YOKOGAWA AQ2201, AQ2202 User Manual

User’s Manual
Yokogawa Electric Corporation
Notice of Alterations
IM 810518900-01E-31 1/3 for IM 810518900-01E 3rd Edition
Model 810518900 AQ2201/AQ2202 Frame Controller
Please make the following alterations to the User's Manual IM810518900-01E(see underlined text). This Manual can be used on products with firmware version 7. 01 or later. To determine the software version, press the [SYSTEM] key and then the “Information“. The version number is displayed under “Soft Version” in the Overview screen.
Page 1 Please note the underlined changes.
Manual Item Manual No. Description
AQ2201/AQ2202 Frame Controller IM810518900-01E This user’s manual. The manual describes all functions of User’s Manual the AQ2201/AQ2202, AQ2200-111, 141, 142, 201, 211, 215, 221, 231, 241, 311, 331, 411,
412, and 421 except for the communication functions, and proper operating procedures.
AQ2200 Multi-Application Test System IM810518900-17E This manual describes the communication functions Remote Command Reference Manual (remote control functions) of the AQ2201/AQ2202, AQ2200-111, 141, 142, 201, 211, 215, 221, 231, 241, 311, 331, 411,
412, and 421.
Page 1-16 Add “AQ2200-412 OSW Module”
11 12
9 10
15 16
13 14
5
43
2
1
AQ2200-412
OSW MODULE
3 4
1 2
7 8
5 6
A
A
1
16
Front and Side Views of AQ2200-412 OSW Module (1 x 16 type)
No. Name Function
1 Optical input/output part This port is connected to that you have selected in 2. (Common port)
2 Optical input/output part The port you have selected is connected to the common port described in 1. (Select port)
3 Button For locking of the lever
4 Lever Used to mount or remove the module.
5 Connector Connects the electric signals between the frame and module.
Page 6-19 Add “AQ2200-412 OSW Module”
AQ2200-412 OSW Module: Configuration with single OSW. OSW is provided “1 x 16”. This module is applicable only for SM fiber.
A
1 3
5 7 9
2 4
6 8
10
11
12
13
14
15
16
IM 810518900-01E-31 2/3 for IM 810518900-01E 3rd Edition
Page 6-20
Changing the Connection Port
················································· For “1 x 16”, “n” becomes “16”.
Page 10-22 OSW Module Standard Specifications
Number of ports: 1 x 4 or 1 x 8 or 1 x 16
················································· External dimensions:
····························· 1 x 16 type Approximately 62.5 (W) x 117 (H) x 321.5 (D) mm(not including projecting parts) Weight:
····························· 1 x 16 type Approximately 1.5 kg Accessories:
····························· 1 x 16 type: Seventeen dust proof caps (white)
Page 10-23 Add “AQ2200-412 OSW Module”
MODEL Suffix code Specification and Description
735143 Optical Switch (1×16)
Port configuration -16 1×16
Fiber -SA SMF (10/125)
Optical connector -FCC FC/PC connector
-SCC SC/PC connector
Page 11-9 Add “AQ2200-412 OSW Module”
Table 11-14 AQ2200-412 OSW Module Default Settings
Item Set Value
Route A-1
Display module name AQ2200-412 OSW MODULE
Loading...