GENERAL SPECIFICATIONS
All specifications are typical at nominal line, full load, and 25°C.
Efficiency: 70% minimum Vo > 12V
65% minimum on other models
Hold-up time:
PUP80 Series: 15msec minimum at 110 VAC
PUP130 Series: 10msec minimum at 110 VAC
Line regulation: ±0.5% maximum at full load
Inrush current: 15A@115 VAC, or 30A@
230 VAC at 25°C cold start
Withstand voltage: 3000 VAC from input to output
1500 VAC from input to ground
500 VAC from output to ground
Insulation resistance: 10 Mohm minimum from output
to ground
Operating temperature: 0°C to +60°C (PUP80 series)*
0°C to +70°C (PUP130 series)*
Storage temperature: –40°C to +85°C
Relative humidity: 5% to 95% non-condensing
MTBF: 100,000 hours minimum at
full load at 25°C ambient
EMI requirements: In compliance with radiated and
conducted limits of CISPR 22
(EN 55022) Class B and FCC Class B
Safety requirements: Approved to:
a) UL 1950
b) CSA C22.2 No. 234
c) IEC 950 (EN60950)
Switchng frequency 60KHz to 75KHz
INPUT SPECIFICATIONS
Input voltage: 85 to 132 VAC or 170 to 264 VAC
(auto-ranging)
Input frequency: 47 to 63 Hz
Input current:
PUP80 Series: 1.8A (rms) for 115 VAC
1.0A (rms) for 230 VAC
PUP130 Series: 3.0A (rms) for 115 VAC
1.7A (rms) for 230 VAC
Safety ground: 0.40mA max. @ 110VAC 60 Hz
leakage current: 0.80mA max. @ 240VAC 50 Hz
OUTPUT SPECIFICATIONS
Total output power: See rating charts
Ripple and noise: 1% peak to peak maximum
Overvoltage protection: Set at 112-132% of its
nominal output voltage
Overcurrent protection:
Protected under short circuit conditions
Temperature coefficient: ±0.04%/°C maximum
Transient response: Maximum excursion of 4% or better
on all models, recovering to 1% of
final value 500us after a 25% step
load change
Remote sense: Optional, please consult factory
*
PUP80: Derate linearly from 100% load at 40°C to 50% load at 60°C
*
PUP130: Derate linearly from 100% load at 50°C to 50% load at 70°C
MECHANICAL SPECIFICATIONS
PIN CHART
Model PIN 1 2 3 4 5 6 7 8
All Models RETURN RETURN OUTPUT RETURN OUTPUT RETURN OUTPUT OUTPUT
+V +V +V +V
NOTES:
1. Dimensions shown in inches (mm)
2. Tolerance 0.02 (0.5) Maximum
3. Optional output connectors available
4. Optional ON/OFF switch available
5. DC fan on PUP130 models only
2.50 (63.5)
AC INPUT IEC 320 INLET
99
Your Source of Power ...
260 Hopping Brook Road, Holliston, MA 01746
TEL: (508) 429-4440 FAX: (800) 226-2100
http://www.intlpower.com