7373
73
GENERAL SPECIFICATIONS
All specifications are typical at nominal line, full load, and 25°C.
Efficiency: 65% minimum at 110W output
Hold-up time: 12 msec minimum
Line regulation: ±0.5% maximum at full load
Inrush current: 15 amps @ 115 VAC, or
30 amps @ 230 VAC at 25°C
cold start
Withstand voltage: 3000 VAC from input to output
1500 VAC from input to ground
Insulation resistance: 10 Mohm minimum from output
to ground
Operating temperature: 0 to 70°C*
Storage temperature: -40 to +85°C
Mean time between 100,000 hours at full load
failure: at 25°C ambient
EMI requirements: Meets conduction limits of
a) FCC 20780 Level B
b) CISPR 22 (EN 55022) Level B
Safety requirements: Meets or exceeds:
a) UL 1950
b) CSA C22.2 No. 234
c) IEC 950
INPUT SPECIFICATIONS
Input voltage: 85 to 264 VAC/115-370VDC
Input frequency: 47 to 440 Hz
Input current: 3.2A (rms) for 115 VAC
1.8A (rms) for 230 VAC
OUTPUT SPECIFICATIONS
Output voltage: See Rating Charts
Output current: See Rating Charts
Output power range: 0 to 110 watts at 25 CFM forced
air cooling, or 0 to 80 watts at
convention cooling
Ripple and noise: 1% peak to peak maximum
Overvoltage protection: Provided on output #1 only; set at
112-132% of its nominal
output voltage
Overcurrent protection: All outputs protected to short
circuit conditions
Temperature Coefficient: All outputs ±0.04%/°C maximum
* Derate linearly from 100% load at 50°C to 50% load at 70°C
PIN CHART
MECHANICAL SPECIFICATIONS
NOTE:
1. Dimensions shown in inch (mm)
2. Tolerance 0.02 (0.5) maximum
3. Input connector mates with Molex
housing 09-50-3051 and Molex
2878 series crimp terminal.
4. Output connector mates with Molex
housing 09-50-3131 and Molex
2878 series crimp terminal.
5. Weight 600 grams approx.
Model PIN 1,2,3 4,5 6,7 8,9 10 11 12 13
PU110-10-1A, PU110-10A, PU110-12A,
OUTPUT RETURN RETURN OUTPUT P.F.D. N.C. KEY N.C.
PU110-13A, PU110-14A, UP 110-16A
#1 #1
PU110-23A
OUTPUT COMMON COMMON OUTPUT P.F.D. N.C. KEY N.C.
#1 RETURN RETURN #2
PU110-31A, PU110-32A
OUTPUT COMMON COMMON OUTPUT P.F.D. OUTPUT KEY N.C
#1 RETURN RETURN #2 #3
PU110-40A, PU110-42A, PU110-45A,
OUTPUT COMMON COMMON OUTPUT P.F.D. OUTPUT KEY OUTPUT
PU110-45-1A, PU110-45-2A, PU110-46A
#1 RETURN RETURN #2 #3 S #4
Your Source of Power ...
260 Hopping Brook Road, Holliston, MA 01746
TEL:(508) 429-9883 FAX:(800) 226-2100
http://www.intlpower.com