Xerox 2830 User Manual

Product Safety Data Sheet XEROX
Product: 2830 PSDS No.: 0611
ISSUE DATE: 1/17/83 REV. DATE: 2/26/90
Section I - Product Identification
Manufacturer's Name Emergency No. EH&S Inquiries
Xerox Corporation (585) 422-2177 (800) 828-6571
Rochester, New York 14644
Product Designation Product Code
2830 19
Section II - Electrical Information
Line Voltage Line Current Freq. Branch Cir. Protection
(Volts) (Amps) (Hertz) (Amps)
115 20 60 15A Multi-use
Line Cord / Plug Specification Power Consumption (Watts)*
Single Phase 2 Wire +Ground Running: 1,380 NEMA 5-15R / 5-20R Standby: 250
Agency Approvals UL File Number E24014 CSA LR Number LR2196 / LR45955
Section III - Supplies
Xerox Part No. Material Safety Data Sheet
Dry Ink, Black 6R283, 6R522 A-0020 Dry Ink, Red 6R117 A-0026 Dry Ink, Blue 6R115 A-0027 Dry Ink, Green 6R116 A-0028 Developer, Black 5R283 B-0224 Developer, Red 5R128 B-0225 Developer, Blue 5R131 B-0226 Developer, Green 5R132 B-0227 Photoreceptor 1R67 Article ** (C24)
Section IV - Environmental Information
Product Size Heat Emission* Environmental Limitations
(Centimeters/Inches)) (BTU/HR) Min Max
D: 60.0 / 23.6 Running: 5,241 Relative Humidity (%)15 65 W: 51.5 / 20.2 Standby: 780 Ambient Temp. (oC) 10 32 H: 30.5 / 12.0
* Based on a five-minute average ** MSDS is not required by OSHA, Hazard Communication Std., 29CFR or WHMIS HPA (Section II (2)
www.xerox.com Reference “About Xerox”
PRODUCT: 2830 PSDS No. 0610
Floor Space Requirements Weight
(Meters/Feet) (K Grams / Lbs.)
1.60 x 1.80 (stationary / 8.3 x 5.9 75 / 165
1.42 x 1.47 (movable on stand) / 4.6 x 4.8
Section V - Emission/Exposure Information*
Light Source
Quartz Halogen - Long time viewing may be uncomfortable, but not harmful
Electromagnetic Emissions
FCC: Class A VDE: Class A
Audible Noise TLV
Run: 55.0 dB (A) 85 dB (A) Standby 38.0 dB (A) Impulse: 65.0 db (A)
Ozone TLV
480 ug/min 0.1 ppm
0.044 ppm (TWA)
0.097 ppm (Peak) Concentration Based on Customer Simulation Model:
Daily Copy Volume 571 copies/7.5 hours Room Size 5.0 m
3
1/2 Air Room Change per Hour
Dust TLV
0.01 - 0.3 mg/m3 (Black) 10 mg/m
0.03 - 0.04 mg/m3 (Red)
0.03 - 0.04 mg/m
0.0 - 0.012 mg/m
Selenium TLV
0-0.05 ug/m
Arsenic PEL
<0.01 ug/m
Tellurium TLV
0.01 ug/m
* TLV (Threshold Limit Value) and PEL (Permissible Exposure Level) respectively set by American Conference of Government Industrial Hygienists and by Occupational Safety and Health Administration. These levels are considered maximum exposure permitted to ensure no health hazard. TWA (Time Weighted Average) for a normal eight hour workday.
3
3
3
3
(Green)
3
(Blue)
200 ug/m
10 ug/m
3
3
3
All measurements were made on products performing within established operating specifications and received recommended maintenance procedures. Xerox certifies that this product meets or exceeds the applicable standards for safety and emissions.