YOKOGAWA 2100A, 2101A, 2181A, 2102A, 2182A User Manual

...
Bulletin 2100A-E
YOKOGAWA founded in 1915 is a world leader in the field of indicating & measuring instruments and industrial control instrumentation.
Suzhou Yokogawa Meter Company
Yokogawa Meters &
Instruments Corporation
Yokogawa started its business with analog meters
Yokogawa started its business with analog meters
and products have been widely used at various customers
and products have been widely used at various customers
such as industries, power plants, research laboratories
such as industries, power plants, research laboratories
and schools, etc.
and schools, etc.
Yokogawa provides you with high quality products
Yokogawa provides you with high quality products
with reliable trademark.
with reliable trademark.
CONTENTS
Switchboard Instruments .......................................................
Switchboard Instruments Line-up .........................................
Key to Switchboard Numbering System...............................
Accessories and Parts............................................................
Scale Forms and Divisions ....................................................
DC Ammeters, DC Voltmeters............ 2101A/2181A .............
AC Ammeters, AC Voltmeters............ 2102A/2182A .............
Wattmeters.......................................... 2105A/2185A .............
Varmeters ............................................ 2106A/2186A .............
3 4 5 6 7
9 11 13 16
Power Factor Meters .......................... 2107A/2187A .............
Frequency Meters............................... 2108A/2188A .............
Synchroscope..................................... 2109A.........................
Dimensions and Panel Mounting...........................................
Connection Diagrams .............................................................
ACCESSORIES ........................................................................
20 21 22 23 25 29
1
Usage Precautions
Safety instructions for Panel meters
Warning
Indicates usage precautions that must be read to ensure the safety of users and the equipment.
1. Usage environment and conditions
Do not use YOKOGAWA panel meters in locations such as the following:
• Locations where the ambient temperature is outside the range of 0 to 40°C
• Locations where relative humidity is outside the range of 25 to 80%
• Locations subject to vibrations or shock impact
• Locations subject to rain, dripping water, or direct sunlight
• Locations exposed to large amounts of dust, salt, soot, or corrosive gases (sulfurous acid gas, ammonia gas, hydrogen sulfide gas, or other gases that corrode metals or plastics)
• Locations subject to strong external noise or electro­magnetic waves
• Locations subject to large amounts of static electricity
• Locations subject to large amounts of high frequencies and waveform distortion (e.g., from inverters or thyristor circuits)
2. Mounting method
Adhere to safety rules at the construction, mainte­nance and inspection
•Check the appearance of the packing box and panel meters and confirm that there is no damage.
• Use the metal for mounting panel and ground it.
• If necessary, combine with washers and others and fasten, in the case of panel boards and switchboards are thin.
•Fasten nuts of mounting on boards to the proper torque for the size of screw being used with the proper tool. Recommended tightening torque : M3 screws - 0.6N·m
M4 screws - 1.2N·m M5 screws - 2.0N·m
3. Wiring
Adhere to the following rules when connecting the wires:
•When connecting an instrument with accessories, first make sure none of the wires are live.
•When connecting main power directly, install and use the proper fuse.
• The connector terminals on the wires should be appropriate for the electricity load and terminal size.
• Connect the wires properly as illustrated in the wiring diagrams of catalogs or on product labels.
• Attach to terminal cover for safety.
•Fasten terminal screws to the proper torque for the size of screw being used with the proper tool. Recommended tightening torque : M3 screws - 0.6N·m
M4 screws - 1.2N·m M5 screws - 2.0N·m
• Instruments that are combined with current transform­ers (CT) should be properly connected to the second­ary side of the CT. Improper connection may result in a CT failure, burned components, or a fire. When the secondary side of a CT is disconnected, especially
while the primary side is powered, the secondary side terminal will carry a high voltage which could result in electrical shock. Therefore, the secondary side should be short-circuited before the instrument is discon­nected.
4. Usage precautions
• Use the instruments at the front of mounting panel.
•Never touch the inside of mounting panel.
• Use the instrument within the rated specifications. Failure to do so can cause the equipment to malfunc­tion or result in a failure.
• While the power is on, do not touch any terminals or open the cover or case.
• The current transformer emits heat while powered, so do not touch it.
5. What to do if the equipment functions abnor-
mally or fails
• If you notice abnormal heating, or a strange odor, noises, or smoking or if the equipment seems to have failed, immediately take steps such as cutting off the input. Next, contact your YOKOGAWA sales office.
6. Maintenance and inspection
To ensure that your instrument operates properly, perform the following checks on a regular basis:
• Check for damage to the instrument or accessories due to heating or other factors.
•Check for loose attachments or screws (always turn off the power before doing this to ensure safety).
• The instrument covers have been coated with an antistatic agent to block static electricity. Gently wipe dirt off the cover surfaces with a soft, dry cloth. Do not use a wet cloth as this will reduce the effects of the antistatic coating. Do not allow cloths made from synthetic materials to contact the cover for an ex­tended period of time, and do not use benzene, paint thinner, or similar substances. Doing so may cause the cover to become deformed, discolor it, or cause cracking.
• If the indicator reading becomes unstable due to static electricity, coat the front and back of the cover with a commercially available antistatic agent.
• Instrument service life will vary according to usage conditions. In general, however, we recommend replacing the instrument after about 10 years of use.
7. Disposal of product
•Panel meters do not contain batteries.
• Dispose of panel meters as general industrial waste.
8. For aluminum electrolytic capacitors
Frequency meters use aluminum electrolytic capaci­tors. The lifetime of aluminum electrolytic capacitors are around 10 years when ambient temperatures are 23°C. If aluminum electrolytic capacitors run down and meters are damaged, replace new frequency meters.
2
SWITCHBOARD INSTRUMENTS
Yokogawa offers a complete line of switchboard instruments to
meet your every needs.
Model are available 110 mm and 80 mm square siz e 250° to mea-
sure all electrical quantities.
All switchboard instruments in the series feature rugged, friction
free and shock resistant taut-band suspension elements.
All model of AC instruments except 80 mm size wattmeters and varmeters are self-contained transducer needless external trans­ducer boxes.
The built-in transducer system offer many advantages including low cost, linear scales, greatly reduced volt-ampere loss.
Yokogawa switchboard instruments offer a variety Models, such as from single phase to three phase four wire instruments, as well as model for balanced and unbalanced circuits. All instr uments except synchroscope are complied with JIS C 1102.
110 mm square size switchboard instruments Se­ries. Plastic case with saf ety terminal protection cover .
Features
RMS rectifier type AC instruments
Platform scale --- No shadow on scale and readable, even
from sharp angles
Interchangeable scales save time
Easy to read linear scales and wide deflection angles
Taut-Band suspension --- eliminate friction and protects
against shock
Unti-framable case and terminal board
Provide terminal protect cover for safety
Specifications
In accordance with Japan Industrial Standard JIS C 1102: 2007
Accuracy --------------------------------- See next page
Full Scale Deflection Angle ---------- 250°(360° for Synchroscope)
Full Scale Length ---------------------- Approx. 196mm (7.7") for 110mm SQ
140mm (5.5") for 80mm SQ
Position of Use-------------------------- Vertical (Scale)
Pointer ------------------------------------ Lance type Pointer, Black
Operating Temperature Range ----- 0 to 40 °C
Operating Humidity Range ---------- 25 to 80 %RH
Storage Temperature Range -------- –10 to 50°C
Storage Humidity Range ------------- 25 to 80 %RH
Dielectric Strength --------------------- Between electrical circuit and the case: 3320V AC for 5 seconds
Between current circuit and voltage circuit: 2600V AC for 5 seconds For Wattmeters, Varmeters and Power factormeters (2000V AC for 2185A, 2186A and 2187A)
Insulation Resistance ----------------- More than 10 MΩ/500V DC between electrical circuit and the case, current circuit and voltage circuit.
More than 5MΩ/500V DC between current circuit and voltage circuit. For Wattmeters, Varmeters and Power factormeters
Safety Requirements------------------ Structural requirements are in accordance with JIS C 1010 for safety of voltage test, insulation and other. Reinforced insulation, between electrical circuit and case Indoors, Altitudes up to 2000m, Pollution degree 2 Measurement category III (Measurement category is not applied for non- JIS products.) Maximum working voltage:600V
80 mm square size miniature switchboard instru­ments series high space utility.
Type 2101A to 2109A
Type 2181A to 2188A
Measurement Category
Measurement Category CAT.I
CAT.II
CAT.III
CAT.IV
For measurements performed on circuits not
Description
directly connected to MAINS. For measurements performed on circuits directly connected to the low voltage installation. For measurements performed in the building where distribution panels and circuit breaker, etc are installed. For measurements performed at the source of the low-voltage installation.
Remarks
Appliances, portable equipments, etc. Distribution board, circuit breaker, etc.
Overhead wire, cable systems, etc.
3
Entrance Cable
CAT.IV
Internal Wiring
Distribution Board
CAT.I
Fixed Equipment, etc.
CAT.III
CAT.II
T
Equipment
Outlet
SWITCHBOARD INSTRUMENTS LINE UP
Name
DC AMMETERS / VOLTMETERS DC SUPPRESSED METERS
AC AMMETERS / VOLTMETERS
Single phase 2-wire Single phase 3-wire
WATTMETERS
VARMETERS
POWER FACTOR METERS
3-phase 3-wire
3-phase 4-wire
Single phase 2-wire
3-phase 3-wire
3-phase 4-wire
Single phase 2-wire
3-phase 3-wire
3-phase 4-wire
(Unbalanced) (Balanced) (Unbalanced)
(Balanced) (Unbalanced) (Balanced) (Unbalanced)
(Balanced) (Unbalanced) (Unbalanced)
Operating Princile
Moving coil type
RMS rectifier type
Mean rectifier type
Feedback time division multiplier type
Feedback time division multiplier type
Phase defection type
Feedback time division multiplier type
Symbol
Accuracy
1.5
1.5
2.5
1.5
1.5
5.0
Model
110mm SQ 2101A30 2101A35,36,37
2102A30
2102A31
2105A31 2105A32 2105A35 2105A34 2105A36 2106A31 2106A33 2106A35 2106A34 2106A36 2107A31 2107A33 2107A35 2107A36
80mm SQ 2181A00 2181A35,36,37
2182A00
2182A01
2185A31(*1) 2185A32(*1) 2185A35(*1) 2185A34(*1) 2185A36(*1) 2186A31(*1) 2186A33(*1) 2186A35(*1) 2186A34(*1) 2186A36(*1) 2187A31 2187A33 2187A35(*1) 2187A36(*1)
FREQUENCY METERS
SYNCHRO­SCOPE (*2)
Note: *1: Attached external transducer box. *2: not complied with JIS standard.
Single phase 3-phase
Differential type
Moving Magnet type
0.5
1.0
2.5
2108A30
2109A30
2188A30
4
KEY TO SWITCHBOARD NUMBERING SYSTEM
[Model/Suffix Code]
21
앮앮
(A)
앮앮
앮앮앮
-
- 앮 - L -
앮앮
Model
110 SQUARE
2101A 30 2101A 35
2102A 30
2102A 31
2105A 31
2106A 31
2107A 31
2108A 30
2109 31
Rating
Refer to Suffix Code
Designation of Frequency Used
N A B C
Pointer
L Lance type pointer
Cover color and Set pointer
BL BG BS GS
80 SQUARE
2181A 00
2181A 35 36 37
2182A 00
2182A 01
2185A 31 32 34 35 36
2186A 31 33 34 35 36
2187A 31 33 35 36
2188A 30
33
Always "N" or 50/60Hz Common 50Hz 60Hz 400Hz
Munsell N1.5 Munsell 7.5BG4/1.5 Munsell N1.5 with Set pointer (red color) Munsell 7.5BG4/1.5 with Set pointer (red color)
* Specify Full scale value and Unit
DC AMMETERS,DC VOLTMETERS DC AMMETERS ,VOLTMETERS
36
SUPPRESSED METER
37
AC AMMETERS ,VOLTMETERS RMS rectifier type AC AMMETERS ,VOLTMETERS Mean rectifier type
32 34
WATTMETERS
35 36
33 34
VARMETERS
35 36
33
POWER FACTOR METERS
35 36
FREQUENCY METERS SYNCHROSCOPE
5
[EX.]
Model
110 SQUARE AC AMMETERS
Rating
0 to 5A
Full scale value
and Unit
0 to 100A
Designation of
Frequency Used
50/60Hz Common
2102A30-A42-N-L-BL
ACCESSORIES AND PAR TS
Model
1set (Specify Model and suffix codes, Full scale value
Standard Scale Plate
Blank Scale Plate (With YOKOGAWA mark)
Cover
110 SQUARE
80 SQUARE
Terminal Cover (6 Terminal) Terminal Cover (5 Terminal) Terminal Cover (3 Terminal):(For 80 SQUARE) Shunt lead
Cover with Set pointer
Cover Cover with Set
pointer
(Black) (Blue Green) (Black) (Blue Green) (Black) (Blue Green) (Black) (Blue Green)
219900
219900/001
219930-11 219930-12 219930-13 219930-14 219930-31 219930-32 219930-33 219930-34 219930-22 219930-21 219930-23 219930-24
and unit,VT ratio and CT ratio) EX.: 2101A36-AHE-N-L-BL 0 to 250kPa 1set (Specify Model and suffix codes, and Blank scale) EX.: 2101A36-AHE-N-L-BL Blank scale 1 pce 1 pce 1 pce (Set pointer is red) 1 pce (Set pointer is red) 1 pce 1 pce 1 pce (Set pointer is red) 1 pce (Set pointer is red) 10 sheets (up side) 10 sheets (down side) 10 sheets Round Resits 0.05 less, For M4 terminal, 1.5m 1set
Pointer
Lance type pointer
0 to 100A
Descriptions
Cover color and
Set pointer
Munsell N1.5
6
SCALE FORMS AND DIVISIONS
Maximum
scale value
3.5 35
350
3500
7
70
700
7000
2
20
200
2000
±1
±10
±100
±1000
2.5 25
250
2500
3
30
300
3000
±1.5
±15
±150
±1500
Maximum
Divisions
scale
Divisions
value
35 Division
7.5 75
750
7500
40 Division B
4.5 45
450
4500
9
90
900
9000
50 Division B 50 Division C 60 Division A
±2.5
±25
±250
±2500
±5
±50
±500
±5000
60 Division B
1.5 15
150
1500
37.5 Division
45 Division
75 Division
For 210 A 110mm only
Maximum
scale value
4
40
400
4000
8
80
800
8000
±2
±20
±200
±2000
±4
±40
±400
±4000
1
10
100
1000
5
50
500
5000
1.2 12
120
1200
6
60
600
6000
±3
±30
±300
±3000
±6
±60
±600
±6000
1.5
15
150
1500
Divisions
40 Division A
50 Division A
30 Division
For 218 A 80mm only
Note 1. This standard scale divisions are applied to 2101A, 2102A, 2105A, 2106A, 2181A, 2182A, 2185A and 2186A.
2. Numerals are indicated to the major line (▼).
3. All scales divisions are linear distribution.
4. To be applied this standard scale division, when specify special maximum value.
•not standard maximum scale value (Ex.) 2300 --- 46 divisions
•minimum scale value are not zero (Ex.) 50 to 100 --- 50 divisions
7
SCALE FORMS AND DIVISIONS
For Suppressed meter 2101A, 2181A
For Expanded scale 2102A, 2182A voltmeter
Ex. 70 to 130V=245°
For Frequency meter 2108A, 2188A
Ex. 45 to 55Hz
1
80
46
0
70
48
45
90
Extended scale Ammeters
2
3
4
5
3
m
s
2102A, 2182A (Ex.)100A 2 times
Red line and numerals for extended portion (Ex. 2 Times 150 and 200A) 3 Times -- 2 and 3 Times 5 Times -- 3 and 5 Times
100
110
For Power Factor meter
120
130
V
2107A, 2187A
60
40
20
0
A
1.0
.9
LEAD LAG
.7
.5
COS
80
100
150
200
.9
.7
.5
50
52
For Synchroscope 2109A
SLOW
FAST
54
Hz
55
SYNCROSCOPE
Single division/Double numerals Ex. 0 to 5/0 to 10A (50 Div.) All div.line and numerals are black. Size of numerals are different high. Apply same division only.
Kinds of division lines
1. Kinds of division lines
Medium line Minor line Major line (with numerals)
2. 3 characters, standard. EX. (1) 1200V → 1.2kV
(2) 20000rpm 20 × 1000rpm
4
2
2
1
0
6
3
8
4
10
A
5
Double division/Double numerals Ex.0 to 300/0 to 450 m/min (60 Div./45 Div.) Outer -- Black line and
numerals
Inner -- Red line and
numerals
10
5
0
20
10
m/min
15
30
20
30
45
25
40
8
2101A/2181A
DC AMMETERS
-AEG
-AEM
-AFA
-AFN
-AFX
-AGZ
-AHM
-AHY
-AJR
-AKG
-AKM
-ALA
-ALC
-ALE
-ALJ
-ALS
-AMF
-AMT
-AND
-ANG
-ANL
-A00
-D00
-A01
-A04
-A05
-D00
-A06
Suffix Codes
-N
-L
-BL
-BG
-BS
-GS
110 SQUARE Class 1.5 80 SQUARE Class 1.5 0 to 300 microA (Approx. Internal Resistance : 1,050 ohm) 0 to 500 microA (Approx. Internal Resistance : 630 ohm) 0 to 1mA (Approx. Internal Resistance : 185 ohm) 0 to 3mA (Approx. Internal Resistance : 17 ohm) 0 to 5mA (Approx. Internal Resistance : 10 ohm) 0 to 10mA 0 to 30mA 0 to 50mA 0 to 100mA 0 to 300mA 0 to 500mA 0 to 1A 0 to 1.5A 0 to 2A 0 to 3A 0 to 5A 0 to 7.5A 0 to 10A 0 to 15A 0 to 20A 0 to 30A 0 to (300 microA to 1A), Optional intermediate rating
-a to 0 to +b where a or less 72% × (a+b), a+b=1mA to 2A For zero-center and similar scale meter 0 to 50mV, For external shunt use 0 to 60mV Specify scale range 0 to 100mV (No shunt is manufactured)
-a to 0 to +b (b=50mV) where a or less 50mV, For zero-center and similar scale meter 0 to 50mV, Meter with VR, 0 to 2 ohm Variable
Always "-N" Lance type pointer (Black), Always "-L"
Munsell N1.5 Munsell 7.5BG4/1.5 Munsell N1.5 with Set pointer (red color) Munsell 7.5BG4/1.5 with Set pointer (red color)
  
Model 2101A 30 2181A 00
Rating
Designation of Frequency Used Pointer Cover color and Set pointer
SPECIFY THE FOLLOWING WHEN ORDERING
(1) Model and Suffix codes (2) Full scale value and unit (3) For suffix code A00 or D00, specifiy rating and full scale value.
Descriptions
           
(Voltage Drop : 50mV)
            
Notes :
(1) Scale other than Yokogawa' standard format will be special order. (2) For each meter with the rating of 50mV,60mV or 100mV, one-pair(1.5m) of shunt leads are supplied. (3) External shunts are not supplied.
9
Loading...
+ 25 hidden pages