Yale YRD410, YRD420 Installation Manual

Page 1
Yale Assure Lock® 2 Keyed Deadbolt Installation Guide
(Keypad YRD410 or Touchscreen YRD420)
Notice: Before installing your lock, be sure to follow the steps on the yellow Quick Start Guide.
Tools Needed
Tools Needed To Adjust An Existing Door
or Prep a New Door
Standard Phillips
Failure to follow these instructions could result in damage to the product, voiding the factory warranty and could lead to failure of the product to provide access.
Drill Utility
Knife
1
Pencil
Wood
Mortise Chisel
Tape
Measure
Level
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 2
Door Thickness
DoorSense
Yale Smart Module
(with select models)
In The Box
Guide
Hardware Components
DoorSense
Screws
Flush Mount Cap
Mounting Tape
Housing
Cover
Adjustable Deadbolt
Latch (AYRDB DRIVE
Adjustable Drive-In Deadbolt
Latch available for purchase)
Strike
Plate
Battery Cover
AA
AA
AA
AA
x4
Batteries
Exterior Keypad
Interior Lock
x2
Screws and
Plastic Clips
(pre-installed)
Mounting Plate
2
Key
Reset Pin
x4
Strike Plate
and Deadbolt
Screws x20mm
x2
Screw Set B
Blue for
1-3/8"
Door Thickness
x2
Screw Set C
Black for
Standard
1-3/8" - 1-3/4"
Note: You must use the provided screws from the
hardware pack when installing this lock.
x2
Screw Set D
Silver for
2" - 2-1/4"
Door Thickness
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
x2
Optional Security
Strike Plate
Screws
Page 3
1
Remove Existing Deadbolt
Keep your old deadbolt until your new lock has been successfully installed.
Door
Frame
3
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 4
2
67
FOLD OVER DOO R E DGE
Centerline
Center of 1" (25mm) hole through edge of door
For 1-3/8"
35mm()
Thick Door
2-3/8" 60mm Backset()
2-3/4"70mm Backset()
For 1-3/"4
mm(44.5 )
Thick Door
Center of 2-1/8" (54mm) hole through face of door
Center of 2-1/8" (54mm) hole through face of door
Center of 1" (25mm) hole through edge of door
Door
CAUTION:
If printed from electronicfile,
Measurea dimension
to check scale.
set print scale to 1:1
Check Door Measurements and Adjust If Needed
1/8 3/8 5/8
7/8
1/8 3/8 5/8
7/8
1/8 3/8 5/8
7/8
Check Door:
Tear off the Door Checker page of this guide and follow instructions to verify your door measurements and make any needed adjustments.
Note: There are some cases where existing holes cannot be adjusted to be compatible.
New Door:
Tear off the Template page of this guide and use either 21/8" or 11/2" template to prepare a new door that has no holes or to adjust existing holes to be compatible.
1/4
1/4
3/4
1/21/2 1/2
0123
I
B
BlueCBlackDSilver
Check Your Door Guide
To ensure a successful installation, measure each aspect of your door and frame, as shown in panels (left side of sheet) using the ruler above. Make sure all of your dimensions are a . See letter definitions below for guidance.
A. 2" Minimum clearance between top of
existing lever/knob rose (trim) and center of deadbolthole. 2" tolerance for optimal Door Sense location.
B. 1-3/8" DoorThickness se blue Screw; u
Set B (shortest set).
C. 1-3/8" - 1-3/4" DoorThickness; use black
Screw SetC.
3/4
G
1/4
3/4
A
H
EF
D.2" - 2-1/4" Door Thickness; use
silver Screw Set D (longest set).
E; u. 2-3/8" Backset se Out of Box latch
setting.
F. 2-3/4" Backset; adjust latch setting.
Instructions on how to adjust the latch are included in manual.
1/8 3/8 5/8 7/8 1/8 3/8 5/8 1/8 3/8
1/4 3/4 1/41/4
1/21/2
7/8
3/4
1/2
45
CAUTION:
If printed from electronic file,
set print scale to 1:1.
Measure ruler to check scale.
G.1-1/2" Face Bore Diameter. Instructions
on how to remove the black adapter from the lock are included in manual. 1-1/2"tolerance from inside door frame edgefor optimal DoorSense location.
H. 2-1/8" Face Bore Diameter.
I. Edge Bore Diameter and Depth.
Cross Bore Diameter.
3/4
7/85/8
1/8 3/8 5/8 7/8
1/4 3/4
1/2
4
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 5
Greater than A
Less than A
X
(Your door is not a match for aYale smart lock)
Verify Measurements with the Check Your Door Guide
Measure Clearance
Measure Door Thickness
B, C, or D
Less than B
X
(Your door is not
a match for a
Yale smart lock)
Greater than D
X
(Your door is not a match for a Yale smart lock)
Measure Backset
Equals E or F
Less than E or F
X
(Your door is not
a match for aYale smart lock)
Greater than E or F
X
(Your door is not
a match for aYale smart lock)
Backset
2- /8" ( mm)360
or
2-3/4" (70mm)
Cut Here
Measure Face Bore
Equals G or H
Less than G
X
(Adjust diameter to G or H)
Greater than H
X
(Your door is not
a match for a
Yale smart lock)
2- /8" ( mm)154
OR
1-1/2" (38mm)
Measure Cross Bore
Equals I
Less than I
X
(Adjust diameter to 1")
Greater than I
X
(Your door is not
a match for a
Yale smart lock)
1"
(25mm)
Dia.
MeasureStrike Pocket
Diameter and Depth
Equals I
Less than I
X
(Adjust diameter and depth to 1")
Greater than I
X
(Your door is not
a match for a
Yale smart lock)
1" (25mm) Dia.
1" (25mm) Deep
5
Frame
Recommended Location
of DoorSense
A: Within 2" of Yale logo on battery cover.
G: Within 1-1/2" from inside frame edge.
38(mm)
"2
51(mm)
"1-1/2
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 6
Check Your Door Guide
1/4
1/8 3/8 5/8
3/4
7/8
0123
1/4
1/8 3/8 5/8
3/4
7/8
1/4
1/8 3/8 5/8
3/4
7/8
1/21/2 1/2
I
B
BlueCBlackDSilver
EF
45
1/21/2
1/4 3/4 1/41/4
1/2
1/8 3/8 5/8 7/8 1/8 3/8 5/8 1/8 3/8
A
A. 2" Minimum clearance between top of
existing lever/knob rose (trim) and center
of deadbolt hole.
2" tolerance for optimal Door Sense
location.
B. 1-3/8" Door Thickness se blue Screw; u
Set B (shortest set).
C. 1-3/8" - 1-3/4" DoorThickness; use black
Screw Set C.
D. 2" - 2-1/4" Door Thickness; use
silver Screw Set D (longest set).
E; u. 2-3/8" Backset se Out of Box latch
setting.
F. 2-3/4" Backset; adjust latch setting.
Instructions on how to adjust the latch are included in manual.
G. 1-1/2" Face Bore Diameter. Instructions
on how to remove the black adapter from the lock are included in manual.
1-1/2"tolerance from inside door frame edgefor optimal DoorSense location.
H. 2-1/8" Face Bore Diameter.
I. Edge Bore Diameter and Depth.
Cross Bore Diameter.
H
3/4
7/8
67
1/2
1/4 3/4
1/8 3/8 5/8 7/8
3/4
7/85/8
CAUTION:
If printed from electronic file,
Measure ruler to check scale.
set print scale to 1:1.
G
To ensure a successful installation, measure each aspect of your door and frame, as shown in panels (left side of sheet) using the ruler abo ve. Make sure all of your dimensions are a . See letter definitions below for guidance.
6
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Cut Here
Page 7
Template to Mark a Door for 21/8" Face Bore
FOLD O VER DOOR
EDG E
Centerline
Center
of 1" (25mm)
hole through edge of door
For 1-3/8"
35mm()
Thick Door
2-3/8" 60mm Backset()
2-3/4" 70mm Backset()
For 1-3/ "4
mm(44.5)
Thick Door
Center of 2-1/8" (54mm) hole through face of door
Center of 2-1/8" (54mm) hole through face of door
Center
of 1" (25mm)
hole through
edge of door
Door
CAUTION:
If printed from electronic file,
Measure a dimension
to check scale.
set print scale to 1:1.
Cut Here
7
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 8
For 1-3/ "4
mm(44.5)
Thick Door
Center
of 1" (25mm)
hole through edge of door
Center
of 1" (25mm)
hole through edge of door
For 1-3/8"
35mm()
Thick Door
Template to Mark a Door for 11/2" Face Bore
2-3/4" 70mm Backset()
EDG E
Centerline
FO LD OVER DO O R
2-3/8" 60mm Backset()
8
Center of -1/"12 ( mm)38 hole through face of door
If printed from electronic file,
set print scale to 1:1.
Measurea dimension
Center of -1/2"1 ( mm)38 hole through face of door
CAUTION:
to check scale.
Door
Cut Here
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 9
3
2-3/
8
2-3/
8
2-3/
4
x2
For Deadbolt
Latch
(Actual Size)
x2
For Strike Plate
(Actual Size)
Install Deadbolt Latch and Strike Plate
*Correct deadbolt latch length is based on backset. Choose 23/8" or 23/4".
23/8"Backset, Out of Box
To Adjust: Twist neck while holding body stable.
23/4" Backset, optional
Door Checker measurements E and F can help you verify your backset measurement.
Security screws can be used here, in place of the small strike plate screws.
Align
strike
with
ame
Fr
deadbolt
latch
If the deadbolt latch is extended,
flathead screwdriver to rotate slot
Deadbolt latch must be
in unlocked position. UP
arrow must face upwards.
Door
use your fingers or a small
until deadbolt latch is retracted.
*Backset
9
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 10
4
Adapter Screws
Verifying Bore Face Measurement for Exterior Keypad
Install the lock with the door open.
Do not close until all steps are completed. Measurement G on the Door Checker will help verify your bore face measurement.
If hole is less than 21/8", remove adapter by unscrewing the two screws on either side, using a Phillips #2 screwdriver.
Top of Adapter
2 screws installed here, one on each side
Inside of Door Outside of Door
Ensure deadbolt latch is
unlocked to allow tailpiece to
slide through deadbolt latch.
See Step 3, if not.
Once confirming your bore face measurement is correct, you are ready to install the Mounting Plate and Keypad.
10
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 11
5
Bolt Set C, Black
x2
foraStandard
1-3/8" - 1-3/4"
Door Thickness
Install Mounting Plate and Exterior Keypad
Inside and Outside of Door
IMPORTANT:
There are 3 bolt sets with your
lock. Choose the bolt length for
your door thickness.
Measurement B, C, or D on
the Door Checker will help you
identify which bolts to use.
13/8" Door Thickness;
use blue Screw Set B
(shortest set)
13/8" - 13/4" Door Thickness;
use black Screw Set C
2" - 21/4" Door Thickness;
use silver Screw Set D
(longest set)
Position keypad on the outside of door, feeding wire as shown.
Hold keypad to front of door, while positioning plate to inside of door.
Guide wire through the ‘front wire hole’ in plate.
Insert 2 bolts through the plate.
Hand tighten bolts with a Phillips screwdriver, ensuring plate and keypad are straight.
Use Phillips screwdriver when attaching mounting plate bolts to keypad.
Keypad
Wire
Front Wire
Hole
11
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 12
6
Attach Wire to Inside of Interior Lock
Ridges face outward
Make sure wire is
attached securely.
12
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 13
7
Hook
Spring
Latch
Thumbturn
Slot
Tailpiece
Thumbturn
Lock
Install Interior Lock
Tailpiece must be horizontal.
Thumbturn must be vertical.
Insert tailpiece into the slot.
Push the lock towards the door, adjusting the position until the plate spring latch ‘clicks’ into place and holds the bottom of the lock.
Screws are pre-installed. Tighten
when lock is seated on plate.
When fully tightened, lock should
13
be flush to door.
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 14
Test Thumbturn and Key
Smooth deadbolt latch operation will enhance your battery life.
If deadbolt latch does not lock or unlock when turning thumbturn:
Ensure tailpiece is inserted into deadbolt latch slot. Step 4
Ensure tailpiece is inserted into thumbturn slot. Step 7
14
If deadbolt latch does not lock and unlock when key is turned:
Ensure deadbolt latch is centered in face bore hole. Step 3
Ensure tailpiece is inserted into deadbolt latch slot. Step 4
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 15
S
Select
Models
Install Yale Smart Module
Included with select models
Batteries must not be installed
when inserting or removing
Yale Smart Module.
15
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 16
8
1st
2nd
Install Batteries and Replace Cover
Place ribbon behind
batteries for easy
battery removal.
Deadbolt latch must
be unlocked before installing batteries.
Pink Light and Audio Sounds
Successful Power up
Congratulations, you’ve installed the Yale Assure Lock® 2 Keyed Deadbolt!
The numbers will begin to light up in a
clockwise motion. Once this happens, the
lock is in pairing mode and can be set up
using the Yale Access App.
Try to connect your lock quickly as this mode
will turn off after 5 minutes. After 5 minutes,
simply touch the Yale logo to re-start the
16
connection to the app.
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 17
9
Installing DoorSense®
Surface Mount Installation
Installation options:
1. Surface Mount: Only requires only the use of a screwdriver.
2. Flush Mount: Provides a cleaner and less visible look with more robust performance, but does require drilling a ⅝" hole into your door frame.
What’s in the box?
DoorSense
Screws
Flush Mount
Cap
Mounting Tape Housing Cover
What you’ll need
Phillips Screwdriver
Step 1. Determine mounting location
For optimal performance, DoorSense should be mounted within 1.5" from the edge of your door frame, and align with your lock’s Smart Module (if you are installing one).
Ensure it is in the proper position with its center aligned
with the Yale logo.
1.5"
2"
17
Door Frame
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 18
9
Installing DoorSense®
Step 2. Attach mounting tape
A. Remove one side of the adhesive.
B. Attach tape to the
back of the DoorSense, ensuring it is aligned with the edges of the device and screw holes.
C. Remove the remaining piece of adhesive.
Step 3. Place on door frame
Press the adhesive side to the frame.
18
Door
Frame
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 19
9
Installing DoorSense®
Step 4. Screw into frame
Hand tighten to the frame using the included screws.
You may wish to complete this step after your lock is set up and calibrated to ensure you are able to retrieve accurate door state readings before modifying your door frame.
Step 5. Attach the cover
Press the cover onto the DoorSense unit.
Notes: Once the lock has been set up, navigate to the Lock Settings and select Calibrate Lock.
Follow the instructions in the app. Open and close the door to validate the door state is
accurate. If it is not accurate or the calibration was unsuccessful, relocate the DoorSense closer to the smart lock and repeat the calibration process until you get accurate results.
If you elected to not insert the screws into the door frame, go back and secure them into your door frame or wall. Place the cover over the housing.
If you notice that your readings are not accurate over time, perform another Calibration.
19
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 20
9
Installing DoorSense®
Flush Mount Installation
What you’ll need
• Flush Mount Cap (shown in illustration on page 16.)
• 5/8" drill blade bit • Electric drill
B. Press the cap onto the notched side of the magnet carrier.
The two shapes should interlock.
Clips
Notches
Step 1. Remove magnet from the housing
Use a small blunt object to push the magnet carrier out of the housing.
This may require some force.
Step 2. Assemble magnet to cap
A. Expose the adhesive
by removing the blue backing.
Magnet Carrier
Magnet
PUSH
Blue Backing
Adhesive
Step 3. Determine mounting location
DoorSense is mounted 1.5" at most from the top edge of the strike plate and centered on the door frame.
Door
Door
Frame
DoorSense 5/8" Hole
1.5"
1.5"
Strike Plate
20
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 21
9
Installing DoorSense®
Step 4. Tape drill bit
It may be helpful to attach tape to your drill bit to mark the proper depth of hole to drill.
Although DoorSense requires a 1/2" deep hole, it may be helpful to use the assembled DoorSense Flush Mount as a guide.
Step 5. Drill hole
Drill the hole in the proper location on your door frame.
Door
Frame
5/8
Tape set at 1/2"
Depth Mark
Step 6. Insert DoorSense into the hole
If it is too snug to push in by hand, protect the frame with a piece of scrap wood and use light blows with a hammer or mallet.
Door
Frame
DoorSense
Flush Mount
Step 7. Calibrate your Lock
Follow the instructions in the app until you have successfully calibrated your lock and DoorSense.
21
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 22
Using Your Lock
Exterior Keypad
Wake or One Touch Locking
Warnings
Lock door
Mechanical Key Cylinder
Interior Lock
22
Battery Cover
Passage Button
Thumbturn
Indicator Light
To Unlock the Door
1. Press the Yale logo on the exterior keypad.
2. Enter the entry code.
3. Press the
.
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Yale Logo
Checkmark Button
Page 23
Features
Feature
Description
DoorSense
Entry Codes
Auto-Lock
Auto-Unlock
Passage Mode
• DoorSense tells you if your door is closed or open. Note: You can only ask a Voice Assistant if the door is locked or unlocked.
• Entry Codes are used to unlock your door.
• Create entry codes from the “Guest List” screen in our app.
• You can set the entry code to work permanently, recurring, or on a temporary schedule.
• An unlimited number of entry codes can be created or deleted at any time.
• Auto-Lock automatically locks your door for you.
• It can be set to lock on a timer, as short as 30 seconds, or as long as 30 minutes.
• When using the Auto-Lock feature with the DoorSense, your door will not lock until it is in the closed position.
• Auto-Lock can be set up in the lock settings of the app.
• Auto-Unlock knows when you arrive and unlocks the door as you approach.
• Auto-Unlock can be set up in the lock settings of the app.
• Use passage mode when you want to disable Auto-Lock for an extended period of time. Simply press the button on the inside of the lock to turn it on.
• To turn passage mode off, simply lock your door.
Integrations
• Yale Access products work in harmony with some of your favorite smart home brands to make life more simple and secure.
• Integrations can be set up in the Yale Access App from the “Works With” screen.
23
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 24
Setting Definitions
Setting
Default
Definition
Codes
Programming Code
Automatically
created by theYale
Access App
This code is used to access programming features: Handing, Smart Module integration, and Diagnostics. This code cannot be used to unlock the door. Find your programming code in the
Yale Access App, enter this code on the keypad and press the gear symbol.
Entry Codes
Entry codes can be created,from the Yale Access App, for users to allow them to lock/unlock the door from the lock keypad.
Security Settings
Hide Entry Codes Off If turned on, all entry codes within the app will be hidden from view.
VerifiedAccessOff If turned on, biometric/passcode authentication is required from the app to operate the lock.
Notifications
Smart Alerts OffCreate alerts you wish to receive from the app.
Automation
Auto-Lock
Off
Door will automatically lock, either when door is closed (with DoorSense), or based on a timer.
Auto-Unlock Door will automatically unlock when you arrive home.
DoorSense
Must be installed Allows you to know when your door is opened or closed.
Off
24
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 25
Setting Definitions
Setting
Default
Definition
Advanced Device Settings
Volume
Operating Mode:
Normal
Operating Mode:
Vacation
Inside Indicator Light
One Touch Locking
Passage Button
On
On
Off
Off
On
Off
This feature can be changed in theYaleAccess App.You can turn the lock volume on or off.
When the lock is in normal operating mode all entry codes will work and the lock can be unlocked/locked from the app and voice assistants.
This feature can be enabled in theYaleAccess App. When enabled all entry code access will be restricted. Users can still lock and unlock the door with the app.
This feature can be enabled in theYale accesspp. WhenAturned on, it will show the active status (locked) of the lock. This light will also inform you when the batteries are low, passage mode is enabled, and successful pairing.
Lock the keypad by touching the Yale logo.
The passage button can be used to temporarily turn off auto-lock, so you can easily come and go without needing to unlock your door each time. To turn on passage mode, press the passage button on the inside of the lock.To turn off passage mode, simply lock your door.
Keypad Security:
Shutdown Timing
60 seconds
Keypad Security:
Wrong Code Limit
5 times
After five unsuccessful attempts at entering avalid ntry ode, the lock will shut down and notec allow operation for sixty seconds. This timing can be changed from the app from 3 to 10.
The lock will shutdown for sixty seconds and not allow operation after the wrong code entry limit (3 attempts) has been made. This timing can be changed between 10 seconds to 3 minutes in the app.
25
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 26
Troubleshooting
Symptom
Lock does not respond ­door is open and accessible.
Lock does not respond ­door is locked and inaccessible.
Lock is on for a while then shows no reaction. Lights dim.
Lock chimes indicating code acceptance, but door will not open.
Lock operates to allow access, but will not automatically unlock.
Lock responds "Low Battery".
*When batteries are replaced, Smart Module locks have a real time clock that will be set through the User Interface.
It is recommended to verify correct date and time; particularly those locks operating under Daylight Savings Time.
Suggested Action
•Keypad becomes active when the Yale logo is pressed.
•Verify contact with the logo.
• If keypad numbers arevisible, check they respond when pressed.
• Check batteries are installed and oriented correctly (polarity) in battery case. Replace batteries* if dead.
• Check to ensure keypad wire is fully connected and not pinched.
• Batteries may not have enough power. Replace batteries*.
•Use mechanical key to unlock the door.
• Batteries do not have enough power. Replace batteries*.
• Check for any foreign objects between door and frame.
• Check that the wire is firmly connected to inside lock.
• Check to see if Auto-Lock is enabled.
•Disable Auto-Lock to lock the door (manually).
• This is the alert to replace the batteries. Replace all four (4) batteries* with newAAAlkaline batteries.
26
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 27
Troubleshooting
Symptom
Entry ode will not register.c
Upon entering an ntry ode andec pressing the check key, the lock displays “invalid code” error or lock times out without responding.
Upon entering an ntry ode andec pressing the check key, lock responds “Wrong number of digits”.
Deadbolt does not extend when locking the door with keypad.
Lock operates, but makes no sound.
*When batteries are replaced, Smart Module locks have a real time clock that will be set through the User Interface.
It is recommended to verify correct date and time; particularly those locks operating under Daylight Savings Time.
Suggested Actio n
• If low battery indicator is lit, change batteries*.
• Entry code must consist of 4 to 8 digits.
• The same ntry ode cannot be used for multiple users.ec
• Entry ode must be entered within 5 seconds (while keypad is active) or process willc have to be restarted.
•Verify entered code is avalid, previously programmed, 4 to 8 digit code.
•Vacation mode is on. Only an admin user can changevacation mode. Contact the admin.
• The digits entered were incorrect or incomplete. Re-enter the correct code followed by the check key.
• Lock was not handed properly. Rehand lock through Settings Menu.
• Check in the Yale Access App to see if Volume is set to off.
27
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 28
Hardware Troubleshooting
Symptom
Deadbolt grinds and will not extend to lock when using an ntry ode butec thumbturn locks and unlocks smoothly.
Deadbolt is hitting the strike plate.Reposition the strike plate to align with deadbolt.
Deadbolt is not fully extending. Increase depth of the deadbolt strike pocket in frame.
Resistance when locking deadbolt that requires pushing or pulling on the door to align deadbolt and latch.
Solution
Attempt re-handing using the Settings Menu. You must use Code to access the Settings Menu.Programming
Adjust your existing knob, lever or handleset strike plate. Latch engagement into the strike is the main component used for door alignment.
To adjust Knob/Lever/Handleset strike plate:
1. Remove plate from door frame with a hand screwdriver. (Using an electric driver may strip screw heads or enlarge screw holes.)
2. Locate tab on strike plate. Bend the tab towards surface of strike. Note: A small change may be all that is required.
3. Reinstall strike plate using a screwdriver and test again.
4. If door cannot be adjusted sufficiently with strike tab, both knob/lever/handleset latch and deadbolt could require adjustment –we suggest you contact a local locksmith for assistance.
For help with misalignments, watch our door alignment video: US.YaleHome.com/Support
28
Ta b
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 29
Resetting Lock to Factory Defaults
When lock is reset*, it will remove the lock from the Yale Access App and remove all pin codes and settings that
Reset Pin
Remove 1 battery to
reset lock.
Do not install Smart Module with batteries installed.
Interior Lock
were changed.
To Reset Lock:
1. Remove battery cover and one battery.
2. Press reset button for 1 minute with the reset tool provided in the hardware box.
3. Replace cover.
Note: If the lock was enrolled in a ZWave network prior to reset, it will need to be set up again.
*After reset, lock must be set up with the Yale Access App.
29
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 30
Keypad Alerts
Keypad Meaning
Gear flashes Amber Low Battery Level 1
Gear flashes Red Low Battery Level 2
Gear flashes Red then stays red until batteries are replaced
Checkmark flashes Pairing Success
X then gear flashes Red Jammed Lock
Gear flashes White Pairing/successful pairing
Gear flashes Red during pairing Failed Pair
30
Low Battery Level 3
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 31
Interior Lock Light Alerts
Light
Inside Lock Light Meaning
Blue flashing Low Battery Level 1
Blue flashing Low Battery Level 2
Blue flashing Low Battery Level 3
Pink flashing Passage Mode enabled
Red flashLocked state
Green flash Unlocked state
Green 3 second solid Pairing Success
Red 3 second solid Pairing Fail
31
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Page 32
Use:
Use of the Works with Apple badge means that an accessory has been designed to work specifically with the technology identified in the badge and has been certified by the developer to meet Apple performance standards.
Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards.
Apple®, Apple Home™, Apple Watch®, HomeKit®, and iPhone® are trademarks of Apple Inc., registered in the U.S. and other countries and regions.
Google, Google Play and Google Home are trademarks of Google LLC.
Amazon, Alexa and all related logos are trademarks of Amazon.com, Inc. or its affiliates.
Wi-Fi is a registered trademark of Wi-Fi Alliance®.
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by [licensee name] is under license. Other trademarks and trade names are those of their respective owners.
24/7 Support: 1-855-213-5841 • US.YaleHome.com
Yale® and Assure Lock® 2 are registered trademarks of Yale Home. Other products’ brand names may be trademarks or registered trademarks of their respective owners and are mentioned for reference purposes only. ©Copyright 2022. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Home is prohibited.
FCC:
FCC ID: 2ABFGYRD450BLEV1 IC ID: 11626AYRD450BLEV1 Class B Equipment This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Yale Home
32
Warning: Changes or modifications to this device, not expressly approved by Yale Home could void the user’s authority to operate the equipment.
Industry Canada:
FCC ID: 2ABFGYRD450BLEV1 IC ID: 11626AYRD450BLEV1 This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations.
Part of ASSA ABLOYP/N YRD400-KD-0022 Rev ATrusted every day
Loading...