YAESU FP-29
Visit http://www.fotango.org
AC POWER SUPPLY
for the FT-1000MP MARK-V HF Transceiver
The FP-29 is an external AC power supply for use with the FT-1000MP MARK-V HF Transceiver, providing 30
Volts DC at up to 15 amperes for extended periods.
Excellent regulation and conservative design assure the owner of many years of trouble-free operation. A thermally-switched cooling fan automatically activates during long periods of high current demand, to maintain a
safe operating temperature in the power supply.
Specifications
DC Output Voltage: +30 V , +13.8 V
DC Output Current: +30 V: 15A; +13.8 V: 3A
Input Voltage: AC 100-120V, 50 - 60 Hz
AC 200-240 V, 50 - 60 Hz
Current Consumption (Approx.): AC 100-120 V: 9 A, AC 200-240 V: 5 A
Operating Temperature Range: –10 °C ~ +50 °C
Case Size (W x H x D
Weight (Approx.): 3.2 kg (7 lbs)
Specifications are subject to change without notice or obligation.
):
106 x 135.5 x 331 mm
(4.2 x 5.3 x 13 inch)
Supplied Accessory
DC Power Cable: T9022299 (length: 2 meters) ............................................................................................1
AC Power Cable..........................................................................................................................................1
Operating Manual (this sheet) .....................................................................................................................1
Warranty Card ............................................................................................................................................1
YAESU MUSEN CO., LTD.
4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan
YAESU U.S.A.
17210 Edwards Rd., Cerritos, CA 90703, U.S.A.
YAESU EUROPE B.V.
P.O. Box 75525 1118 ZN, Schiphol, The Netherlands
YAESU UK LTD.
Unit 12, Sun Valley Business Park, Winnall Close
Winchester, Hampshire, SO23 0LB, U.K.
YAESU GERMANY GmbH
Am Kronberger Hang 2, D-65824 Schwalbach, Germany
YAESU HK LTD.
11th Floor Tsim Sha Tsui Centre, 66 Mody Rd.,
Tsim Sha Tsui East, Kowloon, Hong Kong
E A A 9 7 X 1 0 0

INSTALLATION
Before connecting the FP-29 to any power source, be absolutely certain that the voltage specification on the rear
panel matches your local supply voltage. The FP-29 is manufactured for use around the world, from a variety of
power sources, and the wiring must be connected properly to prevent damage to the internal circuit.
Connect the supplied AC Power Cable between the FP-29 AC jack and AC line outlet, then connect the supplied
DC Power Cable between the FP-29 OUTPUT jack and FT-1000MP MARK-V DC IN jack.
Warning: Our Warranty does not cover damage caused by improper supply voltage nor use of an improper fuse.
Operation
r Turn on the FP-29 MAIN switch on the front panel to activate the power supply. Always turn the FP-29 MAIN
switch on before turning on the FT-1000MP MARK-V POWER switch.
r To turn off the FP-29, always turn the FT-1000MP MARK-V POWER switch off before turning off the FP-29
MAIN switch.
Changing AC Mains Jumper Wiring
r Before change the AC Main Jumper, disconnect the AC Power Cable from the AC line outlet, then wait
10 minute for discharge the capacitor to prevent the electorical shock.
r Remove the 10 screws (right side: 6 screws; left side: 4 screws) affixing the top cover of the FP-29,
and remove the top cover.
r Perform the correct wiring on the Switching Regulator Unit
for the AC Mains voltage used in your area (AC 100-120 V
or AC 200-240 V) as shown below. There are three screw
terminals involved, and a jumper must be connected across
two of them, per the drawing at the right.
r Change the fuse in the fuse holder on the rear panel, as
indicated below. Do not use slow-blow type fuses.
AC Mains Voltage AC Fuse Rating
100 ~ 120 V 10 A
200 ~ 240 V 6 A
Also, change the voltage marking on the label on the rear
panel to match the new voltage setting.
r Replace the top cover and its 10 screws. This completes the wiring change.
Warning: Our Warranty does not cover damage caused by improper supply voltage nor use of an