This manual provides the basic guidelines for
explosion protection type of ADMAG TI (Total
Insight) Series AXG and AXW magnetic owmeters.
For the items which are not covered in this manual,
read the applicable user’s manuals and general
specications as listed in IM 01E21A11-01EN
(Read Me First (Optional Code EC)). These
documents can be downloaded from the website of
YOKOGAWA. To ensure correct use of the product,
read these manuals thoroughly and fully understand
how to operate the product before maintaining it. For
method of checking the model and specications,
read the applicable general specications in
IM 01E21A11-01EN (Read Me First (Optional Code
EC)).
Website address: http://www.yokogawa.com/d/doc/
These manuals can be downloaded from the
website of YOKOGAWA or purchased from the
YOKOGAWA representatives.
NOTE
A CAUTION sign denotes a hazard. It calls
attention to procedure, practice, condition or the
like, which, if not correctly performed or adhered
to, could result in damage to or destruction of
part or the entire product.
An IMPORTANT sign denotes that attention
is required to avoid damage to the product or
system failure.
A NOTE sign denotes information necessary
for essential understanding of operation and
features.
CAUTION
IMPORTANT
NOTE
1
1
When describing the model name like “AXG###”
in this manual, “###” means any of the following.
For AXG###:
The following safety symbol marks are used in this
manual and product.
WARNING
A WARNING sign denotes a hazard. It calls
attention to procedure, practice, condition or the
like, which, if not correctly performed or adhered
to, could result in injury or death of personnel.
The following symbols are used in the product and
the manual to indicate the accompanying safety
precautions:
Protective grounding terminal
Functional grounding terminal (This terminal should
not be used as a protective grounding terminal.)
Alternating current
Direct current
Caution
This symbol indicates that the operator must read an
explanation in the user’s manual in order to avoid the
risk of injury or death of personnel or damage to the
product.
•
For the protection and safe use of the product
and the system in which this product is
incorporated, be sure to follow the instructions
and precautions on safety that is stated in user's
manual as listed in IM 01E21A11-01EN (Read
Me First (Optional Code EC)) whenever you
handle the product. Take special note that if you
handle the product in a manner that violated
these instructions, the protection functionality
of the product may be damaged or impaired. In
such cases, YOKOGAWA does not guarantee
the quality, performance, function, and safety of
product.
• Do not modify this product.
• The product should be disposed of in
accordance with local and national legislation/
regulations.
IM 01E21A03-02EN
<1. Introduction>
2
2
Regarding This User’s Manual
• This manual should be provided to the end
user.
• The contents of this manual are subject to
change without prior notice.
• All rights reserved. No part of this manual
may be reproduced in any form without
YOKOGAWA’s written permission.
• YOKOGAWA makes no warranty of any kind
with regard to this manual, including, but not
limited to, implied warranty of merchantability
and tness for a particular purpose.
• If any question arises or errors are found, or if
any information is missing from this manual,
inform the nearest YOKOGAWA sales ofce.
• The specications covered by this manual are
limited to those for the standard type under the
specied model number break-down and do not
cover custom-made products.
• Note that changes in the specications,
construction, or component parts of the
product may not immediately be reected in
this manual at the time of change, provided
that postponement of revisions will not cause
difculty to the user from a functional or
performance standpoint.
• This manual is intended for the following
personnel;
Engineers responsible for installation and wiring
of the product.
• To ensure correct use, read this manual and
the applicable user’s manuals as listed in IM
01E21A11-01EN (Read Me First (Optional
Code EC)) thoroughly before starting operation.
Read the general specications as listed in
IM 01E21A11-01EN (Read Me First (Optional
Code EC)) for its specication.
Trademark
• All the brands or names of Yokogawa
Electric’s products used in this manual are
either trademarks or registered trademarks of
Yokogawa Electric Corporation.
• All other company and product names
mentioned in this manual are trade names,
trademarks or registered trademarks of their
respective companies.
• In this manual, trademarks or registered
trademarks are not marked with ™ or ®.
For Safe Use of Product
For the protection and safe use of the product and
the system in which this product is incorporated,
be sure to follow the instructions and precautions
on safety that is stated in user's manual as listed
in IM 01E21A11-01EN (Read Me First (Optional
Code EC)) whenever you handle the product.
Take special note that if you handle the product
in a manner that violated these instructions, the
protection functionality of the product may be
damaged or impaired. In such cases, YOKOGAWA
shall not be liable for any indirect or consequential
loss incurred by either using or not being able to
use the product.
IM 01E21A03-02EN
<2. Explosion Protection Type>
2. Explosion Protection Type
3
3
WARNING
AXG### and AXW### magnetic owmeter
(Integral Flowmeter and Remote Sensor), and
AXG4A and AXW4A Remote Transmitter are
products which have been certied as explosion
protection type products if model code for
explosion protection is specied. Strict limitations
are applied to the structures, installation
locations, external wiring work, maintenance and
repairs, etc. of these products. Sufcient care
must be taken, as any violation of the limitations
may cause dangerous situations.
Be sure to read this manual before handling the
explosion protection type products.
WARNING
The terminal box cover and display cover are
locked by hexagon socket head cap screw. In
the case of opening the cover, use the hexagonal
wrench (nominal size 3). Read the Maintenance
Manual, IM 01E22A01-02EN or IM 01E24A0102EN, for the procedure. Before opening
the cover, be sure to check that the power of
owmeter has been turned off. Once the cover is
closed, be sure to re-lock the product.
Be sure to lock the cover with the screw by using
the hexagonal wrench after tightening the cover.
IMPORTANT
For multiple approval types:
(Transmitter Wiring Terminal: Clamp type)
For the installation of this transmitter, once a
particular type of protection is selected, any
other type of protection cannot be used. Apply a
permanent mark in the check box of the selected
approval type on the certication label on the
transmitter to distinguish it from unused approval
types.
2.1 Technical Data
Applicable Standard:
EN 60079-0: 2012+A11:2013, EN 60079-1: 2014,
EN 60079-7: 2015, EN 60079-11: 2012,
EN 60079-31: 2014
Certicate:
FM 17ATEX0031X
Integral Flowmeter
• Type of Gas Atmosphere Protection
Group: II
Category: 2G
Type of Protection:
Ex db eb ia IIC T6...T3 Gb
(Transmitter Wiring Terminal: M4 screw type)
Ex db eb ia IIC T6...T3 Gb
Terminal Compartment: Ex db or Ex eb
(Transmitter Wiring Terminal: Clamp type)
• Type of Dust Atmosphere Protection
Group: II
Category: 2D
Type of Protection:
Ex tb IIIC T75°C...T130°C Db
• Enclosure:
IP66/IP67 in accordance with EN 60529
• Maximum Surface Temperature:
See Table 2.1 and Table 2.2.
• Ambient Temperature:
See Table 2.1 and Table 2.2.
• Process Temperature:
See Table 2.1 and Table 2.2.
• Power Supply:
100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
24 Va.c. (50/60 Hz) / 24 Vd.c.
• Um: 250 V
• Current I/O: 4 to 20 mA, 32 Vd.c. max.
• Digital I/O: 30 Vd.c. max., 200 mA max.
IM 01E21A03-02EN
<2. Explosion Protection Type>
4
4
Remote Sensor
• Type of Gas Atmosphere Protection
Group: II
Category: 2G
Type of Protection:
Ex db eb ia IIC T6…T3 Gb
• Type of Dust Atmosphere Protection
Group: II
Category: 2D
Type of Protection:
Ex tb IIIC T75°C...T150°C Db
• Enclosure:
IP66/IP67 in accordance with EN 60529
• Maximum Surface Temperature:
See Table 2.1 and Table 2.2.
• Ambient Temperature:
See Table 2.1 and Table 2.2.
• Process Temperature:
See Table 2.1 and Table 2.2.
• Um: 250 V
Remote Transmitter
• Type of Gas Atmosphere Protection
Group: II
Category: 2G
Type of Protection:
Ex db IIC T6 Gb
(Transmitter Wiring Terminal: M4 screw type)
Ex db IIC T6 Gb or Ex db eb IIC T6 Gb
(Transmitter Wiring Terminal: Clamp type)
• Type of Dust Atmosphere Protection
Group: II
Category: 2D
Type of Protection:
Ex tb IIIC T75°C Db
• Enclosure:
IP66/IP67 in accordance with EN 60529
• Maximum Surface Temperature: T75°C
• Ambient Temperature: –40°C to +60°C
• Power Supply:
100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
24 Va.c. (50/60 Hz) / 24 Vd.c.
Table 2.2 Ambient Temperature and Process Temperature
5
5
Table No.
A-40°C to +60°C
B
C-40°C to +60°C
D
E
F
G-10°C to +60°C
H-10°C to +60°C
I
J-10°C to +60°C
Ambient
Temperature
-40°C to +45°CT6T75°C-40°C to +50°C
-40°C to +60°C
-40°C to +45°CT6T75°C-40°C to +50°C
-40°C to +60°C
-10°C to +45°CT6T75°C-10°C to +50°C
-10°C to +60°C
-10°C to +45°CT6T75°C-10°C to +50°C
-10°C to +60°C
-10°C to +45°CT6T75°C-10°C to +50°C
-10°C to +60°C
Temperature
Class
T6T75°C-40°C to +75°C
T5T90°C-40°C to +90°C
T4T120°C-40°C to +120°C
T3T130°C-40°C to +130°C
T5T90°C-40°C to +75°C
T4T120°C-40°C to +120°C
T3T130°C-40°C to +130°C
T6T75°C-40°C to +75°C
T5T90°C-40°C to +90°C
T4T120°C-40°C to +120°C
T3T150°C-40°C to +150°C
T5T90°C-40°C to +75°C
T4T120°C-40°C to +120°C
T3T150°C-40°C to +150°C
T5T90°C-10°C to +75°C
T4T120°C-10°C to +120°C
T3T130°C-10°C to +130°C
T5T90°C-10°C to +75°C
T4T120°C-10°C to +120°C
T3T150°C-10°C to +150°C
T6T75°C-10°C to +75°C
T5T90°C-10°C to +90°C
T4T120°C-10°C to +120°C
T3T130°C-10°C to +130°C
T6T75°C-10°C to +75°C
T5T90°C-10°C to +90°C
T4T120°C-10°C to +120°C
T3T150°C-10°C to +150°C
T5T90°C-10°C to +75°C
T4T120°C-10°C to +120°C
T3T130°C-10°C to +120°C
T6T75°C-10°C to +75°C
T5T90°C-10°C to +90°C
T4T120°C-10°C to +100°C
T3T150°C-10°C to +100°C
Maximum Surface
Temperature
Temperature
Process
IM 01E21A03-02EN
<2. Explosion Protection Type>
F0201.ai
Marking
F0202.ai
Marking
F0203.ai
Marking
6
6
2.2 Cable Entry
The type of cable entry is stamped near the cable
entry port according to the following codes.
MarkingScrew Size
MISO M20 x 1.5 Female
NASME 1/2 NPT Female
Integral Flowmeter Remote Sensor
Remote Transmitter
2.3 Installation
Read the Installation Manual, IM 01E22A01-01EN
(for AXG### and AXG4A) or IM 01E24A01-01EN
(for AXW### and AXW4A), for basic installation
procedure.
• All wiring shall comply with EN 60079-14, and
local electric codes and requirements.
• Unused apertures shall be closed with suitable
certied blanking elements.
(The plug attached is certied.)
• If the magnetic owmeter is mounted in an area
in the presence of combustible dust, it shall
be installed in such a way that the risk from
electrostatic discharges and propagating brush
discharges caused by rapid ow of dust is avoided.
• The sensor is not surrounded by pipe insulation
material.
• Cable glands, adapters and/or blanking elements
with a suitable IP rating shall be of Ex db IIC/Ex tb
IIIC or Ex eb IIC/Ex tb IIIC certied by ATEX and
shall be installed so as to maintain the specic
degree of protection (IP code) of the product.
• Take care the following warning marking
“POTENTIAL ELECTROSTATIC CHARGING
HAZARD”.
• In order to prevent the grounding conductor from
loosening, the conductor must be secured to the
terminal, tightening the screw with appropriate
torque. Care must be taken not to twist the conductor.
• For multiple types of protection for terminal
compartment, permanently mark the protection
type installed. Once the type is marked, it cannot
be changed.
• If the product is installed as the protection type Ex e,
terminate all the cable nish with crimp terminal of
a rod shape which of conductor length is 5 to 6 mm
and cross section is 0.8 to 2.5 mm2, and connect
them reliably.
• For the installation of multi protection type, tick the
box of the selected type of protection type on the
label in order to avoid confusion.
e.g. In the case of selecting “db”, not “eb”
Ex db eb ia IIC T6...T3 Gb
Ex tb IIIC T75°C...T130°C Db
Terminal Compartment: Ex db Ex eb
IM 01E21A03-02EN
<2. Explosion Protection Type>
F0204.ai
F0205.ai
F0206.ai
7
7
The grounding terminals are located on the inside
and outside of the terminal area.
Connect the cable to the grounding terminal in
accordance with wiring procedure (a) or (b).
When installation of explosion protection type
product, read installation manual, IM 01E22A0101EN (for AXG### and AXG4A) or IM 01E24A0101EN (for AXW### and AXW4A).
Integral Flowmeter, Remote Sensor and Remote
Transmitter
• Take care not to generate mechanical spark when
access to the product and peripheral devices in
hazardous locations.
• Take care the following warning marking
“POTENTIAL ELECTROSTATIC CHARGING
HAZARD”.
Take care the following warning marking when
opening the cover.
Integral Flowmeter and Remote Transmitter
• Take care the following warning marking
“AFTER DE-ENERGIZING, DELAY 20 MINUTES BEFORE OPENING”.
(a)
Remote Transmitter
(a)
(b)
Remote Sensor
• Take care the following warning marking
“DE-ENERGIZING BEFORE OPENING”.
2.5 Maintenance and Repair
Only personnel authorized by Yokogawa Electric
Corporation can repair the product.
For maintenance of explosion protection type
product, read maintenance manual, IM 01E22A0102EN (for AXG### and AXG4A) or IM 01E24A0102EN (for AXW### and AXW4A).
(b)
IM 01E21A03-02EN
<2. Explosion Protection Type>
F0207.ai
F0209.ai
2.6 Name Plate
Example for name plates of Integral Flowmeter,
Remote Sensor or Remote Transmitter.
Integral Flowmeter
*1
Remote Sensor
*1
F0208.ai
Remote Transmitter
8
8
*1
- MODEL: Specied model code
- SUFFIX: Sufx codes of the model code
- STYLE: Specied style code
- SIZE: Nominal size of apparatus
- METER FACTOR:
Sensor constant number of apparatus
- SUPPLY: Power supply voltage of apparatus
- OUTPUT: Output signal of apparatus
- FLUID TEMP.: Fluid temperature of apparatus
- FLUID PRESS: Fluid pressure of apparatus
- AMB. TEMP.: Ambient temperature
- NO.: Manufacturing serial number
- No.: FM 17ATEX0031X:
ATEX type examination certicate number
-
Protection type and temperature class for gas
Ex db eb ia IIC T6...T3 Gb
Ex db IIC T6 Gb
Ex db eb IIC T6 Gb:
- Protection type and maximum surface
temperature for dust
Ex tb IIIC T75°C...T130°C Db
Ex tb IIIC T75°C...T150°C Db
Ex tb IIIC T75°C Db:
- Um: Maximum r.m.s. a.c. or d.c. voltage
- ENCLOSURE: Enclosure protection code
- WARNING: Warning to apparatus
- : Name of manufacturer
*1: The product-producing country
IM 01E21A03-02EN
<2. Explosion Protection Type>
2.7 Specic Condition of Use
Integral Flowmeter, Remote Sensor and Remote
Transmitter
• Electrostatic charges on the non-metallic parts
(excluding glass parts) or coated parts of the
product shall be avoided.
• The ameproof joints differ from the standard
values in EN 60079-1. Only personnel authorized
by the manufacturer of the product can repair the
ameproof joints.
Integral Flowmeter and Remote Sensor
• The applicable temperature class, ambient
temperature range and process temperature
range of the product are shown in Table 2.1 and
Table 2.2.
• The property class of the fasteners used to fasten
the transmitter enclosure onto the neck part is at
least A2-70.
• In the case the electrodes and/or grounding rings
are made of titanium, the sensor should be kept
away from impacts and frictions in hazardous
locations.
• From the safety point of view, the intrinsically
safe circuit of the AXG and AXW series shall be
assumed to be connected to earth.
• The product shall be installed as overvoltage
category II.
9
9
Integral Flowmeter and Remote Transmitter
• Multiple types of protection for terminal
compartment, permanently mark the protection
type installed. Once the type is marked, it cannot
be changed. For the installation of multi protection
type, tick the box of the selected type of protection
on the label in order to avoid confusion.
IM 01E21A03-02EN
Revision Information
Title : ADMAG TI Series
AXG and AXW Magnetic Flowmeter ATEX Explosion Protection Type
Manual No. : IM 01E21A03-02EN
EditionDatePageRevised Item
1stOct. 2018—New Publication
10
IM 01E21A03-02EN