XPiQ inc PUP130-12, PUP130-13, PUP130-13-1, PUP130-14, PUP130-16 Datasheet

...
DESCRIPTION
The PUP80/130 Series of AC-DC switching power supplies provide 60-130 watts of continous output power. They are enclosed in a 94V-1 rated polyphenylene-oxide case with an IEC320 inlet connector to mate with an interchangable cord for worldwide use. All models meet CISPR 22 and FCC Class B emission limits and comply with UL, CSA, IEC and CE requirements.
FEATURES
Built-in EMI filter
Overvoltage protection
Overcurrent protection
Auto-ranging input
Input surge current protection
100% burn-in at full load
Optional on/off switch
Output Maximum
Output
Model Vnom Imin Imax Tol. Power
PUP80-10 5V 0A 12A 2% 60W PUP80-10-1 7V 0A 8.6A 2% 60W PUP80-11 10V 0A 6.0A 2% 60W PUP80-12 12V 0A 6.7A 4% 80W PUP80-13 15V 0A 5.3A 3% 80W PUP80-13-1 18V 0A 4.5A 3% 80W PUP80-14 24V 0A 3.4A 3% 80W PUP80-16 30V 0A 2.7A 2% 80W PUP80-17 36V 0A 2.3A 2% 80W PUP80-18 48V 0A 1.7A 2% 80W PUP130-12 12V 0A 10.8A 5% 130W PUP130-13 15V 0A 8.6A 4% 130W PUP130-13-1 18V 0A 7.2A 4% 130W PUP130-14 24V 0A 5.4A 3% 130W PUP130-16 30V 0A 4.3A 3% 130W PUP130-17 36V 0A 3.6A 2% 130W PUP130-18 48V 0A 2.7A 2% 130W
OUTPUT VOLTAGE/CURRENT RATINGS CHART
NEW • UNIVERSAL INPUT
• DESKTOP POWER SUPPLIES
U
L
®
®
International Power Sources, Inc.
60-130 WATT
SWITCHING
POWER SUPPLY
98
GENERAL SPECIFICATIONS
All specifications are typical at nominal line, full load, and 25°C.
Efficiency: 70% minimum Vo > 12V
65% minimum on other models
Hold-up time:
PUP80 Series: 15msec minimum at 110 VAC
PUP130 Series: 10msec minimum at 110 VAC Line regulation: ±0.5% maximum at full load Inrush current: 15A@115 VAC, or 30A@
230 VAC at 25°C cold start
Withstand voltage: 3000 VAC from input to output
1500 VAC from input to ground 500 VAC from output to ground
Insulation resistance: 10 Mohm minimum from output
to ground
Operating temperature: 0°C to +60°C (PUP80 series)*
0°C to +70°C (PUP130 series)* Storage temperature: –40°C to +85°C Relative humidity: 5% to 95% non-condensing MTBF: 100,000 hours minimum at
full load at 25°C ambient EMI requirements: In compliance with radiated and
conducted limits of CISPR 22
(EN 55022) Class B and FCC Class B Safety requirements: Approved to:
a) UL 1950
b) CSA C22.2 No. 234
c) IEC 950 (EN60950) Switchng frequency 60KHz to 75KHz
INPUT SPECIFICATIONS
Input voltage: 85 to 132 VAC or 170 to 264 VAC
(auto-ranging) Input frequency: 47 to 63 Hz Input current:
PUP80 Series: 1.8A (rms) for 115 VAC
1.0A (rms) for 230 VAC
PUP130 Series: 3.0A (rms) for 115 VAC
1.7A (rms) for 230 VAC
Safety ground: 0.40mA max. @ 110VAC 60 Hz
leakage current: 0.80mA max. @ 240VAC 50 Hz
OUTPUT SPECIFICATIONS
Total output power: See rating charts Ripple and noise: 1% peak to peak maximum Overvoltage protection: Set at 112-132% of its
nominal output voltage
Overcurrent protection:
Protected under short circuit conditions Temperature coefficient: ±0.04%/°C maximum Transient response: Maximum excursion of 4% or better
on all models, recovering to 1% of
final value 500us after a 25% step
load change Remote sense: Optional, please consult factory
*
PUP80: Derate linearly from 100% load at 40°C to 50% load at 60°C
*
PUP130: Derate linearly from 100% load at 50°C to 50% load at 70°C
MECHANICAL SPECIFICATIONS
PIN CHART
Model PIN 1 2 3 4 5 6 7 8
All Models RETURN RETURN OUTPUT RETURN OUTPUT RETURN OUTPUT OUTPUT
+V +V +V +V
NOTES:
1. Dimensions shown in inches (mm)
2. Tolerance 0.02 (0.5) Maximum
3. Optional output connectors available
4. Optional ON/OFF switch available
5. DC fan on PUP130 models only
2.50 (63.5)
AC INPUT IEC 320 INLET
99
Your Source of Power ...
260 Hopping Brook Road, Holliston, MA 01746
TEL: (508) 429-4440 FAX: (800) 226-2100
http://www.intlpower.com
International
Power Sources, Inc.
Loading...