Xpelair LVDX200, LVCF20T, LVDX200T Installation And Maintenance Instructions Manual

Page 1
‘‘``````
567-2069-01
Revision D
8
UK: The fan is guaranteed against defects for 3 years from the date of purchase.
• Xpelair reserve the right to repair or replace the fan.
• Keep your purchase receipt.
UK: Xpelair have a comprehensive range of services including:
• Free technical advice Help-Desk from Engineers on all aspects of ventilation
• Free design service, quotations and site surveys Outside UK: See International section below. Please ask for details on:
Tel +44 (0) 8709 000430 Fax +44 (0) 8709 000530
Also at the address below
Applied Energy Products Ltd, Morley Way, Peterborough, PE2 9JJ, England
Tel: +44 (0) 1733 456789 Fax: +44 (0) 1733 310606 Sales/Spares Hotline: +44 (0) 8709 000420 Sales/Spares Faxline: +44 (0) 8709 000520 Web: http:/www.xpelair.co.uk
Guarantee
Technical Advice & Service
International
Head Office – UK Sales Office and Spares
Guarantee – Contact your local distributor or Xpelair direct Technical advice and Service – Contact your local Xpelair distributor.
Xpelair
Safety Extra Low Voltage Centrifugal Ducted Fans
• LVDX200 Standard
LVDX200T Timer
Condensation Control Fans
• LVCF20 Pull Cord
LVCF20T Pull Cord/Timer
Installation and Maintenance Instructions
Retain for future reference
Page 2
For speed and ease of installation, your installation may require some of the Ancillaries indicated in “Ancillary Options”.
.
1. Mark on the wall the centre of the duct hole A.
2. Use this centre to cut an opening through the
wall 117mm dia. with a slight fall to the exterior.
3. Fit the wall tube (not supplied), and motar into
place.
1. Mark on the wall the centre of the duct hole A,
and drill a pilot hole through both walls.
2. Use the centre to mark a rectangular hole for
the inner wall using the dimensions A.
3. Cut the rectangular hole through the inner
wall.
4. Go outside and cut a 117mm diameter hole in
the outer wall using the small hole as the centre.
5. Measure the wall thickness.
6. Cut the wall tube (not supplied), so that it is
64mm less than the wall thickness.
This method requires a space above the ceiling, such as a loft or attic, to provide access for 100mm internal diameter ducting.
1. Mark on the ceiling the centre of the duct hole
A, avoiding ceiling joists and buried cables
etc.
2. Cut a 117mm diameter hole using the marked
centre.
For 100mm diameter ducting: This method requires a space above the ceiling, such as a loft or attic, to provide access for 100mm internal diameter ducting.
1. Mark a rectangular hole using the dimensions
B.
2. Cut the hole, avoiding ceiling joists and buried
cables etc.
For flat ducting:
This fan can be installed within a 50mm void without the circular spigot ? (Fig. E). Flat ducting adapter kit (FDA) available.
1. Remove the front cover (Fig. C)
2. Fit the foam tape supplied around the
circular spigot ? (Fig. E).
3. Remove the electrical cover (Fig. E). The
impeller can be removed to ease access (if required). This is a push on/pull off assembly.
LVCF20 / LVCF20T Only (Fig. D)
4. The correct condensation control speed should
be selected to suit the room size in which the fan is to be installed. Slide the switch X to the required position. Please note that the fan is factory set to “Position 2”.
5. Switch Position Size / Room Volume (m³)
1 Large (34 and above) 2 Medium (28 – 34) 3 Small (less than 28)
LVCF20 / LVCF20T Only (Fig. D)
6. The fan can be set so that it provides constant
trickle extraction. Slide the switch Y to the required position. Please note that the fan is factory set to “Position 0”.
7. Switch Position Setting
0 Trickle extraction OFF 1 Trickle extraction ON
LVDX200T / LVCF20T Only (Fig. D)
8. The fan can be set so that there is a 2-minute
delayed start to its operation when used with an external on/off switch. Slide the switch Z to the required position. Please note that the fan is factory set to “Position 0”
9. Switch Position Setting
0 Time delay start OFF 1 Time delay start ON
The fan must not be mounted where ambient temperatures are likely to exceed 40°C.
1. Place the ducting into the hole and align to the
required position. If wall mounting, ensure that the ducting slopes down and away from the fan.
2. Mark the positions of the three fixing holes A in fan box ? (Fig. E).
3. If wall mounting, drill three holes 5.5mm diameter for wall plugs (supplied). If ceiling mounting B, use appropriate fasteners (not supplied).
4. Cut out the cable inlet hole, if required, in the surround ? and slit the cable grommet. Slide the surround ? over the fan box ?.
5. Pass the electrical cables into the fan box ? through the rear cable inlet hole and surround, and re-fit the cable grommet. Ensure that the cable grommet is in place and a tight fit.
6. Offer the fan box ? up to the wall or ceiling. Ensure the circular spigot ? enters the ducting.
7. Fix the fan box ? to the wall using screws ? or to the ceiling using appropriate fasteners (not supplied).
The surround ? is not required. Fit the ducting to the circular spigot ?.
If the hole size is as recommended:
1. Assemble the three fan body clamps ? to the fan box ? using screws ?.
2. Slit the cable grommet. Pass the electrical cables into the fan box ? through the cable inlet hole and cable grommet.
Ensure cable grommet is in place and a tight fit.
3. Offer the fan box ? up to the wall.
4. Tighten up the three screws ? until the fan is clamped to the inner wall. The fan body clamps ? will rotate to an automatic stop position. DO NOT OVERTIGHTEN.
If the hole size is larger than recommended i.e. larger than the flange on the fan box ? (Mostly related to “retro-fit” installations):
1. The fan body clamps ARE NOT suitable. Construct a wooden frame of INTERNAL dimensions 203 x 233mm. Depth should be at least 50mm. Fit the wooden frame into the internal wall and make good the hole.
2. Offer the fan box ? up to the wall.
3. Screw the fan box ? to the wooden frame using the slots in the flange (screws not supplied).
1. The surround ? is not required.
2. Insert the fan box ? into the hole and mark four positions using the slots in the flange B.
3. Remove the fan box ? from ceiling and fit the four ceiling clips (supplied) over the edge of the hole, so that the clips align with the marks on the ceiling B.
4. Drill 4 pilot holes into the ceiling through the hole of each clip, ensuring not to damage the clip, and fit the clips ensuring correct alignment.
5. Fit the ducting to the circular spigot ?.
6. Offer the fan box ? up to the ceiling.
7. Slit the cable grommet. Pass the electrical cable into the fan box ? through the front cable inlet hole.
Ensure cable grommet is in place and a tight fit.
8. Using the screws 11 (Fig B), fix the fan box flange to the ceiling clips.
Fit an outer grille (CF20 variants only) to the outer wall. For ceiling mounting, use appropriate ancillaries (not supplied).
The transformer A can be fixed directly to the wall. The transformer can be sited in a loft or in a convenient position on a wall (not ceiling). The
transformer must not be covered by loft insulation. For wall mounting the Fan must be orientated as shown in H to fulfil ingress protection requirements.
IMPORTANT
1. READ ALL THESE INSTRUCTIONS & WARNINGS FULLY BEFORE COMMENCING INSTALLATION.
2. INSTALLATIONS AND WIRING MUST CONFORM TO CURRENT IEE REGULATIONS (UK), LOCAL OR APPROPRIATE
REGULATIONS (OTHER COUNTRIES). IT IS THE INSTALLER’S RESPONSIBILITY TO ENSURE THAT THE APPROPRIATE BUILDING CODES OF PRACTICE ARE ADHERED TO.
3. A QUALIFIED ELECTRICIAN MUST SUPERVISE ALL INSTALLATIONS.
4. THESE APPLIANCES ARE INTENDED FOR CONNECTION TO FIXED WIRING.
5. CHECK THAT THE ELECTRICAL RATING SHOWN ON THE TRANSFORMER MATCHES THE MAINS SUPPLY.
6. SITE BOTH FAN AND TRANSFORMER AWAY FROM DIRECT SOURCES OF HEAT (I.E. GAS COOKERS OR EYE LEVEL
GRILLES. THE FAN MUST NOT BE MOUNTED WHERE AMBIENT TEMPERATURES ARE LIKELY TO EXCEED 40ºC. THE TRANSFORMER MUST NOT BE MOUNTED WHERE AMBIENT TEMPERATURES ARE LIKELY TO EXCEED 40ºC.
7. WHEN THE FAN IS INSTALLED IN A ROOM CONTAINING A FUEL BURNING APPLIANCE, THE INSTALLER MUST ENSURE
THAT AIR REPLACEMENT IS ADEQUATE FOR BOTH THE FAN AND THE FUEL BURNING APPLIANCE.
8. ENSURE THAT ALL RELEVANT SAFETY PRECAUTIONS (CORRECT EYE PROTECTION AND PROTECTIVE CLOTHING ETC)
ARE TAKEN WHEN INSTALLING, OPERATING AND MAINTAINING THIS FAN.
9. GENERAL GUIDANCE FOR SITING THE FAN SEE “FIG.G”. ALWAYS SITE FAN AS HIGH AS POSSIBLE.
10. IF ANY SECTION OF THE DUCTWORK IS POSITIONED HIGHER THAN THE FAN A CONDENSATION TRAP (XCT100) MUST BE
FITTED AS CLOSE AS POSSIBLE TO THE FAN.
11. THIS APPLIANCE IS NOT INTENDED FOR USE BY YOUNG CHILDREN OR INFIRM PERSONS WITHOUT SUPERVISION. YOUNG
CHILDREN SHOULD BE SUPERVISED TO ENSURE THEY DO NOT PLAY WITH THE APPLIANCE.
If installing the fan on a wall (surface mounting)
If installing the fan in a wall (flush mounting)
If installing the fan on a ceiling (surface mounting)
If installing the fan in a ceiling (flush mounting)
Preparing the fan for installation
Setting the condensation speed
Setting the trickle speed
Setting the time delay start
Mounting the Fan
Mounting the fan on a wall or ceiling (surface mounting)
If mounting the fan in a wall (flush mounting)
If mounting the fan in a ceiling (flush mounting)
Terminating the ducting
Mounting the transformer
2
7
F
Page 3
E
G
6
The transformer must also not be mounted within 0.6m of a bath or shower cubicle, up to a height of 2.25m. The transformer must not be mounted where ambient temperatures are likely to exceed 40°C.
1. Remove the two screws securing the cover,
remove cover.
2. Position the transformer on the wall, and mark
the two fixing holes.
3. Drill and plug the two holes and fix the
transformer with the screws supplied.
For loft mounting: The transformer can be fixed to a wooden surface with the two screws supplied.
For fixed surface wiring:
Use the rectangular knockouts on each side (X). These accept 25 x 16mm trunking (not supplied)
For concealed wiring:
Use the round knockouts (Y).
For connection to a window mounted fan:
Use knockout (Z). Use flexible cable. When using the side entries with flexible cable, a hole suitable for the cable size must be made centrally in the rectangular section.
1. Isolate the electricity supply and remove all
fuses. The terminal block will accept cable up to
1.5mm².
2. A means for disconnection in all poles must be
incorporated in the fixed wiring in accordance with the wiring rules.
3. Use suitably rated 3-core or 4-core cable
dependent on application.
4. Remove the retaining screws of the terminal cover , if still in position.
5. Wire the fan as shown in F using the cable clamp provided. Check fan model to diagram. LVDX200T: “LH” = Live (High Speed) / “LL” = Live (Low Speed)
6. Replace the terminal cover and fasten the retaining screws.
7. See section on “User adjustments” if you wish to use settings other than those that have been factory set.
8. Refit the front cover (Fig. C).
9. Connect the cable from the isolating switch to electrical supply wiring, and re-check installation.
10. Refit fuses before turning on electricity supply.
11. For fixed wiring circuits, the protective fuse for the appliance must not exceed 5A.
For Australia Only LVCF20 – Connection to the supply – flexible 3-
core cable with 3 pin plug top for insertion into an approved 10A wall mounted surface switch with at least 3mm clearance between contacts. ALL OTHERS – Permanently connected to the supply and a remote switch controls operation. They should be directly wired to the supply through an approved 10A wall mounted surface switch with at least 3mm clearance between contacts.
Always wire via the cable clamp.
1. Remove the cable clamps.
2. Wire the transformer as shown in F. Check the fan model to diagram.
3. Ensure all connections are tight.
4. Replace the clamps and two screws. Ensure the cable is firmly retained by the clamp.
5. Replace the transformer cover with the two screws.
6. Switch off the mains electrical supply and remove fuses.
7. Connect the cable from the isolating switch to the electrical supply wiring.
8. For fixed wiring circuits the protective fuse for the appliance must not exceed 5A.
Before making any adjustments, isolate the fan completely from the mains supply, check specification below to see which features apply to your fan.
1. Remove the front cover and replace after
adjustment (Fig. C).
There are no user adjustments for the LVDX200 fan.
1. The timer over-run period can be adjusted
between approximately 30 seconds and 20 minutes. Use an electrician’s screwdriver and turn screw “T” (Fig. D), clockwise to increase time, anti-clockwise to decrease. (Factory preset to approximately 10 minutes).
1. The humidity setting is adjustable between
approximately 50% and 90% relative humidity. Use an electrician’s screwdriver, and turn screw “RH” (Fig. D), clockwise to increase the relative humidity setting and anti­clockwise to decrease. (Note: the fan is more sensitive at 50% RH than at 90%).
1. The timer over-run period can be adjusted
between approximately 30 seconds and 20 minutes. Use an electrician’s screwdriver and turn screw “T” (Fig. D), clockwise to increase time, anti-clockwise to decrease. (Factory preset to approximately 10 minutes).
2. The humidity setting is adjustable between
approximately 50% and 90% relative humidity. Use an electrician’s screwdriver, and turn screw “RH” (Fig. D), clockwise to increase the relative humidity setting and anti­clockwise to decrease. (Note: the fan is more sensitive at 50% RH than at 90%).
Operate the fan using the external On/Off switch. Repeat to switch off. The fan speed is pre-set by the Installer to either high or low speed. Both speeds can be selected when wired through a change over switch Part No. 90108AW.
Operate the fan using the external on/off switch. Repeat to switch off. When the switch is turned off, the fan continues to operate for the selected over-run timer period. Top light “I” is lit when the external on/off switch is turned on. The fan speed is pre-set by the installer to either high or low speed. (If a change over switch has been installed then the user can switch between high speed and low speed.)
Time delay start feature on or off
This is set by the installer to provide a 2-minute time delay start when the fan is switched on using the external on/off switch.
Switched Operation
The fan can be wired with a separate on/off switch. Fan operates at condensation speed when switched on. Top light “I” is lit when the separate on/off switch is switched on. When switched off, the fan will continue to operate if the humidity level has not reached that set by adjusting screw “RH”. LVCF20T only: When switched off, the fan continues to operate for the adjustable timer over­run period.
Condensation Operation
The fan operates at condensation control speed, when the relative humidity exceeds the set level, and turns off when the humidity drops.
Boost Operation
The integral pull cord switch switches the fan to run at high speed. Bottom light “II” is lit when the fan is
operating at high speed. Note: If the separate on/off switch and integral pull cord are both on, the lights “I” and “II” will both be lit and the fan will run at high speed.
Trickle feature on or off
This is set by the installer to provide continuous background extraction, when the humidity level is below that set by adjusting screw “RH”.
Time delay stat feature on or off
This is set by the installer to provide a 2-minute time delay start when the fan is switched on using a separate on/off switch.
1. Before cleaning, isolate the fan completely
from the mains supply.
2. Only clean the external surface of the fan,
using a damp lint free cloth.
3. Do not use strong detergents, solvents or
chemical cleaners.
4. Allow the fan to dry thoroughly before use.
5. Apart from cleaning, no other maintenance is
required.
See Diagram E
1. Baffle Plate
2. Front Cover
3. Impeller
4. Fixing Screws
5. Terminal Cover
6. Fan Box
7. Circular Spigot
8. Clamp screws and wall plugs – 3 off
9. Fan body clamps – 3 off
10. Surround
11. Ceiling screws 25mm long - 4 off (Diagram B)
12. Foam Tape
PLEASE LEAVE THIS LEAFLET WITH THE FAN FOR THE BENEFIT OF THE USER
For speed and ease of installation, your installation may require some of the Ancillaries listed below:
WD100 Wall Duct CFWG100 Wall Grille XCT100 Condensation Trap DGW/B Air Replacement Grille SP100 Spigot Plate XAA Air Brick Adaptor VC10 Vent Cowl WT10 Termination Ducting Kit XF/FM Flat Ducting (Plastic/Metal)
(Plastic 234x29
Metal 230x25)
VK10 Wall Vent Kit FD100 Flexible Ducting WDC5 Worm Drive Clips XCMK Ceiling Mounting Kit XBP In-Line Back Draught Shutter EFT Easy Fit Termination Kit GMK Glass Mounting Adaptor PDXGF Grease Filter FDA Flat Duct Adaptor Kit
Spares
Listed below are some of the spares available. See back page of this booklet for ordering details:
41756SK Motor (LVDX200T) 41757SK Motor (LVCF20/LVCF20T) 41758SK PCB Assy. (LVDX200T) 41759SK PCB Assy. (LVCF20) 41760SK PCB Assy. (LVCF20T) 41769SK Front Cover c/w Baffle
(LVDX200T)
41770SK Front Cover c/w Baffle
(LVCF20 / LVCF20T)
41740SK Surround Moulding (Entire Range) 41741SK Pull-Cord Assembly (Entire Range) 41742SK Impeller (Entire Range)
Fixing the transformer directly
Wire the Fan
Wire the Transformer
User adjustments
LVDX200
LVDX200T
LVCF20
LVCF20T
Using the Fan
LVDX200
LVDX200T
LVCF20 / LVCF20T
LVCF20T only
Cleaning
Key
Ancillary Options
3
Page 4
A
B
4
C
D H
5
Loading...