Yale AYRD110 Installation And Programming Instructions

®
Key Free Push Button Deadbolt B1L
Yale Real Living
®
Installation and Programming Instructions
Before you begin
DOWNLOAD
THE BILT APP
for step-by-step installation
instructions & to register
your product
FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO
x4
#7 wood & #8-32 machine x 20mm
Combination screws
THE PRODUCT AND VOID THE FACTORY WARRANTY
x3
Machine screws
x2
M6x47mm
Long through bolt
1
P/N -110- - - Rev DAYRD STANDALONE INST FUL
Preparing Door
2
P/N -110- - - Rev DAYRD STANDALONE INST FUL
1
x4
Installing Latch & Strike Plate
2-3/8" position
d faute
2-3/4" position
O
optional
Press
Bolt must be in retracted (unlocked) position. Note
horizontal orientation of
mechanism.
Pull
3
P/N -110- - - Rev DAYRD STANDALONE INST FUL
2
Installing Keypad Escutcheon
Outside of DoorInside of Door
Bolt must be in retracted (unlocked) position. Note horizontal orientation
of mechanism.
4
P/N -110- - - Rev DAYRD STANDALONE INST FUL
3
x2
Installing Interior Mounting Plate
Loosen screw to remove cover.
5
P/N -110- - - Rev DAYRD STANDALONE INST FUL
4
Attaching the Cable Assembly
6
P/N -110- - - Rev DAYRD STANDALONE INST FUL
5
x3
Installing Interior Escutcheon
7
P/N -110- - - Rev DAYRD STANDALONE INST FUL
Testing Operation
!
Bolt must be in retracted
(unlocked) position before
installing batteries.AA
8
P/N -110- - - Rev DAYRD STANDALONE INST FUL
Handing the Lock
Press . Press . Press . Enter
new Master code (4-8 digits).PIN
Press to complete.
After entering the Master code,PIN press any key to complete handing.
9
P/N -110- - - Rev DAYRD STANDALONE INST FUL
6
Installing Cover
Congratulations, you've installed the Yale Real Living
Key Free Push Button Deadbolt B1L! Turn sheet over for
Programming Instructions to customize your product.
®
10
P/N -110- - - Rev DAYRD STANDALONE INST FUL
Programming Instructions
Low Battery Warning- Flashes RED
Lock-out Mode- Keypad Flashes
Master Code must be created before any further programming.PIN Max User Codes = 25
!
Warning: Changes or modifications to this device, not expressly approved by Yale Security Inc. could void the user's authority to operate the equipment.
Failsafe 9 volt Battery Connection (Use Alkaline battery)
11
P/N -110- - - Rev DAYRD STANDALONE INST FUL
1
Creating Master CodePIN
Press
Press
Press
Enter 4-8 digit Master
Code.PIN
Press
12
P/N -110- - - Rev DAYRD STANDALONE INST FUL
2
Creating User CodesPIN
Master code must be created first.PIN *Max User Codes = 25
Enter Master codePIN
Press
Press
Press
Press
Press
Enter 4-8 digit codePIN
Press
13
P/N -110- - - Rev DAYRD STANDALONE INST FUL
3
Unlocking Door with CodePIN
Enter PIN
Press
"Unlock"
Code Chart
User Type
Master
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
Duplicate if necessary
PIN Code Management (Up to 25 Users)
User Name User #
PIN Code
User ___
User ___
User ___
User ___
User ___
User ___
14
P/N -110- - - Rev DAYRD STANDALONE INST FUL
Resetting Lock to Factory Default
When lock is reset to factory defaults all user codes (including the Master code*) arePIN deleted and all programming features are reset to original default settings (see "Factory Default Settings").
1. Remove the battery cover.
2. Remove the batteries.
3. While pressing the reset button (minimum of 3 seconds) reinstall batteries. Release reset button.
4. Replace battery cover.
Upon reset, Master Code creation is the only option available and must be performed prior to any other programming of the lock. NOTE: After setting the Master Code, press any key to complete handing of the lock.
15
P/N -110- - - Rev DAYRD STANDALONE INST FUL
Definitions
All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user (except Master) code access. When attempting to enter a code while the unit is in Lockout, the keypad flashes 8PIN times and the lock beeps 3 times as well.
Audio Mode: Disable (3)Choosing in Audio mode shuts off the code confirmation tone play-back for use in quiet areas. Audio mode is enabled or disabled through feature programming by the Master code.
Automatic Re-lock Time: After a successful unlock, the unit will automatically re-lock after thirty (30) seconds.
Low Battery: When battery power is low, the Status Indicator flashes . If battery power is completely lost,RED
use the 9Volt battery override. To use the 9V battery override apply 9V battery, in either direction, to terminals below the keypad for backup power option. Wake up the lock and enter your pin code to unlock the door.
Master Code: It must be createdPIN The Master code is used for programming and for feature settings.PIN prior to programming the lock. The Master code will also operate (unlock/lock) the lock.
One Touch Locking: When the latch is retracted, activating the keypad will extend the latch (during Automatic Re-
lock duration or when Automatic Re-lock is disabled).
Shutdown Time: The unit will shut down (flashing keypad) for sixty (60) seconds and not allow operation after the wrong code entry limit has been met.
Tamper Alert: Audible alarm sounds if attempting to forcibly remove outside lock from door.
User Code:PIN The User code operates the lock. Maximum number of user codes is 25.
Wrong Code Entry Limit: After five (5) unsuccessful attempts at entering a valid code, the unit will shutPIN
down and not allow operation.
16
P/N -110- - - Rev DAYRD STANDALONE INST FUL
Feature Programming Through Menu Mode Using Master code*PIN
1. Enter the 4-8 digit Master PIN code followed by the
2. Enter digit corresponding to the function to be performed followed by the key.
*The Master code must be registered prior to any other programmingPIN
of the lock.
12
M
Master Code SettingPIN
User Code RegistrationPIN
Advanced Lock Settings
Default settings in bold.
Audio Mode
Enable
M
Register
Delete
Automatic Re-lock
One Touch Locking
Handing the Lock
key.
User Number ( ) 1~25 MaxPIN 4~8 Digits
U
U
Enable
Disable
Enable
Disable
Performs automatic handing of the lock.
N/A
All Code Lockout Mode
Factory Settings
Settings
Master CodePIN
Automatic Re-lock
One Touch Locking
Audio Enabled
Automatic Re-lock Time Wrong Code Entry Limit
Shutdown Time 60 Seconds
Disable
Factory Setting
Registration
For quiet areas, select Disable (3) in Audio Mode.
Enable
Disable
required*
Disabled
Enabled
30 Seconds
5 Times
*The Master code must be registered prior to any other programming of the lock.PIN
17
P/N -110- - - Rev DAYRD STANDALONE INST FUL
Programming Troubleshooting
Symptom
Lock does not respond – door is open and accessible.
Lock does not respond – door is locked and inaccessible.
Unit chimes to indicate code acceptance, but the door will not open.
Unit operates to allow access, but will not automatically re-lock.
PIN codes will not register.
Suggested Action
Press each keypad button for response when pressed.
• Check batteries are installed and oriented correctly (polarity)
• in the battery case.
Check batteries are in good condition; replace batteries
• if discharged. Check to see if cable is fully connected and not pinched.
Batteries may be completely discharged.
• Apply 9V battery to terminals below the keypad for backup
• power option.
Check to see if there is another locking device on the door.
• Check the door gaps for any foreign objects between door
• and frame. Check that the cable is firmly connected to the board.PC
Check to see if Auto Re-lock Mode is enabled.
• If low battery indicator is lit (see below), change batteries.
PIN codes must consist of 4 to 8 digits to register.
• The same code cannot be used for multiple users.PIN
• Registration/management of codes is set by thePIN
• authority of the Master Code.
Contact the Master user.
• User codes must be entered within 5 seconds or the
• process will have to be restarted.
Check mark
code.PIN
or gear cannot be used as part of the
Upon entering a codePIN and pressing the (*) key, the lock gives a series of beeps, flashes red & blue s 7LED times, and does not unlock.
Upon entering a codePIN and pressing the (*) key, there are different tones.
The unit operates, but it makes no sound.
The unit displays inter­mittent flashes.RED
Upon entering a codePIN and pressing the (*) key, the unit responds with a series of beeps and the keypad flashes three times.
• All Code Lockout Mode is enabled.
• Only the Master can enable/disable All Code Lockout Mode.
• Contact the Master user.
• Check to see if the lock is set to All Code Lockout Mode.
• Setting/managing All Code Lockout Mode is done through Master Code only. Contact the Master user.
Enable Audio Mode.
• This is the Low Battery indicator alerting that it is time to replace the batteries. Replace all four (4) batteries with new Alkaline batteries.AA
The digits entered were incorrect or incomplete. Re-enter the correct code followed by the check mark (*) key.
18
P/N -110- - - Rev DAYRD STANDALONE INST FUL
FCC:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the Rules. These limits are designed to provide reasonable protection against harmfulFCC interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful Interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/ technician for help.TV
Industry Canada:
This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.
19
P/N -110- - - Rev DAYRD STANDALONE INST FUL
NOTE TO INSTALLER AND CONSUMER While Yale has included several features to prevent lockout (9-
®
Volt battery jumper, low battery warnings), it is still possible for a lockout situation to occur. Because this product does not have a mechanical override (a key), Yale recommends to use
®
this product in an environment where there are additional entry points into the dwelling.
Product Support Tel 800.810.WIRE (9473) • www.yalelocks.com
Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company.
Yale® and Yale Real Living® are registered trademarks of Yale Security Inc.,
Copyright © 2017, Yale Security Inc., an Group company.ASSA ABLOY
All rights reserved. Reproduction in whole or in part without the express written permission
YALE, with its unique global reach and range of products, is the world's favorite lock
– the preferred solution for securing your home, family and personal belongings.
ASSA ABLOY is the global leader in door opening solutions,
dedicated to satisfying end-user needs for security, safety and convenience.
an Group company.ASSA ABLOY
of Yale Security Inc. is prohibited.
20
P/N -110- - - Rev DAYRD STANDALONE INST FUL
Loading...