Xylem 703 User Manual

MANUAL FOR PUMP C0NTROLLER 703MANUAL FOR PUMP C0NTROLLER 703
MANUAL FOR PUMP C0NTROLLER 703
MANUAL FOR PUMP C0NTROLLER 703MANUAL FOR PUMP C0NTROLLER 703
Contents:Contents:
Contents:
Contents:Contents:
General information 3
Ultrasonic measuring system 3
Hydrostatic measuring system 3
Amplifier 703 4
Electrical connection 5
Dimensions 6
Specifications 6
Maintenance 6
Orderingnumbers 6
Ultrasonic sensor 7005 7
Pressure transmitter 7050/7060 8
M703GB/9607
Page 1
CE – CERTIFICATE OF CONFORMITY
This product complies with the requirements concerning electromagnetic compatibility (EMC) stipulated in Council directive no. 89/336/EEC of 3rd May 1989, altered at directive no. 92/31/EEC, on the approximation of the laws of the Member States relating to electromagnetic compatibility.
MJK Automation A/S declare that the product complies to the values stipulated in EN 50081-1 and EN 50082-1.
Page 2
General InformationGeneral Information
General Information
General InformationGeneral Information
The MJK 703 Pump Controller is a compact unit designed for the control of liquid levels in 2-3 pumps or valves between four variable level settings. The Pump Controller has 3-digit continuous display of level measurements.
Ultrasonic MeasuringUltrasonic Measuring
Ultrasonic Measuring
Ultrasonic MeasuringUltrasonic Measuring
HydrHydr
Hydr
HydrHydr SystemSystem
System
SystemSystem
If hydrostatic measuring system is applied (703P), the pump controller is delivered with a pressure transmitter for either absolute or relative pressure. At absolute pressure transmitter type 7050 measures the hydrostatic pressure in the liquid (at the bottom). The amplifier has a build-in pressure compensation.
ostatic Measuringostatic Measuring
ostatic Measuring
ostatic Measuringostatic Measuring
SystemSystem
System
SystemSystem
The ultrasonic sensor has a moulded-in piezoelectric crystal which emits an ultrasonic signal and receives an echo signal from the surface measured. The amplifier converts the signals received from the sensor to a level­proportional signal which is used for display of level values and for maximum and minimum level monitoring within the six limit settings.
At relative pressure transmitter type 7060 is used, this transmitter has a tube for pressure equalizing. The measured bottom pressure is equalized with the surface pressure via the tube, and the transmitter directly measures the correct liquid pressure. The 4-20 mA signal from the transmitter is sent to the amplifier, where the level is indicated and the start / stop / alarm signals are processed.
When measuring in pressure tanks, the maximal pressure (super-pressure + liquid pressure) must not exceed the range of the connected transmitter.
Page 3
Amplifier 703Amplifier 703
Amplifier 703
Amplifier 703Amplifier 703
OperationOperation
Operation
OperationOperation
The Pump Controller is operated by means of a display selector which can be set to a number of positions for the reading of level values during operation, as well as for resetting. The Controller is designed for continuous operation - also during calibration - so the selector cannot be „forgotten“ in a calibrating position thereby disturbing or spoiling the control action.
Start and stop levelsStart and stop levels
Start and stop levels
Start and stop levelsStart and stop levels
Set the start, stop and alarm levels by turning the selector switch to the desired position, and adjust the relevant potentiometer. Note: To obtain the best accuracy when adjusting, the potentiometer settings are relative to the chosen 0-level (for ultrasonic measurig systems) or range (for hydrostatic measuring systems) If the 0-level/range is set for e.g. 3 m, the range for start/ stop and alarms will be limited to 0 - 2.25 m (ultrasonic) or 0 - 3 m (hydrostatic). The amplifier has logic for both filling and emptying. When the starting levels are set lower than the stopping levels, the pumping action will be filling. When the starting levels are set higher than the stopping levels, it will be emptying. This logic prevents dry pumping in the event of failure.
the alarm indicator for ERROR will be lit. When an error is detected, the pump controller will prevent the pumps from running. The detected error can be set to activate one of the output relays, see futher in section "Selection of output signals".
Exceeding the measuring rangeExceeding the measuring range
Exceeding the measuring range
Exceeding the measuring rangeExceeding the measuring range
If the measurement exceeds the measuring range, the amplifier will indicate that the measuring range has been exceeded by showing three lit-up points in the display e.g.: „0.5.6.“
Selection of output signalsSelection of output signals
Selection of output signals
Selection of output signalsSelection of output signals
A three-pole switch for coding of the output signals and three potentiometers for time delay adjustment are located on the back of the top circuit board.
Switch positions:Switch positions:
Switch positions:
Switch positions:Switch positions:
AlternatingAlternating
Alternating
AlternatingAlternating
The alternation selector is set to „NORMAL“ or „ALTERNA­TING“ as desired. In the „NORMAL“ position the „level 1“ settings will control pump no. 1 and the „level 2“ settings will control pump no.
2. In the „ALTERNATING“ position „level 1“ will control pump no. 1 and pump no. 2 alternately, and „level 2“ will act in reverse.
Alarm levelsAlarm levels
Alarm levels
Alarm levelsAlarm levels
The setpoints for high and low alarm are adjusted as follows: Turn the display selector to „level 3 high“ or „level 4 low“ as required, and turn the relevant potentiometer until the desired level is displayed. For low alarm, the alarm starts at the setpoint and disconnects approx. 1% above the setpoint. Similarly, the high alarm begins at the setpoint, and ceases approx. 1% belove it. The two alarm relays are active for normal levels, and idle during alarm. The relays may instead be connected to the echo failure circuit by means of the changeover switches mentioned in section "Setting of output signals".
Adjustment of current outputAdjustment of current output
Adjustment of current output
Adjustment of current outputAdjustment of current output
Set the changeover switch located on the underside of the top circuit to 0-20 or 4-20 mA (standard setting at delivery 4-20 mA). Set the selector switch to „mA OUTPUT“. Then, by means of the mA OUTPUT SPAN potentiometer, set the output current in per cent of 0-20/4-20 mA corresponding to the value measured at the time.
1: mA output 4 - 20 mA 0 - 20 mA 2: Relay 4 Low level alarm Echo failure alarm 3: Relay 3 High level alarm Echo failure alarm
The three potentiometers have the following functions:The three potentiometers have the following functions:
The three potentiometers have the following functions:
The three potentiometers have the following functions:The three potentiometers have the following functions:
TIME DELAY RELAY 2:
In order to prevent simultaneous activation of two large motors, Relay 2 may be set to delayed triggering. Delays between 0 and 20 secs may be set.
TIME DELAY RELAY 3:
The Relay 3 alarm, whether usedas high alarm or echo failure alarm may be delayed 0.1 - 5 mins.
TIME DELAY RELAY 4:
The Relay 4 alarm, whether usedas low alarm or echo failure alarm may be delayed 0.1 - 5 mins.
MountingMounting
Mounting
MountingMounting
The amplifier can be mounted directly on a wall. For panel mounting a mounting kit can be ordered. For outdor mounting a local mounting kit with rain roof can be ordered.
ERROR alarmERROR alarm
ERROR alarm
ERROR alarmERROR alarm
If the transmitter is wrongly connected, or if the wire is cut,
Page 4
Electrical ConnectionElectrical Connection
Electrical Connection
Electrical ConnectionElectrical Connection
703U Ultrasonic Pump Controller 703U Ultrasonic Pump Controller
703U Ultrasonic Pump Controller
703U Ultrasonic Pump Controller 703U Ultrasonic Pump Controller
Supply
Ultrasonic sensor
703P Pressure Pump Controller 703P Pressure Pump Controller
703P Pressure Pump Controller
703P Pressure Pump Controller 703P Pressure Pump Controller
Supply
Pressure transmitter
ExamplesExamples
Examples
ExamplesExamples
Installation with 2 pumps, high and low alarmInstallation with 2 pumps, high and low alarm
Installation with 2 pumps, high and low alarm
Installation with 2 pumps, high and low alarmInstallation with 2 pumps, high and low alarm
Control­output 1 pump/ valve
Control­output 1 pump/ valve
Control­output 2 pump/ valve
Control­output 2 pump/ valve
Alarm high level
Alarm high level
Alarm low level
Alarm low level
mA-output 0-20/4-20mA
mA-output 0-20/4-20mA
Installation with 3 pumps (2 operational and 1 stand-by)Installation with 3 pumps (2 operational and 1 stand-by)
Installation with 3 pumps (2 operational and 1 stand-by)
Installation with 3 pumps (2 operational and 1 stand-by)Installation with 3 pumps (2 operational and 1 stand-by)
Page 5
DimensionsDimensions
Dimensions
DimensionsDimensions
SpecificationsSpecifications
Specifications
SpecificationsSpecifications
Amplifier 703Amplifier 703
Amplifier 703
Amplifier 703Amplifier 703 Measuring range: Determined by sensor Voltage: 220 - 240 / 110 - 120 / 24V AC Consumption: Approx. 10 VA Temperature: –20 - +60 Input signal: From ultrasonic sensor,
pressure transmitter or
4-20 mA Accuracy: ±1% Outputs:
Analog: 0 - 20/4 - 20 mA max. 500W Digital: 4 relays with voltage free
change-over contact Inductive load: 250V, 4A ohmic, max. 100V A. Indication: 3-digit LED display Operation: From front panel Dimensions: 185 x 240 x 115 mm (HxWxD) Materials: Polystyrol with clear cover CE: EN50081-1, EN50082-1 Housing: IP 65
O
C.
MaintenanceMaintenance
Maintenance
MaintenanceMaintenance
The amplifier and the ultrasonic sensor does not demand any particular maintenance. When cleaning the presure transmitter, care must be taken not to damage the membrane.
Ordering Details:Ordering Details:
Ordering Details:
Ordering Details:Ordering Details:
Part no.: Specification:Part no.: Specification:
Part no.: Specification:
Part no.: Specification:Part no.: Specification: 201020 703U-1111 Ultras. Pump Control. 0-10 m, with 7005-1013 202004 703P-1103 Pump Controller without transm., input 4-20mA
(only absolute pressure) 202010 703P-1104 Pump Controller without transm., input 4-20mA 202017 703P-1114 Pump Controller with 7060-1413, range 0-3 m 202019 703P-1124 Pump Controller with 7060-1423, range 0-10 m 202021 703P-1134 Pump Controller with 7060-1433, range 0-30 m 202015 703P-1113 Pump Controller with 7050-1413, range 0-10 m
(Absolute pressure transmitter with compensation) Accessories for AmplifierAccessories for Amplifier
Accessories for Amplifier
Accessories for AmplifierAccessories for Amplifier 200105 Panel mounting kit 200115 Local mounting kit with rain roof Accessories for Sensor 7005Accessories for Sensor 7005
Accessories for Sensor 7005
Accessories for Sensor 7005Accessories for Sensor 7005 200220 Bracket for 7005 200590 Cable connection box for 7005 200595 Cable length not standard for 7005 690010 Cable for 7005 Accessories for Pressure TransmittersAccessories for Pressure Transmitters
Accessories for Pressure Transmitters
Accessories for Pressure TransmittersAccessories for Pressure Transmitters 202920 Cable length not standard 202922 Cable connection box for pressure transmitters 202923 As 202922, with plug for programming unit 691010 Cable for 7050 691014 Cable for 7060
Page 6
Ultrasonic sensor 7005Ultrasonic sensor 7005
Ultrasonic sensor 7005
Ultrasonic sensor 7005Ultrasonic sensor 7005
MountingMounting
Mounting
MountingMounting
The sensor is mounted near the top of the well or container where no tubes or cables obstruct the path between the sensor and the surface of the liquid. The maximum di­stance between the sensor and the surface of the liquid must not exceed 10 m. The best performance is obtained by placing the sensor 1 m above the maximum level desired (high alarm level). The sensor should be positioned at precisely perpendicular to the liquid surface (using a spirit level). There must allways be at least 75 cm from max level to the bottom of the sensor.
Where a sensor is mounted above an obstruction ex. a concrete deck, we recommend that it should be installed as shown below:
Table value +50%
If the upward edges cannot be angled as shown, the width should be table value +100%.
Min. 200 mm
Sensor mounted in tube for scum protection.
SpreadingSpreading
Spreading
SpreadingSpreading
The table shows the spreading of the sensor signal for different measuring ranges selected, and i.e. for different level values.
Min. 75 cm
o
45
Sensor mounted near the top of a closed container.
Table value +25%
When measuring through a hole in ex. a metal plate or grate, a pipe that ends near the end of the sensor should be applied as shown.
SpecificationsSpecifications
Specifications
SpecificationsSpecifications
Ultrasonic Sensor 7005-1013Ultrasonic Sensor 7005-1013
Ultrasonic Sensor 7005-1013
Ultrasonic Sensor 7005-1013Ultrasonic Sensor 7005-1013 Measuring range: 0,75 - 10 m Frequency: 30 kHz Beam spread: 3 Temperature: –20 - +60 OC Dimensions: ø103 x 94 mm Materials: Reflector: PP, green
Cable: 12 m shielded oilresistant PVC,
Housing: IP 68, waterproof,
O
Inner parts: POM, black.
can be extended to 100 m
withstands immersion max. 1 bar
45
o
Setting of zero levelSetting of zero level
Setting of zero level
Setting of zero levelSetting of zero level
Set the selector switch to „ZERO LEVEL“. Measure the distance from the lower edge of the sensor to the bottom of the pump well and set this in centimetres on the ZERO LEVEL potentiometer. If the well is empty, the following method may be used: Set the selector switch to position „LEVEL“. The sensor will then be working against the bottom of the empty well. The ZERO LEVEL potentiometer is now set to zero. To check this setting, turn the selector switch to „ZERO LEVEL“ and read the distance to the bottom in centimetres as displayed.
Page 7
PrPr
essuressur
Pr
essur
PrPr
essuressur
7050 / 70607050 / 7060
7050 / 7060
7050 / 70607050 / 7060
MountingMounting
Mounting
MountingMounting
The Pressure Trans­mitter is hung inside the well or container where measurement is desired. It is practical to mount it in a tube, fastening it at the top end of the tube by means of the fittings supplied as this facilitates subsequent cleaning and inspection.
e transmittere transmitter
e transmitter
e transmittere transmitter
Bracket
Min. 65mm inside
SpecificationsSpecifications
Specifications
SpecificationsSpecifications
Pressure Transmitter 7050 or 7060Pressure Transmitter 7050 or 7060
Pressure Transmitter 7050 or 7060
Pressure Transmitter 7050 or 7060Pressure Transmitter 7050 or 7060 Measuring ranges: 0-10m Pressure Transmitter 7050-1413,(absolute press.) 0-3m Pressure Transmitter 7060-1413,(gauge pressure) 0-10m Pressure Transmitter 7060-1423,(gauge pressure) 0-30m Pressure Transmitter 7060-1433, (gauge pressure) Function: 2-wire, 4-20 mA Accuracy: ±1% Temperature: –10 - +60 Dimensions: ø60 x 140 mm Materials: House: PP
Diaphragm: Acidproof steel, AISI 316 L
Cable: 2 x 0,5mm², length=12m
(with 7060-1433: 35m), can be extended Mounting: Immersed from supplied bracket Housing: IP 68, waterproof, max. 3 bar
O
C
Zero, span and response timeZero, span and response time
Zero, span and response time
Zero, span and response timeZero, span and response time
The response time is set to minimum at delivery. When replacing the Pressure Transmitter or when using the MJK 703P for differential level measurement or measurements in pressure or vacuum tanks, it may be necessary to set the zero point as well as the span. The setting is carried out by simulating the zero point and the span. Depending on the use, it may also be necessary to reset the response time. If the Pump Controller is used for liquids with a specific gravity different from that of water (e.g. sludge), the span will need to be adjusted.
Page 8