3063772_201507 7
4. Specication
Type MGK-2 390 470 550 630
Rated heating output at 80/60 °C kW 366.7 434.7 511.6 584.4
Rated heating output at 50/30 °C kW 392.0 467.1 549.3 626.6
Rated heat input kW 371.2 443.6 521.0 593.9
Low boiler output (modul.) at 80/60 °C kW 58.5 70.7 84.5 96.7
Low boiler output (modul.) at 50/30 °C kW 64.2 78.7 94.0 106.8
Low heat input (modulating) kW 59.5 73.2 86.8 98.5
Heat input modulation range % 17-100 17-100 17-100 17-100
Efciency η 80/60 at Qmax % 98.8 98.0 98.2 98.4
η 50/30 at Qmax % 105.6 105.3 105.4 105.5
η TR30 at 30 % % 107.8 108.9 108.6 107.6
Standard seasonal efciency at 40/30 °C % 109.9 110.1 110.3 110.4
at 75/60 °C
% 106.4 106.4 106.3 106.3
Overall height mm 1460 1460 1460 1460
Overall width mm
1860
(1295 in
sections)
1860
(1295 in
sections)
1860
(1295 in
sections)
1860
(1295 in
sections)
Overall depth / depth without casing mm 850 / 790 850 / 790 850 / 790 850 / 790
Flue diameter mm 250 250 250 250
Combustion air supply mm 200 200 200 200
Heating ow DN 80 PN6 80 PN6 80 PN6 80 PN6
Heating return DN 80 PN6 80 PN6 80 PN6 80 PN6
Gas connection R 2" 2" 2" 2"
Air/ue gas routing Type B23, B23P,
C33, C43,
C53, C63,
C83, C93
B23, B23P,
C33, C43,
C53, C63,
C83, C93
B23, B23P,
C33, C43,
C53, C63,
C83, C93
B23, B23P,
C33, C43,
C53, C63,
C83, C93
Gas supply details:
Natural gas E/H (H
i
= 9.5 kWh/m³ = 34.2 MJ/m³) m³/h 39.1 46.7 54.8 62.5
Natural gas LL (H
i
= 8.6 kWh/m³ = 31.0 MJ/m³) m³/h 43.2 51.6 60.6 69.1
Gas supply pressure: Natural gas E/H/LL mbar 20 20 20 20
Water content, heating water heat exchanger l 50 56 62 68
Max. permissible boiler pressure bar 6 6 6 6
Max. permissible ow temperature °C 85 85 85 85
Available gas fan draught Pa 150 150 150 150
Standby losses excess temperature
30 / 50 K
% 0.11 / 0.18 0.10 / 0.17 0.09 / 0.15 0.09 / 0.14
Flue gas temperature 80/60-50/30 at Qmax °C 65-35 65-35 65-35 65-35
Flue gas temperature 80/60-50/30 at Qmin °C 60-30 60-30 60-30 60-30
Max. ue gas volume ow
g/s 156.3 185.2 225.3 247.4
Flue gas category to DVGW G 635 G 52 G 52 G 52 G 52
Heating water pressure drop at 20 K spread mbar 120 113 126 118
Electrical connection of MCB protection V~/Hz
1~ NPE / 230 V AC / 50 Hz / 10 A/B
Alternative: 3~ PE / 400 V AC / 50 Hz / 10 A/B
Output heating circuit pump / ZHP fuse/MCB protection V~/Hz
1~ NPE / 230VAC / 50Hz / 4A
Alternative: 3~ PE / 400 V AC / 50 Hz / 4 A
Power consumption (partial load / full load) W 42 - 410 45 - 490 48 - 580 50 - 660
Standby power consumption W 11 11 11 11
IP rating IP20 IP20 IP20 IP20
Sound power to DIN EN 15036 Part 1, balanced ue dB(A) 61 66 68 68
Sound pressure level 1 m upstream of MGK-2, balanced ue
1)
dB(A) 44 49 50 50
Sound power to DIN EN 15036 Part 1, open ue dB(A) 78 82 84 84
Sound pressure level 1 m upstream of MGK-2, open ue
1)
dB(A) 60 64 65 65
Total weight (dry) kg 390 420 450 480
Amount of condensate at 40/30 °C l/h 39 46 52 59
Condensate pH value approx. 4.0 approx. 4.0 approx. 4.0 approx. 4.0
CE ID 0085CN0326 0085CN0326 0085CN0326 0085CN0326
1)
depending on the general system conditions, such as: type/version of the flue system, size and nature of the installation room