Yale RH00529S, RH00538S Use, Care And Installation Manual

Page 1
RH00529S
RH00538S
Use, Care, and Installation Guide
DEC10.0101
READ AND SAVE THESE INSTRUCTIONS
Page 2
Page 3
SAFETY NOTICE ................................................................. 2-3
LIST OF MATERIALS ....................................................... 4
Ducting Calculation Sheet Mounting Height & Clearance Ducting Options Speci cations Electrical
........................................................... 7
............................................................... 8
......................................................................... 9
Installing the Power Pack
....................................... 5
................................ 6
........................................ 10
FEATURES & CONTROLS
Controls
......................................................................
11
MAINTENANCE
Cleaning and Installing Filters Lights
................................................................................ 13
............................... 12
TROUBLESHOOTING................................................................ 14
LIST OF PARTS AND ACCESSORIES
Electrical Diagrams
................................................................
.............................. 15
16
Table of Contents
1
Page 4
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE.
WARNING
TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. b. Before servicing or cleaning unit, switch power off at service panel and lock panel to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
CAUTION
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. Take care when using cleaning agents or detergents. Suitable for use in household cooking area.
WARNING
TO REDUCE THE RISK OF RANGE TOP GREASE FIRE:
a. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly
on low or medium settings. b. Always turn hood ON when cooking at high heat or when  aming food c. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or  lter. d. Use proper pan size. Always use cookware appropriate for the size of the surface element.
Important Safety Notice
e. Keep fan,  lters and grease laden surfaces clean. f. Use high setting on hood only when necessary. g. Don’t leave hood unattended when cooking.
h. Always use cookware and utensils appropriate for the type of and amount of food being prepared.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE, OBSERVE THE FOLLOWING:
a. SMOTHER FLAMES with a close- tting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS.
If the  ames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. b. NEVER PICK UP A FLAMING PAN – You may be burned. c. DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result. d. Use an extinguisher ONLY if:
1. You know you have a Class ABC extinguisher, and you already know how to operate it.
2. The  re is small and contained in the area where it started.
3. The  re department is being called.
4. You can  ght the  re with your back to an exit
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Installation work and electrical wiring must be done by quali ed person(s) in accordance with all applicable codes and standards.
Including  re-rated construction. b. Suf cient air is needed for power combustion and exhausting of gases through the  ue (chimney) of fuel burning equipment to prevent
back-drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National
Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and
the local code authorities. c. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. d. Ducted fans must always vent to the outdoors. e. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFI
(Ground Fault Interrupter protected branch circuit). g. NEVER place a switch where it can be reached from a tub or shower.
h. Make sure the power is off before installing, wiring or maintenancing.
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
CAUTION
To reduce risk of  re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages.
2
Page 5
OPERATION
Always leave safety grilles and  lters in place. Without these components, operating blowers could catch onto hair,  ngers and loose clothing.
The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to
negligence and the warranty of the unit automatically expires due to improper maintenance.
ELECTRICAL REQUIREMENTS
Important:
Observe all governing codes and ordinances. It is the customer’s responsibility:
- To contact a quali ed electrical installer.
- To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and all local codes and ordinances. If codes permit and a separate ground wire is used, it is recommended that a quali ed electrician determine that the ground path is adequate.
Do not ground to a gas pipe.
Check with a quali ed electrician if you are not sure the range hood is properly grounded.
Do not have a fuse in the neutral or ground circuit.
*National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269 ** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to
Electrical Diagram on product.
RH00529S - 720W, 6.1 Amps RH00538S - 790W, 6.7 Amps
A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase and install appropriate connector if necessary.
Important Safety Notice
3
Page 6
MODELS: RH00529S and RH00538S
PARTS SUPPLIED
kcaP rewoP - 1 2 - Decorative mesh  lters (RH00538S Qty 3) 2 - Halogen light bulbs (RH00538S Qty 4) 1 - Dual internal blower (pre installed)
retpada dnuor ”8 - 1
1 - Hardware package
List of Materials
HARDWARE PACKAGE CONTENTS
Suction Cup (1)
M4 x 1” (6)
M4 x 8 (4)
PARTS NOT SUPPLIED
- Ducting, conduit and all installation tools
- Cable connector (if required by local codes)
- Optional stainless steel hood liner
Wire Caps (3)
4
Page 7
Duct pieces
3-1/ 4” x 10” Rect., straight
Equivalent number length x used =
1 Ft. x ( ) =
To t a l
Ft.
Duct pieces
6” Round wall cap with damper
Equivalent number length x used =
30 Ft. x ( ) =
To t a l
Ft.
6” Round, straight
7”-10” Round,
straight
3-1/ 4” x 10”
0
Rect.90 elbow
3-1/ 4” x 10”
0
Rect.45 elbow
3-1/ 4” x 10”
0
Rect.90 flat elbow
3-1/ 4” x 10” Rect. wall cap with damper
3-1/ 4” x 10” Rect.to 6” round transition
3-1/ 4” x 10” Rect.to 6” round transition
0
elbow
90
6” Round,
0
90
elbow
1 Ft. x ( ) =
1 Ft. x ( ) =
15 Ft. x ( ) =
9 Ft. x ( ) =
24 Ft. x ( ) =
30 Ft. x ( ) =
5 Ft. x ( ) =
20 Ft. x ( ) =
15 Ft. x ( ) =
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
6” Round, roof cap
6” round to 3-1/ 4” x 10” rect. transition
6” round to 3-1/ 4” x 10” rect. transition
0
elbow
90
7” - 10”
Round,
0
elbow
90
7” - 10”
Round,
0
elbow
45
7” - 10”
Round
wall cap with damper
7” - 10” Round, roof cap
7” round to 3 1/ 4” x 10” rect. transition
7” round to 3-1/ 4” x 10” rect. transition
0
90
elbow
30 Ft. x ( ) =
1 Ft. x ( ) =
16 Ft. x ( ) =
15 Ft. x ( ) =
9 Ft. x ( ) =
30 Ft. x ( ) =
30 Ft. x ( ) =
8 Ft. x ( ) =
23 Ft. x ( ) =
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Installation – Ducting Calculation Sheet
Ft.
6” Round,
0
elbow
45
9 Ft. x ( ) =
Subtotal column1 =
Maximum Duct Length: For satisfactory air movement, the total duct length should not exceed 100 equivalent feet.
Ft.
Ft.
Subtotal column2 =
Subtotal column1 =
Total ductwork =
Ft.
Ft.
Ft.
5
Page 8
Minimum mount height between range top to hood bottom should be no less than 26”.
Maximum mount height should be no higher than 36”.
It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and  re hazard; while hoods mounted too high will be hard to reach and will lose its performance and ef ciency.
Min 26" - Max 36"
36"
If available, also refer range manufacturer’s height clearance requirements and recommended hood mounting height above range. Always check your local codes for any differences.
RH00529S & RH00538S
Vertical Ducting:
8” round minimum
Horizontal Ducting:
N/A
DUCTING
A minimum of 8” round must be used to maintain maximum air flow efficiency.
Always use rigid type metal ducts only. Flexible ducts could restrict air  ow by up to 50%.
Installation – Mounting Height & Clearance
Also use calculation (on page 5) to compute total available duct run when using elbows, transitions and caps.
ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required, increase duct size.
DAMAGE-SHIPMENT / INSTALLATION:
- Please fully inspect unit for damage before installation.
- If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or replacement.
- If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.
- If the unit is damaged by the installer (if other than the customer), repair or replacement must be made by arrangement between customer and installer.
If turns or transitions are required; install as far away from hood duct output and as far apart, between the two as possible.
6
Page 9
WARNING FIRE HAZARD
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside.
Use metal ductwork only.
Fasten all connections with sheet metal screws and tape all joints with certi ed Silver Tape or Duct Tape.
Some Ducting Options
side wall cap w/ gravity damper
Roof Pitch w/ Flashing & Cap
Soffit or crawl space
side wall cap w/ gravity damper
Installation – Ducting Options
7
Page 10
24
5/8
14 3/4
7
3/4
Installation – Speci cations
5”
4
3/8
7/16
3/4
11
2 3/8
25
15/16
29
13/16
4
7/16
11
C
L
RH00529S
front
C
L
elec.
k/o
1 1/2
RH00529S
top
11/16
1/2
6
14
13/16
15
1 5/16
11 7/16
13/16”
2 5/8
14 11/16” 15
13/16
RH00529S / RH00538S
side
*5”
7/16
11
3/8
2
33 1/8” 14
3/4
*7
3/4
34
5/8
38
7/16
RH00538S
front
C
L
C
2 5/8
A: elec.
k/o
L
A
4 1/2
13/16
14 11/16
15
7/16
11
4 3/4
1/2
6
RH00538S
top
8
Page 11
ELECTRICAL
WARNING
All Electrical work must be performed by quali ed electrician or person with similar technical know how and background.
For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance.
Follow national electrical codes or prevailing local codes and ordinances.
Electrical Supply:
This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire w/ ground. Please also refer Electrical Diagram labeled on product.
Cable Lock:
A cable locking connector (not supplied) might also be required by local codes. Check with local requirements and codes, purchase and install appropriate connector if necessary.
Cable Lock
Installation – Electrical
9
Page 12
!
F
w
D
k
3
e
elec
CAUTION: At least two installers are required due to the weight and size of the hood.
1. Remove support screw from top of Power Pack
before installing into cabinet. FIG 2b
2. Install 8” round adapter to top of Power Pack using (4) M4 x 8 screws.
3/4
14
RH00529S RH00538S
1/16” - 34 11/16
26
C/L
C/L
3. Install optional Stainless Steel Liner. Review manual
included with liner for more details.
4. If no liner is used, cut out an opening in the bottom of the cabinet by
following the dimensions in FIG 1.
5. Lift Power Pack into opening and secure to bottom of cabinet using (4) M4 stainless steel screws, (1) in each corner; see FIG 2. note: Wood blocking may need to be added to cabinet base if additional support is needed.
6. Install duct work and seal with duct tape.
7. Install electrical.
8.
Remove all packing materials before using Power Pack.
Switch power on and check for leaks around duct tape.
9. Install decorative mesh filters.
Installation – Installing the Power Pack
minimum
minimum
/4” wood bas
3/4” wood base
metal or other non combustible material
cabinet bottom cut-out size
FIG 1
Ductwork
uctwor
elec.
.
Front View
ront Vie
(4) M4 ss wood screws
(1) in each corner
FIG 2
remove support screw
FIG 2b
10
Page 13
1
Blower On/Off Speed Selection
2
Lights Off/Bright/Dim
0 I II III
1
BLOWER ON/OFF/SPEED SELECTION
0 is off, I is low speed, II is medium speed and III is high speed.
2
LIGHTS OFF/BRIGHT/DIM
0 is off, I is bright, and II is dim.
0 I II
Features & Controls – Mechanical Slide Switch
11
Page 14
SURFACE MAINTENANCE:
Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/ scoring pads which will scratch and damage surface. Do not use products containing chlorine bleach or orange cleaners.
For heavier soil use liquid degreaser.
After cleaning, you may use non-abrasive stainless steel polish/ cleaners, to polish and buff out the stainless luster and grain. Always scrub lightly using a micro ber or clean cotton cloth and with the grain.
Decorative Mesh Filters
The lters are intended to trap residue and grease from cooking. Although the  lters should never need replacing, they are required to be cleaned every 30 days or more often depending on cooking habits.
Filters may be placed in dishwasher at low heat or soaked in hot soapy water Dry  lters and re-install before using hood.
Installing Decorative Mesh Filters, FIG 4:
1. Place back of  lter into channel on back of power pack.
2. Pull down on  lter handle and pivot up until  lter is  ush
with bottom of power pack and locks into place.
Replacing Decorative Mesh Filters:
Hood Model: Part No. Qty. to Order
RH00529S 50200037 2
RH00538S 50200037 3
Maintenance – Cleaning and Installing Filters
1
2
FIG 4
12
Page 15
REPLACING LIGHT BULBS
CAUTION: Light bulb becomes extremely hot when turned on.
DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns.
Make sure all power is turned off and bulbs are not hot.
Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out.
If bulbs are dif cult to turn due to prolonged use,  rmly attach a glass suction cup approximately the diameter of the bulb or use a rubber/latex glove and turn counter clockwise.
Replacement bulbs are available at specialty lighting stores. Purchase type MR16 (GU-10) 35W halogen.
Maintenance – Lights
Bottom View
13
Page 16
TROUBLESHOOTING PROCEDURES FOR RH00529S AND RH00538S
od ot tahWesuaCeussI
After installation, the unit doesn’t work.
Troubleshooting
Light works, but motor is not turning.
The unit is vibrating.
The motor is working, but the lights are not.
The hood is not venting out properly.
Metal  lter is vibrating.
1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON.
2. The power line and the cable locking connector
is not connecting properly.
3. The switch wirings are disconnected. 3. Make sure the wirings at the switch
4. The wires on switch are loose . 4. Make sure the wires on the switch are
5. The switch is defective. 5. Change the switch.
1. The motor is defective, possible seized. 1. Change the motor.
2. The thermally protected system detects if the
motor is too hot to operate and shuts the motor down.
4. The motor wire is not connected. 4. Make sure the motor wire is plugged into the
1. The motor is not secure in place. 1. Tighten the motor in place.
olb degamaD .2
3. The hood is not secured in place. 3. Check the installation of the hood.
l si blub thgil ehT .2
3. The wires on the control board are loose. 3. Make sure the wires on control board are
1. The hood might be hanging too high from the
cook top.
2. The wind from the opened windows or opened
doors in the surrounding area are affecting the ventilation of the hood.
3. Blockage in the duct opening or duct work. 3. Remove all the blocking from the duct work or
4. The direction of duct opening is against the wind. 4. Adjust the duct opening direction.
5. Using the wrong size of ducting. 5. Change the ducting to correct size.
1. Metal  latem eht eg
2. Spring clip is broken. 2. Change the spring clip.
2. Check the power connection with the unit is connected properly.
are connected properly.
connected properly.
2. The motor will function properly after the thermally protected system cool down.
molex connector.
connected properly.
1. Adjust the distance between the cook top and the bottom of the hood within 26” and 36” range.
2. Close all the windows and doors to eliminate the outside wind  ow.
duct opening.
nahC .1.esool si retl  lter.
.roticapac eht egnahC .3.roticapac degamaD .3
.rewolb eht egnahC .2.leehw rew
.blub negolah eht egnahC .1.blub negolah evitcefeD .1
.blub thgil eht nethgiT .2.esoo
14
Page 17
DESCRIPTION PART #
Replacement Parts
Light Bulb MR16 (GU10) 35W (each) Z0B-0023 Decorative Mesh Filter (each) 50200037
Optional Accessories
Liner,36” (RH00529S) AK0806AS Liner,42” (RH00529S) AK0842AS Liner,48” (RH00538S) AK0848AS Liner,54” (RH00538S) AK0854AS Liner,60” (RH00538S) AK0860AS
To order parts please call 1.888.750.1698