![](/html/88/881c/881c41e4cca9459cc40e2deba9e4fe954f1c049486a1f1dd6d19a6641e2d2bff/bg1.png)
™
Yale Real Living
Touchscreen Deadbolt Quickstart Guide
For Technical Assistance call Yale:
1-800-810-WIRE (9473).
For more information go to: www.yalerealliving.com
1
(2) M4 x 25.4mm
[8-32 x 1"]
Flat Head
Combination Screws
2
(2) M4 x 25.4mm
[8-32 x 1"]
Flat Head
Combination Screws
Detail A
Inside Mounting Plate
Components
Quick Start Instructions
Installation Instructions
Door Marker
Outside Escutcheon
Inside Escutcheon Assembly:
• Inside Mounting Plate
• Inside Escutcheon
• Battery Cover
4 AA Alkaline Batteries
Bolt
Strike Plate
Screw Pack (7 screws)
2 Keys
Tools Needed
Phillips #2 screwdriver
2-1/8" (54mm) hole saw
1" (26mm) boring bit
7/64" (2.5mm) drill bit
Chisel & hammer
Outside Escutcheon
3
4
Inside Mounting Plate
(2) M6 x 59.5mm
[15/64 x 2-11/32"]
Pan Head Machine Screws
Cable
See Detail B
5
Inside Escutcheon
7
6
(3) M4 x 8mm
[8-32 x 5/16"]
Pan Head Screws
Battery Cover
9
8
10
Harness Clip
Detail B
Directions
1. Install bolt in door.
NOTE: The bolt must be in a retracted position
when installing the lockset.
Attach with two (2) M4 x 25.4mm screws
supplied.
2. Install strike on the door frame.
3. Route the cable through 2-1/8" diameter hole.
NOTE: Cable must go
under bolt and through.
See Detail A.
4. Insert outside escutcheon while routing cable
through inside mounting plate’s 1/2" hole; insert
mounting plate “tongue” into bottom slot of
outside escutcheon and tailpiece through bolt.
5. Secure inside mounting plate to outside
escutcheon using (2) M6 x 59.5mm pan head
machine screws. Do not over-tighten.
6. Attach cable connector to inside escutcheon
circuit board (See Detail B above). Press firmly
with thumbs so that back edge (wires) of
connector lines up with arrows on PCB.
An ASSA ABLOY Group brand
CAUTION:
Use care when assembling to ensure that cable
lies against the back recessed area of the inside
escutcheon.
Position and bend the cable, using the harness
clip as shown in Detail B to prevent binding
when installing the escutcheon over the mounting
plate.
7. Slide inside escutcheon over mounting plate.
8. Install and secure using (3) M4 x 8mm pan
head screws through the battery housing into
the mounting plate.
9. Insert four (4) AA alkaline batteries. The lock
responds, “Welcome to Yale Real Living.”
Note: Refer to programming instructions prior to
completion of step 10.
10. Install battery cover and tighten
screw with #2 Phillips screwdriver.
P/N AYRD220-INST-QUK Rev B
![](/html/88/881c/881c41e4cca9459cc40e2deba9e4fe954f1c049486a1f1dd6d19a6641e2d2bff/bg2.png)
Programming
Yale Real Living
™
Touchscreen Deadbolt Quickstart Guide
Open Door With PIN Code
1. Touch the screen with
the back of your hand
or fingers to activate.
1 2 3 4
M
1. Touch the screen with
the back of your hand
or fingers to activate
.
2. Enter the 4-8 digit Master
PIN code* followed by
the
key.
Lock Response: “Menu
mode, enter number, press
the
key to continue.”
3. Enter digit corresponding
to the function to be
performed followed by
the
key.
Follow the voice
commands.
4. Press the
key to
complete the process
and conclude the
programming session.
Note: If the lock is
connected to a controller,
it is recommended that it
be programmed through the
centralized user interface
(PC or hand-held device)
to ensure communication
between the lock and the
controller unit.
*Default Master Pin Code must be changed
prior to any programming of lock.
Master PIN Setting*
Register User PIN
Auto Relock
Volume
Language
All Code Lock-Out
HCP Module
Setting**
**This function appears only
with network module installed.
M
Register
Delete
Enable
Disable
High
Low
Silent
English
Spanish
French
Enable
Disable
Register
Delete
User Number (UN)
5
1~25 : without network module
1~250 : with network module
U
Continue
Complete
Continue
Complete
Features
• For proper security, the Master
PIN code* must be changed
prior to programming the lock.
• PIN codes can be 4 to 8
digits in length.
• The
accept an entry, and also to
conclude a programming
session.
• The
enter or to continue additional
steps in a programming
sequence.
For more information go to: www.yalerealliving.com
key is used to enter or
key is used either to
*The factory default Master
PIN code is: 1 2 3 4 5 6 7 8.
For Technical Assistance call Yale:
1-800-810-WIRE (9473).
2. Enter PIN code.
3. Touch the
key to confirm
the selection.
4. Unlock.
P/N AYRD220-INST-QUK Rev B
An ASSA ABLOY Group brand