Key-Free Keypad Deadbolt with Z-Wave Plus (YRD136)
Installation and Programming Instructions
Before you begin
DOWNLOAD
THE BILT APP
for step-by-step installation
instructions & to register
your product
FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO
#8-32 x 5/16"
Machine screws
OR
x2 Gold
M6x36mm
PPHMS
(1-3/8")
THE PRODUCT AND VOID THE FACTORY WARRANTY
(Standard 1-3/4" - 2")
x3
x2 Black
M6x44mm
PPHMS
x4
#7 wood & #8-32
machine x 20mm
Combination screws
OR
x2 Silver
M6x55mm
PPHMS
(2-1/4")
1
P/N YRD136-MNL-0008 Rev C
Page 2
Preparing Door and Keypad Escutcheon
!
Cup must be removed from
escutcheon if bore hole is
less than 2-1/8".
2-1/8" Application
2
P/N YRD136-MNL-0008 Rev C
<2-1/8" Application
Page 3
1
Installing Latch & Strike Plate
2-3/8" position
x4
3
2- /
8
2-3/4" position
3
2- /
4
Rotate
Bolt must be in retracted
(unlocked) position. UP
!
arrow must be facing
upwards.
2- /
default
O
optional
3
8
3
P/N YRD136-MNL-0008 Rev C
Page 4
2
Installing Keypad Escutcheon
!
If bore hole is less
than 2-1/8", remove
cup by gently
compressing two
tabs while pulling.
Outside of Door
!
Ensure cable is
routed under the
deadbolt.
4
P/N YRD136-MNL-0008 Rev C
Page 5
3
x2
Installing Interior Mounting Plate
!
Choose proper
bolt length
and color
using guide on
page 1.
5
P/N YRD136-MNL-0008 Rev C
Page 6
4
Attaching the Cable Assembly
!
Avoid interference
with movement of
lock by routing
cable as shown.
6
P/N YRD136-MNL-0008 Rev C
Page 7
5
x3
Installing Interior Escutcheon
!
Thumbturn
should be in
vertical
position.
7
P/N YRD136-MNL-0008 Rev C
Page 8
Testing Operation
!
Deadbolt should
extend and retract
smoothly. If not, go
back to step 2.
!
Bolt must be in
retracted
(unlocked)
position before
installing AA
batteries.
8
P/N YRD136-MNL-0008 Rev C
Page 9
Initial Programming
Press to wake lock
Press
Press
Enter a 4-8 digit Master PIN code
Press to complete
!
Lock will not operate
until gear is pressed
and Master PIN code
is set.
After entering the Master PIN
code, press any key to complete
handing.
9
P/N YRD136-MNL-0008 Rev C
Page 10
6
Installing Cover
Congratulations, you've installed the Yale Pro™ SL
Key-Free Keypad Deadbolt with Z-Wave Plus (YRD136)!
Continue with Programming Instructions to customize your product.
10
P/N YRD136-MNL-0008 Rev C
Page 11
Programming Instructions
Low Battery Warning
Flashes RED
All Code Lockout Mode
Rapidly beeps 5 times
Failsafe 9 Volt
Battery Connection
(Use Alkaline battery)
Master PIN Code must be created before any further programming.
Max User Codes = 250 in network
Warning: Changes or modifications to this device, not expressly approved by
ASSA ABLOY Residential Group could void the user's authority to operate the equipment.
11
P/N YRD136-MNL-0008 Rev C
Page 12
1
Changing Master PIN Code
Press
Enter Master PIN code
Press
Press
Press
Enter 4-8
digit Master
PIN Code.
Press
12
P/N YRD136-MNL-0008 Rev C
Page 13
2
Creating User PIN Codes
Master PIN code must be created first.
Max User Codes = 250 in network
Press
Enter Master PIN code
Press
Press
Press
Press
Press
Enter 4-8 digit PIN code
Press
13
P/N YRD136-MNL-0008 Rev C
Page 14
3
Unlocking Door with PIN Code
Press
Code Chart
PIN Code Management - Up to 250 Users (in network)
User Name
Enter PIN
Press
"Unlock"
Duplicate if necessary
PIN Code
14
P/N YRD136-MNL-0008 Rev C
Page 15
Resetting Lock to Factory Default
When lock is reset to factory defaults all
user codes (including the Master PIN
code*) are deleted and all programming
features are reset to original default
settings (see "Factory Default Settings").
1. Remove the battery cover.
2. Remove the batteries.
3. While pressing the reset button
(minimum of 3 seconds) reinstall
batteries. Release reset button.
4. Replace battery cover.
Upon reset, Master Code creation is the
only option available and must be
performed prior to any other
programming of the lock.
NOTE: After setting the Master Code,
press any key to complete handing of
the lock.
Enrolling Lock In Z-Wave Plus Network
Your network controller first needs to be in
enrollment or exclusion mode for the lock
to be enrolled or removed from network.
Once you put the controller in the
enrollment or exclusion mode, the lock
can be enrolled or removed in the Z-Wave
Plus Plus network by pressing the
button.
To enroll lock using the button option:
1. Remove the battery cover.
2. Press button and hold until unit beeps
two (2) times.
3. Release button and network joining
automatically begins.
4. Replace battery cover.
To remove lock using the button option:
1. Remove the battery cover.
2. Press button and hold until unit beeps
five (5) times.
3. Release button and network removal
automatically begins.
4. Replace battery cover.
Use this procedure only
when network primary
controller is missing or
otherwise inoperable.
15
P/N YRD136-MNL-0008 Rev C
Page 16
Definitions
All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user (except Master) PIN code
access. When attempting to enter a code while the unit is in Lockout, the lock rapidly beeps 5 times.
Audio Mode: Choosing Disable (3) in Audio mode shuts off the code confirmation tone play-back for use in quiet areas. Audio
mode is enabled or disabled through feature programming by the Master code.
Automatic Re-lock Time: After a successful code entry or manual unlock with the key, the lock will automatically re-lock after
each unlock in an effort to keep your home secure. This feature is optional, and can be turned off. In the ON mode, the lock will
automatically re-lock after thirty (30) seconds.
Low Battery: When battery power is low, the Low Battery Warning Indicator flashes RED. If battery power is completely lost, use
the 9Volt battery override. To use the 9V battery override apply 9V battery, in either direction, to terminals below the keypad for
backup power option. Wake up the lock and enter your pin code to unlock the door.
Master PIN Code: The Master PIN code is used for programming and for feature settings. It must be created prior to
programming the lock. The Master code will also operate (unlock/lock) the lock.
Network Setting: This setting is available through the wireless button on the interior escutcheon and allows the lock to connect
with a network controller.
One Touch Locking: When the latch is retracted, activating the keypad will extend the latch (during Automatic Re-lock duration or
when Automatic Re-lock is disabled).
Shutdown Time: The unit will shutdown (flashing keypad) for sixty (60) seconds and not allow operation after the wrong code
entry limit has been met.
Tamper Alert: Audible alarm sounds if attempting to forcibly remove outside lock from door.
User PIN Code: The User code operates the lock. Maximum number of user codes is 250 in network.
Wrong Code Entry Limit: After five (5) unsuccessful attempts at entering a valid PIN code, the unit will shut down and not allow
operation for sixty (60) seconds.
16
P/N YRD136-MNL-0008 Rev C
Page 17
Feature Programming Through Menu Mode
Using Master PIN code*
1. Wake the lock by pressing the key.
2. Enter the 4-8 digit Master PIN code followed by the
3. Enter digit corresponding to the function to be performed followed by the
key.
key.
Master PIN Code Setting
User PIN Code Registration
Advanced Lock Settings
Default settings
in bold.
Audio Mode
M
Register
Delete
Automatic Re-lock
One Touch Locking
Handing the Lock
Enable
U
U
Disable
30 sec
60 sec
2 min
3 min
Enable
Disable
Preforms automatic
handing of the lock
Continue
Complete
All Code Lockout Mode
Factory Settings
Settings
Master PIN Code
Automatic Re-lock
One Touch Locking
AudioEnabled
Automatic Re-lock Time
Wrong Code Entry Limit
Shutdown Time60 Seconds
*The Master PIN code must be registered prior to any other programming of the lock.
Disable
For quiet areas, select Disable (3)
in Audio Mode.
Enable
Disable
Factory Setting
Registration required*
Disabled
Enabled
30 Seconds
5 Times
17
P/N YRD136-MNL-0008 Rev C
Page 18
Programming Troubleshooting
Symptom
Suggested Action
Press each keypad key for response when pressed.
nd the
keypad flashes three times.
18
P/N YRD136-MNL-0008 Rev C
Page 19
Warning: Changes or modifications to this device, not expressly approved by
ASSA ABLOY Residential Group could void the user's authority to operate the equipment.
!
FCC:
Contain FCC ID: 2ABFG- YRIZW2USTS1
Model: YRD136-ZW-619,605,0BP
This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there
is no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful Interference to radio or television reception,
which can be determined by turning the equipment
off and on, the user is encouraged to try to correct
the interference by one or more of the following
measures:
Ÿ Reorient or relocate the receiving antenna.
Ÿ Increase the separation between the equipment
and receiver.
Ÿ Connect the equipment into an outlet on a circuit
different from that to which the receiver is
connected.
Ÿ Consult the dealer or an experienced radio/TV
technician for help.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC
RULES. OPERATION IS SUBJECT TO THE FOLLOWING
TWO CONDITIONS.
(1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT
ANY INTERFERENCE RECEIVED, INCLUDING
INTERFERENCE THAT MAY CAUSE UNDESIRED
OPERATION.
Industry Canada:
Contain 11626A- YRIZW2USTS1
Model: YRD136-ZW-619,605,0BP
Section 7.1.2 of RSS-GEN Under Industry Canada
regulations, this radio transmitter may only operate
using an antenna of a type and maximum (or lesser)
gain approved for the transmitter by Industry Canada.
To reduce potential radio interference to other users,
the antenna type and its gain should be so chosen
that the equivalent isotropically radiated power
(e.i.r.p.) is not more than that necessary for
successful communication.
En vertu des règlements d'Industrie Canada, cet
émetteur radio ne peut fonctionner avec une antenne
d'un type et un maximum (ou moins) approuvés pour
gagner de l'émetteur par Industrie Canada. Pour
réduire le risque d'interférence aux autres
utilisateurs, le type d'antenne et son gain doivent
être choisies de façon que la puissance isotrope
rayonnée équivalente (PIRE) ne dépasse pas ce qui
est nécessaire pour une communication réussie.
Section 7.1.3 of RSS-GEN This Device complies with
Industry Canada License-exempt RSS standard(s).
Operation is subject to the following two conditions:
1) this device may not cause interference, and 2) this
device must accept any interference, including
interference that may cause undesired operation of
the device.
Cet appareil est conforme avec Industrie Canada RSS
standard exemptes de licence(s). Son fonctionnement
est soumis aux deux conditions suivantes: 1) ce
dispositif ne peut causer des interférences, et 2) cet
appareil doit accepter toute interférence, y compris
les interférences qui peuvent causer un mauvais
fonctionnement du dispositif.
This radio transmitter 6982A-YRHCPZW0FM has
been approved by Industry Canada to operate with
the antenna types listed below with the maximum
permissible gain indicated. Antenna types not
included in this list, having a gain greater than the
maximum gain indicated for that type, are strictly
prohibited for use with this device.
Le présent émetteur radio 6982A-YRHCPZW0FM a
été approuvé par Industrie Canada pour fonctionner
avec les types d'antenne énumérés ci-dessous et
ayant un gain admissible maximal. Les types
d'antenne non inclus dans cette liste, et dont le gain
est supérieur au gain maximal indiqué, sont
strictement interdits pour l'exploitation de l'émetteur.
CAN ICES-3B/NMB-3B
19
P/N YRD136-MNL-0008 Rev C
Page 20
NOTE TO INSTALLER AND CONSUMER
While Yale has included several features to prevent lockout
®
(9-Volt battery jumper, low battery warnings), it is still possible
for a lockout situation to occur. Because this product does not
have a mechanical override (a key), Yale recommends to use
®
this product in an environment where there are additional
entry points into the dwelling.
Yale Home
Product Support Tel 1-855-213-5841 • www.yalehome.com
Yale® is a registered trademark of ASSA ABLOY Residential Group. Yale Pro™ is a trademark of ASSA ABLOY Residential Group.
Other products' brand names may be trademarks or registered trademarks of their respective owners and are mentioned for