Wolf IF15-S User Manual

Page 1
lanning Information
P
Integrated Electric Fryer Module
MODEL IF15/S
odel IF15/S
M
ow profile lid
L
eep drawn pan
D
Location of rating plate
idden 2600-watt
H heating element
Illuminated electronic touch controls
Graduated control lighting
igital tempera-
D ture readout
The Wolf Model IF15/S 15" (381) integrated electric fryer module is available in the classic stainless steel finish.
Dimensions in parentheses are in millimeters unless otherwise specified.
9/07
To round out your options for the ideal kitchen, you
must have a fryer to choose from and Wolf offers a great option that the market has never seen. Dinner specialties that you never tried before will be at your fingertips when your client uses this module.
The accurate temper
ature contr customer to seal in that great flavor of the food without absorbing any unnecessary grease. In addition, the extremely deep fryer will ena portions of small items or a whole chicken.
The W
olf electric fryer module is av
stainless steel.
With Wolf’s integrated modules, you have the ultimate in customization. You can create your own design by mixing and matching the various components within this system.
ol will enable your
ou to handle large
ble y
ailable in classic
1
Page 2
lanning Information
15" (381)
OVERALL WIDTH
21"
(533)
OVERALL
DEPTH
131/2" (343)
TO DRAIN
OUTLET
71/2"
(191)
P
Integrated Electric Fryer Module
MODEL IF15/S
FEATURES
Integrated design allows for installation of multiple cooktops or modules
Stainless steel top construction with classic stainless steel finish
Hidden 2600-watt heating element
Illuminated electronic touch controls with graduated control lighting
Large 1
Three baskets included— one large and two small side by side, each with wire basket hanger
Low-profile lid
1
/4 gallon (3.8 L) capacity tub
Melt feature for shortening or lard
I
ndependent digital timer
Digital temperature readout and preheat indicator
Easy manual locking drain capability
Recommended for installation with any Wolf framed electric cooktop or the Wolf electric grill module
CSA certified for US and Canada
Two and five year residential warranty— exclusions apply; warranty information can be found on our website, wolfappliance.com
OVERALL DIMENSIONS
Unit dimensions may vary by ±
Dimensions in parentheses are in millimeters unless otherwise specified.
1
/8" (3).
2
Page 3
lanning Information
P
Integrated Electric Fryer Module
MODEL IF15/S
odel IF15/S
M
VENTILATION OPTIONS
30" (762) Cooktop hood or Pro wall or wall chimney hood or liner
36" (914) Pro island hood
For additional information, refer to the Cooktop or Pro Ventilation sections of our website, wolfappliance.com.
ACCESSORIES
Filler strip
SPECIFICATIONS
O
verall Cooktop Width 15" (381)
Overall Cooktop Height 131/2" (343)
Overall Cooktop Depth 21" (533)
Heating Element 2600 W
Minimum Cabinet Depth 223/4" (578)
M
inimum Height Clearance 13
1
/2"
(343)
Cooktop Cut-Out Width 14" (356)
Cooktop Cut-Out Depth 191/4" (489)
Electrical Supply Requirements 240/ 208 V AC, 60 Hz
15 amp cir
cuit
Conduit 4 ft (1.2 m) flexible 3-wire
Electrical Rating 2.6 kW at 240 V
1.9 kW at 208 V
Shipping Weight 30 lbs (14 kg)
Accessories are available through your Wolf dealer. To obtain local dealer information, visit the Showroom Locator section of our website, wolfappliance.com.
Special Note Module can be installed in combination
with other cooktops or modules
Specifications are subject to change without notice.
Unit dimensions may vary by ±1/8" (3).
Dimensions in parentheses are in millimeters unless otherwise specified.
3
Page 4
lanning Information
7"*m
in (178)
CUT-OUT TO
COMBUSTIBLE
M
ATERIALS
(BOTH SIDES)
14" (356)
COOKTOP CUT-OUT
WIDTH
14" (356)
C
OOKTOP CUT-OUT
WIDTH
33" (
838) RECOMMENDED CABINET WIDTH
18"
(
457)
NOTE: Application shown allows for installation of two 15" (381) modules side-by-side with 33" (838) recommended cabinet width. 18" (457) recommended cabinet width for installation of single 15" (381) cooktop or module. NOTE: Fryer module must be installed in a base cabinet with access to manual valve at base of unit to drain oil into heat resistant receptacle. *Minimum clearance from both side edges of cooktop cut-out to combustible materials up to 18" (457) above countertop. **Minimum clearance from rear edge of cooktop cut-out to combustible materials up to 18" (457) above countertop.
191/4" (489)
C
OOKTOP CUT-OUT
DEPTH
21/2"m
in
(64)
36" (
914)
STANDARD
FLOOR TO
C
OUNTERTOP
HEIGHT
13" m
ax
(330)
30" (762)
COUNTERTOP TO
C
OMBUSTIBLE MATERIALS
ABOVE COOKTOP
FRONT OF COUNTERTOP
21/2"min
(64)
191/4" (489)
COOKTOP
CUT-OUT DEPTH
75/8"
(194)
123/8"
(
314)
DRAIN OUTLET
LOCATION
E
131/2"
(343)
15"
(381)
15"
(381)
123/8"
(
314)
6"
(152)
D
RAIN OUTLET
LOCATION
2"**
(
51)
P
Integrated Electric Fryer Module
MODEL IF15/S
INSTALLATION SPECIFICATIONS
DIMENSIONS
Minimum Cabinet Depth 223/4" (578)
Cooktop Cut-Out Width 14" (356)
Cooktop Cut-Out Depth 191/4" (489)
Location of Electrical Within shaded area
See Installation Instructions shipped with unit for detailed specifications.
Dimensions in parentheses are in millimeters unless otherwise specified.
4
Page 5
lanning Information
P
Integrated Electric Fryer Module
MODEL IF15/S
INSTALLATION NOTES
Refer to the illustrations and specifications for overall dimensions, cut-out dimensions and installation specifics.
Wolf recommends using 33" (838) wide cabinets for installation of two integrated modules side by side. An 18" (457) wide cabinet is recommended for installation of a single integrated cooktop module.
IMPORTANT NOTE: Review specific installation instructions for product to product capabilities
When multiple cooktops or modules are installed side by side, refer to the countertop cut-out dimensions on page 6.
This fryer module must be installed at least 15" (381) away from any open flame cooking device. The open flame may cause ignition of oil.
This fryer module must be installed at least 15" (381) away from a module, as contact between water and hot oil may cause
burns from steam and hot oil.
Wolf steamer
IMPORTANT NOTE: Wolf does not recommend the use of downdraft ventilation with the inte­grated fryer module.
The Wolf integrated fryer module requires a separate, grounded 3-wire 240/208 V AC, 60 Hz, 15 amp service with its own circuit breaker. It has a 4' (1.2 m) flexible 3-wire conduit for connection at the electrical supply. Locate electrical within the shaded area shown in the illustration on page 4.
You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.
The integrated fryer module must be installed in a base cabinet with access to the bottom of the unit to drain the oil through a manual valve. The consumer must supply a heat resistant bucket to accept the drained oil. Refer to the illustration on page 4 for location of the drain outlet.
Refer to the installation instructions shipped with each Wolf product for detailed specifications.
This cooktop is intended for indoor use only.
A Wolf Cooktop or Pro ventilation hood is recommended. When installing a ventilation hood, refer to the specific requirements of the hood for the minimum dimension to countertop. Also refer to the ventilation recommendation charts in the cooktop or Pro ventilation sections of our website, wolfappliance.com.
Dimensions in parentheses are in millimeters unless otherwise specified.
5
Page 6
lanning Information
21/2"min
(64)
FRONT OF COUNTERTOP
191/4"
(489)
CUT-OUT
DEPTH
291/4" (743)
TWO MODULES WIDTH
441/2" (1130) THREE MODULES WIDTH OR
441/4" (1124) 30" COOKTOP AND ONE MODULE
593/4" (1518) FOUR MODULES WIDTH OR
591/2" (1511) 30" COOKTOP AND TWO MODULES OR
501/4" (1276) 36" COOKTOP AND ONE MODULE
14"
(356)
CUT-OUT
WIDTH
P
Integrated Electric Fryer Module
MODEL IF15/S
MULTIPLE COOKTOP INSTALLATION
With Wolf's integrated modules, you have the ultimate in customization. You can create your own design by mixing and matching the various components within this system. And when you couple these modules with other cooktops within the Wolf inventory you and your client will truly understand freedom of choice.
Some Wolf integrated modules can be installed together or with a 30" (762) or 36" (914) cooktop. When multiple units are installed side by side, the cut-out dimensions that are shown in the illustration are derived by adding 1
1
/4" (32) additional space for each additional unit, to give you your total cut-out width. Refer to the illus­tration below for countertop cut-out dimensions for installation of multiple cooktop units.
When two or more cooktops or modules are installed together, an accessory filler strip is recommended. Refer to Accessories on page 3.
IMPORTANT NOTE: When multiple cooktops and/ or modules are installed side by side, each unit must have its own separate recommended electrical circuit. When multiple gas cooktops and/ or modules are installed next to one another, they can receive their gas supply from a common line. However, each unit must have its own regulator installed between the mainline and the cooktop or module.
IMPORTANT NOTE: Review specifications for each specific integrated module for installation requirements and limitations. Refer to the integrated modules section of our website, wolfappliance.com.
Countertop cut-out dimensions for installation of multiple cooktop units.
Dimensions in parentheses are in millimeters unless otherwise specified.
6