Yellow Jacket 69341 Operating Manual

YELLOW JACKET
H2 Tracer Gas Leak Detector
Model 69341
Detects 5% H2 in 95% Nitrogen Tracer Gas
®
Operations Manual
INTRODUCTION
The YELLOW JACKET H life, solid-state heated sensor technology that is designed to detect
/Nitrogen Tracer Gas mixture
H
2
The H used with the H will detect leak rates less than 5 ppm. This complies with standards EN35422 and EN14624. The Tracer Gas mixture complies with Article 6, Paragraph 3 of EU Directive 2006/40/EC.
Leak Detector does not require rechargeable batteries. When
2
/Nitrogen Tracer Gas mixture, the H2 Leak Detector
2
Hand-held Leak Detector features a long
2
FEATURES
H2 sensitivity <5 ppm
Low battery indicator
CE Certified
Long life, stable sensor
Automatic calibration and reset
to ambient
3 adjustable sensitivity levels
18 month warranty
Made in USA
2
True mechanical pump
Uses 4 AA alkaline batteries
Leak Detector Control Panel
H
2
Low battery indicator
Low Battery
Sensitivity level indicator
Indicator
Sensitivity Level
Sensitivity adjust
Power On/Off
Operating Instructions
1. TURN ON: Press the ON/OFF button once to turn on and again to turn off. NOTE: Hold button down for approximately 1 second to turn unit off.
2. WARM UP: The detector automatically starts heating the sensor. During the heating cycle, the detector will sound a slow “beep”. Warm up is usually less than 20 seconds.
3. READY: The detector is ready to begin searching for leaks when the the green Norm sensitivity LED turns on and the audio “beep” increases in frequency.
3