Disconnect the fan from power mains prior to any connection, servicing and repair operations. Mounting and maintenance are allowed for duly qualified electricians with valid electrical work permit for electric operations at the units up to 1000 V after careful study of the present user
s manual. The single-phase power mains must comply with the acting local electrical norms and standards. The fixed electrical wiring must be equipped with an automatic circuit breaker. The fan must be connected to power mains through an automatic circuit breaker
F integrated into the fixed wiring system with the gap
between the breaker contacts on all poles not less than 3 mm.
heck the fan for any visible damages of the impeller and the casing before starting installation. The casing internals must be free of any foreign objects which can damage the impeller blades. Misuse of the device or any unauthorized modification is not allowed.
The fan is not to be used by children and persons with reduced physical, mental or sensory capacities, without
proper practical experience or expertise, unless they are controlled or instructed on the product oper
ation by the person(s) responsible for their safety. Do not leave children unattended and do not let them play with the product.
Take steps to prevent ingress of smoke, carbon monoxide and other combustion products into the room through open chimney flues or other fire-protection devices. Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting.
Transported medium must not co
ntain any dust or other solid impurities, sticky substances or fibrous materials. Do not use the fan in the environment containing hazardous or explosive materials and vapours, i.e. spirits, gasoline, insecticides, etc. Do not close or block the fan intake or extract vents in order to ensure the most effective air passage. Do not sit on the fan and do not put objects on it. Fulfill the requirements stated in this user
s manual to ensure long service
life of the product.
3
Xpelair X X
Fan series - AirLine AL100, AirLine LED ALL100
Extra options: T - turn-off delay timer (only for AL100T & ALL100T)
Designation key example:
AirLine AL100T - fan with inlet spigot diameter 100 mm, AirLine series, equipped with a fixing bracket and a turn-off delay timer.
FAN DESIGNATION KEY
EN
4
Read the present user manual carefully befor e proceeding with installation works. Compliance with the manual r
ements ensures reliable operation and long service life of the pr oduct. Keep the user's manual available as long as you use the product. You may need to re-r ead the information on the product servicing.
DELIVERY SET
The delivery set:
1. Fan - 1 item;
2. Screws and rawl plugs (only for the models with the fixing bracket) - 4 items;
3. Plastic screwdriver - 1 item (only for the models with a timer);
4. Sealer - 2 items;
5. User manual;
6. Packing box.
BRIEF DESCRIPTION
The product described herein is an axial fan for supply and exhaust ventilation of small and medium-sized premises. The fan is made of white plastic. The fan is designed for connection to 100mm air ducts.
Due to constant improvements the design of some models may slightly differ from those ones described in this manual.
OPERATION GUIDELINES
The fan is designed for connection to AC 220-240 V, 50 Hz power mains.
The fan is designed for continuous oper ation always dir
connected to power mains. Air flow
ection in the system must match the pointer direction on the fan casing.
Ingress protection rating against access to hazardous parts and water ingress - IPX4.
The fan is rated for operation at the ambient temperature ranging fr om +1 °C up to +45 °C.
EN
The fan is designed for vertical or horizontal installation inside the round air duct of respective diameter , fig. 1. Fan mounting sequence: Step 1 - Disconnect power supply. Fig. 2; Step 2 - Mark and drill holes for fastening of the fixing bracket, install the fan. Fig. 3-5. Step 3 - Remove the electrical cover on the fan terminal box (wired to the fan) and on the Light terminal box (if applicable). Remove cable clamps. Fig 6-7. Step 4 - Connect the mains supply to the terminal block in the terminal box(es) as shown in the wiring diagrams. Re-install cable clamp. For Timer setting adjustment on Timer models, the electrical compartment cover on the fan will need to be removed to access the timer adjustment. Fig 8-10. Step 5 - Re-fit electrical covers to both fan and terminal box (as required). Step 6 - connect air ducts of r Step 7 - Cut a 100mm diameter hole in the ceiling in the appropriate position for the internal grille - ensure the hole lies between roof joists. Fix internal grille/fan light to ceiling using appropriate fastenings. Step 8 - Cut a hole to suit the External Grille in the required position. Fit using appropriate fastenings. Step 9 - Connect air ducts to internal and external grilles and secure with cable ties supplied. Step 10 - For LED versions remove the electrical cover on the LED Driver terminal box (wired to fan). Remove cable clamp and wire according to wiring diagrams Fig. 8-9. Re-install cable clamp and re-fit electrical cover. Step 11 - Connect the fan to the power mains. Fig.14
espective diameter on both sides of the fan. Fig. 13.
L - Live N - Neutral ~ - power mains
L
- timer contr ol line QF - automatic circuit breaker S - external switch
ELECTRONICS OPERATING LOGIC
The fan with the timer T - the fan starts after the external switch, e.g. the light switch, supplies control voltage to the input terminal L T (ST). After the control voltage is off, the fan continues operating within the set time period adjustable from 2 to 30 minutes by the timer.