Process Calibrator
CA300 series
Process Calibrator
Source and Measure Simplicity
series
Bulletin CA300-EN
www.yokogawa.com/ymi
Specialized high performance model
for Loop Inspection!
Volt mA Calibrator
n Features
l Basic accuracy: 0.015%
(Source&Meas. accuracy of Voltage mA)
l 20mA SIMULATE (SINK) function
l Simultaneously supplies 24V loop power and measure output
signal with high accuracy
l HART/BRAIN comm. resistance (250Ω) embedded
l Sub display displays span% of the source value
l Corresponds to various types of source pattern
(Step sweep/ Linear sweep/ Manual step/ Span check)
Useful function installed
n Addition of sub display
The sub display additionally displays
span%, source value of voltage or resistance, while the main displays setting value.
n Corresponds to 2WAY
Power supply
Power is supplied by 2 ways :
AA Alkaline batteries or AC Adapter
AC Adapter is sold
separately
2
Source and Measure Simplicity Series
Specialized high performance model
for TC simulate and RTD simulate!
TC Calibrator
n Features
l Basic accuracy: 0.5°C (Typical of TC type K)
*Including accuracy of internal RJC
l Corresponds to 16 types of TC standard
(JIS/IEC/DIN/ASTM/GOST R)
l Sub display displays value of voltage source and span%
l Corresponds to various types of source pattern
(Step sweep/ Linear sweep/ Manual step/ Span check)
l Corresponds to other TC types by mV source function
l Measures TC sensor output as a thermometer
RTD Calibrator
n Features
l Basic accuracy: 0.3°C (Typical of PT100)
l Corresponds to 14 types of RTD standard (JIS/IEC/GOST R)
l Sub display displays value of resistance source and span%
l Corresponds to various types of source pattern
(Step sweep/ Linear sweep/ Manual step/ Span check)
l Corresponds to 2,3,4 wire. Realizes RTD simulation
l Measures output of RTD sensor as a thermometer
3
Supports efficient operation with various types of source pattern
n Step sweep function
Sources by 25% step automatically from 0% to 100% of span
which improves efficiency of operation. It can correspond to
various response time of field devices.
(15/30/45/60 seconds)
n Manual step function
Sources by 25% step manually from 0% to 100% of span.
n Linear sweep function
Sources continuously from 0% to 100% and is capable to
check meter and make linearity tests. Sweep time can be
selected by 15/30/45/60 seconds.
20mA
16mA
12mA
100°C
75°C
50°C
25°C
0°C
20mA
8mA
4mA
KEY
4-20mA Step sweep source example
100%
75%
50%
25%
0%
Selection: 15/30/45/60 sec.
0°C - 100°C Manual step source example
100%
75%
50%
25%
0%
Linear sweep source example
100%
n Span check function
Switches sources 0%ó100% by one touch. With this function, it makes it simple to make adjustment and to inspect
the open and close operation of valves.
4
4mA
20mA
4mA
Selection: 15/30/45/60 sec.
0%
4-20mA Span check example
100%
0%
KEY KEY