Features and specications are subject to change at any
time without notice.
Throughout this guide, dimensions may vary by ± 3 mm.
MODULE COOKTOPS
Module Cooktops
Wolf 38 cm modules have been redesigned to match the
updated lines of Sub-Zero and Wolf. Controls, grates and
trim allow them to integrate perfectly with their larger counterparts and deliver equal performance. Combine modules à
la carte-style to create a custom cooktop, or add specialty
functions alongside an existing cooktop. Full-size cooktops
including ICBCI243TF/S, ICBCI304TF/S, and ICBCI365TF/S
feature the same brushed stainless frame, making them
ideal for pairing with modules.
MODULE COOKTOPS
MODULE COOKTOPS
ICBCI152TF/S
INDUCTION
ICBCG152TF/S
GAS
ICBSM15TF/S
STEAMER
ICBMM15TF/S
MULTIFUNCTION
ICBGM15TF/S
GRILL
ICBTM15TF/S
TEPPANYAKI
| English
3
MODULE COOKTOPS
Module Cooktops
INDUCTIONGRILLTEPPANYAKI
533
mm
381 mm
32
mm
CONDUIT
22
mm
51 mm
GAS
533
mm
STEAMER
533
mm
381
mm
222
mm
DRAIN
OUTLET
102
mm
22
mm
MULTIFUNCTION
533
mm
32
mm
381
mm
22
mm
533
mm
152
mm
381
mm
22 mm
533
mm
51 mm
MODULE COOKTOPS
381
mm
22 mm
102 mm
381
mm
22 mm
127 mm
ubzero-wolf.com.au | 4
s
MODULE COOKTOPS
Planning Information
IMPORTANT NOTE: Wolf does not recommend the use of
downdraft ventilation with the steamer or grill modules.
A minimum 51 mm is required from the bottom of the
module to combustible materials. For the teppanyaki
module, a minimum 22 mm is required from the bottom of
the unit to any material.
Refer to illustrations on the following pages for installation of
modules.
MODULE COOKTOPS
When multiple modules are installed side by side, refer to
the chart and illustration below for typical congurations.
The cut-out dimensions provided will accommodate the use
of an optional ller strip if desired.
CUT- OUT
DEPTH
W*
COUNTERTOP CUT-OUT
(2) 38 cm Modules737 mm
(3) 38 cm Modules1118 mm
(4) 38 cm Modules1505 mm
(5) 38 cm Modules1886 mm
(6) 38 cm Modules2267 mm
*Dimensions apply to ICBCI152TF/S, ICBCE152TF/S, ICBCG152TF/S,
ICBSM15TF/S, ICBGM15TF/S, ICBTM15TF/S and ICBMM15TF/S.
W*
CUT-OUT
WIDTH
64 mm*
MIN
64 mm*
MIN
495 mm*
| English
5
FRONT OF COUNTERTOP
Countertop cut-out.
MODULE COOKTOPS
Planning Information
ELECTRICAL
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
Locate the electrical supply as shown in the illustrations on
the following pages. A separate circuit, servicing only this
appliance is required.
The induction cooktop is supplied with a single phase and
3-phase convertible power inlet box.
When multiple cooktops or modules are installed side by
side, each must have its own separate electrical supply.
ELECTRICAL REQUIREMENTS
INDUCTION MODULE
Single Phase220-240 VAC, 50/60 Hz
3-Phase380-415 V AC 50 Hz
Total Amps16
ELECTRIC MODULES
Electrical Supply220-240 VAC, 50/60 Hz
Steamer, Teppanyaki2700 W
Grill2800 W
GAS MODULES
Electrical Supply
Service
Receptacle
Power Cord1.8 m
0.2 A
220-240 VAC; 50/60 Hz
standard 10 A power point
3-prong grounding-type
GAS SUPPLY
Installation must conform with all applicable gas codes.
For gas modules, a gas supply line of 19 mm rigid pipe is advised to be provided to the module. If local codes permit,
a certi-fied, .9 m long, 13 mm or 19 mm ID flexible
appliance connector is recommended to connect the units
ISO 7/1-14 male inlet to the gas supply line.
When multiple gas cooktops or modules are installed side
by side, they can receive their gas supply from a common
line. However, each unit must have its own regulator
installed between the mainline and the cooktop or module.
Wolf natural gas cooktops will function up to 3124 m in altitude without adjustment and LP gas cooktops will function
up to 2621 m.
GAS REQUIREMENTS
NATURAL GAS
Supply Pressure
LP GAS
Supply Pressure
1 Kpa
2.75 Kpa
MODULE COOKTOPS
DRAIN OUTLET
The steamer module requires a method for draining hot
water. Options include connecting a drain hose from the
16 mm outlet tied into an existing drain, a separate drain
with freefall or placing a heat-resistant receptacle under the
drain outlet.
ubzero-wolf.com.au | 6
s
SIDE
NO
combus
MODULE COOKTOPS
Induction Module
STANDARD INSTALLATION
64 mm
MODULE COOKTOPS
330
mm
min 457
mm
COUNTERTOP CUT-OUT
min 650
51
mm
356
mm
mm
E
495
mm
64 mm
914 mm
FLOOR TO
COUNTERTOP
VIEW
TE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
tible materials cannot be located within this area.
| English
7
FRONT VIEW
SIDE
MODULE COOKTOPS
Steamer Module
STANDARD INSTALLATION
64 mm
MIN
330
mm
200
mm
min 457
mm
356
mm
COUNTERTOP CUT-OUT
min 650
mm
178
mm
152
mm
314
mm
DRAIN
OUTLET
E
495
mm
64 mm
MIN
MODULE COOKTOPS
VIEW
NOTE: Shaded area above countertop indicates minimum c
combustible materials cannot be located within this area.
Drain location from front of cutout
FRONT VIEW
learance to combustible surfaces,
ubzero-wolf.com.au | 8
s
MODULE COOKTOPS
SIDE
NO
combus
Grill | Teppanyaki Module
STANDARD INSTALLATION
64 mm
MIN
MODULE COOKTOPS
330
mm
min 457
mm
356
mm
COUNTERTOP CUT-OUT
min650
mm
178
mm
E
495
mm
64 mm
MIN
VIEW
TE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
tible materials cannot be located within this area.
| English
9
FRONT VIEW
MODULE COOKTOPS
SIDE
Gas | Multifunction Module
STANDARD INSTALLATION
64 mm
MIN
330
mm
min 457
mm
356
mm
COUNTERTOP CUT-OUT
min 650
mm
178
mm
EG
495
mm
64 mm MIN
MODULE COOKTOPS
VIEW
NOTE: The rangehood fitted above the cooktop must be installed according to the installation
instructions for the rangehoods.
A minimum clearance of 650mm from the top of the burner port to a grease filter/range hood/
combustible surface and 750mm to an Exhaust fan.
FRONT VIEW
bzero-wolf.com.au | 10
su
Wolf Appliance International Limited Warranty
FOR RESIDENTIAL USE
FULL TWO YEAR WARRANTY*
For two years from the date of original installation, this Wolf Appliance product warranty covers all parts
and labor to repair or replace, under normal residential use, any part of the product that proves to be
defective in materials or workmanship. All service provided by Wolf Appliance under the above warranty
must be performed by Wolf factory certied service, unless otherwise specied by Wolf Appliance, Inc.
Service will be provided during normal business hours.
LIMITED THIRD THROUGH FIFTH YEAR WARRANTY
For ve years from the date of original installation, Wolf Appliance will repair or replace the following parts
that prove to be defective in materials or workmanship: gas burners (excluding appearance), electric
heating elements, blower motors (ventilation hoods), electronic control boards, magnetron tubes and
induction generators. The part(s) will be repaired or replaced, free of charge, with the owner paying for
all other costs including labor. All service provided by Wolf Appliance under the above warranty must be
performed by Wolf factory certied service, unless otherwise specied by Wolf Appliance, Inc. Service will
be provided during normal business hours.
For more information regarding your Wolf product warranty, contact your authorized Wolf dealer. Warranties must comply to all country, state, city, local and or ordinance.
*Stainless steel (doors, panels, handles, product frames and interior surfaces) are covered by a limited