Wolf VC48S, VC36S Installation

4 (1)
CEILING-MOUNTED HOOD
INSTALLATION GUIDE
SPECIFICATIONS, INSTALLATION, AND MORE
CEILING-MOUNTED HOOD
2
|
Wolf Customer Care 800.222.7820
Important Note
and efciently as possible, take note of the following types
of highlighted information throughout this guide:
IMPORTANT NOTE highlights information that is especially
important.
CAUTION indicates a situation where minor injury or product
damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or
death if precautions are not followed.
IMPORTANT NOTE: Throughout this guide, dimensions in
parentheses are millimeters unless otherwise specied.
IMPORTANT NOTE: Save these instructions for the local
electrical inspector.
Contents
3 Ceiling-Mounted Hood
4 Site Preparation
6 Specications
8 Hood Installation: Internal Blower
11 Hood Installation: In-Line/Remote Blower
14 Troubleshooting
Features and specications are subject to change at any
time without notice. Visit wolfappliance.com/specs for the
most up-to-date information.
wolfappliance.com
|
3
Product Information
Important product information, including the model and
serial number, are listed on the product rating plate. The
rating plate is located under the left side of the hood, above
the lters (lters must be removed). Refer to the illustration
below.
If service is necessary, contact Wolf Factory Certied
Service with the model and serial number. For the name of
the nearest Wolf Factory Certied Service or for questions
regarding the installation, visit the contact and support
section of our website, wolfappliance.com, or call Wolf
Customer Care at 800-222-7820.
CEILING-MOUNTED HOOD
IMPORTANT INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
a) Installation work and electrical wiring must be
done by qualied person(s) in accordance with
all applicable codes and standards, including
re-rated construction.
b) Sufcient air is needed for proper combus-
tion and exhausting of gases through the ue
(chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment
manufacturer’s guideline and safety standards
such as those published by the National Fire
Protection Association (NFPA), and the Amer-
ican Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the
local code authorities.
c) When cutting or drilling into wall or ceiling, do
not damage electrical wiring and other hidden
utilities.
d) Ducted fans must always be vented to the
outdoors.
Rating plate location
RATING PLATE
(ABOVE FILTERS)
4
|
Wolf Customer Care 800.222.7820
SITE PREPARATION
Ducting
WARNING
Use only metal ducting.
Consult a qualied HVAC professional for specic installa-
tion and ducting applications.
The hood accommodates a 6"
(152) round duct. Use only
rigid metal ducting.
A straight, short duct run is most effective and will ensure
proper performance. If the duct run exceeds 50'
(15 m), a
higher CFM blower may be required to maintain proper
airow. A remote blower installed on a short duct run may
increase the potential for noise.
Internal and in-line blowers require a roof or wall cap. Use
sheet metal screws and aluminum tape or high temperature
duct tape to seal joints between ducting sections.
The hood includes a backdraft damper. Local codes may
require the use of an additional backdraft and/or make-up
air damper. Contact your local HVAC professional for
specic requirements.
A make-up air damper is available through an authorized
Wolf dealer.
CAUTION
To reduce the risk of re and to properly exhaust air,
duct air outside. Do not vent exhaust air into spaces
within walls, ceilings, attics, crawl spaces, or garages.
CAUTION
To reduce the risk of re and electrical shock, only
install this range hood with remote blower models
rated a maximum of 3A suitable for use with solid state
speed control or internal blowers manufactured by
Wolf, “Blower—600 CFM”.
wolfappliance.com
|
5
Ducting
RECIRCULATION APPLICATION
The hood with an internal blower, can be installed in a recir-
culation application. The air discharge must be a minimum
of 40"
(1016) from every side of the hood. Refer to the illus-
tration below.
Ductwork and vent cover are not provided.
A recirculation kit, available through an authorized Wolf
dealer, is required.
40"
(
1016
)
MIN
Recirculation application
SITE PREPARATION
Filter Removal
To access the grease lters, pull down the front edge of the
bottom panel of the hood and allow it to rotate downward.
To remove the lters, refer to the illustration below.
IMPORTANT NOTE: Do not operate the ventilation hood
without the grease lters.
FILTER
Filter removal
6
|
Wolf Customer Care 800.222.7820
Installation Requirements
Install the hood 36" (914) to 84" (2134) from the bottom of the
hood to the countertop.
The hood requires a 600 CFM internal or in-line blower
assembly, or a 600 CFM or 1200 CFM remote blower
assembly, available through an authorized Wolf dealer.
Consult a qualied HVAC professional for specic installa-
tion and ducting applications.
SPECIFICATIONS
Electrical Requirements
Installation must comply with all applicable electrical codes.
Locate the electrical supply within the shaded area shown
in the illustration below. Allow a minimum 12"
(305) wire
(Romex) for connection. A separate circuit servicing only
this appliance is required.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 120 VAC, 60 Hz
Service 15 amp dedicated circuit
Rating plate location
RATING PLATE
(ABOVE FILTERS)
E
36"
(914) TO 84" (2134) BOTTOM EDGE TO COUNTERTOP
Electrical location
wolfappliance.com
|
7
Mounting Brackets
To determine the height of the adjustable mounting
brackets, subtract 5"
(127) from the support framing height
(e.g. support framing height – 5" = H).
Use the
3
/8" (10) length screws provided to secure the
brackets. Refer to the illustration below.
Ceiling Preparation
Refer to the chart and illustrations below for opening dimen-
sions and typical framing. Construct the framing using
minimum 2" x 4" lumber. Framing must be able to support a
minimum of 100 lb
(45 kg).
HOOD
W
36" Hood 34
1
/2" (873)
48" Hood 46
1
/4" (1175)
H
Bracket adjustment
12
3
/8
" (314) MIN TO
17
3
/4
" (451) MAX
Support framing (typical)
W
20"
(
508
)
Opening dimensions
SPECIFICATIONS
8
|
Wolf Customer Care 800.222.7820
INSTALLATION
BLOWER INSTALLATION
IMPORTANT NOTE: The blower must be installed and
plugged in prior to making the electrical connection to the
hood.
1 Insert the round discharge on the blower into the round
discharge on the blower box.
2 Secure the blower to the blower box with the two screws
provided with the blower. Refer to the illustration below.
3 Rotate the blower box so the 6" (152) round discharge is
properly located. Refer to the illustration below.
4 Secure the blower box to the hood with the existing
screws.
Internal blower installation
Discharge direction
Hood Installation—Internal Blower
BLOWER BOX REMOVAL
Remove the blower box from the hood by removing the four
screws. Refer to the illustration below.
Blower box removal
wolfappliance.com
|
9
Hood Installation—Internal Blower
DAMPER INSTALLATION
Place the round damper on the round discharge and secure
with duct sealing tape. Refer to the illustration below.
Damper installation
INSTALLATION
BRACKET INSTALLATION
Secure the two mounting brackets to the hood using the
four
9
/16" (14) length screws provided. Refer to the illustration
below.
Bracket installation
10
|
Wolf Customer Care 800.222.7820
Hood Installation—Internal Blower
HOOD INSTALLATION
IMPORTANT NOTE: Mounting hardware is not provided.
1 Verify the control panel on the hood is located on the
right. Refer to the illustration below.
2 Insert the hood into the opening.
3 Secure the hood to the ceiling support framing. Refer to
the illustration below.
4 Connect the ductwork to the damper, then secure with
duct sealing tape.
Hood installation
INSTALLATION
WIRING CONNECTIONS
WARNING
Before making electrical connections, make sure the
electrical power is turned off at the service panel.
1 Remove the knockout above the home supply junction
box, then insert the home electrical supply (Romex) into
the electrical box. Refer to the illustration below.
2 Secure the electrical supply to the electrical box with a
UL or C/UL approved connector (not provided).
3 Connect the green or bare ground wire to the green
grounding screw. Use appropriate wire connectors (not
provided) to connect white to white and black to black.
4 Place all wiring connections inside the electrical box and
then install the cover. Verify all wires are secure and not
pinched between the cover and electrical box.
5 Insert the plug from the control board housing into the
receptacle on the blower. Refer to the illustration below.
HOME
SUPPLY
BLOWER
RECEPTACLE
Wiring connections
Blower connection
Control panel location
wolfappliance.com
|
11
FLANGE INSTALLATION
1 Place the ange on the top of the hood.
2 Secure the ange to the hood with the
1
/4" (6) length
screws provided. Refer to the illustration below.
INSTALLATION
Hood Installation—In-Line/Remote Blower
BLOWER BOX REMOVAL
1 Remove the blower box from the hood by removing the
four screws. Refer to the illustration below.
2 Discard the blower box and screws.
Blower box removal
Flange installation
12
|
Wolf Customer Care 800.222.7820
INSTALLATION
Hood Installation—In-Line/Remote Blower
BRACKET INSTALLATION
Secure the two mounting brackets to the hood using the
four
9
/16" (14) length screws provided. Refer to the illustration
below.
HOOD INSTALLATION
IMPORTANT NOTE: Mounting hardware is not provided.
1 Verify the control panel on the hood is located on the
right. Refer to the illustration below.
2 Insert the hood into the opening.
3 Secure the hood to the ceiling support framing. Refer to
the illustration below.
4 Connect the ductwork to the damper, then secure with
duct sealing tape.
Hood installation
Bracket installation
Control panel location
wolfappliance.com
|
13
Hood Installation—In-Line/Remote Blower
WIRING CONNECTIONS
WARNING
Before making electrical connections, make sure the
electrical power is turned off at the service panel.
Home Supply:
1 Remove the knockout above the home supply junction
box, then insert the home electrical supply (Romex) into
the electrical box. Refer to the illustration below.
2 Secure the electrical supply to the electrical box with a
UL or C/UL approved connector (not provided).
3 Connect the green or bare ground wire to the green
grounding screw. Use appropriate wire connectors (not
provided) to connect white to white and black to black.
4 Place all wiring connections inside the electrical box and
then install the cover. Verify all wires are secure and not
pinched between the cover and electrical box.
In-Line/Remote Supply:
1 Remove the knockout above the in-line/remote blower
junction box, then insert the blower electrical supply
(Romex) into the electrical box.
2 Secure the electrical supply to the electrical box with a
UL or C/UL approved connector (not provided).
3 Connect the green or bare ground wire to the green
grounding screw. Use appropriate wire connectors (not
provided) to connect white to white and black to black.
4 Place all wiring connections inside the electrical box and
then install the cover. Verify all wires are secure and not
pinched between the cover and electrical box.
5 Insert the plug from the control board housing into the
receptacle on the side of the junction box.
wolfappliance.com
|
13
INSTALLATION
IN-LINE/REMOTE
BLOWER
HOME
SUPPLY
Wiring connections
14
|
Wolf Customer Care 800.222.7820
Completion
1 Install the grease lters. Refer to the illustration below.
2 Rotate the bottom cover upward and into position.
3 Turn on the electrical supply at the circuit panel and
verify operation.
Troubleshooting
IMPORTANT NOTE: If the hood does not operate properly,
follow these troubleshooting steps:
1 Verify electrical power is supplied to the hood.
2 Verify proper wiring connections.
3 If the hood does not operate properly, contact Wolf
Factory Certied Service. Do not attempt to repair the
hood. Wolf is not responsible for service required to
correct a faulty installation.
TROUBLESHOOTING