Trouble Shooting Chart
LED Indicator: Solid green LED indicates pump is powered and functioning properly. If flashing green LED please follow the Corrective Actions for the errors below.
Symptom LED Sequence Code
1x Long, 4x Short
1x Long, 3x Short, 1x Long
Intermittent Operation
Pump will not prime 1x Long, 1x Short, 2x Long, 1x Short Dry-Run Error
Little or no discharge Solid Light No Error
Noisy pump operation Solid Light No Error
No Operation No Light Not Powered
1x Long, 2x Short, 1x Long, 1x Short
1X Long, 2x Short, 2x Long
1x Long, 1x Short, 1x Long, 2x Short
1x Long, 1x Short, 1x Long, 1x Short, 1x Long
LED Sequence
Code Error
Run Error #1 Run Error #2 Run Error #3 Run Error #4 Run Error #5 Run Error #6
Possible Causes Corrective Action*
1. Improperly Wired
2. Foreign object in impeller and housing
3. Overheated pump electronics
1 . Leak, Obstruction, or kink in suction line 2 . Suction line closed
3. Pump is worn
1. Housing not filled with water
2. Suction piping too small
3. Total head too high
4. Impeller plugged
1. Air trapped in housing
2. Rotor bearing worn
3. Debris in housing
1. Blown Fuse or open circuit breaker
2. Loose or broken wiring
1. Check Motor wiring diagram
2. Disassemble pump, remove object, and clean motor separating wall and impeller
3. Disconnect the power to the pump and let the pump cooled down to ambient room temperature. Check the fluid’s temperature for proper setting.
1. Repair as necessary.
2. Open, then reset the pump by unplugging power
to the pump
3. Replace parts.
1. Properly prime housing
2. Increase to pump inlet size or one size larger
3. Reduce discharge head
4. Disassemble pump and clean motor separating wall and impeller
1. Check pump prime, also turn pump on and off several times to bump air pocket out of pump
2. Replace rotor assembly
3. Dissemble pump and remove debris
1. Replace fuse or circuit breaker after reason for overload has been corrected
2. Tighten connections, repair wiring
* If the LED sequence code continues after all corrective actions have been verified and applied, please contact your representative for assistance and report the run error sequence when the pump is returned for a warranty replacement.