simulate Value. Value
(Others)
• Upper Limit
• Lower Limit
• PV Range *
• Linerization Type *
• Flow Constant *
• Lower Cutoff
• Cal Cmd *
• Cal Status
• Calibration Highest Point *
• Calibration Lowest Point *
• Calibration Minimum Span
• Static Pres Type *
• SP Select *
(PV Range)
• PV Range.EU at 100% *
• PV Range.EU at 0% *
• PV Range.Units Index *
• PV Range.Decimal *
F0702-7.ai
*: When the data of these parameters is rewritten, it is necessary to set the operational mode of the block to O/S (Out of Service). **: When the data of these parameters is rewritten, it is necessary to set the operational mode of the block to Manual.
IM 01C27H01-01EN
<7. Setting Parameters>
Online Menu (continued)
7-10
(AI3 Temp)
• Block Info
• Block Mode
• Dynamic Variables
• Configuration
• Others
(Block Info)
• Tag Description
(Block Mode )
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Dynamic Variables)
• Process Value
• Simulation
(Configuration)
• Block Mode
• Concentrator OID
• Scale *
• Process Value Filter Time
(Process Value)
• Process Value.Status
• Process Value.Value **
(Simulation)
• Simulate Switch
• Transducer Value
• Simulate Value
(Block Mode)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Transducer Value)
• Transducer Value. Status
• Transducer Value. Value
(Simulate Value)
• Simulate Value. Status
• Simulate Value. Value
(Scale)
• Scale.EU at 100% *
• Scale.EU at 0% *
• Scale.Units Index *
• Scale.Decimal *
(Others)
• Sensor Range
• Tertiary Value Sel *
(Sensor Range)
• Sensor Range.EU at 100%
• Sensor Range.EU at 0%
• Sensor Range.Units Index **
• Sensor Range.Decimal **
F0702-8.ai
*: When the data of these parameters is rewritten, it is necessary to set the operational mode of the block to O/S (Out of Service). **: When the data of these parameters is rewritten, it is necessary to set the operational mode of the block to Manual.
IM 01C27H01-01EN
<7. Setting Parameters>
7-11
(2) Menu Tree
The menu tree of the device conguration tool of our recommendation is shown below. Refer to Subsection 8.2 “Calibration Instruments Selection” for the device conguration tool of our recommendation.
(a) Integral antenna type (Amplier housing code: 7)
Online Menu
• Device Configuration
• Diagnostic
• Process Variable
(Device Configuration)
• UAPMO
• TRANSDUCER
• AI1 DP
• AI2 SP
• AI3 Temp
(UAPMO)
• Configure/Setup
(TRANSDUCER)
• Configure/Setup
(AI1 DP)
• Configure/Setup
(Configuration)
• UAP Option
• Hardware Write Protect
• Static Revision
• Reset Energy Left
• Radio Silence
(Identification)
• Version Revision
• CTS Version
• ITS Version
• Identification Number
(Block Info)
• Tag Description
(Configuration/Calibration)
• Auto Recovery
• Model
• Sensor Serial Number
• Measurement Rate
• Measurement Mode
• Wireless Status
• Display Selection
• LCD Mode
• Special Order ID
• Unit Sel1
• Display Unit1
• EJX Key
• Test Key 1
• Test Key 2
• Test Key 3 (Others)
• Special Cmd
(Block Info)
• Tag Description
(Block Mode)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Configuration)
• Block Mode
• Concentrator OID
• Scale *
• Process Value Filter Time
(Calibration)
• Block Mode
• Cal Cmd *
• Cal Status
• Calibration Highest Point *
• Calibration Lowest Point *
• Calibration Minimum Span
• External Zero Trim *
(Others)
• Upper Limit
• Lower Limit
• PV Range *
• Linerization Type *
• Flow Constant *
• Lower cutoff
• Low Cut Mode *
• H/L Swap *
• T Zero Cmp *
• Temp Zero *
• Temp Select *
(Block Mode)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Scale)
• Scale.EU at 100% *
• Scale.EU at 0% *
• Scale.Units Index *
• Scale.Decimal * (Block Mode)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(PV Range)
• PV Range.EU at 100% *
• PV Range.EU at 0% *
• PV Range.Units Index *
• PV Range.Decimal*
F0703-1.ai
*: When the data of these parameters is rewritten, it is necessary to set the operational mode of the block to O/S (Out of Service).
IM 01C27H01-01EN
<7. Setting Parameters>
7-12
Online Menu (continued)
Device Configuration (continued)
(AI2 SP)
• Configure/Setup
(Block Info)
• Tag Description
(Block Mode)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Configuration)
• Block Mode
• Concentrator OID
• Scale *
• Process Value Filter Time
(Others)
• Upper Limit
• Lower Limit
• PV Range *
• Linerization Type *
• Flow Constant *
• Lower cutoff
• Cal Cmd *
• Cal Status
• Calibration Highest Point *
• Calibration Lowest Point *
• Calibration Minimum Span
• Static Pres Type *
• SP Select *
(Block Mode)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Scale)
• Scale.EU at 100% *
• Scale.EU at 0% *
• Scale.Units Index *
• Scale.Decimal *
(PV Range)
• PV Range.EU at 100% *
• PV Range.EU at 0% *
• PV Range.Units Index *
• PV Range. Decimal *
(AI3 Temp)
• Configure/Setup
(Block Info)
• Tag Description
(Block Mode)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Configuration)
• Block Mode
• Concentrator OID
• Scale *
• Process Value Filter Time
(Others)
• Sensor Range
• Tertiary Value Sel *
(Block Mode)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Scale)
• Scale.EU at 100% *
• Scale.EU at 0% *
• Scale.Units Index *
• Scale.Decimal *
(Sensor Range)
• Sensor Range.EU at 100%
• Sensor Range.EU at 0%
• Sensor Range.Units Index *
• Sensor Range. Decimal *
F0703-2.ai
*: When the data of these parameters is rewritten, it is necessary to set the operational mode of the block to O/S (Out of Service).
IM 01C27H01-01EN
<7. Setting Parameters>
Online Menu (continued)
7-13
(Diagnostic)
• UAPMO
(Process Variable)
• AI1 DP
• AI2 SP
• AI3 Temp
(UAPMO)
• Device Diagnostics
(AI1 DP)
• Process Variable
(Diagnostics/Alerts)
• Diagnostic Status
• Diagnostic Status Detail1,
• Diagnostic Status Detail2
• Diagnostic Switch
• Diagnostic Configuration
(Power Status)
• Energy Left
• Power Supply Status
(Dynamic Variables)
• Process Value
• Simulation
(Process Value)
• Process Value.Status
• Process Value.Value **
(Simulation)
• Simulate Switch
• Transducer Value
• Simulate Value
(Transducer Value)
• Transducer Value. Status
• Transducer Value. Value
(Simulate Value)
• Simulate Value. Status
• Simulate Value. Value
(AI2 SP)
• Process Variable
(AI3 Temp)
• Process Variable
(Dynamic Variables)
• Process Value
• Simulation
(Dynamic Variables)
• Process Value
• Simulation
(Process Value)
• Process Value.Status
• Process Value.Value **
(Simulation)
• Simulate Switch
• Transducer Value
• Simulate Value
(Process Value)
• Process Value.Status
• Process Value.Value **
(Simulation)
• Simulate Switch
• Transducer Value
• Simulate Value
(Transducer Value)
• Transducer Value. Status
• Transducer Value. Value
(Simulate Value)
• Simulate Value. Status
• Simulate Value. Value
(Transducer Value)
• Transducer Value. Status
• Transducer Value. Value
(Simulate Value)
• Simulate Value. Status
• Simulate Value. Value
*: When the data of these parameters is rewritten, it is necessary to set the operational mode of the block to O/S (Out of Service).
F0703-3.ai
IM 01C27H01-01EN
<7. Setting Parameters>
7-14
(b) Detachable antenna type (Amplier housing code: 8 or 9)
Menu (Online)
• Device Configuration
• Diagnostic
• Process Variable
(Device Configuration)
• UAPMO
• TRANSDUCER
• AI1 DP
• AI2 SP
• AI3 Temp
(UAPMO)
• Configure/Setup
(TRANSDUCER)
• Configure/Setup
(AI1 DP)
• Configure/Setup
*: When the data of these parameters is rewritten, it is necessary to set the operational mode of the block to O/S (Out of Service).
(Configuration)
• UAP Option
• Hardware Write Protect
• Static Revision
• Reset Energy Left
• Radio Silence
• Energy Harvest Type
(Identification)
• Version Revision
• CTS Version
• ITS Version
• Identification Number
(Block Info)
• Tag Description
(Configuration/Calibration)
• Auto Recovery
• Model
• Sensor Serial Number
• Measurement Rate
• Measurement Mode
• Wireless Status
• Display Selection
• LCD Mode
• Special Order ID
• Unit Sel1
• Display Unit1
• LCD Intermittent Time
• XD Filter
• EJX Key
• Test Key 1
• Test Key 2
• Test Key 3
(Others)
• Special Cmd
(Block Info)
• Tag Description
(Block Mode)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Configuration)
• Block Mode
• Concentrator OID
• Scale *
• Process Value Filter Time
(Calibration)
• Block Mode
• Cal Cmd *
• Cal Status
• Calibration Highest Point Set Calibration Highest Point *
• Calibration Lowest Point
Set Calibration Lowest Point *
• Calibration Minimum Span
• External Zero Trim *
(Others)
• Upper Limit
• Lower Limit
• PV Range *
• Linerization Type *
• Flow Constant *
• Lower Cutoff
• Low Cut Mode *
• H/L Swap *
• T Zero Cmp *
• Temp Zero *
• Temp Select *
(Alerts)
• Other Faults Alert
• Faults Non-compliance Alert
• Faults Process Influence Alert
• Simulation Active Alert
• Soft Update Incomplete Alert
• Power Low Alert
• Power Critical Low Alert
• Fault Prediction Alert
• Environmental Conditions Alert
• Outside Sensor Limits Alert
• Out of Service Alert
• Calibration Problem Alert
• Faults Sensor or Actuator Alert
• Faults Electronics Alert
(Block Mode)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Scale)
• Scale.EU at 100% *
• Scale.EU at 0% *
• Scale.Units Index *
• Scale.Decimal *
(Block Mode)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(PV Range)
• PV Range.EU at 100% *
• PV Range.EU at 0% *
• PV Range.Units Index *
• PV Range.Decimal*
F0703-4.ai
IM 01C27H01-01EN
<7. Setting Parameters>
7-15
Menu (Online) (continued)
Device Configuration (continued)
(AI2 SP)
• Configure/Setup
(AI3 Temp)
• Configure/Setup
(Block Info)
• Tag Description
(Block Mode)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Configuration)
• Block Mode
• Concentrator OID
• Scale *
• Process Value Filter Time
(Others)
• Upper Limit
• Lower Limit
• PV Range *
• Linerization Type *
• Flow Constant *
• Lower Cutoff
• Cal Cmd *
• Cal Status
• Calibration Highest Point
• Set Calibration Highest Point *
• Calibration Lowest Point
• Set Calibration Lowest Point *
• Calibration Minimum Span
• Static Pres Type *
• SP Select *
(Block Info)
• Tag Description
(Block Mode)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Configuration)
• Block Mode
• Concentrator OID
• Scale *
• Process Value Filter Time
(Others)
• Sensor Range
• Tertiary Value Sel *
(Block Mode)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Scale)
• Scale.EU at 100% *
• Scale.EU at 0% *
• Scale.Units Index *
• Scale.Decimal *
(PV Range)
• PV Range.EU at 100% *
• PV Range.EU at 0% *
• PV Range.Units Index *
• PV Range. Decimal *
(Block Mode)
• Mode.Target
• Mode.Actual
• Mode.Permitted
• Mode.Normal
(Scale)
• Scale.EU at 100% *
• Scale.EU at 0% *
• Scale.Units Index *
• Scale.Decimal *
(Sensor Range)
• Sensor Range.EU at 100%
• Sensor Range.EU at 0%
• Sensor Range.Units Index *
• Sensor Range. Decimal *
F0703-5.ai
*: When the data of these parameters is rewritten, it is necessary to set the operational mode of the block to O/S (Out of Service).
IM 01C27H01-01EN
<7. Setting Parameters>
Menu (Online)
(continued)
7-16
(Diagnostic)
• UAPMO
(Process Variable)
• AI1 DP
• AI2 SP
• AI3 Temp
(UAPMO)
• Device Diagnostics
(AI1 DP)
• Process Variable
(Diagnostics)
• Diagnostic Status
• Diagnostic Status Detail.1
• Diagnostic Status Detail.2
• Diagnostic Switch
• Diagnostic Configuration
(Power Status)
• Energy Left
• Power Supply Status
• Power Supply Voltage
(Dynamic Variables)
• Process Value
• Simulation
(Process Value)
• Process Value.Status
• Process Value.Value **
(Simulation)
• Simulate Switch
• Transducer Value
• Simulate Value
(Diagnostic Configuration)
• Diagnostic.Other Faults
• Diagnostic.Faults Non-Compliance
• Diagnostic.Faults Process Influence
• Diagnostic.Simulation Active
• Diagnostic.Soft Update Incomplete
• Diagnostic.Power Low
• Diagnostic.Power Critical Low
• Diagnostic.Fault Prediction
• Diagnostic.Environmental Conditions
• Diagnostic.Outside Sensor Limits
• Diagnostic.Out of Service
• Diagnostic.Calibration Problem
• Diagnostic.Faults Sensor or Actuator
• Diagnostic.Faults Electronics
(Transducer Value)
• Transducer Value. Status
• Transducer Value. Value
(Simulate Value)
• Simulate Value. Status
• Simulate Value. Value
(AI2 SP)
• Process Variable
(AI3 Temp)
• Process Variable
(Dynamic Variables)
• Process Value
• Simulation
(Dynamic Variables)
• Process Value
• Simulation
(Process Value)
• Process Value.Status
• Process Value.Value **
(Simulation)
• Simulate Switch
• Transducer Value
• Simulate Value
(Process Value)
• Process Value.Status
• Process Value.Value **
(Simulation)
• Simulate Switch
• Transducer Value
• Simulate Value
(Transducer Value)
• Transducer Value. Status
• Transducer Value. Value
(Simulate Value)
• Simulate Value. Status
• Simulate Value. Value
(Transducer Value)
• Transducer Value. Status
• Transducer Value. Value
(Simulate Value)
• Simulate Value. Status
• Simulate Value. Value
*: When the data of these parameters is rewritten, it is necessary to set the operational mode of the block to O/S (Out of Service).
F0703-6.ai
IM 01C27H01-01EN
<7. Setting Parameters>
7-17

7.3.3 Parameters for Wireless Communication

(1) Network Information
Concentrator object block : Conguration
Allows conrming the network information.
(2) Update Time
CO block : Data publication period
Sets the update time value to 0.5 to 3,600 seconds. When amplier housing code 7 is specied, note that more than one second is available. When update time is set 0 seconds, the transmitter is stopped to update process variables by way of the eld wireless network. And the transmitter continues to measure process variables with special interval time internally.
(3) Measurement Mode
TRANSDUCER block : Measurement Mode
The setting affects the battery life; it becomes shorter in the continuous mode. When the update period is set to 1 second or less in intermittent mode, the mode is automatically switched to continuous mode. When the update period is 1 second, the mode is continuous mode, regardless of the measurement mode.
(4) Measurement Rate
(6) LCD display
The following steps describe how to set LCD display.
● Integral antenna type (Amplier housing code: 7)
1. On/Off of display When “LCD Intermittent” in LCD Mode is
parameter is selected, the LCD rst displays a set of screens to be shown and then turns off for a minute, and the display keeps the cycle repeatedly. Not selecting this parameter turns the LCD off.
2. On/Off of continuous display mode When “LCD Continue” in LCD Mode is
selected, the LCD displays for 5 minutes continuously then transits to the setting in the LCD Intermittent.
When measurement mode is set as continuous
mode, the LCD displays continuously regardless of display mode.
When the update time is set to 1 second, the
LCD display stays on regardless of the status in LCD Mode.
3. On/Off of bar graph Select “LCD Bargraph ON” in LCD Mode when
the bar graph is required.
● Detachable antenna type (Amplier housing code: 8 or 9)
TRANSDUCER block: Measurement Rate
Reads the measurement rate value from 0.5 to 3600 seconds. When amplier housing code 7 is specied, note that the period more than one second is displayed. The shorter the measurement period, the shorter the battery life.
(5) Remaining battery life
UAPMO block: Energy Left
The number of days of remaining battery life is indicated assuming that a transmitter has been working under ambient temperature condition as 23 degrees Celsius. It takes several days for the indicated value to be stabiilzed after the power on and initialization of the remaining battery life.
UAPMO block: Reset Energy Left
When changing batteries, the remaining battery life is initialized by Reset Energy Left parameter.
1. On/Off of display When “Enable” in LCD Mode is selected, the
LCD displays a set of screens to be shown and turns off for the specied time based on LCD Intermittent Time, and the display keeps the cycle repeatedly. Not selecting this parameter turns the LCD off.
2. On/Off of continuous display mode When “Enable” is set to LCD Mode and zero is
set to LCD Intermittent Time, the LCD displays continuously.
3. On/Off of bar graph Select “LCD Bargraph ON” in LCD Mode when
the bar graph is required.
When the wireless connection process is in the status of “ready,” “pause,” or “join,” the LCD display stays on regardless of the status in LCD Mode.
IM 01C27H01-01EN
<7. Setting Parameters>

7.3.6 Range Change

NOTE
When the device detects AL01 and AL02, the LCD display stays on regardless of the status in LCD mode. See Table 8.3 and 8.4 Error Message Summary for details.

7.3.4 Tag and Device Information

If these are specied when ordering, the designated Tag No. and device information are set and shipped. Tag No. and device information can be checked as follows.
• Procedure to call up the tag No. and device information
- Device Tag ( Software Tag ) This is specied when writing characters (up
to 16 characters) of ampliers TAG that differ from characters specied in Tag No.
Refer to section 7.4 “Connection to the Field
Wireless Network” for conrmation.
- Tag Description This is a universal parameter to store the
comment that describes the content of the tag located in the TRANSDUCER and AI blocks.
The AI1, AI2, and AI3 blocks of the AI blocks
correspond to the differential pressure, static pressure, and temperature, respectively.
The range values are factory-set as specied by the customer. To change the range, follow the steps below. The measurement span is determined by the upper and lower range values. In this method, the upper and lower range values can be set independently, and the span changes according to the range limit values sent to the transmitter.
• Procedure to call up the PV Range display. AI1, AI2 block : PV Range
Select the AI1 block for the differential pressure
and the AI2 block for the static pressure, then select “EU at 0%” and “EU at 100%” displayed in the PV Range parameters, and input the lower range and upper range values for the range, respectively.

7.3.7 Output Mode

The output mode of the output signal can be set as No Linearization or Sq root.
• Procedure to call up the Linearization Type display
AI1, AI2 block : Linearization Type
Select the AI1 block for the differential pressure
and the AI2 block for the static pressure, and then select No Linearization or Sq root for the Linearization Type parameter.
7-18
• When changing the device information, input the information based on the following limitation on the number of characters.
- Message function (up to 32 characters) TRANSDUCER block : Tag Description AI1-AI3 block : Tag Description

7.3.5 Unit

The unit parameter is set at the factory before shipment if specied at the time of order. Follow the procedure below to change the unit parameter.
• Procedure to call up the Unit display (Units Index)
Al1 - Al3 block : Scale. Units Index
To change the Unit display, choose desired
unit among the list of displayed unit selecting AI1 block as for the differential pressure, AI2 as for the static pressure and AI3 block as for temperature in the AI blocks.
IM 01C27H01-01EN
<7. Setting Parameters>
[ sq root output ]
Low
7-19

7.3.8 Output Signal Low Cut Mode Setup

Low cut mode can be used to stabilize the output signal near the zero point. ( There is 10% of hysteresis at only point of transition from low to high.)
[Setup Low Cut Value]
• Procedure to call up the Lower cutoff* display
AI1 block: Lower cutoff*
Example: setup LOW_CUT of output to 15%
Lower cutoff* = (“Eu at 100%” - “Eu at 0%”) × 0.15 + “Eu at 0%”
*: “Low Cutoff” is used instead of “Lower cutoff” for
[Setup Low Cut Mode]
Detachable antenna type (Amplier housing code: 8 or
9).
• Procedure to call up the Low Cut Mode display
AI1 block: Low Cut Mode
Example:Low cut at 20%
For low cut in Linear mode For low cut inzero mode
(%)
50
Output
20
Example: Low cut 20%
0 50 (%)
Input
(%)
50
Output
20
Example: Low cut 20%
0 50 (%)
Input
The low cut point has hysterisis so that the output around the point is behaved as below gure.
<Example>
Output mode: Linear Low cut mode: Zero
Low cut: 20.00%
cut point
2%
Hystrersis fixed at 10% of the cut point
F0705.ai
(20%)
0%
Output
Input
Setting range: 0 to 20%

7.3.9 Impulse Line Connection Orientation Setup

This function reverses the impulse line orientation.
Follow the procedure below to assign the high pressure impulse line connection to the L side of the transmitter.
• Procedure to call up the H/L Swap display TRANSDUCER block : H/L Swap
Select Reverse among two choices ( Normal /
Reverse) in a H/L Swap parameter.
Normal is chosen at the time of shipment.
[ Linear output ]
For low cut in Linear mode
(%)
50
Output
20
0 50 (%)
Example: Low cut 20%
Input
Figure 7.3 Low Cut Mode

7.3.10 Integral Indicator Display Mode

It is easy to check on the LCD whether Non Linearization or Sq root is set in the Linearization Type parameter selected in the output mode for the output signal. When Linear is set in the Linearization Type parameter, “√” is displayed on the integral indicator.
F0704.ai
IM 01C27H01-01EN
<7. Setting Parameters>
7-20

7.3.11 Integral Indicator Scale Setup

The following three displays are available for the integral indictor: differential pressure, static pressure, and temperature. The following three variables can be displayed on the integral indicator: % of differential pressure range, % of static pressure range, and % of temperature range.
Available displays
% of range
(PRES %)
% of static pressure range (SP %)
*1: Available for differential pressure transmitter.
*1
Indicates input pressure in –10 to 110% range depending on the set range (LRV and URV).
PRES % 45.6 %
Indicates input static pressure in –10 to 110% range depending on the set range (SP LRV and SP URV).
SP % 52.6 %
Follow the procedure described in (1) to (2) below to set the integral indicator.
(1) Display Selection
Description
and related parameters

7.3.12 Unit for Displayed Temperature

When the instrument is shipped, the temperature units are set to C (Centigrade). Follow the procedure below to change this setting.
• Procedure to call up the Sensor Range.Units Index display
AI3 block : Sensor Range.Units Index
Conrm that °C(deg C) is selected in the
Sensor Range.Units Index parameter for the temperature (AI3 block).
Note: When the unit is changed by Sensor Range.Units Index
parameter in temperature ( Al3 block) , units of capsule temperature is also changed.

7.3.13 Unit for Displayed Static Pressure

Follow the procedure to change the static pressure unit. Changing this parameter also changes the unit for the static pressure display.
• Procedure to call up the PV Range.Units Index display
AI2 block : PV Range.Units Index
Conrm that KPa is selected in the PV Range.
Units Index parameter for the static pressure (AI2 block).
Display set to Display Selection is displayed on the integral indicator.
• Procedure to call up the Display Selection display
TRANSDUCER block : Display Selection
The Display Selection parameter enables the
differential pressure (AI1 block), static pressure (AI2 block), and temperature (AI3 block) to be displayed on the LCD. Select whether or not to enable each block to be displayed
(2) Cyclic Display
Information in the AI1 to AI3 blocks can be displayed cyclically according to the display On/Off setting for the differential pressure (AI1 block), static pressure (AI2 block), and temperature (AI3 block) selected in the Display Selection parameter.
Monitoring the high or low static pressure of the capsule depends on the setting of parameter ‘SP Select.’
• Procedure to call up the SP Select display AI2 block : SP Select
Select High or Low in the SP Select parameter
for the static pressure (AI2 block).
Type of static pressure is set Absolute pressure (Abs) at shipment.
When changing monitoring type of static pressure, Follow below procedure.
• Procedure to call up the Static Press Type display
AI2 block : Static Press Type
Select gauge pressure (Gauge) or absolute
pressure (Abs) in the Static Press Type parameter for the static pressure (AI2 block).
IM 01C27H01-01EN
<7. Setting Parameters>
DPharp span: 0~25.00 kPa
7-21

7.3.14 Zero Point Adjustment and Span Adjustment

Each EJX-B Series Differential Pressure/Pressure Transmitter is characterized by factory. But there are some errors caused by environment and installed posture.
There are Zero and Span Adjustments to ne-tune those errors. Zero Adjustment is adjustment for one point to adjust the bottom value of the measurement range as 0 % of output.
.
The Span Adjustment denes input and output characteristic between two points that’s one side assumed as standard. This is used when there is doubt of span drift or when it is impossible to make zero at absolute pressure with adjustment for user’s pressure standard.
(1) Zero Point Adjustment
a. To set 0% at current input, perform
following procedure.
This method is used only when the pressure at bottom of measurement range is zero.
• Procedure to call up the lower limit adjustment parameter (Calibration Lowest Point).
AI1 block : Calibration Lowest Point
Set 0 to Calibration Lowest Point parameter for
differential pressure (Al1 block).
• Procedure to call up the calibration adjustment parameter (Cal Cmd).
AI1 block : Cal Cmd : CAL_LOW
Lower limit is changed by using Cal Cmd
parameter for differential pressure (Al1 block).
• Procedure to call up the calibration status parameter (Cal Status).
AI1 block : Cal Status
b. To match current input and output value,
follow procedure
Like tank level measurement that is impossible to set actual level to zero, output value is adjustment to actual level by other measurement using glassgage.
Example: Differential Pressure and Pressure
Transmitter’s span is 0 to 25.00kPa, current level is 13.50kPa, current output is 13.83kPa.
• Procedure to call up the lower limit adjustment parameter (Calibration Lowest Point).
AI1 block : Calibration Lowest Point
.
Set the actual level value of 13.50 kPa to the
Calibration Lowest Point parameter for the differential pressure (AI1 block). Apply an actual input and conrm the value specied in Calibration Lowest Point as the output value.
• Procedure to call up the calibration adjustment parameter (Cal Cmd).
AI1 block : Cal Cmd : CAL_LOW
The present output is changed from 13.83 kPa
to 13.50 kPa in CAL_LOW of the differential pressure (AI1 block) Cal Cmd parameter.
• Procedure to call up the calibration status parameter (Cal Status).
AI1 block : Cal Status
Conrm the value of CAL_SUCCESS (1) using
the Cal Status parameter.
Actual level: 13.50 kPa Transmitter output: 13.83 kPa
25.00 kPa
Actual level
13.50 kPa
0.00 kPa
Conrm the calibration status of CAL_
SUCCESS(1) using the Cal Status parameter.
DPharp
F0706.ai
Figure 7.4 Tank level measurement
IM 01C27H01-01EN
<7. Setting Parameters>
7-22
c. Using External Zero-adjustment Screw
External Zero-adjustment parameter (External Zero Trim) can set permission or prohibition to adjustment by External Zero-adjustment Screw.
Set “Trim on” to use the External Zero-adjustment Screw. (“Trim on” at shipment)
Use a slotted screwdriver to turn the zero­adjustment screw. Equalize the transmitter, then turn the screw clockwise to increase the output or counterclockwise to decrease the output. The zero point adjustment can be made with a resolution of 0.01% of the setting range. The degree of zero adjustments varies with the screw turning speed; turn the screw slowly to make a ne adjustment, quickly to make a rough adjustment.
• Procedure to call up the calibration adjustment parameter (Cal Cmd).
AI1 block : Cal Cmd : CAL_LOW
Conrm the lower limit of the measurement
range in CAL_LOW of the differential pressure (AI1 block) Cal Cmd parameter.
• Procedure to call up the calibration status parameter (Cal Status).
AI1 block : Cal Status
Conrm the value of CAL_SUCCESS (1) using
the Cal Status parameter.
• Procedure to call up the upper limit adjustment parameter (Calibration Highest Point).
AI1 block : Calibration Highest Point
Set the upper limit adjustment value for the
differential pressure (AI1 block) Calibration Highest Point parameter. Apply a reference pressure corresponding to the upper limit of the measurement range to the differential pressure/ pressure transmitter and conrm the reference pressure when it has stabilized.
Zero-adjustment Screw
F0707.ai
Figure 7.5 Zero-adjustment Screw
(2) Span Adjustment
Span Adjustment is function to change the input and output characteristic that assumed the bottom value (zero point) of measurement range a standard. Therefore, perform span adjustment (adjustment of the upper limit value) after zero adjustment (adjustment of bottom limit value).
After adding the pressure at point of adjustment and setting pressure value as parameter, the transmitter calculates quantity of adjustment and performs adjustment automatically.
• Procedure to call up the lower limit value parameter (Calibration Lowest Point).
AI1 block : Calibration Lowest Point
Set the lower limit adjustment value on the
differential pressure (AI1 block) Calibration Lowest Point parameter screen. Apply a reference pressure corresponding to the lower limit of the measurement range to the differential pressure/pressure transmitter and conrm the reference pressure when it has stabilized.
• Procedure to call up the calibration adjustment parameter (Cal Cmd).
AI1 block : Cal Cmd : CAL_HIGH
Conrm the upper limit of the measurement
range in CAL_HIGH of the differential pressure (AI1 block) Cal Cmd parameter.
• Procedure to call up the calibration status parameter (Cal Status).
AI1 block : Cal Status
Conrm the value of CAL_SUCCESS (1) using
the Cal Status parameter.
(3) Adjustments for Static Pressure
For the EJX differential transmitters, zero point and span adjustments of static pressure is performed in the same way as with the primary process variable (PV). Adjustment should be performed using the static pressure (AI2 block) Cal Cmd parameter. After calibration, conrm the status by using the static pressure (AI2 block) Cal Status.
• Procedure to call up the calibration adjustment parameter (Cal Cmd).
AI2 block : Cal Cmd Perform differential pressure zero/span adjustment before static pressure zero/span adjustment.
IM 01C27H01-01EN
<7. Setting Parameters>
7-23
(4) Reset Adjustment
Reset Adjustment clear the amount of adjustment. Reset Ajustment can be performed using CAL_ CLEAR of the differential pressure (AI1 block) Cal Cmd parameter for the input pressure and using CAL_CLEAR of the static pressure (AI2 block) Cal Cmd parameter for the static pressure. After Reset Adjustment, conrm the status by using Cal Status of the cleared block. The amount of adjustment made by the external zero-adjustment screw can be reset to the initial setting as well.
• Procedure to call up the calibration adjustment parameter (Cal Cmd).
AI1, AI2 block : Cal Cmd : CAL_CLEAR

7.3.15 Software Write Protect

Hardware write protection and software write protection functions are available for this transmitter.
• Procedure to call up the protection setting parameter (UAP Option)
UAPMO block : UAP Option
The following settings can be congured in the
UAP Option parameter.
- Setting to enable or disable changing
the setting to the Diagnostic Switch and Diagnostic Conguration parameters.
- Setting to enable or disable the hardware
write protection switch.
- Setting to enable or disable software write
protection.
• Procedure to call up the protection setting display parameter (Hardware Write Protect)
UAPMO block : Hardware Write Protect
The Hardware Write Protect parameter enables
the switch status of hardware write protection to be displayed.
For the relationship between hardware write
protection and software write protection, refer to section 9. “Parameter Summary.”

7.3.16 Switching to Deep Sleep Mode

• Procedure to call up the switch-to-deep-sleep parameter
TRANSDUCER block : Special Cmd
Set Deep Sleep mode(Standby) to the Special
Cmd parameter for the TRANSDUCER block. To start from deep sleep mode, either remove and insert the battery pack, or using the provisioning device tool or the device conguration tool via infrared communication.
CAUTION
After setting the deep sleep mode by infrared device conguration tool, keep the infrared port of device away from any other infrared signals.
NOTE
• Transmitter becomes the stop state after setting deep sleep mode and cannot reply any request from the device conguration tool via wireless communication.
• For this reason, there is the case that an error is display on the device conguration tool via wireless communication.
• To wake up from deep sleep mode, please pull battery pack and wait more than 30 seconds before attaching battery pack.

7.3.17 Switching to Silence Mode

This is a function to pause the instrument when it cannot join the eld wireless network after a specied time has elapsed. This function is effective in conserving battery power when, for example, the installation of the eld wireless integrated gateway is delayed compared to that of eld wireless devices. The default value is 28800 seconds (8 hours). Thereafter, a cycle of a one-hour pause and six-minute search is repeated until the instrument can join the eld wireless network.
• Procedure to call up the switch-to-silence parameter (Radio Silence)
UAPMO block : Radio Silence
When the instrument will not be used for a long time, switch the instrument to deep sleep mode to conserve battery power. To switch to deep sleep mode, follow the procedure below.
Set 0 to 231 seconds for the Radio Silence
parameter of the UAPMO block. If 0 is set, the Radio Silence parameter is invalid. To start from deep sleep mode, either remove and insert the battery pack, or use the provisioning device tool or the device conguration tool via infrared communication.
IM 01C27H01-01EN
<7. Setting Parameters>
7-24

7.4 Self-Diagnostics

UAPMO block: Diagnostic Status
Any of the four categories (Check function,
7.4.1 Identify Problems by Using the Device Conguration Tool
First, check Diagnostic Status of the self-diagnostic result.
Table 7.3 Diagnostic Status
Bits
Bit31 (MSB) F: Failure status --­Bit30 C: Function check status --­Bit29 O: Out of specication status --­Bit28 M: Maintenance required status --­Bit27 Faults in electronics F Bit26 Faults in sensor or actuator element F Bit25 Installation, calibration problem C Bit24 Out of service C Bit23 Outside sensor limits O Bit22 Environmental conditions out of device specication O Bit21 Fault prediction: Maintenance required M Bit20 Power is critical low: maintenance need short-term M Bit19 Power is low: maintenance need mid-term M Bit18 Software update incomplete C Bit17 Simulation is active C Bit16** Faults due to process inuence F Bit15** Faults due to non-compliance with specied operating conditions F Bit14** Other faults F Bit13-Bit08 reserved by WCI --­Bit07-Bit01 vendor specic area --­Bit00 Detail information available
1: available 0: no available
Contents
Maintenance required, Failure, and Off specication) according to NAMUR NE107* is supplied to Diagnostic Status of each diagnostic result.
Example
NAMUR NE107
Categorization
---
Checking the Diagnostic Status category allows taking the proper action. The Diagnostic Status contents are common for all ISA devices, and the setting for the Diagnostic Status category can be changed. For further details, refer to Diagnostic Status Detail. In Diagnostic Status Contents that can be diagnosed by the EJX, the alert category set in Out of Service can be changed to Check function. To do so, follow one of the procedures below.
a) UAPMO block: UAP Option, select enable. b) UAPMO block: Diagnostic Conguration,
change Out of Service from Failure to Check function.
c) UAPMO block: UAP Option, select disable.
The contents of diagnostic status are dened either valid or invalid at Diagnostic Switch parameter. Follow the example below to change “Out of Service” to invalid.
a) UAPMO block: UAP Option, select enable. b) UAPMO block: Diagnostic Switch, turn ON
Turn off “Out of Service”. Out of Service.
c) UAPMO block: UAP Option, select disable.
Note: Be careful when changing the alert category and turning
detection on and off as described above. Be sure to set UAP OPTION to disable again to prevent setting errors.
*: NAMUR NE107 “Self-Monitoring and Diagnosis of
Field Devices”
In Diagnostic Conguration setting, select one from the
followings; F: Failure status, C: Function check status, O: Out of specication status, or M: Maintenance required status.
**: Applicable for Detachable antenna type (Amplier
housing code: 8 or 9).
IM 01C27H01-01EN
<7. Setting Parameters>

7.4.2 Alert Report

EJX generates alert information related to Diagnostic Status and automatically sends to a eld wireless gateway. To use this function, the following alert setting is necessary. When “Out of Service” for Diagnostic Status alert is required, choose “FALSE” for [Out of Service.Alert Disable] in the UAPMO block. Refer to the eld wireless gateway User’s Manual for the setting procedure to obtain the alert information from the gateway. The alert report consists of the list of parameter names as shown Table 7.4 below.
Table 7.4 Contents of Alert Report
Parameter name Description DetectObjectTLPort Alert detection port UAP (0xF0B2)
xed
DetectObject Alert detection block UAPMO (1)
xed DetectTime Time stamp AlertDirection 1: generated, 0: clear AlertPriority Alert priorities set by users AlertType Alert types, see 8.4 Self-
Diagnostics AlertValue NAMUR107 category
0:Failure, 1:checkFunction,
2:OffSpec, 3:MaintenaceRequired
7-25
CAUTION
For a wireless gateway which does not support the alert report function, the alert setting in UAPMO block for the transmitter must be set to “Disable.” Note that YFGW710 eld wireless integrated gateway does not have the alert report function.
IM 01C27H01-01EN
<7. Setting Parameters>
Table 7.5 Diagnostic Results Summary
7-26
Diagnostic Status
Contents
Alert Type
Faults in electronics 78 F
Faults in sensor or actuator element
Installation, calibration problem
77 F
76 C
Out of service 75 O
Outside sensor limits 74 C
Environmental conditions out of device specication.
73 O
NAMUR
NE107
Category
Diagnostic Status Detail Description
AMP_T_SENSOR_FAIL* Amplier temperature sensor failure AMP_EEPROM_FAIL Amplier EEPROM failure AMP_EEP_IRREGULAR AMP EEPROM version not correct G_A_COMM_FAIL G/A failure FC_DELTA_T_FAIL C-side delta T circuit failure FR_DELTA_T_FAIL R-side delta T circuit failure
WL_AD_FAIL
Battery voltage not detected (AMP
failure) FC_SENSOR_FAIL C sensor frequency failure FR_SENSOR_FAIL R sensor frequency failure CAP_T_SENSOR_FAIL Capsule temperature sensor failure CAP_EEPROM_FAIL Capsule EEPROM failure CAP_EEP_IRREGULAR CAP EEPROM version not correct FC_UNOSC_FAIL C sensor oscillation stop failure FR_UNOSC_FAIL R sensor oscillation stop failure
DP_TRIM_SPAN_OUTSIDE
DP_TRIM_ZERO_OUTSIDE
SP_TRIM_SPAN_OUTSIDE
SP_TRIM_ZERO_OUTSIDE
"Pressure span adjustment variable
outside of range"
"Pressure zero adjustment variable
outside of range"
"Static pressure span adjustment
variable outside of range"
"Static pressure zero adjustment
variable outside of range" LCD_OUTSIDE_LIMIT LCD display outside of limits AI1_OUT_OF_SERVICE AI1 O/S mode AI2_OUT_OF_SERVICE AI2 O/S mode AI3_OUT_OF_SERVICE AI3 O/S mode DP_OUTSIDE_LIMIT Pressure outside of range SP_OUTSIDE_LIMIT Static pressure outside of range CAPT_OUTSIDE_LIMIT Capsule temperature outside of range AMPT_OUTSIDE_LIMIT Amplier temperature outside of range DP_OUTSIDE_RANGE Pressure setting outside of range
SP_OUTSIDE_RANGE
Static pressure setting outside of
range
Power is critical low: maintenance need short­term.
Power is low: maintenance need mid-term
71 M
70 M WL_LOWBAT_ALM Low battery
WL_DEEPSLP_ALM * Deep sleep due to low battery
CRITICAL_LOWBAT ** Deep sleep due to low battery
AI1_SIMULATION_ACTIVE AI1 Simulation mode
Simulation is active 68 C
AI2_SIMULATION_ACTIVE AI2 Simulation mode AI3_SIMULATION_ACTIVE AI3 Simulation mode
Not applicable for the diagnostic regarding AI2 object and static pressure measurement. *: Applicable for Integral antenna type (Amplier housing code: 7). **: Applicable for Detachable antenna type (Amplier housing code: 8 or 9).
IM 01C27H01-01EN
<7. Setting Parameters>

7.4.3 Checking with Integral Indicator

NOTE
If an error is detected by running self-diagnostics, an error number is displayed on the integral indicator. If there is more than one error, the error number changes at three-second intervals. See Table 8.3 regarding the error codes.
F0708.ai
Figure 7.6 Integral Indicator
7-27
IM 01C27H01-01EN
<8. Maintenance>

8. Maintenance

8-1

8.1 Overview

WARNING
Since the accumulated process uid may be toxic or otherwise harmful, take appropriate care to avoid contact with the body or inhalation of vapors when draining condensate or venting gas from the transmitter pressure-detector section and even after dismounting the instrument from the process line for maintenance.
Maintenance of the transmitter is easy due to its modular construction. This chapter describes the procedures for calibration, adjustment, and the disassembly and reassembly procedures required for component replacement.
Transmitters are precision instruments. Please carefully and thoroughly read the following sections for information on how to properly handle them while performing maintenance.
IMPORTANT
• As a rule, maintenance of this transmitter should be done in a maintenance room that has all the necessary tools.
• The CPU assembly, RF assembly and integral indicator contain sensitive parts that can be damaged by static electricity.
Take precautions such as using a grounded
wrist strap when handling electronic parts or touching the board circuit patterns. Also be sure to place the removed CPU assembly, RF assembly and integral indicator into a bag with an antistatic coating.

8.2 Calibration Instruments Selection

Table 8.1 lists the instruments that can be used to calibrate a transmitter. When selecting an instrument, consider the required accuracy level. Exercise care when handling these instruments to ensure they maintain the specied accuracy.

8.3 Calibration

Use the procedure below to check instrument operation and accuracy during periodic maintenance or troubleshooting.
1) Insert the battery pack and then perform provisioning to have the transmitter join the eld wireless network or preparing the infrared communication for calibration.
2) Set measurement mode to continuous using the eld device conguration tool and the update period to 1 second using the eld wireless conguration tool.
3) Connect the devices as shown in Figure 8.1 and allow the transmitter to warm up for at least 5 minutes.
IMPORTANT
If the measurement range 0% point is 0 kPa or shifted in the positive direction (suppressed zero), the reference pressure should be applied as shown in the gure. If the measurement range 0% point is shifted in the negative direction (elevated zero), the reference pressure should be applied using a vacuum pump.
4) Apply reference pressures of 0%, 50%, and 100% of the measurement range to the transmitter. Calculate the errors (differences between the device conguration tool readings and reference pressures) as the pressure is increased from 0% to 100% and is decreased from 100% to 0%, and conrm that the errors are within the required accuracy.
(Note) When the output mode is set to “Sg root,” apply reference
pressures of 0, 6.25, 25, 56.25, and 100% instead.
5) When the test is nished, reset measurement mode and update time to the initial value using the eld device conguration tool and the eld wireless conguration tool.
IM 01C27H01-01EN
<8. Maintenance>
Table 8.1 Instruments Required for Calibration
Name Yokogawa-recommended Instrument Remarks
Provisioning device tool
• FieldMate (R2.02.01 or later)
• Provisioning Device Tool
• Infrared Adapter certied by Yokogawa Supplier: ACTiSYS Product name: IrDA InfraRed USB Adaptor
Product number: IR224UN Field wireless conguration tool
• Field Wireless Integrated Gateway attached Software Field Wireless Congurator Field Wireless Management Tool
• Field Wireless System related Product Plant Resource Manager (PRM) (R3.05 or later)
• Device Conguration Tool via Wireless Communication FieldMate(R2.02.01 or later) DeviceFile(R3.01.01 or later)
• Device Conguration Tool via Infrared Communication FieldMate(R2.03.00 or later) DeviceFile(R3.02.01 or later)
Digital manometer
Model MT220 precision digital manometer
1) For 10 kPa class Accuracy: ±(0.015% of rdg + 0.015% of F.S.) for 0 to 10 kPa
Select a manometer having a pressure range close to that of the transmitter.
±(0.2% of rdg + 0.1% of F.S.). . . . . . . . for -10 to 0 kPa
2) For 130 kPa class
Accuracy: ±0.02% of rdg . . . . . . . . . . . . . . . . . . . . for 25 to 130 kPa
±5digits. . . . . . . . . . . . . . . . . . . . . . . . . for 0 to 25 kPa
±(0.2% of rdg + 0.1% of F.S.). . . . . . . . for -80 to 0 kPa
3) For 700 kPa class
Accuracy: ±(0.02% of rdg + 3digits) . . . . . . . . . . . for 100 to 700 kPa
±5 digits . . . . . . . . . . . . . . . . . . . . . . . . for 0 to 100 kPa
±(0.2% of rdg + 0.1% of F.S.). . . . . . . . for -80 to 0 kPa
4) For 3000 kPa class
Accuracy: ±(0.02% of rdg + 10 digits). . . . . . . . . . for 0 to 3000 kPa
±(0.2% of rdg + 0.1% of F.S.). . . . . . . . for -80 to 0 kPa
5) For 130 kPa abs class
Accuracy: ±(0.03% of rdg + 6 digits). . . . . . . . . . . for 0 to 130 kPa abs
Pressure generator
Model MC100 pneumatic pressure standard for 200 kPa {2 kgf/cm kPa {2500 mmH
2O}
2
}, 25
Requires air pressure supply.
Accuracy: ±0.05% of F.S.
Dead weight gauge tester 25 kPa {2500 mmH
Accuracy: ±0.03% of setting
2O}
Select the one having a pressure range close to that of the transmitter.
Pressure source
Model 6919 pressure regulator (pressure pump)
Pressure range: 0 to 133 kPa {1000 mmHg}
Prepare the vacuum pump for negative pressure ranges.
Note: The above table contains the instruments capable of performing calibration to the 0.2% level. Since special maintenance and
management procedures involving traceability of each instrument to higher-level standards are required for calibration to the 0.1% or higher level, there may be difculties in calibration to this level in the eld. For calibration to the 0.1% level, contact Yokogawa representatives from which the instrument was purchased or the nearest Yokogawa ofce.
High pressure side diaphragm seal
Mating calibration flange
Reference
pressure
Pressure
gauge
P
If a pressure source and a manometer are combined:
Supply
P
Pressure generator
pressure
If a pressure generator is used:
Pressure source
8-2
Low pressure side diaphragm seal
Figure 8.1 Instrument Connections
F0801.ai
IM 01C27H01-01EN
<8. Maintenance>

8.4 Disassembly and Reassembly

CAUTION
Precautions for the intrinsic safety explosion prevention type instrument
Intrinsic safe type transmitters must be, as a rule, removed to a non-hazardous area for maintenance and be disassembled and reassembled to the original state. Check and conrm the insulation when it is reassembled to the original state. Check and conrm the insulation when it is reassembled to the original state. Refer to section 2.7 “Insulation Resistance and Dielectric Strength Test” for details of Resistance Test.
IMPORTANT
• Perform the provisioning when replacing the RF assembly. Refer to 6.4 Connecting to the Field Wireless Network for details.
• Replace the batteries and perform the parameter settings when replacing the CPU assembly. Refer to 8.4.5 Replacing the Batteries.
Always remove Battery pack and shut off pressures before disassembly and assembly. Use proper tools for all operations.

8.4.1 Replacing the Integral Indicator

This subsection describes the procedure for replacing an integral indicator. (See gure 8.2)
Removing the Integral Indicator
1) Remove the cover.
2) While supporting the integral indicator with one
3) Dismount the integral indicator from the RF
When doing this, carefully pull the integral
Attaching the Integral Indicator
1) Align both the integral indicator and RF
2) Insert and tighten the two mounting screws.
3) Replace the cover.
CAUTION
hand, loosen its two mounting screws.
assembly.
indicator straight forward so as not to damage the connector pins between it and the RF assembly.
assembly connectors and engage them.
Power cable
8-3
This section describes procedures for disassembly and reassembly for maintenance and component replacement.
Table 8.2 shows the tools required.
Table 8.2 Tools for Disassembly and Reassembly
Tool Quantity Remarks
Phillips screwdriver
Slotted screwdriver
Allen wrenches 3 JIS B4648
Wrench 1 Width across ats, 17 mm Torque wrench 1 Adjustable
wrench Socket wrench 1 Width across ats, 16 mm Socket driver 1 Width across ats, 5.5 mm Tweezers 1
1 JIS B4633, No. 2
1
One each, nominal 3, 4 and 2.5 mm Allen wrenches
1
Press Forward
Stud
Integral indicator
CPU assembly
RF assembly
Mounting screw
Amplifier cover
Figure 8.2 Removing and Attaching Integral
indicator, RF assembly and CPU Assembly
Boss
Zero adjustment screw
Zero-adjustment screw pin
F0802.ai
IM 01C27H01-01EN
<8. Maintenance>
8-4

8.4.2 Replacing the RF Assembly

This subsection describes how to replace the RF assembly (see Figure 8.2).
Removing the RF assembly
1) Remove the cover.
2) Remove the integral indicator (refer to subsection 8.4.1).
3) Remove the two stud bolts by using a socket driver (width across ats: 5.5 mm).
4) Disconnect the RF assembly from the CPU assembly. When doing this, carefully pull the RF assembly straight forward so as not to damage the connector pins between it and the CPU assembly.
5) Disconnect the antenna cable that connects the RF assembly and the antenna.
NOTE
Be careful not to apply excessive force to the RF assembly and the connector of the antenna cable when removing it.
4) Use a socket driver (width across ats, 5.5 mm) to loosen the two bosses.
5) Carefully pull the CPU assembly straight forward to remove it.
6) Disconnect the at cable (cable with white connector at the end) that connects the CPU assembly and the capsule.
NOTE
Be careful not to apply excessive force to the CPU assembly when removing it.
Mounting the CPU assembly
1) Connect the at cable (with white connector) between the CPU assembly and the capsule.
2) Connect the power cable (with brown connector) to the CPU assembly.
NOTE
Make certain that the cables do not get pinched between the case and the edge of the CPU assembly.
Mounting the RF assembly
1) Connect the antenna cable between the RF assembly and the antenna.
2) Align both the RF assembly and CPU assembly connectors and engage them.
3) Tighten the two stud bolts.
4) Mount the integral indicator (refer to subsection
8.4.1).
5) Replace the cover.

8.4.3 Replacing the CPU Assembly

This subsection describes how to replace the CPU assembly (see Figure 8.2).
Removing the CPU assembly
1) Remove the cover.
Remove the integral indicator and the RF
assembly (refer to subsections 8.4.1 and 8.4.2).
2) Turn the zero-adjustment screw to the position as shown in Figure 8.2.
3) Disconnect the power cable (cable with brown connector at the end). When doing this, lightly press the side of the CPU assembly connector and pull the cable connector to disengage (see the upper left of Figure 8.2).
3) Align and engage the zero-adjustment screw pin with the groove on the bracket on the CPU assembly. Then insert the CPU assembly straight onto the post in the amplier case.
4) Tighten the two bosses. Mount the RF assembly, and the integral indicator (refer to subsections 8.4.1 and 8.4.2).
IMPORTANT
Conrm that the zero-adjustment screw pin is placed properly in the groove on the bracket prior to tightening the two bosses. If it is not, the zero­adjustment mechanism will be damaged.
5) Replace the cover.
IM 01C27H01-01EN
<8. Maintenance>
The battery pack mounting screws
8-5

8.4.4 Replacing the Battery Pack

Regarding the transmitter with intrinsically safe approval, the battery pack can be replaced without removing the device in hazardous area.
Preparation
Initialize the remaining battery life by using the parameter of Reset Energy Left in UAPMO block. When the battery power is burned and emptied, initialize the remaining battery after prompt replacement of the battery pack.
Removing
1) Remove the terminal box cover.
2) Loosen the two battery pack mounting screws (see Figure 8.3).
3) Pull out the Battery pack.
The battery pack mounting screws cannot be separated from the battery pack so as to prevent drop-off.

8.4.5 Replacing the Batteries

The batteries in the battery pack can be replaced. Batteries are not installed when shipped from the factory. Assemble the battery pack as follows.
WARNING
Be sure to replace the batteries or disassemble and assemble the battery pack in a safe location. Doing so in an explosive area could cause an explosion.
CAUTION
When replacing the batteries, be sure to replace the two batteries at the same time and do not use an old and a new battery together.
Disassembling
1) Loosen the two battery case mounting screws (Figure 8.4).
2) Separate the battery case into two parts.
3) Remove the old batteries.
F0803.ai
Figure 8.3 Removing the Battery Pack
Remounting
1) Insert the new battery pack lightly.
2) Push the center of the battery pack and insert it securely.
3) Tighten the two battery pack mounting screws to a torque of approximately 0.7 N·m.
4) Replace the terminal box cover.
Assembling
1) Insert new batteries into the battery case. Be careful of the orientation of the batteries.
2) Attach the two parts of the battery case to each other.
3) Tighten the two battery case mounting screws to a torque of approximately 0.7 N·m.
cannot be separated from battery pack so as to prevent drop-off.
F0804.ai
Figure 8.4 Removing the Battery Pack
IM 01C27H01-01EN
<8. Maintenance>
8-6

8.4.6 Handling Batteries

This battery pack uses two primary lithium/ thionyl chloride batteries. Each battery contains approximately 5 grams of lithium, for a total of 10 grams in each pack. Under normal conditions, the battery materials are self-contained and are not reactive as long as the batteries and the pack integrity are maintained. Care should be taken to prevent thermal, electrical or mechanical damage. Protect the electrode of the battery pack to avoid rapid electrical discharge. Discharged a battery may lead to uid leakage and excessive heat. Batteries should be stored in a clean and dry area. For maximum battery life, storage temperature should not exceed 30°C.
WARNING
Handling the battery pack The following precautions must be observed in order to safely and effectively use a battery pack. Improper use may lead to uid leakage, excessive heat, ignition, or explosion.
• Never charge it.
• Do not short-circuit it.
• Do not disassemble, transform, or modify it.
• Do not heat it or throw it into a re.
• Do not soak it in fresh water or seawater.
CAUTION
Transportation of products containing
lithium batteries:
Batteries used for this transmitter contain lithium. Primary lithium batteries are regulated in transportation by the U.S. Department of Transportation, and are also covered by the International Air Transport Association (IATA), the International Civil Aviation Organization (ICAO), and the European Ground Transportation of Dangerous Goods (ARD). It is the responsibility of the shipper to ensure compliance with these or any other local requirements. Consult current regulations and requirements before shipping. When transporting this transmitter with the battery pack inserted, keep it in deep sleep mode in order to conserve battery power. For details on how to switch to deep sleep mode, refer to subsection 7.3.16 “Switching to Deep Sleep Mode.”
How to replace and dispose of the
batteries:
This is an explanation about the new EU Battery Directive(DIRECTIVE 2006/66/EC). This directive is only valid in the EU. Batteries are used for this product. When you remove batteries from this product and dispose them, discard them in accordance with domestic law concerning disposal. Take a right action on waste batteries, because the collection system in the EU on waste batteries are regulated.
Battery type: Primary lithium-thionyl chloride battery
Observe the following precautions for the safe disposal of batteries.
• Do not incinerate the battery, and do not expose it to a high temperature of 100°C or more. This may lead to uid leakage or explosion.
• Dispose of the battery according to laws and regulations.
Use the following dedicated parts for the battery pack and batteries.
■ Battery Pack Part number: F9915NQ (with batteries) Part number: F9915NK (without batteries)
■ Batteries Part number: F9915NR Alternatively, Tadiran TL-5930/S batteries may
be purchased and used.
CAUTION
The symbol (see above), which is marked on the batteries, means they shall be sorted out and collected as ordained in ANNEX II in DIRECTIVE 2006/66/EC.
Procedure to remove the batteries safely:
Refer to subsection 8.4.6 “Replacing the Battery Pack” and subsection 8.4.7 “Replacing the Batteries.”
IM 01C27H01-01EN
<8. Maintenance>
8-7

8.5 Troubleshooting

If any abnormality appears in the measured values, use the troubleshooting ow chart below to isolate and remedy the problem. Since some problems have complex causes, these ow charts may not identify all. If you have difculty isolating or correcting a problem, contact Yokogawa service personnel.

8.5.1 Basic Troubleshooting

First determine whether the process variable is actually abnormal or a problem exists in the measurement system.
If the problem is in the measurement system, isolate the problem and decide what corrective action to take.
This transmitter is equipped with a self-diagnostic function which will be useful in troubleshooting, and the transmitter equipped with an integral indicator will show an alarm code as a result of self­diagnosis. See subsection 8.5.3 for the list of alarms. See also each communication manual.
: Areas where self-diagnostic offers support
Abnormalities appear in measurement.
YES
Inspect the
process system.
YES
Inspect receiver.
Environmental conditions
Is process variable
itself abnormal?
NO
Measurement system problem
Isolate problem in
measurement system.
Does problem exist in receiving instrument?
NO
Transmitter itself
Check/correct
environmental conditions.
Operating conditions
Check/correct operating
conditions.
Check transmitter.
Figure 8.5 Basic Flow and Self-Diagnostics
F0805.ai
IM 01C27H01-01EN
<8. Maintenance>
8-8

8.5.2 Troubleshooting Flowcharts

The following sorts of symptoms indicate that transmitter may not be operating properly.
Example : • There is no output signal.
• Output signal does not change even though
process variable is known to be varying.
• Output value is inconsistent with value
inferred for process variable.
Check display of the error code. Check self-diagnostics by the device configuration tool.
Does the self-diagnostic
indicate problem location?
NO
Is there any pressure leak?
NO
Refer to Alarm Message Summary in Subsection 8.5.3.
Fix pressure leaks, paying particular attention to connections for pressure-detector section.
YES
YES
Output travels beyond 0% or 100%.
Connect the device configuration tool and check self-diagnostics.
Does the self-
diagnostic indicate problem
location?
NO
Are high
and low pressure side
diaphragm seals correctly
connected to the
process?
YES
Is the liquid level as specified?
YES
Refer to Alarm Message Summary in Subsection 8.5.3
Correct the connections.
Use the transmitter within the measurement range shown on the data plate.
YES
NO
NO
Is the Field Wireless Network
setting correct?
YES
Contact Yokogawa service personnel.
Reconnect to the Field Wireless Network.
NO
F0806.ai
Is zero point
adjusted correctly?
YES
Contact Yokogawa service personnel.
Adjust the zero point.
NO
F0807.ai
IM 01C27H01-01EN
<8. Maintenance>
Large output error.
Connect the device configuration tool and check self-diagnostics.
8-9
Does the self-
diagnostic indicate the problem
differ between the high and low
location?
NO
Does
the ambient
temperature significantly
pressure side
capillaries?
NO
Are excess
capillaries secured?
YES
Is transmitter
installed where there is
marked variation in
temperature?
NO
Refer to Alarm Message Summary in Subsection 8.5.3
Bind capillaries together as far as possible or provide lagging.
Secure them so that they are not moved by wind or vibration.
Provide lagging and/or heat insulation, or allow adequate ventilation.
YES
YES
NO
YES
Were appropriate
instruments used for
calibration?
YES
Is output adjusted correctly?
YES
Contact Yokogawa service personnel.
Refer to 8.2 “Calibration Instruments Selection”.
Adjust the output.
NO
NO
F0808.ai
IM 01C27H01-01EN
<8. Maintenance>

8.5.3 Errors and Countermeasures

Table 8.3 Error Message Summary (Causes and Actions)
Release/ recovery
conditions
(except restart)
Recovers only when AUTO RECOVER is ON and within the range
when AUTO RECOVER is ON and oscillation does not stop
None
Recovers when returns to normal.
None
Recovers when returns to normal.
Recovers when input pressure returns within the range.
Recovers when static pressure returns within the range.
Recovers when temperature returns within the range.
Recovers when temperature returns within the range.
Integral
indicator
AL. 01 CAP. ERR
*2
AL. 02 AMP. ERR
*2
AL. 10 PRESS
AL. 11 ST. PRSS
AL. 12 CAP. TMP
AL. 13 AMP. TMP
Factory
NAMUR
category
F Bit 26
F Bit 27
O Bit 23
Bit
Diagnostic
Status
Faults in sensor or actuator element
Faults in electronics
Outside sensor limits
Diagnostic Status Detail Cause
FC_SENSOR_FAIL FR_SENSOR_FAIL
FC_UNOSC_FAIL Recovers only FR_UNOSC_FAIL
CAP_T_SENSOR_FAIL Capsule
CAP_EEPROM_FAIL Capsule
CAP_EEP_IRREGULAR None AMP_T_SENSOR_FAIL
AMP_EEPROM_FAIL
AMP_EEP_IRREGULAR None FC_DELTA_T_FAIL FR_DELTA_T_FAIL G_A_COMM_FAIL WL_AD_FAIL DP_OUTSIDE_LIMIT Pressure
SP_OUTSIDE_LIMIT Static pressure
CAPT_OUTSIDE_LMIT Capsule
AMPT_OUTSIDE_LIMIT Amplier
Pressure sensor failure
temperature sensor failure
EEPROM memory failure
*3
Amplier temperature sensor failure
Amplier EEPROM failure
Amplier failure None
outside of specied range
outside of specied range
temperature outside of range (-50 to 130°C)
temperature outside of range (-50 to 95°C)
8-10
Action
Replace the capsule.
Replace the amplier.
Check the input pressure.
Check the input pressure.
Retain heat or insulate so that temperature returns within the specied range.
Retain heat or insulate so that temperature returns within the specied range.
IM 01C27H01-01EN
<8. Maintenance>
8-11
Integral
indicator
AL.53 P. ADJ
AL.53 P. ADJ
AL. 55 SP. ADJ
AL. 55 SP. ADJ
AL. 79 OV. DISP
AL. 30 RANGE
AL. 31 SP. RNG
AL. 70 LOWBAT
AL. 70 LOWBAT
AL. 60 AI OOS
AL. 61 AI OOS
AL. 62 AI OOS
Factory
NAMUR
category
C Bit 25
C Bit 25
O Bit 22
M
C Bit 24 O/S
Bit
Bit 20
Bit 19
Installation, calibration problem
Installation, calibration problem
Environmental conditions out of device specication
Power is critical low: maintenance need short ­term
Power is low: maintenance need mid - term
Diagnostic
Status
Diagnostic Status Detail Cause
DP_TRIM_SPAN_OUTSIDE Pressure span
adjustment variable outside of range
DP_TRIM_ZERO_OUTSIDE Pressure zero
adjustment variable outside of range
SP_TRIM_SPAN_OUTSIDE Static pressure
span adjustment variable outside of range
SP_TRIM_ZERO_OUTSIDE Static pressure
zero adjustment variable outside of range
LCD_OUTSIDE_LIMIT LCD display
outside of specied range
DP_OUTSIDE_RANGE Input pressure
setting outside of range
SP_OUTSIDE_RANGE Static pressure
setting outside of range
WL_DEEPSLP_ALM
CRITICAL_LOWBAT
WL_LOWBAT_ALM Low remaining
AI1_OUT_OF_SERVICE AI1 block is O/S
AI2_OUT_OF_SERVICE AI2 block is O/S
AI3_OUT_OF_SERVICE AI3 block is O/S
*3
*4
Low remaining battery voltage results in switching to deep sleep.
Battery voltage is the lowest.
battery voltage
mode.
mode.
mode.
Release/ recovery
conditions
(except restart)
Recovers when span adjustment variable/point returns within the range.
Recovers when zero adjustment variable/point returns within the range.
Recovers when span adjustment variable /point returns within the range.
Recovers when zero adjustment variable/point returns within the range.
Recovers when display value returns within the range.
Recovers when setting returns within the range.
Recovers when setting returns within the range.
None
None
Returns when the mode target of AI1 block is other than O/S.
Returns when the mode target of AI2 block is other than O/S.
Returns when the mode target of AI3 block is other than O/S.
Action
Check the span adjustment variable for the Pressure.
Check the zero adjustment variable for the Pressure.
Check the static pressure span adjustment variable.
Check the static pressure zero adjustment variable.
Check the display setting.
Check the input pressure setting.
Check the static pressure setting.
Replace the batteries.
Replace the batteries.
Set the mode target to AUTO.
Set the mode target to AUTO.
Set the mode target to AUTO.
IM 01C27H01-01EN
<8. Maintenance>
8-12
Factory
Integral
indicator
AL. 63 AI SIM
AL. 64 AI SIM
AL. 65 AI SIM
*1: "Factory NAMUR category” refers to the four categories (C: Check function, M: Maintenance required, F: Failure, and O: Off
* NAMUR NE107 “Self-Monitoring and Diagnosis of Field Devices” *2: When the device detects “AL01 CAP.ERR” and “AL02 AMP.ERR”, the LCD display stays on regardless of the status in LCD mode. *3: Applicable for Integral antenna type (Amplier housing code: 7). *4: Applicable for Detachable antenna type (Amplier housing code: 8 or 9).
NAMUR
category
C Bit 17
C Bit 17
specication) according to NAMUR NE107*.
Bit
Diagnostic
Status
Simulation is active
Simulation is active
Diagnostic Status Detail Cause
SimulationActive (AI1)
SimulationActive (AI2)
SimulationActive (AI3)
AI1 block is simulate mode.
AI2 block is simulate mode.
AI3 block is simulate mode.
Release/ recovery
conditions
(except restart)
Returns when the simulate mode of AI1 block is set to disable. 1 (Disable)
Returns when the simulate mode of AI2 block is set to disable. 1 (Disable)
Returns when the simulate mode of AI3 block is set to disable. 1 (Disable)
Action
Check the simulate mode of AI1 block.
Check the simulate mode of AI2 block.
Check the simulate mode of AI3 block.
IM 01C27H01-01EN
<8. Maintenance>
Table 8.4 Error Message Summary (Output Actions)
Output actions
Static
Pressure
Output value (hold value) Output status (BAD: Sensor Failure)
Output value (hold value) Output status (BAD: Device Failure)
Output value (hold value) Output status (BAD: Device Failure)
Output value (hold value) Output status (BAD: Device Failure)
Capsule
Temp Value
Normal action
(calculated in a normal way) Output status (BAD: Sensor Failure)
Output value (calculated in a normal way) Output status (BAD: Device Failure)
Output value (calculated in a normal way) Output status (BAD: Device Failure)
Normal action
(calculated in a normal way) Output status (BAD: Device Failure)
Integral
Indicator
AL. 01 CAP. ERR
*2
AL. 02 AMP.ERR
*2
Factory NAMUR
Bit
category
F Bit 26
F Bit 27
Diagnostic
Status
Faults in sensor or actuator element
Faults in electronics
Diagnostic Status Detail
Pressure
FC_SENSOR_FAIL Output value FR_SENSOR_FAIL FC_UNOSC_FAIL FR_UNOSC_FAIL
(hold value) Output status (BAD: Sensor Failure)
CAP_T_SENSOR_FAIL Normal action Normal action Output value
CAP_EEPROM_FAIL Output value
(hold value) Output status
CAP_EEP_IRREGULAR
(BAD: Device Failure)
AMP_T_SENSOR_FAIL
*3
Normal action Normal action Normal action
AMP_EEPROM_FAIL Output value
(hold value) Output status
AMP_EEP_IRREGULAR
(BAD: Device Failure)
FC_DELTA_T_FAIL Output value
(hold value) output status
FR_DELTA_T_FAIL
(BAD: Device Failure)
Output value
G_A_COMM_FAIL Output value
(calculated in a normal way) Output status
WL_AD_FAIL
(BAD: Device Failure)
8-13
Amp Temp Value
Normal action
Output value (calculated in a normal way) Output status (BAD: Device Failure)
Output value (calculated in a normal way) Output status (BAD: Sensor Failure)
Output value
*4
(hold value) Output status (BAD: Device Failure)
Output value
*4
(hold value) output status (BAD: Device Failure)
Output value (calculated in a normal way) Output status (BAD: Device Failure)
IM 01C27H01-01EN
<8. Maintenance>
8-14
Integral
Indicator
AL. 10 PRESS
AL. 11 ST. PRSS
AL. 12 CAP. TMP
AL. 13 AMP. TMP
AL. 53 P. ADJ
AL. 53 P. ADJ
AL. 55 SP. ADJ
AL. 55 SP.ADJ
AL. 79 OV. DISP
Factory NAMUR
category
O Bit 23
C Bit 25
Bit
Diagnostic
Status
Outside sensor limits
Installation, calibration problem
Diagnostic Status Detail
DP_OUTSIDE_LIMIT Output value
SP_OUTSIDE_LIMIT Output value
CAPT_OUTSIDE_LIMIT Output value
AMPT_OUTSIDE_LIMIT
DP_TRIM_SPAN_ OUTSIDE
DP_TRIM_ZERO_ OUTSIDE
SP_TRIM_SPAN_ OUTSIDE
SP_TRIM_ZERO_ OUTSIDE
LCD_OUTSIDE_LIMIT
Pressure
(calculated in a normal way) Output status (UNCERTAIN: Sensor Conversion not Accurate)
(calculated in a normal way) Output status (UNCERTAIN: Non Specic)
(calculated in a normal way) Output status (UNCERTAIN: Non Specic)
Normal action Normal action Normal action
Output value (calculated in a normal way) Output status (UNCERTAIN: Range Limits Exceeded)
Output value (calculated in a normal way) Output status (UNCERTAIN: Range Limits Exceeded)
Normal action
Normal action
Normal action Normal action Normal action Normal action
Output actions
Static
Pressure
Output value (calculated in a normal way) Output status (UNCERTAIN: Non Specic)
Output value (calculated in a normal way) Output status (UNCERTAIN: Sensor Conversion not Accurate)
Output value (calculated in a normal way) Output status (UNCERTAIN: Non Specic)
Normal action Normal action Normal action
Normal action Normal action Normal action
Output value (calculated in a normal way) Output status (UNCERTAIN: Range Limits Exceeded)
Output value (calculated in a normal way) Output status (UNCERTAIN: Range Limits Exceeded)
Capsule
Temp Value
Normal action Normal action
Normal action Normal action
Output value (calculated in a normal way) Output status (UNCERTAIN: Sensor Conversion not Accurate)
Normal action Normal action
Normal action Normal action
Amp Temp Value
Normal action
Output value (calculated in a normal way) Output status (UNCERTAIN: Sensor Conversion not Accurate)
IM 01C27H01-01EN
<8. Maintenance>
8-15
Output actions
Static
Pressure
Capsule
Temp Value
Amp Temp Value
Integral
Indicator
AL. 30 RANGE
AL. 31 SP. RNG
Factory NAMUR
Bit
category
O Bit 22
Diagnostic
Status
Environmental conditions out of device specication
Power is
Diagnostic Status Detail
DP_OUTSIDE_RANGE
SP_OUTSIDE_RANGE
WL_DEEPSLP_ALM
*3
Pressure
Normal action Normal action Normal action Normal action
Normal action Normal action Normal action Normal action
critical
*6
AL. 70 LOWBAT
Bit 20
low: maintenance
CRITICAL_LOWBAT
Normal action Normal action Normal action Normal action
*4
need
*6
AL. 70 LOWBAT
M
Bit 19
short - term Power is
low: maintenance need
WL_LOWBAT_ALM
Normal action Normal action Normal action Normal action
mid - term
AI1_OUT_OF_SERVICE Output value
AL. 60 AI OOS
(hold value) Output status (BAD: Out of
Normal action Normal action Normal action
Service)
AL. 61 AI OOS
C Bit 24 O/S
AI2_OUT_OF_SERVICE
Normal action
Output value (hold value) Output status (BAD: Out of
Normal action Normal action
Service)
AL. 62 AI OOS
AL. 63 AI SIM
AL. 64 AI SIM
AL. 65 AI SIM
C Bit 17
Simulation is active
AI3_OUT_OF_SERVICE
SimulationActive (AI1)
SimulationActive (AI2)
SimulationActive (AI3)
Normal action Normal action
Normal action Normal action Normal action Normal action
Normal action Normal action Normal action Normal action
Normal action Normal action Normal action Normal action
Output value (hold value) Output status (BAD: Out of Service)
Output value (hold value) Output status (BAD: Out of Service)
*1: “Factory NAMUR category” refers to the four categories (C: Check function, M: Maintenance required, F: Failure, and O: Off
specication) according to NAMUR NE107*. * NAMUR NE107 “Self-Monitoring and Diagnosis of Field Devices” *2: When the device detects “AL01 CAP.ERR” and “AL02 AMP.ERR”, the LCD display stays on regardless of the status in LCD mode. *3: Applicable for Integral antenna type (Amplier housing code: 7). *4: Amplier temperature value is calculated in a normal way for Detachable antenna type (Amplier housing code: 8 or 9). *5: Applicable for Detachable antenna type (Amplier housing code: 8 or 9). *6: When the ambient temperature is higher than 60°C, AL.70 may be generated despite the indication of Energy Left shows sufciently
remained. However, it does not affect the device operation. This is caused by the change of battery inner status with extremely
low power consumption under high temperature environment. It is recommended to set the data updating period to 15 seconds or
shorter.
IM 01C27H01-01EN
<9. Parameter Summary>

9. Parameter Summary

Table 9.1 Parameter
Object
ID
1. UAPMO block
Attribute
ID
1 Version Revision Indicates the application revision of EJX This revision
10 Static Revision Indicates the revision level of the xed parameters of
64 Identication
65 CTS Version Indicates the version of the communication stack test
66 ITS Version Indicates the version of the inter operability test system
67 Diagnostic Status Indicates the diagnostic results of the device based on
68 UAP Option Allows setting the Diagnostic Status and write protection
69 Diagnostic
70 Diagnostic
102 Diagnostic Status
103 Energy Left Indicates the number of days of remaining battery life
104 Reset Energy Left Initialize the remaining battery life (Energy Left) and
Label Description
when the application software is downloaded.
UAP Used, for example, to check whether parameters have been change.
Indicates the vender ID, model ID, and revision of the
Number
Switch
Conguration
Detail[2]
device.
system (CTS).
(ITS).
the NAMUR NE107 Setting Enable diagnostic status conguration in UAP Option to Enable allows turning OFF and ON the display of the diagnostic results for each summary, and changing Categorize For Categorize at the time of shipment, refer to tables 7.3 and 9.2.
of UAP.
Software write protect
1: On, 0: Off
Enable hardware write protect
1: Enable, 0: Disable (default)
Enable diagnostic status conguration
1: Enable, 0: Disable (default) The following table shows the relationship between the hardware write protection and software write protection.
Enable
hardware
write
protect
Disable Off or On Off No
Disable Off or On On Yes
Enable Off Off or On No
Enable On Off or On Yes
Allows setting On/Off for each summary of Diagnostic Status when Enable diagnostic status conguration in UAP Option is set to Enable.
Allows Categorize for each summary of Diagnostic Status when Enable diagnostic status conguration in UAP Option is set to Enable.
Detailed information on Diagnostic Status. For Categorize at the time of shipment, refer to Table 9.2.
assuming ambient temperature condition as 23 degrees Celsius. The unit is day.
reset it as new batteries. Perform the battery replacement.
0 = Continue (Cancel) 1 = Reset (Initialization)
Hardware
protect
*1
model.
write
Software
write
protect
Write
protect
(Writable)
(Unwritable)
(Writable)
(Unwritable)
--- R
0 R
--- R
0 R
0 R
--- R
0 W
On W
Refer to Table
9.2.
Refer to Table
9.2.
--- R
0 (reading value is always 0)
Default
value
9-1
Handling
W
R
W
IM 01C27H01-01EN
<9. Parameter Summary>
9-2
Object
ID
1. UAPMO block (continued)
Attribute
ID
105 Power Supply
Label Description
Indicates the predicted battery level and the power
Status
supply method.
0 = external power supply 1 = battery level 75% or more 2 = battery level 25% ~ 75% 3 = battery level 25% or less
106 EHType
*2
107 Power Supply
*2
Voltage
110 Hardware Write
Protect
Available to write note into this parameter. --- W Indicates the measured power supply voltage (V). --- R
Allows recognizing the status of the hardware write protection switch. (Switch Off, Switch On)
111 Radio Silence Repeats a cycle of a 1-hour pause and 6-minute
search if the instrument cannot join the network after a time specied in Radio Silence has elapsed. When 0 is set, the Radio Silence is invalid.
112 Simulation Active
*2
Alert
The On/Off or priority for Simulation Active Alert can be set.
1. On/Off setting 0 = FALSE, 255 =TRUE
2. Alert report priority: 0 to 15
113 Soft Update
incomplete Alert
The On/Off or priority for Soft Update incomplete Alert
*2
can be set.
1. On/Off setting 0 = FALSE, 255 =TRUE
2. Alert report priority: 0 to 15
Not available for EJX.
114 Power low Alert
*2
The On/Off or priority for Power low Alert can be set.
1. On/Off setting 0 = FALSE, 255 =TRUE
2. Alert report priority: 0 to 15
115 Power Critical low
*2
Alert
The On/Off or priority for Power Critical low Alert can be set.
1. On/Off setting 0 = FALSE, 255 =TRUE
2. Alert report priority: 0 to 15
116 Fault prediction
*2
Alert
The On/Off or priority for Fault prediction Alert can be set.
1. On/Off setting 0 = FALSE, 255 =TRUE
2. Alert report priority: 0 to 15
Not available for EJX.
117 Environmental
conditions Alert
The On/Off or priority for Environmental conditions
*2
Alert can be set.
1. On/Off setting 0 = FALSE, 255 =TRUE
2. Alert report priority: 0 to 15
118 Outside sensor
limits Alert
*2
The On/Off or priority for Outside sensor limits Alert can be set.
1. On/Off setting 0 = FALSE, 255 =TRUE
2. Alert report priority: 0 to 15
119 Out of service
*2
Alert
The On/Off or priority for Out of service Alert can be set.
1. On/Off setting 0 = FALSE, 255 =TRUE
2. Alert report priority: 0 to 15
120 Callibration
problem Alert
The On/Off or priority for callibration problem Alert can
*2
be set.
1. On/Off setting 0 = FALSE, 255 =TRUE
2. Alert report priority: 0 to 15
Default
value
Handling
28800 W
1. TRUE
2. 15
1. TRUE
2. 15
1. TRUE
2. 15
1. TRUE
2. 15
1. TRUE
2. 15
1. TRUE
2. 15
1. TRUE
2. 15
1. TRUE
2. 15
1. TRUE
2. 15
R
R
W
W
W
W
W
W
W
W
W
IM 01C27H01-01EN
<9. Parameter Summary>
9-3
Object
ID
1. UAPMO block (continued)
2. UDO block
3. CO block
Attribute
ID
121 Faults Sensor or
122 Faults Electronics
123 Faults process
124 Faults non-
125 Other faults Alert
2 DESCRIPTION Indicates the version and model information of the
3 STATE Indicates the status of UAP block.
5 MAX_BLOCK_
14 LAST_BLOCK_
16 ERROR_CODE Indicates the error codes for DLError.
1 REVISION Indicates the revision number such as COMM_
2 COMM_
3 COMM_
Label Description
The On/Off or priority for Faults Sensor or actuator
*2
actuator Alert
*2
Alert
inuence Alert
compliance Alert
SIZE
DOWNLOADED
ENDPOINT
CONTRACT
Alert can be set.
1. On/Off setting 0 = FALSE, 255 =TRUE
2. Alert report priority: 0 to 15
The On/Off or priority for Faults Electronics Alert can be set.
1. On/Off setting 0 = FALSE, 255 =TRUE
2. Alert report priority: 0 to 1
The On/Off or priority for Faults process inuence Alert
*2
can be set.
1. On/Off setting 0 = FALSE, 255 =TRUE
2. Alert report priority: 0 to 15
Not available for EJX.
The On/Off or priority for Faults non-compliance Alert
*2
can be set.
1. On/Off setting
0 = FALSE, 255 =TRUE
2. Alert report priority: 0 to 15
Not available for EJX.
*2
The On/Off or priority for Other faults Alert can be set.
1. On/Off setting
0 = FALSE, 255 =TRUE
2. Alert report priority: 0 to 15
Not available for EJX.
downloaded data.
0 Idle 1 Downloading 3 Applying 4 DLComplete 6 DLError
Maximum block size. This value is smaller than the maximum data size of APDU.
Indicates the last downloaded block number. 0 means that no block has been downloaded.
0 = noError 1 = Timeout 2 = ClientAbort 64 = Apply failure
ENDPOINT, etc. Indicates the Endpoint information. The following
shows the components.
1. Network address of remote endpoint
2. Transport layer port at remote endpoint
3. Object ID at remote endpoint
4. Stale data limit
5. Data publication period
6. Ideal publication phase
7. PublishAutoRetransmit
8. Conguration status
Indicates the Contract information. The following shows the components.
1. ContractID
2. Contract_Status
3. Actual_Phase
Default
value
1. TRUE
2. 15
1. TRUE
2. 15
1. TRUE
2. 15
1. TRUE
2. 15
1. TRUE
2. 15
--- R
--- R
--- R
--- R
--- R
--- R
--- W
--- R
Handling
W
W
W
W
W
IM 01C27H01-01EN
<9. Parameter Summary>
9-4
Object
ID
3. CO block (continued)
4. TRANSDUCER block
Attribute
ID
4 PUB_ITEM_MAX Maximum PUB_ITEM value --- R 5 PUB_ITEM_NUM PUB_ITEM number --- R 6 PUB_ITEM Indicates the PUB_ITEM information. The following
1 Tag Description Memo eld available to write anything. Transducer W 2 Auto Recovery Allows specifying the action when the cause of a
3 Model Indicates the model name of the transmitter. --- R 4 Sensor Serial
5 Measurement
6 Measurement
7 Wireless Status Indicate the communication status.
8 Display Selection Select PV Value displaying on the LCD indicator.
9 LCD Mode Select the display mode on the LCD indicator.
10 Special Cmd Special function parameter.
Label Description
shows the components
1. ObjectID
2. AttributeID
3. AttributeIndex
4. Size
sensor failure is removed.
OFF (=0): AL continues to be indicated
even after the cause of the sensor error is removed, and the BURN OUT state is not released.
ON (=1): The AL indication for sensor
failure disappears and normal action is resumed when the cause of the sensor failure is removed.
Indicates the device number of the transmitter. --- R
Number
Indicates the measurement period of process values. --- R
Measurement mode selects continuous mode or intermittent mode. When the update time is set to 0.5 second intermittent mode, the mode is automatically switched to continuous mode. When the update time is set to 0.5 second*4, the computation process is in continuous mode, regardless of the measurement mode. When 0 is set, measurement period is set to 30 seconds regardless of measurement setting.
1. Indicates the initial idle status or join status.
(idle status, join status)
2. Indicates whether Contract(Pub) is established.
(not establishment, establishment)
3. Indicates whether Contract(R/W) is established.
(not establishment, establishment)
1. Indicates display status of PV Value of AI1
(displayed, not displayed)
2. Indicates display status of PV Value of AI2
(displayed, not displayed)
3. Indicates display status of PV Value of AI3
(displayed, not displayed)
1. Indicates the ON mode. (off, intermittent)
2. Indicates whether continuous or not.
(continuous off, continuous on)
3. Indicates the bar graph display.
(bar graph not displayed, bar graph displayed)
0 = initialize value at READ (None) 1 = Squawk status
2 = deep sleep status To start from deep sleep mode, either remove and insert the battery pack, or use the provisioning device tool or the device conguration tool via infrared communication.
Rate
Mode
*3
*4
in
*3
Default
value
--- W
ON W
intermittent mode
1. idle status
2. not estabilishment
3. not esabilishment
1. displayed
2. not displayed
3. not displayed
1. OFF
2. continuous
*3
OFF
3. bar graph not displayed
0 W
Handling
W
R
W
W
IM 01C27H01-01EN
<9. Parameter Summary>
9-5
Object
ID
4. TRANSDUCER block (continued)
5. AI1 block
Attribute
ID
11 Special Order ID Displays the special order number, if applicable. --- R 12 Unit Sel1 Selects whether to automatically apply the unit to the
13 Display Unit11 When Custom is selected in Unit Sel1, set the display
14 LCD Intermittetnt
15 XD Filter
16 Measurement
1 Process Value AL1 is a pressure output object.
2 Block Mode A universal parameter to indicate the block’s operation
3 Concentrator OID Indicates the Concentrator object value that
4 Scale Allows specifying the upper or lower limit for the PV
26 Tag Description A universal parameter to store the comment that
27 Process Value
28 Simulate Switch A simulation function switch for the AI object test
29 Transducer Value When Simulate Switch is set to Disable, this value
30 Simulate Value When Simulate Switch is set to Enable, this value is
51 Upper Limit Indicates the upper limit (URL) for the pressure. --- R
Label Description
word for the parameter for which the unit display is selected, or apply the characters that are written to Display Unit1. (Auto, Custom)
unit using 6 characters or less.
*2
Time
*2
Rate
Filter Time
*2
Set the time to turn off display on the LCD indicator. When 0 is set, it is diplayed in continuous mode.
Unit: second Set the damping time to Tranceducer value in the AI1
ans AI2 blocks.
Unit: second When Measurement mode is set to continuous mode, it is valid.
Indicates the cycle to publish the measurement value and status
Indicates the primary analog value (or corresponding process value) and status used to execute this function. Allows updating data by specifying this for the Concentrator object.
1. Value: output value of Al object
2. Status: Specify output status of Al object.
status. Each O/S, Auto, and Man can select from.
1. Target : Specify Al object mode.
2. Actual : Indicates current mode of Al object.
3. Permitted : Indicates the mode selected by Target of Al object.
4. Normal : Indicate normal status mode of Al object.
corresponds to the data update of the PV value.
scaling, unit code, etc.
1. EU at 100% : Indicate the upper limit of the PV value.
2. EU at 0% : Indicate the lower limit of the PV value.
3. Units Index : Indicate the setting unit used for the PV value.
4. Decimal : Indicate the digit number below the decimal point displayed in the LCD indicator.
describes the tag
Allows adjusting the time constant for ltering the PV value. Setting unit: Second. This is enabled for the Continuous mode.
(Disable, Enable)
is used as the input value for the AI object. Refer to Figure 10.1.
used as the input value for the AI object. The input value can be changed.
*5
Default
value
Auto W
NULL W
60 seconds W
2 seconds W
0 R
1. Value = ---
2. Status = ---
1. Target=Auto
2. Actual=Auto
3. Permitted= Auto
4. Normal=Auto
3 R
1. EU at 100% = 100
2. EU at 0% = 0
3. Units Index = %
4. Decimal = 2
Al1: Differential Pressure
0 second W
1 (Disable) W
Disable R
--- W
Handling
W
W
W
W
IM 01C27H01-01EN
<9. Parameter Summary>
9-6
Object
ID
5. AI1 block (continued)
Attribute
ID
52 Lower Limit Indicates the lower limit (LRL) for the pressure. --- R 53 PV Range Sets the measurement range.
54 Linearization Type Select either No Linearization or Square root as a
55 Flow Constant Indicates the ow coefcient, which shows the
56 Lower Cutoff Species the low cut value. The unit is subject to
57 Cal Cmd Species the calibration method.
58 Cal Status Indicates the calibration status.
59 Calibration Highest
60 Calibration Lowest
61 Calibration
104 External Zero Trim Allows performing external zero adjustment.
105 Low Cut Mode Species the low cut mode.
106 H/L Swap Allows performing reverse connection of the impulse
Label Description
1. EU at 100% : Indicates input value of the upper limit.
2. EU at 0% : Indicates input value of the lower limit.
3. Units Index : Indicates the units of the measurement range.
4. Decimal : Indicates the digit number below the decimal point.
setting of the output range.
0 = No Linearization : Provides an output value scaled according to the
PV Range and Scale range settings.
(To use Direct with FF, set the same value for PV
Range and Scale.)
10 = Square root : Provides a square root output computed for the
value scaled according to the PV Range and Scale range settings.
correlation between the ow rate value and square root value of the differential pressure.
Scale.Units Index.
0 = CAL_NONE : Initial state in which calibration is
not performed
1 = CAL_LOW : Applies an actual input and adjusts
the lower limit using the value specied in Calibration Lowest Point.
2 = CAL_HIGH : Applies an actual input and adjusts
the higher limit using the value specied in Calibration Highest Point.
5 = CAL_CLEAR : Clears the adjustment variable.
0 = CAL_NONE : Start-up and default value 1 = CAL_SUCCESS : Indicates that calibration was
successful.
7 = CAL_BAD_TRIM_POINT : Indicates this status
when the adjustment variable is outside of range.
Species the higher limit adjustment variable for
Point
Point
Minimum Span
adjustment between two points. Species the lower limit adjustment variable for the
adjustment between two points. Indicates the minimum span of the adjustment
variable.
(Trim on, Trim off)
(Linear, Zero)
line. (NORMAL, REVERSE : reverse connection) Used when the lower pressure side and higher pressure side of the impulse line were connected wrongly when installing the pressure transmitter.
Default
value
EU at 100% = 100 EU at 0% = 0 Units Index = kPa (1133) Decimal = 2
0 W
1.0 W
10 W
0 (reading value is always 0)
--- R
--- W
--- W
--- R
Trim on W
Linear W
Normal W
Handling
W
W
IM 01C27H01-01EN
<9. Parameter Summary>
9-7
Object
ID
5. AI1 block (continued)
6. AI2 block
Attribute
ID
107 T Zero Cmp Parameter to select the temperature zero shift
108 Temp Zero Parameter to set the temperature gradient value for the
109 Temp Select Parameter to select the temperature (amplier-side
1 Process Value AI2 is a static pressure output object.
2 Block Mode A universal parameter to indicate the block’s operation
3 Concentrator OID Indicates the Concentrator object value that
4 Scale Allows specifying the upper or lower limit for the PV
26 Tag Description A universal parameter to store the comment that
27 Process Value
28 Simulate Switch A simulation function switch for the AI object test
29 Transducer Value When Simulate Switch is set to Disable, this value is
30 Simulate Value When Simulate Switch is set to Enable, this value is
51 Upper Limit Indicates the upper limit (URL) for the pressure. --- R 52 Lower Limit Indicates the lower limit (LRL) for the pressure. --- R
Label Description
compensation mode
0 = OFF : Does not perform temperature zero shift
compensation.
1 = ON : Performs temperature zero shift
compensation.
temperature zero shift compensation
/ capsule-side) used for the temperature zero shift compensation.
0 = AMP TEMP : the value of the amplier-side
temperature sensor is used.
1 = CAP TEMP : the value of the capsule-side
temperature sensor is used.
Indicates the primary analog value (or corresponding process value) and status used to execute this function. Allows updating data by specifying this for the Concentrator object.
1. Value: output value of Al object
2. Status: Specify output status of Al object.
status. O/S, Auto, and Man can be selected.
1. Target : Specify Al object mode.
2. Actual : Indicates current mode of Al object.
3. Permitted : Indicates the mode selected by Target of Al object.
4. Normal : Indicate normal status mode of Al object.
corresponds to the data update of the PV value.
scaling, unit code, etc.
1. EU at 100% : Indicate the upper limit of the PV value.
2. EU at 0% : Indicate the lower limit of the PV value.
3. Units Index : Indicate the setting unit used for the PV value.
4. Decimal : Indicate the digit number below the decimal point displayed in the LCD indicator.
describes the tag. Allows adjusting the time constant for ltering the PV
Filter Time
value. Setting unit: Second. This is enabled for the Continuous mode.
(Disable, Enable)
used as the input value for the AI object.
used as the input value for the AI object. The input value can be changed.
Default
value
Off w
0 w
1 w
--- W
1.Target = O/S
2.Actual = O/S
3.Permitted = O/S
4.Normal = O/S
3 R
1. EU at 100% = 100
2. EU at 0% = 0
3. Units Index = %
4. Decimal = 2
AI2: Static Pressure
0 second W
Disable W
--- R
--- W
Handling
W
W
W
IM 01C27H01-01EN
<9. Parameter Summary>
9-8
Object
ID
6. AI2 block (continued)
7. AI3 block
Attribute
ID
53 PV Range Sets the measurement range.
54 Linearization Type Select either No Linearization or Square root as a
55 Flow Constant Indicates the ow coefcient, which shows the
56 Lower Cutoff Species the low cut value. The unit is subject to
57 Cal Cmd Species the calibration method.
58 Cal Status Indicates the calibration status.
59 Calibration Highest
60 Calibration Lowest
61 Calibration
102 Static Process
103 SP Select Parameter to select the High-side pressure or the Low-
1 Process Value Al3 is a temperature pressure output object.
Label Description
1. EU at 100% : Indicates input value of the upper limit.
2. EU at 0% : Indicates input value of the lower limit.
3. Units Index : Indicates the units of the measurement range.
4. Decimal : Indicates the digit number below the decimal point.
setting of the output range.
0 = No Linearization : Provides an output value scaled according to the
PV Range and Scale range settings.
(To use Direct with FF, set the same value for PV
Range and Scale.)
correlation between the ow rate value and square root value of the pressure.
Scale.Units Index.
0 = CAL_NONE : Initial state in which calibration is
not performed
1 = CAL_LOW : Applies an actual input and adjusts
the lower limit using the value specied in Calibration Lowest Point.
2 = CAL_HIGH : Applies an actual input and adjusts
the higher limit using the value specied in Calibration Highest Point.
5 = CAL_CLEAR : Clears the adjustment variable.
0 = CAL_NONE : Start-up and default value 1 = CAL_SUCCESS : Indicates that calibration was
successful.
7 = CAL_BAD_TRIM_POINT : Indicates this status
when the adjustment variable is outside of range.
Species the higher limit adjustment variable for
Point
Point
Minimum Span
Type
adjustment between two points. Species the lower limit adjustment variable for the
adjustment between two points. Indicates the minimum span of the adjustment
variable.
108 = Gauge pressure 109 = Absolute pressure
Selects the gauge pressure or the absolute pressure. Abs W
side pressure as the static pressure output.
0 = High : Displays the H-side pressure as the static
pressure
1 = Low : Displays the L-side pressure as the static
pressure
Indicates the primary analog value (or corresponding process value) and status used to execute this function. Allows updating data by specifying this for the Concentrator object.
1. Value: output value of Al object
2. Status: Specify output status of Al object.
Default
value
1. EU at 100% =
25000.000000 EU at 0% = 0 Units Index = kPa Decimal = 2
0 W
1.0 W
10 W
0 (reading value is always 0)
--- W
--- W
--- R
High W
1. Value = ---
2. Status = ---
Handling
W
W
R
W
IM 01C27H01-01EN
<9. Parameter Summary>
9-9
Object
ID
7. AI3 block (continued)
(Note) Handling: R=Read only, W=Read & Write (Note) “Factory NAMUR category” refers to the four categories (C: Check function, M: Maintenance required, F: Failure, and O: Off
specication) according to NAMUR NE107*.
Attribute
ID
2 Block Mode A universal parameter to indicate the block’s operation
3 Concentrator OID Indicates the Concentrator object value that
4 Scale Allows specifying the upper or lower limit for the PV
26 Tag Description A universal parameter to store the comment that
27 Process Value
28 Simulate Switch A simulation function switch for the AI object test
29 Transducer Value When Simulate Switch is set to Disable, this value is
30 Simulate Value When Simulate Switch is set to Enable, this value is
53 Sensor Range Parameter to nondimensionalize the sensor output
102 Tertiary Value
Label Description
status. O/S, Auto, and Man can be selected.
1. Target : Specify Al object mode.
2. Actual : Indicates current mode of Al object.
3. Permitted : Indicates the mode selected by Target of Al object.
4. Normal : Indicate normal status mode of Al object.
corresponds to the data update of the PV value.
scaling, unit code, etc.
1. EU at 100% : Indicate the upper limit of the PV value.
2. EU at 0% : Indicate the lower limit of the PV value.
3. Units Index : Indicate the setting unit used for the PV value.
4. Decimal : Indicate the digit number below the decimal point displayed in the LCD indicator.
describes the tag Allows adjusting the time constant for ltering the PV
Filter Time
Select
value. Setting unit: Second. This is enabled for the Continuous mode.
(Disable, Enable)
used as the input value for the AI object.
used as the input value for the AI object. The input value can be changed.
value. K and deg C are selectable for the temperature unit.
1. EU at 100% : Indicates input value of the upper limit.
2. EU at 0% : Indicates input value of the lower limit.
3. Units Index : Indicates the units of the measurement range.
4. Decimal : Indicates the digit number below the decimal point.
Species either the capsule temperature or amplier temperature as the output value. (CAP, AMP)
Default
value
1. Target = Auto
2. Actual = Auto
3. Permitted = O/S+Auto +Man
4. Normal = Auto
3 R
1. EU at 100% = 100
2. EU at 0% = 0
3. Units Index = %
4. Decimal = 2
AI3: Capsule temperature
0 second W
Disable W
--- R
--- W
1. EU at 100% = 130
2. EU at 0% = -50
3. Units Index = deg C
4. Decimal = 0
CAP W
Handling
W
W
W
W
*1: NAMUR NE107 “Self-Monitoring and Diagnosis of Field Devices” *2: Applicable for Detachable antenna type (Amplier housing code: 8 or 9). *3: Applicable for amplier housing code 7. *4: Applicable for amplier housing code 8 or 9. *5: Minimum value is 1 second, when amplier housing code 7 is specied. *6: It is valid for not only continuous mode but also intermittent mode, when amplier housing code 8 or 9 is specied.
IM 01C27H01-01EN
<9. Parameter Summary>
Table 9.2 Diagnostic Status Detail[0]
Bit Diagnostic Status Detail Description
DiagnosticDetail_1 31 FC_SENSOR_FAIL C sensor frequency error Bit26 F 30 FR_SENSOR_FAIL R sensor frequency error Bit26 F 29 CAP_T_SENSOR_FAIL Capsule temperature sensor failure Bit26 F 28 CAP_EEPROM_FAIL Capsule EEPROM failure Bit26 F 27 CAP_EEP_IRREGULAR CAP EEPROM version not correct Bit26 F 26 AMP_T_SENSOR_FAIL Amplier temperature sensor failure Bit27 F 25 AMP_EEPROM_FAIL Amplier EEPROM failure Bit27 F 24 AMP_EEP_IRREGULAR AMP EEPROM version not correct Bit27 F 22 G_A_COMM_FAIL G/A failure Bit27 F 21 FC_UNOSC_FAIL C sensor oscillation stop failure Bit26 F 20 FC_DELTA_T_FAIL C-side deltaT circuit failure Bit27 F 19 FR_DELTA_T_FAIL R-side deltaT circuit failure Bit27 F 18 WL_AD_FAIL Battery voltage not detected (AMP failure) Bit27 F 17 FR_UNOSC_FAIL R sensor oscillation stop failure Bit26 F 15 DP_OUTSIDE_LIMIT Pressure outside of specied range Bit23 O 14 SP_OUTSIDE_LIMIT Static pressure outside of specied range Bit23 O 13 CAPT_OUTSIDE_LIMIT Capsule temperature outside of specied range Bit23 O 12 AMPT_OUTSIDE_LIMIT Amplier temperature outside of specied range Bit23 O 7 DP_OUTSIDE_RANGE Input pressure setting outside of range Bit22 O 6 SP_OUTSIDE_RANGE Static pressure setting outside of range Bit22 O DiagnosticDetail_2 31 AI1_OUT_OF_SERVICE AI1 O/S mode Bit24 C 30 AI2_OUT_OF_SERVICE AI2 O/S mode Bit24 C 29 AI3_OUT_OF_SERVICE AI3 O/S mode Bit24 C 28 AI1_SIMULATION_ACTIVE AI1 simulation mode Bit17 C 27 AI2_SIMULATION_ACTIVE AI2 simulation mode Bit17 C 26 AI3_SIMULATION_ACTIVE AI3 simulation mode Bit17 C 20 DP_TRIM_SPAN_OUTSIDE Pressure span adjustment variable outside of range Bit25 C 19 DP_TRIM_ZERO_OUTSIDE Pressure zero adjustment variable outside of range Bit25 C 15 SP_TRIM_SPAN_OUTSIDE Static pressure span adjustment variable outside of
range
14 SP_TRIM_ZERO_OUTSIDE Static pressure zero adjustment variable outside of
range 13 WL_LOWBAT_ALM Low battery Bit19 M 12 CRITICAL_LOWBAT
*1
Detect a decrease in the lowest drive voltage. Bit20 M 10 WL_DEEPSLP_ALM Deep sleep due to low battery Bit20 M 8 LCD_OUTSIDE_LIMIT LCD display outside of specied range Bit25 C
*1: Applicable for amplier housing code 8 or 9. *2: Applicable for amplier housing code 7.
Diagnostic Status
assignment bit
Bit25 C
Bit25 C
9-10
NAMUR
AI algoritm
from operator
from operator
Value
& Status
from transducer
Value
& Status
from operator
Value
& Status
MODE Target
SIMULATE
SWITCH
SIMULATE
_VALUE
On
Off
PV.Status handling
AI
algorithm
Linearization
scaling,
filter
Figure 9.1 Example schema of analog input object
Mode and
Alert
report
HiHi etc
PV
PV
Auto
O/S
Man
PV
Publish
Value
& Status
F0901.ai
IM 01C27H01-01EN
<10. General Specications>
2
10. General Specications
10.1 Standard Specications
Communication protocol
ISA100.11a protocol
Data rate
250 kbps
Frequency
2400 - 2483.5 MHz license free ISM band
Radio security
AES 128 bit codied
RF Transmitter power
Max. 11.6 dBm (xed)
Antenna
+2 dBi Omni directional monopole type
Span and range limits
EJX118B
Measurement Span/Range
Span
M
Range Span
H
Range
kPa
2 to 100
–100 to 100
10 to 500
–500 to 500
EJX438B
Measurement
Span and Range
*1
A
Range
Span
Flush
*1
type
B
*1: Measurement range is within the ange rating.
Range
Span
Extended
*1
type
Range –1 to 70
Performance specications
Refer to GS01C27H01-01EN
Update Time
Measurement
mode
Continuous 100 ms 100 ms
Intermittent
For amplier housing code 7: The transmitter shifts to the countinuous mode when the update time is set to 1 second.
inH2O(/D1)
8 to 400
–400 to 400
40 to 2000
–2000 to 2000
MPa
0.035 to 3.5 5 to 500Span
–0.1 to 3.5 –14.5 to 500
0.16 to 16
–0.1 to 16
–0.1 to 7
20 to 1000
–1000 to 1000
100 to 5000
–5000 to 5000
psi (/D1) bar (/D2)
23 to 2300
–14.5 to 2300
23 to 1000 1.6 to 700.16 to 7
–14.5 to 1000
Differential
pressure
0.5 to 3600 s selectable
mbar(/D3)
–1 to 35
1.6 to 160
–1 to 160
mmH2O(/D4)
200 to 10000
–10000 to 10000
0.1 to 5 kgf/cm –5 to 5 kgf/cm
Pressure
0.5 to 3600 s selectable
2
2
T01E.ai
kgf/cm2 (/D3)
0.35 to 350.35 to 35
–1 to 35
1.6 to 160
–1 to 160
1.6 to 70
–1 to 70
T02E.ai
Minimum update time is 1 second. For amplier housing code 8 and 9: The transmitter shifts to the countinuous mode when the update time is set to 0.5 second.
Power Supply Specications
Battery:
Use the dedicated battery pack. Rated voltage: 7.2 V Rated capacity: 19 Ah
Output
Wireless (ISA100.11a protocol) 2.4 GHz signal. Output mode for EJX118B, linear or square root, is selectable.
Zero Adjustment Limits
Zero can be fully elevated or suppressed, within the lower and upper range limits of the capsule.
External Zero Adjustment
External Zero is continuously adjustable with
0.01% incremental resolution of span. Re-range can be done locally using the digital indicator with range-setting switch.
Integral Indicator (LCD display)
5-digit numerical display, 6-digit unit display and bar graph. The indicator is congurable to display one or up to three of the following variables periodically.; Differential pressure, static pressure, temperature.
Self Diagnostics
Capsule failure, amplier failure, conguration error, battery alarm, wireless communication alarm and over-range error for process variables.
Capillary Fill Fluid Density Compensation
Compensation of the zero shift by the ambient temperature effect on the capillary tube.
Ambient Temperature Limits
-40 to 85°C (-40 to 185°F)
-30 to 80°C (-22 to 176°F) LCD visible range
Note: The ambient temperature limits must be within the ll uid
operating temperature range, see table 10.1.
Process Temperature Limits
See table 10.1.
10-1
IM 01C27H01-01E
<10. General Specications>
Process temperature
Process temperature
Atmospheric
Process temperature
Atmospheric
Ambient Humidity Limits
0 to 100% RH
Working Pressure Limits
See table 10.1. For atmospheric pressure or below, see gure
10.1 and 10.2.
Table 10.1 Process temperature, Ambient temperature, and Working pressure
*1
*4
–10 to 60°C
(14 to 140°F)
–15 to 60°C (5 to 140°F)
10 to 60°C
(50 to 140°F)
–10 to 60°C
(14 to 140°F)
–40 to 60°C
(–40 to 140°F)
Silicone oil (general use)
Silicone oil (general use)
Silicone oil (high temperature use)
Fluorinated oil (oil-prohibited use)
Ethylene glycol (low temperature use)
Code Ambient temperature
Process temperature
A
B
C
D
E
–10 to 250°C
(14 to 482°F)
–30 to 180°C
(–22 to 356°F)
10 to 310°C
(50 to 590°F)
–20 to 120°C (–4 to 248°F)
–50 to 100°C
(–58 to 212°F)
*1: See gure 10-1 and 10-2 ‘Working Pressure and Process Temperature. *2: This ambient temperature is the transmitter ambient temperature. *3: Approximate values at a temperature of 25°C (77°F) *4: In case of wetted parts material code TW (Tantalum), process temperature limit is up to 200°C (392°F).
*2
Working pressure
2.7 kPa abs
(0.38 psi abs) to
flange rating pressure
51 kPa abs
(7.4 psi abs) to
flange rating pressure
100 kPa abs
(atmospheric pressure)
to flange pressure rating
10-2
Specific gravity
1.07
0.94
1.09
1.90 to 1.92
1.90
*3
T06E.ai
Note: The differential pressure transmitter should be installed at least 600 mm below the high pressure (HP) process connection.
However, this value (600 mm) may be affected by ambient temperature, operating pressure, ll uid or material of the wetted diaphragm. Contact YOKOGAWA when the transmitter can not be installed at least 600 mm below the HP process connection..
Transmitter ambient temperature range (for fill fluid code A, B)
Working pressure kPa abs (psi abs)
for fill fluid code B
100 (14.5)
10 (1.4)
2.7 (0.38)
1(0.14)
0.1(0.014)
-50 0 50 100 150 200 250 300 350
Process temperature for fill fluid code A
Process Temperature (°C)
Figure 10.1 Working Pressure and Process
Temperature (Fill uid : silicone oil for general and high temperature use)
for fill fluid code C
Flange max. working pressure
pressure
F01E.ai
Transmitter ambient temperature range (for fill fluid code D)
100 (14.5)
51 (7.4) Working pressure
kPa abs
(psi abs)
10(1.4)
2.7 (0.38)
1 (0.14)
0.1(0.014)
Figure 10.2 Working Pressure and Process
for fill fluid code E
-50 0 50 100 150 200 250 300 350
Process Temperature (°C)
Process temperature for fill fluid code D
Temperature (Fill uid : uorinated oil for oil-prohibited use and ethylene glycol for low temperature use)
F02E.ai
Flange max. working pressure
pressure
IM 01C27H01-01E
<10. General Specications>
10-3
EMC Conformity Standards
EN61326-1 Class A, Table 2 (For use in industrial locations), EN61326-2-3
R&TTE Conformity Standards
ETSI EN 300 328, ETSI EN 301 489-1, ETSI EN 301 489-17, EN61010-1, EN61010-2-030, EN62311
• Indoor/Outdoor use
Regulation Conformity of the Wireless Module
• FCC Approval
• IC Approval
Safety Requirement Standards
EN61010-1, EN61010-2-030
• Altitude of installation site: Max. 2,000 m above sea level
• Installation category: I (Anticipated transient overvoltage 330 V)
• Pollution degree: 2
• Indoor/Outdoor use
Process connections
See the following table.
Table 10.2 Flange size and rating
Process
connection style
Flush type
Extended type
Combination type
(Extended and
*1: Flushing connection rings are always attached. *2: Applicable for EJX438B only. *3: Applicable for EJX118B only.
Flush)*
3
Size
3-inch 2-inch
1/2
1
-inch*
1
4-inch 3-inch
High pressure side: 4-inch Low pressure side: 3-inch
Flange
JIS 10K, 20K, 40K, 63K* ANSI Class 150, 300, 600 JPI Class 150, 300, 600 DIN PN10/16, 25/40, 64
JIS 10K, 20K, 40K* ANSI Class 150, 300 JPI Class 150, 300 DIN PN10/16, 25/40
JIS 10K, 20K ANSI Class 150, 300 JPI Class 150, 300 DIN PN10/16, 25/40
2
2
T07E.ai
Gasket Contact Surface
See the following table.
Table 10.3 Gasket contact surface
SW, SE,
SY
ANSI
HW, TW,
UW
T08E.ai
Flange
Wetted parts material code
*1
Gasket contact Surface
: Applicable, —: Not applicable *1: ANSI B16.5
Serration
Flat (No serration)
JIS/JPI/DIN
SW,
HW,
SE,
TW,
SY
UW
Electrical Connections
See “MODEL AND SPECIFICATIONS.”
Transmitter Mounting
2-inch pipe mounting
Wetted Parts Material
Diaphragm seal Diaphragm and other wetted parts;
Refer to “Model And Sufx Codes.”
Flushing connection ring (optional) Ring and Vent / Drain plugs
Refer to “Model And Sufx Codes.” (Spiral) gasket for transmitter side 316 SST (Hoop), PTFE Teon (Filler)
Non-wetted Parts Material
Transmitter body section: Cover ange
ASTM CF-8M
Cover ange bolting
ASTM-B7 carbon steel, 316L SST stainless steel, or ASTM grade 660 stainless steel
Housing
Low copper cast aluminum alloy with polyurethane, mint-green paint (Munsell
5.6BG 3.3/2.9 or its equivalent)
Degrees of Protection
IP66/IP67, NEMA4X
Name plate and tag
316 SST tag plate wired onto transmitter
Diaphragm seal section: Process Flange
JIS S25C, JIS SUS304, or JIS SUS316
Capillary tube
316 SST
Protection tube
304 SST PVC-sheathed (Max. operating temperature of PVC,100°C (212°F))
Fill uid
See table 10.1.
IM 01C27H01-01E
<10. General Specications>
Weight
EJX118B
Flush type: 18.2 kg (40.1 lbs) (3-inch ANSI Class150 ange, capillary length 5 m; without integral indicator and mounting bracket.) Extended type: 23.8 kg (52.5 lbs) (4-inch ANSI Class150 ange, extension length
)=100 mm, capillary length 5 m; without
(X
2
integral indicator and mounting bracket.) Combination type: 21.0 kg (46.3 lbs) (4-inch and 3-inch ANSI Class150 ange, extension length (X2) =100 mm, capillary length 5 m; without integral indicator and mounting bracket.)
EJX438B
Flush type: 9.2 kg (20.3 lbs) (3-inch ANSI Class 150 ange, capillary length 5 m; without integral indicator and mounting bracket.) Extended type: 14.3 kg (31.5 lbs) (4-inch ANSI Class 150 ange, extension length
)=100 mm, capillary length 5 m; without
(X
2
integral indicator and mounting bracket.)
10-4
IM 01C27H01-01E
<10. General Specications>
EJX118B
EJX118B
10-5
10.2 Model and Sufx Codes
Instruction
The model and sufx codes for EJX118B and EJX438B consist of two parts; a transmitter body section (I) and a diaphragm seal section (II). This specication sheet introduces these two parts separately. The transmitter body section is shown in one table, and the diaphragm seal section specications are listed according to the process connection style. First select the model and sufx codes of transmitter body section and then continue on one of the diaphragm seal section.
EJX438B
I Transmitter body section II Diaphragm seal section
F03E.ai
I. Transmitter body section
EJX438B
Model
EJX118B EJX438B
Output signal
Measurement span (capsule)
Coverflange bolts and nuts material
Installation
Amplifier housing
Electrical connection
Integral Indicator
Mounting braket
Diaphragm seal section
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
- L. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
*2
M
*2
H
*3
A
*3
B
Suffix codes
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
S . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C . . . . . . . . . . . . . . . . . . . . . . . . .
J . . . . . . . . . . . . . . . . . . . . . .
G . . . . . . . . . . . . . . . . . . . . . .
C . . . . . . . . . . . . . . . . . . . . . .
-9 . . . . . . . . . . . . . . . . . . .
7 . . . . . . . . . . . . . . . . .
8 . . . . . . . . . . . . . . . . .
9 . . . . . . . . . . . . . . . . .
J . . . . . . . . . . . . . .
D . . . . . . . . . . .
B . . . . . . . .
N . . . . . . . .
Diaphragm sealed differential pressure transmitter Diaphragm sealed Gauge Pressure transmitter
Wireless communication (ISA100.11a protocol)
2 to 100 kPa (8 to 400 inH 10 to 500 kPa (40 to 200 inH
0.035 to 3.5 MPa (5 to 500 psi)
0. 16 to 16 MPa (23 to 2300 psi)
Always S
Always C
ASTM-B7 carbon steel 316L SST stainless steel ASTM grade660 stainless steel
Horizontal piping type and left side high pressure
Cast aluminum alloy with integral antenna Cast aluminum alloy with detachable antenna (2 dBi)* Cast aluminum alloy without antenna (N connector)*4*
No electrical connection, battery-powered type (battery case only; battery cells not included)
Digital indicator
304 SST 2-inch pipe mounting, flat type (for horizontal piping) None
Description
O)
2
O)
2
*1
Continued on diaphragm seal section (II)
The “►” marks indicate the most typical selection for each specication. *1: When specied process connection style code E, maximum range and span are 7 MPa (1000 psi.) *2: Applicable for EJX118B *3: Applicable for EJX438B *4: Order the antenna separately from accessary option. *5: Remote antenna cables can be attached. Order separately from accessary option.
5
5
T09E.ai
IM 01C27H01-01E
<10. General Specications>
II. Diaphragm seal section (Flush type)
Process connection size: 3-inch (80 mm) / 2-inch (50 mm)
10-6
EJX118B EJX438B
Model
Suffix codes
EJX118B EJX438B
Flange rating
Process connection size (Process flange size)
Flange material
Gasket contact surface
Wetted parts material
*1
*10
Flushing connection ring*2
Extension
Fill fluid
Capillary connection
Capillary length
*6
Option codes
. . . . . . . . . . . . . . . . . . . .
-W . . . . . . . . . . . . . . . . . . . . .
J1 . . . . . . . . . . . . . . . . . . . .
J2 . . . . . . . . . . . . . . . . . . . .
J4 . . . . . . . . . . . . . . . . . . . .
J6 . . . . . . . . . . . . . . . . . . . .
A1 . . . . . . . . . . . . . . . . . . . .
A2 . . . . . . . . . . . . . . . . . . . .
A4 . . . . . . . . . . . . . . . . . . . .
D2 . . . . . . . . . . . . . . . . . . . .
D4 . . . . . . . . . . . . . . . . . . . .
D5 . . . . . . . . . . . . . . . . . . . .
3 . . . . . . . . . . . . . . . . . . . .
2 . . . . . . . . . . . . . . . . . . . .
A . . . . . . . . . . . . . . . . . .
B . . . . . . . . . . . . . . . . . .
C . . . . . . . . . . . . . . . . . .
1 . . . . . . . . . . . . . . . . .
2 . . . . . . . . . . . . . . . . .
SW . . . . . . . . . . . . . .
HW . . . . . . . . . . . . .
TW . . . . . . . . . . . . . .
UW . . . . . . . . . . . . .
0 . . . . . . . . . . . . . .
1 . . . . . . . . . . . . . .
2 . . . . . . . . . . . . . .
A . . . . . . . . . . . . . .
B . . . . . . . . . . . . . .
0 . . . . . . . . . . . .
-A . . . . . . . . . .
-B . . . . . . . . . .
-C . . . . . . . . . .
-D . . . . . . . . . .
-E . . . . . . . . . .
A . . . . . . . . .
2 . . . . . . . .
1 . . . . . . .
2 . . . . . . .
3 . . . . . . .
4 . . . . . . .
5 . . . . . . .
6 . . . . . . .
7 . . . . . . .
8 . . . . . . .
9 . . . . . . .
A . . . . . . .
3
W
2
Description
Transmitter body section (I)
Flush typeProcess connection style
JIS 10K JIS 20K JIS 40K JIS 63K
ANSI class 150 P1 . . . . . . . . . JPI class 150
ANSI class 300 P2 . . . . . . . . . JPI class 300
ANSI class 600 P4 . . . . . . . . . JPI class 600
DIN PN10/16 DIN PN25/40 DIN PN64
3-inch (80 mm) 2-inch (50 mm)
JIS S25C JIS SUS304 JIS SUS316
Serration (for ANSI flange with wetted parts material SW only) Flat (no serration)
[Diaphragm] [Others] JIS SUS316L JIS SUS316L Hastelloy C-276 Tantalum
*9#
*7
Hastelloy C-276
Tantalum*7
*9#
Titanium Titanium
[Ring] [Drain/Vent plugs] [Material] None — Straight type R 1/4 connections Straight type 1/4 NPT connections JIS SUS316 Straight type R 1/4 connections
*8
JIS SUS316
*8
JIS SUS316
Straight type 1/4 NPT connections JIS SUS316
# # #
#
None
[Process temp.] [Ambient temp.] For general use (silicone oil) For general use (silicone oil) –30 to 180°C –15 to 60°C For high temperature use (silicone oil) For oil-prohibited use (fluorinated oil)
*3
–10 to 250°C –10 to 60°C
*4 *7
10 to 310°C 10 to 60°C
*5
–20 to 120°C –10 to 60°C
For low temperature use (ethylene glycol) –50 to 100°C –40 to 60°C
Side of diaphragm seal unit
Always 2 1 m
2 m 3 m 4 m 5 m 6 m 7 m 8 m 9 m 10 m
Optional specification
/
F07E.ai
EJX118B
  
     
 
  
 
   
  
– –
    
         
T10E.ai
EJX438B
         
 
  
 
   
– –
 
    
         
The “►” marks indicate the most typical selection for each specication. Example: EJX118B-LMSCG-97JDN-WA13B1SW00-BA25/□ EJX438B-LASCG-97JDN-WA13B1SW00-BA25/□ *1: See table 10-3 ‘Gasket contact surface.’ *2: When specied ushing connection ring code 1, 2, A, or B, exclusive gasket is provided for transmitter side. *3: In case of wetted parts material code TW (Tantalum), the process temperature limit is –10 to 200˚C. *4: Wetted parts material code TW (Tantalum) cannot be applied. *5: Even in case where ll uid code D (uorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing and
dehydrating treatment for the wetted parts is required, specify option code K1 or K5.
IM 01C27H01-01E
<10. General Specications>
*6: In case of wetted parts material code HW (Hastelloy C), TW (Tantalum), and UW (Titanium) for 2-inch pressure ange, specify
capillary length from 1 to 5 m. *7: Not applicable for ashing connection ring code 1 and 2. *8: Not applicable for gasket contact surface code 1. *9: Hastelloy C-276 or N10276. *10: Users must consider the characteristics of selected wetted parts material and the inuence of process uids. The use of
inappropriate materials can result in the leakage of corrosive process uids and cause injury to personnel and/or damage to plant
facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the ll uid
can contaminate the user’s process uids. Be very careful with highly corrosive process uids such as hydrochloric acid, sulfuric acid, hydrogen sulde, sodium hypochlorite,
and high-temperature steam (150˚C [302˚F] or above). Contact Yokogawa for detailed information of the wetted parts material. The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR01-75. For the use of 316
SST material, there may be certain limitations for pressure and temperature. Please refer to NACE standards for details
10-7
IM 01C27H01-01E
<10. General Specications>
II. Diaphragm seal section (Flush type)
Process connection size: 1 1/2-inch (40 mm)
10-8
Model
EJX118B EJX438B
Flange rating
Process connection size (Process flange size)
Flange material
Gasket contact surface
Wetted parts material
Flushing connection ring*2
Extension Fill fluid
Capillary connection
Capillary length
Option codes
*1
*5
EJX118B EJX438B
Suffix codes
. . . . . . . . . . . . . . . . . . . .
-W . . . . . . . . . . . . . . . . . .
J1 . . . . . . . . . . . . . . . . .
J2 . . . . . . . . . . . . . . . . .
J4 . . . . . . . . . . . . . . . . .
A1 . . . . . . . . . . . . . . . . .
A2 . . . . . . . . . . . . . . . . .
A4 . . . . . . . . . . . . . . . . .
P1 . . . . . . . . . . . . . . . . .
P2 . . . . . . . . . . . . . . . . .
P4 . . . . . . . . . . . . . . . . .
8 . . . . . . . . . . . . . . . . .
A . . . . . . . . . . . . . . .
B . . . . . . . . . . . . . . .
C . . . . . . . . . . . . . . .
1 . . . . . . . . . . . . . .
2 . . . . . . . . . . . . . .
SW . . . . . . . . . . .
3 . . . . . . . . . . . .
4 . . . . . . . . . . . .
C . . . . . . . . . . . .
D . . . . . . . . . . . .
0 . . . . . . . . . . .
-A . . . . . . . . .
-B . . . . . . . . .
-D . . . . . . . . .
-E . . . . . . . . .
A . . . . . . . .
2 . . . . . . .
1 . . . . .
2 . . . . .
3 . . . . .
4 . . . . .
5 . . . . .
6 . . . . .
7 . . . . .
8 . . . . .
9 . . . . .
A . . . . .
Transmitter body section (I)
Flush typeProcess connection style
JIS 10K JIS 20K JIS 40K ANSI class 150 ANSI class 300 ANSI class 600 JPI class 150 JPI class 300 JPI class 600
1 1/2-inch (40 mm)
JIS S25C JIS SUS304 JIS SUS316
Serration (for ANSI flange only) Flat (no serration)
[Diaphragm] [Others] JIS SUS316L JIS SUS316L
[Ring] [Drain/Vent plugs] [Material] Reducer type R 1/4 connections Reducer type 1/4 NPT connections JIS SUS316 Reducer type R 1/4 connections Reducer type 1/4 NPT connections JIS SUS316
None
For general use (silicone oil) –10 to 250°C –10 to 60°C For general use (silicone oil) –30 to 180°C –15 to 60°C For oil-prohibited use (fluorinated oil) For low temperature use (ethylene glycol) –50 to 100°C –40 to 60°C
Side of diaphragm seal unit
Always 2 1 m
2 m 3 m 4 m 5 m 6 m 7 m 8 m 9 m 10 m
/ Optional specification
8
W
F08E.EPS
Description
EJX118B
        
  
 
 
*4
JIS SUS316
*4
JIS SUS316
[Process temp.] [Ambient tempe.]
*3
–20 to 120°C –10 to 60°C
#
#
#
#
   
         
T11E.ai
The “►” marks indicate the most typical selection for each specication. Example: EJX118B-LMSCG-97JDN-WA18B1SW40-BA25/□ EJX438B-LASCG-97JDN-WA18B1SWD0-BA25/□ *1: See table 10-3 ‘Gasket contact surface.’ *2: When specied ushing connection ring code 3, 4, C, or D, exclusive gasket is provided for transmitter side. *3: Even in case where ll uid code D (uorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing and
dehydrating treatment for the wetted parts is required, specify option code K1 or K5. *4: Not applicable for gasket contact surface code 1. *5: Users must consider the characteristics of selected wetted parts material and the inuence of process uids. The use of
inappropriate materials can result in the leakage of corrosive process uids and cause injury to personnel and/or damage to plant
facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the ll uid
can contaminate the user’s process uids. Be very careful with highly corrosive process uids such as hydrochloric acid, sulfuric acid, hydrogen sulde, sodium hypochlorite,
and high-temperature steam (150˚C [302˚F] or above). Contact Yokogawa for detailed information of the wetted parts material.
EJX438B
        
  
 
– –
 
   
         
IM 01C27H01-01E
<10. General Specications>
II. Diaphragm seal section (Extended type)
Process connection size: 4-inch (100 mm) / 3-inch (80 mm)
10-9
Model
EJX118B EJX438B
Flange rating
Process connection size (Process flange size)
Flange material
Gasket contact surface
Wetted parts material
Flushing connection ring Extension
Fill fluid
Capillary connection
Capillary length
Option codes
*4
*3
*1
EJX118B EJX438B
Suffix codes
. . . . . . . . . . . . . . . . . . . .
-E . . . . . . . . . . . . . . . . . .
J1 . . . . . . . . . . . . . . . . .
J2 . . . . . . . . . . . . . . . . .
J4 . . . . . . . . . . . . . . . . .
A1 . . . . . . . . . . . . . . . . .
A2 . . . . . . . . . . . . . . . . .
P1 . . . . . . . . . . . . . . . . .
P2 . . . . . . . . . . . . . . . . .
D2 . . . . . . . . . . . . . . . . .
D4 . . . . . . . . . . . . . . . . .
4 . . . . . . . . . . . . . . . . .
3 . . . . . . . . . . . . . . . . .
A . . . . . . . . . . . . . . .
B . . . . . . . . . . . . . . .
C . . . . . . . . . . . . . . .
1 . . . . . . . . . . . . . .
2 . . . . . . . . . . . . . .
SE . . . . . . . . . . . .
0 . . . . . . . . . . . .
1 . . . . . . . . . . .
2 . . . . . . . . . . .
3 . . . . . . . . . . .
4 . . . . . . . . . . .
5 . . . . . . . . . . .
6 . . . . . . . . . . .
-A . . . . . . . . .
-B . . . . . . . . .
-C . . . . . . . . .
-D . . . . . . . . .
-E . . . . . . . . .
B . . . . . . . .
2 . . . . . . .
1 . . . . .
2 . . . . .
3 . . . . .
4 . . . . .
5 . . . . .
6 . . . . .
7 . . . . .
8 . . . . .
9 . . . . .
A . . . . .
Transmitter body section (I)
Extended typeProcess connection style
JIS 10K JIS 20K JIS 40K ANSI class 150 ANSI class 300 JPI class 150 JPI class 300 DIN PN10/16 DIN PN25/40
4-inch (100 mm) 3-inch (80 mm)
JIS S25C JIS SUS304 JIS SUS316
Serration (for ANSI flange only) Flat (no serration)
[Diaphragm] [Pipe] [Others] JIS SUS316L JIS SUS316 JIS SUS316
None Length (X2) = 50 mm
Length (X2) = 50 mm Length (X2) = 100 mm Length (X2) = 100 mm Length (X2) = 150 mm Length (X2) = 150 mm [Process temp.] [Ambient temp.] For general use (silicone oil) –10 to 250°C –10 to 60°C For general use (silicone oil) –30 to 180°C –15 to 60°C For high temperature use (silicone oil) 10 to 310°C 10 to 60°C For oil-prohibited use (fluorinated oil) For low temperature use (ethylene glycol) –50 to 100°C –40 to 60°C Back of diaphragm seal unit
Always 2
1 m 2 m 3 m 4 m 5 m 6 m 7 m 8 m 9 m 10 m / Optional specification
4
E
3
F09E.EPS
Description
EJX118B
 
     
 
  

 
 
 
*2
–20 to 120°C –10 to 60°C
   
         
T12E.ai
The “►” marks indicate the most typical selection for each specication. Example: EJX118B-LMSCG-97JDN-EA14B1SE02-BB25/□ EJX438B-LASCG-97JDN-EA14B1SE01-BB25/□ *1: See table 10-3 ‘Gasket contact surface.’ *2: Even in case where ll uid code D (uorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing and
dehydrating treatment for the wetted parts is required, specify option code K1 or K5. *3: The specied capillary length includes the extension length (X2) and the ange thickness (t). *4: Users must consider the characteristics of selected wetted parts material and the inuence of process uids. The use of
inappropriate materials can result in the leakage of corrosive process uids and cause injury to personnel and/or damage to plant
facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the ll uid
can contaminate the user’s process uids. Be very careful with highly corrosive process uids such as hydrochloric acid, sulfuric acid, hydrogen sulde, sodium hypochlorite,
and high-temperature steam (150˚C [302˚F] or above). Contact Yokogawa for detailed information of the wetted parts material.
EJX438B
        
 
  
     
         
IM 01C27H01-01E
<10. General Specications>
10-10
II. Diaphragm seal section (Combination type)
Process connection size: High pressure side; 4-inch (100 mm) • • • Extended type
Low pressure side; 3-inch (80 mm) • • • Flush type
W
F10E.EPS
Description
temperature] temperature]
*2
–20 to 120°C –10 to 60°C
T13E.ai
Model
EJX118B
Flange rating
Process connection size (Process flange size)
Flange material
Gasket contact surface
Wetted parts material
Flushing connection ring
Extension
Fill fluid
Capillary connection
Capillary length
Option codes
*4
*3
EJX118B Y
Suffix codes
. . . . . . . . . . . . . . . . . . . . . . .
-Y . . . . . . . . . . . . . . . . . . . . .
J1 . . . . . . . . . . . . . . . . . . .
J2 . . . . . . . . . . . . . . . . . . .
A1 . . . . . . . . . . . . . . . . . . .
A2 . . . . . . . . . . . . . . . . . . .
P1 . . . . . . . . . . . . . . . . . . .
P2 . . . . . . . . . . . . . . . . . . .
D2 . . . . . . . . . . . . . . . . . . .
D4 . . . . . . . . . . . . . . . . . . .
W . . . . . . . . . . . . . . . . . .
A . . . . . . . . . . . . . . . . .
B . . . . . . . . . . . . . . . . .
C . . . . . . . . . . . . . . . . .
*1
1 . . . . . . . . . . . . . . . .
2 . . . . . . . . . . . . . . . .
SY . . . . . . . . . . . . .
0 . . . . . . . . . . . . .
1 . . . . . . . . . . . .
3 . . . . . . . . . . . .
5 . . . . . . . . . . . .
-A . . . . . . . . . .
-B . . . . . . . . . .
-C . . . . . . . . . .
-D . . . . . . . . . .
-E . . . . . . . . . .
C . . . . . . . . .
2 . . . . . . . .
1 . . . . . .
2 . . . . . .
3 . . . . . .
4 . . . . . .
5 . . . . . .
6 . . . . . .
7 . . . . . .
8 . . . . . .
9 . . . . . .
A . . . . . .
Transmitter body section (I)
Combination type (Extended and Flush)Process connection style
JIS 10K JIS 20K ANSI class 150 ANSI class 300 JPI class 150 JPI class 300 DIN PN10/16 DIN PN25/40
High pressure side 4-inch (100 mm) Low pressure side 3-inch (80 mm)
JIS S25C JIS SUS304 JIS SUS316
Serration (for ANSI flange only) Flat (no serration)
[Diaphragm] [Pipe] [Others] High pressure side: JIS SUS316L JIS SUS316 JIS SUS316 Low pressure side: JIS SUS316L JIS SUS316L
None
Length (X2) = 50 mm Length (X2) = 100 mm Length (X2) = 150 mm
[Process [Ambient
For general use (silicone oil) –10 to 250°C –10 to 60°C For general use (silicone oil) –30 to 180°C –15 to 60°C For high temperature use (silicone oil) 10 to 310°C 10 to 60°C For oil-prohibited use (fluorinated oil) For low temperature use (ethylene glycol) –50 to 100°C –40 to 60°C
High pressure side: Back of diaphragm seal unit Low pressure side: Side of diaphragm seal unit
Always 2
1 m 2 m 3 m 4 m 5 m 6 m 7 m 8 m 9 m 10 m
/ Optional specification
The “►” marks indicate the most typical selection for each specication. Example: EJX118B-LMSCG-97JDN-YA1WB1SY01-BC25/□ *1: See table 10-3 ‘Gasket contact surface.’ *2: Even in case where ll uid code D (uorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing and
dehydrating treatment for the wetted parts is required, specify option code K1 or K5. *3: The specied capillary length of high pressure side (extended side) includes the extension length (X2) and the ange thickness (t). *4: Users must consider the characteristics of selected wetted parts material and the inuence of process uids. The use of
inappropriate materials can result in the leakage of corrosive process uids and cause injury to personnel and/or damage to plant
facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the ll uid
can contaminate the user’s process uids. Be very careful with highly corrosive process uids such as hydrochloric acid, sulfuric acid, hydrogen sulde, sodium hypochlorite,
and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.
IM 01C27H01-01E
<10. General Specications>
10-11
10.3 Optional Specications
OPTIONAL SPECIFICATIONS (For Explosion Protected type)
Item Description Code
Factory Mutual (FM) FM Intrinsically safe Approval FS17 ATEX ATEX Intrinsically safe Approval KS27 Canadian Standards Association (CSA) CSA Intrinsically safe Approval CS17 IECEx IECEx Intrinsically safe Approval SS27
IM 01C27H01-01E
<10. General Specications>
10-12
OPTIONAL SPECIFICATIONS (Others)
DescriptionItem
Painting
Color change Coating change
Amplifier cover only Anti-corrosion coating *
1
Degrease cleansing treatmentOil-prohibited use
Oil-prohibited use with dehydrating treatment
Calibration units
Teflon film
*3
*2 *7
Degrease cleansing treatment and dehydrating treatment
P calibration (psi unit) bar calibration (bar unit) M calibration (kgf/cm
2
unit)
(See table for Span and
Range Limits.)
Diaphragm protection from sticky process fluid by FEP Teflon film attached with fluorinated oil. Operation range: 20 to 150°C, 0 to 2 MPa (Not applicable for vacuum service).
Operating temperature correction
*4
Adjusting range : 80°C to Maximum temperature of specified fill fluid When ambient temperature exceeds 100°C, or use of PVC is prohibitedCapillary without PVC sheaths
Gold-plated diaphragm
Material certificate
*5
Inside of isolating diaphragms (fill fluid side) are gold plated, effective for hydrogen permeation.
Process flange, Block Process flange, Block, Ring
*6
Process flange, Block, Pipe, Base High Pressure side: Process flange, Block, Pipe,
*12
Base
For Flush type
For Extended type
For Combination type
Low Pressure side: Process flange, Block
(Flange rating) (Test pressure) JIS 10K 2 MPa (290 psi) JIS 20K 5 MPa (720 psi)
*8
10 MPa (1450 psi)
*8
8 MPa (1160 psi)
*9
7 MPa (1000 psi)
*8
16 MPa (2300 psi)
*8
10 MPa (1450 psi)
*9
7 MPa (1000 psi)
*8
16 MPa (2300 psi)
*8
8 MPa (1160 psi)
*9
7 MPa (1000 psi)
*8
16 MPa (2300 psi)
3 MPa (430 psi)
3.5 MPa (500 psi)
Nitrogen (N
Retention time:
10 minutes
) Gas
2
Pressure test/ Leak test
Certificate
*11
EJX118B
EJX438B
JIS 40K ANSI/JPI Class 150 3 MPa (430 psi) ANSI/JPI Class 300 ANSI/JPI Class 300 ANSI/JPI Class 600 JIS 10K 2 MPa (290 psi) JIS 20K, 40K, 63K 3.5 MPa (500 psi)
For
ANSI/JPI Class 150
A-Capsule
ANSI/JPI Class 300, 600 JIS 10K 2 MPa (290 psi) JIS 20K 5 MPa (720 psi) JIS 40K JIS 40K JIS 63K
For B-Capsule
ANSI/JPI Class 150 3 MPa (435 psi) ANSI/JPI Class 300 ANSI/JPI Class 300 ANSI/JPI Class 600
*1: Not applicable with color change option. *2: Applicable for ush type (process connection style code W.) *3: The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specied by option code D1, D3, and
D4. *4: Specify the process operating temperature for zero correction. Example: Zero correction by process temperature 90°C. *5: Applicable for wetted parts material code SW, SE, SY, and HW. *6: Applicable for ushing connection ring code 1, 2, 3, 4, A, B, C, and D. *7: Applicable for ushing connection ring code 0. *8: Applicable for ush type (process connection style code W.) *9: Applicable for extended type and Combination type (process connection style code E and Y.) *10: Pure nitrogen gas is used for oil-prohibited use (option code K1 and K5.) *11: The unit on the certicate is always MPa regardless of selection of option code D1, D3, or D4. A ushing connection ring will not be
applied when conducting the pressure test or leak test. *12: Applicable for model EJX118B.
Code
P
X2
K1
K5
D1 D3 D4
TF1
R V
A1
M2W M5W
M2E
M2Y
T51 T54 T57 T52 T56 T55 T58
T51 T53 T52
*10
T53 T51 T54 T57 T55 T58 T52 T56 T55 T58
T14E.ai
IM 01C27H01-01E
<10. General Specications>
OPTIONAL ACCESSORIES
Product Part number Specication
Battery pack assembly F9915NQ Battery case, Lithium-thionyl chloride batteries 2 pieces Batteries
*1
Battery case F9915NK Battery case only Remote antenna cable F9915KU 3 m with mounting bracket
Antenna F9915KW 2 dBi standard antenna
*1: Alternatively, Tadiran SL-2780/S or TL-5930/S batteries can be purchased from your local distributor. *2: Use of high gain antenna is limited by local regulation of radio and telecommunication law. Consult Yokogawa for details.
F9915NR Lithium-thionyl chloride batteries, 2 pieces
F9915KV 13 m (3 m+10 m), with arrester and mounting bracket
F9915KX 0 dBi antenna F9915KY 6 dBi high gain antenna
*2
10-13
IM 01C27H01-01E
<10. General Specications>

10.4 Dimensions

10-14
<Transmitter body section> (Amplifier housing code 7)
122 (4.80)
*9
40
A B
For electrical connection code 5, 9, A, and D
6
(0.24)
76
(2.99)
(18.58)
*8
472
124 (4.88)
181 (7.13)
47
(1.85)
(1.57)
140
(5.51)
(4.53)
Mounting bracket (Flat-type, optional)
Integral indicator
115
<Diaphragm seal section>
Flush type
No ring (Flushing connection ring code 0)
n-øh
t
*3*4
f
25
(0.98)
*1
*2
ød
Unit: mm (approx. inch)
For EJX118B For EJX438B
Zero adjustment
(13.03)
*7
331
Ø110 (4.33)
Ground terminal
211 (8.31)
High pressure side
2-inch pipe
(O. D. 60 mm)
With ring (EJX118B: Flushing connection ring code 1, 2, 3, and 4) (EJX438B: Flushing connection ring code A, B, C, and D)
Diaphragm seal
*5
Flushing connection ring
191 (7.52)
(0.94)
39
(1.54)
*1
j
t
*3*4
f
24
(2.52)
k
64
Low pressure side
6*
211
91
(3.58)
)14.4(
ød
High pressure side
*2
Open to atmosphere Ø5 (0.20)
Low pressure side
C ø
øD
g ø
Capillary length
øD
n-øh
Drain/vent plug
C ø
Capillary length
*1: When wetted parts material code UW (titanium), value is 34 (1.34). *2: Indicates inside diameter of gasket contact surface *3: In case where process flange material is JIS S25C, value of f is 0. *4: In case where process flange material is JIS SUS304 in ANSI/JPI flange, value of f is included in t.
*5: Flushing connection ring
Straight type Reducer type
Spiral gasket
For flange size
3 or 2 inch
Spiral gasket
For flange size
44ø
1 1/2 inch
*6: When option code K1 or K5 is selected, add 11 mm (0.28 inch). *7: When amplifier housing code 8 is selected, the value is 390 mm (15.35 inch). When amplifier housing code 9 is selected, the value is 270 mm (10.63 inch). In both cases, the figures are shown as A or B accordingly. *8: When amplifier housing code 8 is selected, the value is 530 mm (20.87 inch). When amplifier housing code 9 is selected, the value is 410 mm (16.14 inch). In both cases, the figures are shown as A or B accordingly. *9: When amplifier housing code 8 or 9 is selected, add 1 mm (0.04 inch) to the value.
F11E.ai
IM 01C27H01-01E
Loading...