Xerox 6115 User Manual

Installation Preparation Document (for physical installation of the product only)
Xerox DocuTech 6100/6115/6135
Customer Support
United States 1-800-821-2797
Your Xerox Analyst will provide fee-based training upon request.
Space Requirements
The diagram below is provided as a representation only of the space envelope required for installation of Xerox equipment. Diagram is a representation only and not drawn to scale.
D
DocuT ech 61xx
WIDTH
Representation only.
Note: The 6100, 6115, 6135 are available with and without a stand to
E P T H
support the controller. If a stand is ordered, it will be positioned to the left of the printer, within the service space envelope. If no stand is ordered, the controller will be placed on the floor to the left of the printer in the service space envelope. Note: The dimensions shown below provide the overall service space required, including the space to the nearest obstruction. The dimensions are in inches and are absolute minimums.
Configuration
6100, 6115, 6135
With stand Without stand
Width Depth Width Depth
243.0" 114.0” 240.0” 114.0" with interposer, and Finisher
6100, 6115, 6135
196.0" 114.0” 193.0” 114.0" without Interposer, with Finisher
Electrical Requirements
Printer/Finisher/Binder
Line Options: Single
Source
Voltage 208/240 Amperage 50 Cycles 60 Hz Receptacle Xerox Part No. 600S3779 Receptacle NEMA Part No. 14-50R Power Cord Xerox Part No. 98K19950
117K9940
Receptacle Diagram
* Dedicated power outlets required. Ensure each power cord has a separate
circuit that cannot be shared with other devices. *15 ft. power cord(s) are provided, however, the distance from the equipment to the outlet should not exceed 13.1 ft.
Electrical Requirements
Digital Front End (DFE) Controller Platform:
Line Options: Dedicated
Voltage 110V Amperage 15 Cycles 60 Hz
15 amp Receptacle Xerox Part No. 20 amp Receptacle Xerox Part No.
600S3704 600S3703
Receptacle NEMA Part No. 5 - 20R or 5 - 15R Receptacle Diagram
or
All controller configurations require a 110VAC, 15 Amp grounded receptacle for the outlet strip that provides
for the
controller and its peripheral devices (monitor, modem,
receptacles
CDROM drive, and tape drive)
Adapters that eliminate the ground connection to the outlet can not be used.
Xerox provides 15 feet of cabling with Teflon coating (Plenum rated), to connect the controller to the Processor/Finisher.
Interposer
Line Options:
Voltage 120 Amperage 15 Cycles 60 Hz Receptacle Xerox Part No. 600S3704 Receptacle NEMA Part No. 5 - 15R Power Cord Length 6 feet Receptacle Diagram
Dedicated
Installation Considerations
There should be a minimum of 78 inches (1,981mm) clearance from the floor to the nearest overhead obstruction.
Mobility Assist Device - The optional mobility assist device reduces the installation clearance required to 30 (760mm) at the processor end of the printer and 15 inches (380 mm) at the finisher end.
For proper operation, the printer must be perfectly level. The floor must be level within 2 degrees in any direction. On floors less than 2 degrees out of level, installation personnel install a leveling kit to level the machine.
If the floor is more than 2 degrees out of level, this condition cannot be corrected by the leveling kit. Another suitable location must be found for the printer to be installed properly.
A minimum 50-inch clearance of exclusive operator area must be maintained in front of each component. This space cannot be shared.
A minimum of 36 inches of clearance is required in the back of each component for general service clearance.
inches
701P43857
June 2005
Please ensure electrical, space, and supplies are available prior to equipment delivery.
Installation Preparation Document (for physical installation of the product only)
Xerox DocuTech 6100/6115/6135
Physical requirements
The DocuSP Controller Monitor and Keyboard are designed to be positioned on top of the DocuTech 61XX printer. The controller platform is designed to either be mounted in a stand to the left of the printer, or to be positioned on the floor to the left of the printer.
Warning: Due to safety requirements, under no circumstances should the user interface be visually separated from the printer module. All system installations must enable mobility of the user interface to within 30” (760 mm) of the printer for service and customer maintenance actions
.
Environmental Requirements
Min. Max.
Temperature 50
o
F 85 o F * Humidity 30% RH 60% RH Heat Emission - with
Binder On Heat Emission - with
Binder Off Power Consumption
Printer/Finisher w/ Binder
22,165
BTU/Hr
21,265
BTU/Hr
1,330 Watts
(Standby)
14,185 BTU/Hr (With Vent Kits)
13,609 BTU/Hr (With Vent Kits)
5,890 Watts
(Running)
On Power Consumption
Printer/Finisher w/Binder
1,000 Watts
(Standby)
5,630 Watts
(Running)
Off
* The system will inhibit software problems and shut down above 90 o F
Operating Supplies
Reorder No. Impressions / Unit
Dry Ink 6R206 220K/Carton at 6%
area coverage Developer 5R161 750K / Carton Fuser Agent 8R2955 250K / Bottle Stitcher Wire 8R1174 32K / Roll Binder Tape - Black 8R2928 425 Binds / Reel Binder Tape – White 8R3601 425 Binds / Reel Binder Tape – Gray 8R3602 425 Binds / Reel Binder Tape – Blue 8R3603 425 Binds / Reel Binder Tape – Brown 8R3604 425 Binds / Reel Binder Tape – Red 8R3824 425 Binds / Reel
The Xerox Supplies Marketing Center, 1.800.822.2200, is available for ordering Xerox supplies, including paper and other thruput material.
Network Requirements
The Ethernet interface on the DocuSP controller is a 10/100­MB/sec twisted pair standard (10BaseT).
The Ethernet connection to the DocuSP controller must be compatible with the Institute of Electrical and Electronics Engineers (IEEE) 802.3 standard. (The physical form of this connecter is RJ45 and must be correctly wired.)
The DocuSP controller supports TCP-IP, SPX,/IPX, and EtherTalk Link Access Protocol (ELAP) protocols if the proper gateways are installed on the controller.
The DocuSP controller does not provide Novell
Server network services. To use the SPX/IPX protocol, a Novell server installed on the network is required.
A Xerox Token Ring solution is available for the 61XX family. When Token Ring is installed, it becomes a Token Ring
only connectivity solution. The NetWare gateway and AppleTalk gateway will not function, and the built in Ethernet bge0 twisted pair interfaces are disabled. (Gigabit Ethernet is supported with a Sun controller card – some customers have asked for this option.)
Telephone Requirements
A voice telephone line is required where the DocuTech 6100, 6115, 6135, is installed. Voice line will be used when the operator, administrator, or Xerox Service Personnel is asked to read the screen information from the DocuSP controller dialogs to Xerox Customer Support or Technical Support Center Personnel.
Position / Performance at Maturity
8 7 6
Average
5
Monthly
4
Service Calls
3 2 1
300K 1M 2M
500K 1.5M
Average Monthly Copy Volume
Note: This product is targeted for the 300K to 2M copies per month market segment. Usage above this range may result in a higher service frequency
Optimum Range
701P43857
June 2005
Please ensure electrical, space, and supplies are available prior to equipment delivery.