WOLF ICBCG152TF/S, ICBCI152TF/S Quick Guide

MODULE COOKTOP DESIGN GUIDE
ICB REVISED 4 / 2018
TABLE OF CONTENTS
3 MODULES
Features and specications are subject to change at any time without notice.
Throughout this guide, dimensions may vary by ± 3 mm.
MODULE COOKTOPS
Module Cooktops
Wolf 38 cm modules have been redesigned to match the updated lines of Sub-Zero and Wolf. Controls, grates and trim allow them to integrate perfectly with their larger coun­terparts and deliver equal performance. Combine modules à la carte-style to create a custom cooktop, or add specialty functions alongside an existing cooktop. Full-size cooktops including ICBCI243TF/S, ICBCI304TF/S, and ICBCI365TF/S feature the same brushed stainless frame, making them ideal for pairing with modules.
MODULE COOKTOPS
MODULE COOKTOPS
ICBCI152TF/S INDUCTION
ICBCG152TF/S GAS
ICBSM15TF/S STEAMER
ICBMM15TF/S MULTIFUNCTION
ICBGM15TF/S GRILL
ICBTM15TF/S TEPPANYAKI
| English
3
MODULE COOKTOPS
Module Cooktops
INDUCTION GRILL TEPPANYAKI
533 mm
381 mm
32
mm
CONDUIT
22
mm
51 mm
GAS
533
mm
STEAMER
533 mm
381 mm
222 mm
DRAIN
OUTLET
102 mm
22
mm
MULTIFUNCTION
533 mm
32
mm
381 mm
22
mm
533 mm
152 mm
381 mm
22 mm
533 mm
51 mm
MODULE COOKTOPS
381
mm
22 mm
102 mm
381 mm
22 mm
127 mm
ubzero-wolf.com.au | 4
s
MODULE COOKTOPS
Planning Information
IMPORTANT NOTE: Wolf does not recommend the use of
downdraft ventilation with the steamer or grill modules.
A minimum 51 mm is required from the bottom of the module to combustible materials. For the teppanyaki module, a minimum 22 mm is required from the bottom of the unit to any material.
Refer to illustrations on the following pages for installation of modules.
MODULE COOKTOPS
When multiple modules are installed side by side, refer to the chart and illustration below for typical congurations. The cut-out dimensions provided will accommodate the use of an optional ller strip if desired.
CUT- OUT
DEPTH
W*
COUNTERTOP CUT-OUT
(2) 38 cm Modules 737 mm
(3) 38 cm Modules 1118 mm
(4) 38 cm Modules 1505 mm
(5) 38 cm Modules 1886 mm
(6) 38 cm Modules 2267 mm
*Dimensions apply to ICBCI152TF/S, ICBCE152TF/S, ICBCG152TF/S, ICBSM15TF/S, ICBGM15TF/S, ICBTM15TF/S and ICBMM15TF/S.
W*
CUT-OUT
WIDTH
64 mm*
MIN
64 mm*
MIN
495 mm*
| English
5
FRONT OF COUNTERTOP
Countertop cut-out.
MODULE COOKTOPS
Planning Information
ELECTRICAL
Installation must comply with all applicable electrical codes and be properly grounded (earthed).
Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit, servicing only this appliance is required.
The induction cooktop is supplied with a single phase and 3-phase convertible power inlet box.
When multiple cooktops or modules are installed side by side, each must have its own separate electrical supply.
ELECTRICAL REQUIREMENTS
INDUCTION MODULE
Single Phase 220-240 VAC, 50/60 Hz 3-Phase 380-415 V AC 50 Hz Total Amps 16
ELECTRIC MODULES
Electrical Supply 220-240 VAC, 50/60 Hz Steamer, Teppanyaki 2700 W Grill 2800 W
GAS MODULES
Electrical Supply Service Receptacle Power Cord 1.8 m
0.2 A
220-240 VAC; 50/60 Hz
standard 10 A power point
3-prong grounding-type
GAS SUPPLY
Installation must conform with all applicable gas codes.
For gas modules, a gas supply line of 19 mm rigid pipe is advised to be provided to the module. If local codes permit, a certi-fied, .9 m long, 13 mm or 19 mm ID flexible appliance connector is recommended to connect the units ISO 7/1-14 male inlet to the gas supply line.
When multiple gas cooktops or modules are installed side by side, they can receive their gas supply from a common line. However, each unit must have its own regulator installed between the mainline and the cooktop or module.
Wolf natural gas cooktops will function up to 3124 m in alti­tude without adjustment and LP gas cooktops will function up to 2621 m.
GAS REQUIREMENTS
NATURAL GAS
Supply Pressure
LP GAS
Supply Pressure
1 Kpa
2.75 Kpa
MODULE COOKTOPS
DRAIN OUTLET
The steamer module requires a method for draining hot water. Options include connecting a drain hose from the 16 mm outlet tied into an existing drain, a separate drain with freefall or placing a heat-resistant receptacle under the drain outlet.
ubzero-wolf.com.au | 6
s
SIDE
NO combus
MODULE COOKTOPS
Induction Module
STANDARD INSTALLATION
64 mm
MODULE COOKTOPS
330 mm
min 457
mm
COUNTERTOP CUT-OUT
min 650
51
mm
356 mm
mm
E
495 mm
64 mm
914 mm
FLOOR TO
COUNTERTOP
VIEW
TE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
tible materials cannot be located within this area.
| English
7
FRONT VIEW
SIDE
MODULE COOKTOPS
Steamer Module
STANDARD INSTALLATION
64 mm
MIN
330 mm
200 mm
min 457
mm
356 mm
COUNTERTOP CUT-OUT
min 650
mm
178 mm
152 mm
314 mm
DRAIN
OUTLET
E
495 mm
64 mm
MIN
MODULE COOKTOPS
VIEW
NOTE: Shaded area above countertop indicates minimum c combustible materials cannot be located within this area.
Drain location from front of cutout
FRONT VIEW
learance to combustible surfaces,
ubzero-wolf.com.au | 8
s
MODULE COOKTOPS
SIDE
NO combus
Grill | Teppanyaki Module
STANDARD INSTALLATION
64 mm
MIN
MODULE COOKTOPS
330 mm
min 457
mm
356 mm
COUNTERTOP CUT-OUT
min650
mm
178 mm
E
495 mm
64 mm
MIN
VIEW
TE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
tible materials cannot be located within this area.
| English
9
FRONT VIEW
MODULE COOKTOPS
SIDE
Gas | Multifunction Module
STANDARD INSTALLATION
64 mm
MIN
330 mm
min 457
mm
356 mm
COUNTERTOP CUT-OUT
min 650
mm
178 mm
E G
495 mm
64 mm MIN
MODULE COOKTOPS
VIEW
NOTE: The rangehood fitted above the cooktop must be installed according to the installation instructions for the rangehoods. A minimum clearance of 650mm from the top of the burner port to a grease filter/range hood/ combustible surface and 750mm to an Exhaust fan.
FRONT VIEW
bzero-wolf.com.au | 10
su
Wolf Appliance International Limited Warranty
FOR RESIDENTIAL USE
FULL TWO YEAR WARRANTY*
For two years from the date of original installation, this Wolf Appliance product warranty covers all parts and labor to repair or replace, under normal residential use, any part of the product that proves to be defective in materials or workmanship. All service provided by Wolf Appliance under the above warranty must be performed by Wolf factory certied service, unless otherwise specied by Wolf Appliance, Inc. Service will be provided during normal business hours.
LIMITED THIRD THROUGH FIFTH YEAR WARRANTY
For ve years from the date of original installation, Wolf Appliance will repair or replace the following parts that prove to be defective in materials or workmanship: gas burners (excluding appearance), electric heating elements, blower motors (ventilation hoods), electronic control boards, magnetron tubes and induction generators. The part(s) will be repaired or replaced, free of charge, with the owner paying for all other costs including labor. All service provided by Wolf Appliance under the above warranty must be performed by Wolf factory certied service, unless otherwise specied by Wolf Appliance, Inc. Service will be provided during normal business hours.
For more information regarding your Wolf product warranty, contact your authorized Wolf dealer. Warran­ties must comply to all country, state, city, local and or ordinance.
*Stainless steel (doors, panels, handles, product frames and interior surfaces) are covered by a limited 60-day parts and labor warranty for cosmetic defects.
WOLFAPPLIANCE.COM
Loading...