Yokogawa 3213A Data sheet

MY10 Series of Analog Insulation Testers
Analog models with single rating
MY10-01:125V/20M MY10-02:250V/50M MY10-03:500V/100M MY10-04:500V/1000M MY10-05:1000V/2000M
AC voltage measurement
Automatic discharge
A wide choice of accessories
–Designed for shared use with the MY40
SERIES
Testing Performance Specifications
Model Rating
MY10-01 MY10-02 MY10-03 MY10-04 MY10-05
Standard test conditions:
Ambient temperature/humidity ranges:
23 ±5:/45-75% RH
Position of use:
Horizontal (5° max. of angle of inclination) Effect of geomagnetism: None Battery voltage: Within effective voltage range
(The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
125V/20M 250V/50M
500V/100M
500V/1000M
1000V/2000M
Effective
0.01–20M
0.01–50M
0.05–100M
0.5–1000M 1–2000M
Central Scale
Value
0.5M 1M 2M
20M 50M
Tolerances under the above-mentioned conditions:
Resistance measurement:
First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current:
1 mA (0 to 20%) when in first effective measuring
range Short-circuit current: 12 mA max.
AC Voltage
0–250V 0–300V 0–500V 0–500V
* The minimum value at which the rated voltage can be maintained
0–500V
Lower Limit of
Measured *
0.125M
0.25M
0.5M 1M 2M
Rated Current
0.5–0.6mA
0.5–0.6mA
3213A Series of Analog Insulation Testers
Analog models with single rating
AC voltage measurement and check live
lines such as motive power lines
One-touch operation Press-and-lock switch for
continuous measurement
A wide choice of accessories to meet various
testing requirements
Vibration- and shock-resistant hand-held
compact testers
Standard Accessories
Product Part Number Qty
1–1.2mA 1–1.2mA 1–1.2mA
Protection cover Shoulder strap Line probe Earth probe User's manual Batteries
93013 99005 98001 98002
– –
1 1 1 1 1 4
General Specifications
Scale length: Approx. 78 mm Battery life: Approx. 10 hours when continuously operated on
Batteries: Four AA(R6P) batteries Dimensions: Weight: Compliance:
manganese-oxide batteries with the pointer point­ing to the central scalevalue.
Approx. 125(w) ҂ 103(H) ҂ 53(D) mm, excluding protrusions
Approx. 400 g (main unit and batteries only, excluding accessories)
EN61010: 1993; EN61010-2-31: 1995 (over voltage cat­egory III, pollution Degree2 installations for indoor use).
SERIES
Testing Performance Specifications
Model Rating
321341 321342 321343 321344 321345
* The minimum value at which the rated voltage can be maintained; ** 0.55 mA in the case of the first effective measuring range
Standard test conditions:
Ambient temperature/humidity ranges:
23 ±5:/45-75% RH
Position of use:
Horizontal (5° max. of angle of inclination) Effect of geomagnetism: None Battery voltage: Within effective voltage range
(The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
100V/20M 250V/50M
500V/100M
500V/1000M
1000V/2000M
Effective
0.02–20M
0.05–50M
0.1–100M 1–1000M 2–2000M
Central
Scale Value
0.5M 1M 2M
20M 50M
Tolerances under the above-mentioned conditions:
Resistance measurement:
First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value Open circuit voltage: 130% max. of rated voltage Rated measuring current:
1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max.
AC Voltage
Measuring Range
0–150V 0–250V 0–300V 0–300V 0–300V
Lower Limit of
measured
0.1M
0.25M
0.5M
0.5M 1M
5
Rated
Current
1mA 1mA 1mA 1mA** 1mA**
General Specifications
Scale length: Approx. 88 mm Dimensions (main unit): Approx. 110 (W) ҂ 180 (H) ҂ 60 (D) (mm) Weight: Approx. 700 g including batteries, or approx. 1.2 kg in-
cluding hard case, handle, test leads and batteries
Batteries: Eight AA (R6P) batteries Accessories: See the list of accessories on the backside of this
bulletin for information on accessories such as probes with a switch.
Standard Accessories
Product Part Number Qty
Test lead Hard case Handle User's manual Batteries
98050 B9600HA B9303XE
– –
1 (consist of earth/line terminal)
1 (w/leads-housing case)
1 1 8
Loading...