Wolf Do30f/s, Do30u/s, So30f/s, So30u/s, So36u/s Installation Guide

Page 1
INSTALLATION GUIDE
L Series Built-In Ovens
Page 2
Contents
Important Note
Wolf L Series Built-In Ovens . . . . . . . . . . . . . . . . . . . . . 3
L Series Oven Specifications . . . . . . . . . . . . . . . . . . . . 4
L Series Oven Installation . . . . . . . . . . . . . . . . . . . . . . . 8
Service Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Features and specifications are subject to change at any time without notice. Visit our website, wolfappliance.com for the most up-to-date information.
IMPORTANT NOTE: Throughout this guide, dimensions in parentheses are millimeters unless otherwise specified.
o ensure the safe and efficient use of Wolf equipment,
T please take note of the following types of highlighted information throughout this guide:
IMPORTANT NOTE highlights information that is especially important.
CAUTION signals a situation where minor injury or product damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or death if precautions are not followed.
Page 3
Wolf L Series Built-In Ovens 3
wolfappliance.com/specs
L Series Oven Installation
IMPORTANT NOTE: T
his installation must be completed by a qualified installer or Wolf authorized service center technician.
Read this entire installation guide prior to installation and save for the local inspector’s reference. The homeowner should keep this installation guide for future reference.
Any questions or problems regarding installation of the L series oven should be directed to your authorized Wolf dealer or Wolf Appliance, Inc. at 800-332-9513, or visit our website at wolfappliance.com.
IMPORTANT NOTE: This appliance must be installed in
accordance with National Electrical Codes, as well as all state, municipal and local codes. The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse. The proper voltage, frequency, and amperage ratings are listed on the product rating plate.
Record the model and serial numbers before installing the L series oven. Both numbers are listed on the product rating plate located below the control panel. The oven door must be open to view the rating plate. Refer to the illustration below.
olf L Series Oven
W
Model Number
Serial Number
Location of rating plate.
RATING
PLATE
Page 4
L Series Oven Specifications 4
24" (610)
BEHIND FRAME
271/2"
(699)
283/16"
(
716)
28"
(711)
297/8"
(759)
2
4"
(610)
CONDUIT
C
HANNEL
OPEN OVEN DOOR
T
OP VIEW
3
"
(76)
203/4"
(527)
11/4"
(32)
17/8"
(48)
17/8"
(48)
R
IGHT SIDE VIEW
2
6
1
/16"
(662)
I
NSIDE
S
IDE TRIM
50"
(1270)
297/8"
(759)
24" (610)
BEHIND FRAME
24"
(610)
OPEN OVEN DOOR
CONDUIT CHANNEL
TOP VIEW
283/16"
(716)
28"
(711)
3"
(76)
203/4"
(527)
11/4"
(32)
17/8"
(48)
17/8"
(48)
RIGHT SIDE VIEW
481/2"
(1232)
INSIDE
SIDE TRIM
Overall Dimensions
30" (762) L SERIES SINGLE OVEN
odel SO30U/S shown
M
30" (762) L SERIES DOUBLE OVEN
Model DO30U/S shown
Page 5
L Series Oven Specifications 5
24" (610)
BEHIND FRAME
243/8"
(
619)
3
5
5
/8"
(
905)
24"
(610)
23" (584)
I
NSIDE
S
IDE TRIM
CONDUIT
CHANNEL
O
PEN OVEN DOOR
T
OP VIEW
341/8"
(867)
33
1
1
/16"
(870)
3"
(76)
173/4"
(451)
11/4"
(
32)
17/8"
(48)
17/8"
(48)
R
IGHT SIDE VIEW
wolfappliance.com/specs
Overall Dimensions
36" (914) L SERIES SINGLE OVEN
odel SO36U/S shown
M
Page 6
L Series Oven Specifications 6
L Series Built-In Ovens
or ease of installation, Wolf recommends using 33" (838)
F wide cabinets with 30" (762) ovens and 39" (991) wide cabinets with the 36" (914) L series oven. The installation opening must have a flat, level base platform to support the oven. Single ovens require a minimum base support of 250 lbs (113 kg). The double oven requires a minimum base support of 400 lbs (181 kg).
IMPORTANT NOTE: A minimum 24" (610) of usable
cabinet depth is required or the back panel of the cabinet may need to be removed for proper installation. The elec­trical box must be flush with the back panel of the cabinet.
The L series oven is installed by inserting into cabinetry from the front. The oven has a face trim on all four sides and will overlap stiles and rails. The trim overlaps on the top,
1
/8" (3) on the bottom and3/4" (19) on each
3
/16" (5)
side.
COMBINATION INSTALLATIONS
Wolf built-in ovens are designed and agency approved for installation with Wolf cooktops, microwaves and warming drawers only. The nominal width of the built-in oven should match the nominal width of the cooktop. A built-in oven cannot be installed below a Wolf rangetop.
For typical combination installations, refer to the illustra­tions on pages 8–10.
A single oven may be installed next to another L series single oven. You must allow for a 2
1
/2" (64) space between the oven rough openings. Also, a separate inner wall is required for each oven between openings.
Page 7
L Series Oven Specifications 7
wolfappliance.com/specs
Electrical Requirements
IMPORTANT NOTE: U
than 24" (610) for a standard installation or 25" (635) for a flush inset installation, it is recommended that the electri­cal supply for the oven be placed in an adjacent cabinet within reach of the conduit. Choose the electrical location shown in the illustrations on the following pages that best suits your installation.
L SERIES SINGLE OVENS
Power supply: 240 /208 V AC, 60 Hz, 30 amp service.
Maximum connected load: 5.1 kW at 240 V AC,
3.8 kW at 208 V AC with minimum 30 amp service.
Total amps: 21 amps.
Minimum supply wire size: L1, L2 and ground–10 AWG.
L SERIES DOUBLE OVEN
Power supply: 240 /208 V AC, 60 Hz, 50 amp service.
Maximum connected load: 8.9 kW at 240 V AC,
6.7 kW at 208 V AC with minimum 50 amp service.
Total amps: 37 amps.
Minimum supply wire size: L1, L2 and ground–10 AWG.
IMPORTANT NOTE: You must follow all National Electrical
Code regulations. In addition, be aware of local codes and ordinances when installing your service.
nless you are using cabinets deeper
he L series oven is provided with a conduit consisting of
T two insulated hot lead conductors, one insulated neutral conductor, and one uninsulated ground conductor. The wiring diagram covering the control circuit is located on the top of the L series oven in a sealed plastic bag.
UL installations: Attach the conductors to the residence wiring in accordance with National Electrical Codes and all state, municipal and local codes.
CSA installations: Attach the conductors to the electrical box provided. Then connect the residence wiring to the electrical box in accordance with all national, provincial and local codes.
The complete appliance must be properly grounded at all times when electrical power is applied.
Grounding through the neutral conductor is prohibited for new branch-circuit installations (1996 NEC); mobile homes and recreational vehicles, or where local codes prohibit grounding through the neutral conductor.
If aluminum house supply wiring is utilized, splice the appliance copper wire to the aluminum house wiring using special connectors design and agency certified for joining copper and aluminum. Follow the connector manufacturer's recommended procedure carefully. Improper connection can result in a fire hazard.
Page 8
L Series Oven Installation 8
D
IMENSION WILL VARY*
43/4" (
121)
TYPICAL*
36" (914)
F
LOOR TO
COUNTERTOP
*Dimension must accommodate height of oven trim.
NOTE: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit.
E
2
8
1
/2" (
724)
O
PENING WIDTH
273/16"
(
691)
O
PENING
HEIGHT
24" (
610) min
OPENING DEPTH
E
5
"
(127)
4
"
(102)
F
RONT VIEWSIDE VIEW
36" (914)
FLOOR TO
COUNTERTOP
E
341/2" (876)
OPENING WIDTH
241/16"
(611)
OPENING
HEIGHT
E
5"
(127)
4"
(102)
73/4" (197)
TYPICAL*
DIMENSION WILL VARY*
24" (610) min
OPENING DEPTH
*Dimension must accommodate height of oven trim.
NOTE: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit.
FRONT VIEWSIDE VIEW
30" (762) L Series Single Oven
STANDARD INSTALLATION
36" (914) L Series Single Oven
STANDARD INSTALLATION
Page 9
L Series Oven Installation 9
67" (1702)
TYPICAL*
495/8"
(1260)
O
PENING
H
EIGHT
E
E
E
281/2" (724)
OPENING WIDTH
E
5"
(127)
4"
(102)
24" (610) min
OPENING DEPTH
*Dimension must accommodate height of oven trim.
NOTE: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit.
FRONT VIEWSIDE VIEW
wolfappliance.com/specs
30" (762) L Series Double Oven
STANDARD INSTALLATION
Page 10
L Series Oven Installation 10
24" (
610) min
O
PENING DEPTH
*Platform must suppor t 250 lbs (113 kg).
NOTE: Location of electrical supply within oven opening may require additional cabinet depth.
FRONT VIEWSIDE VIEW
285/8" (727)
WARMING DRAWER
OPENING WIDTH
281/2" (724)
O
VEN OPENING WIDTH
E
E
MICROWAVE
OPENING
273/16"
(
691)
11/2" (38)
min
91/8" (232)
237/8" (606) min
3
/4" (19)
min
PLATFORM*
E
E
5"
(127)
4"
(102)
30" (762) L Series Single Oven
STANDARD INSTALLATION WITH MICROWAVE AND WARMING DRAWER
Page 11
L Series Oven Installation 11
HINGE
RETAINER
PLATE
UPPER
MOUNTING
SCREW
HINGE PIN
wolfappliance.com/specs
Install the Oven
IMPORTANT NOTE: B
efore moving the oven, protect any
finished flooring to avoid damage to the floor.
Move the oven into position near the installation opening. Remove and discard packing materials. Remove the box containing oven components found in each oven cavity.
The oven is very heavy—use caution when lifting. Do not lift the oven by the door handle. This will damage the oven door and hinges.
To reduce the weight of the oven, it may be necessary to remove the oven door. If so, a pin will need to be inserted into the spring-loaded hinge assembly to prevent it from snapping closed. For each oven door, only one hinge arm is spring loaded, requiring use of the hinge pin. The hinge pin can be found taped to the inside of the oven door. It will need to be inserted through a hole in the left hinge arm (facing the oven).
IMPORTANT NOTE: Door removal should be done only
by a qualified service technician or installer. Door removal and reinstallation may cause damage to the porcelain oven interior.
OVEN DOOR REMOVAL
1) Open the oven door. Remove both upper and lower
mounting screws of the hinge retainer plate. The oven gasket may have to be moved slightly to access the bottom screw.
2) Move the hinge retainer plate forward slightly. It will
remain on the hinge assembly after the mounting screws have been removed.
3) Insert the door hinge pin through the hole in the left
hinge arm. Refer to the illustration below.
4) Carefully close the oven door to about a 60° angle from
horizontal and lift the door away from the oven. A slight rocking motion may be required for removal.
Failure to insert the hinge pin in the hinge arm will cause damage to the oven.
Oven door hinge.
Page 12
L Series Oven Installation 12
Install the Oven
ELECTRICAL CONNECTIONS
Verify that power is disconnected from the electrical box before proceeding.
With the oven positioned directly in front of the installation opening, feed the conduit through the opening in the cabinet platform (if applicable). Depending on local codes, connect the oven to the electrical supply following steps for either a three-wire or four-wire electrical system.
THREE-WIRE ELECTRICAL SYSTEM
1) Where local codes permit, connect the ground appli-
ance wire to the neutral (white) supply wire.
2) Connect the ground and white appliance wires to the
neutral (white) supply wire in the electrical box.
3) Connect the black appliance wire to the black (L1)
power supply wire in the electrical box.
4) Connect the red appliance wire to the red (L2) power
supply wire in the electrical box.
FOUR-WIRE ELECTRICAL SYSTEM
1) Separate the ground and white appliance wires.
2) Connect the white appliance wire to the neutral (white)
supply wire in the electrical box.
3) Connect the black appliance wire to the black (L1)
power supply wire in the electrical box.
4) Connect the red appliance wire to the red (L2) power
supply wire in the electrical box.
5) Connect the ground appliance wire to the green/
ground house grounding wire in the electrical box.
Page 13
L Series Oven Installation 13
wolfappliance.com/specs
Install the Oven
POSITION THE OVEN
Carefully lift the oven up to the opening. Resting the oven on the cabinet base platform, slide the oven into the opening until it is approximately 6" (152) from full insertion. Make sure the conduit slides through the opening in the platform as the oven is moved into place.
IMPORTANT NOTE: The conduit must fit into the recessed
area along the right rear edge of the oven. Make sure it is not trapped between the oven and cabinet wall.
IMPORTANT NOTE: To avoid interference, a 90° door stop
may be required for any appliance or cabinet door installed next to an L series oven with tubular handle.
Do not block the exhaust vent located at the bottom of the oven. It must remain clear for proper ventilation.
MOUNT OVEN TO CABINETRY
Once the oven is fully inserted into the opening, locate the mounting holes on the oven side trim. There are four mounting holes for a single oven and six for a double oven. Refer to the illustration below. Use a
1
/16" drill bit to drill pilot holes into the cabinet. Using the wood screws provided, secure the oven to the cabinet.
Failure to install the mounting screws may cause the oven to tip forward during use.
Location of mounting holes.
Page 14
L Series Oven Installation 14
Verify Oven Operation
npack the box containing the oven components found in
U each oven cavity. Install the oven rack guides onto the shoulder screws located on the interior side walls of the oven. Slide the oven racks onto the rack guides and place the broiler pan in the oven.
Prior to operating the oven, be sure to read the entire use & care guide included with the oven for important safety, service and warranty information.
Turn on the electrical supply to the oven. Set the time of day by pressing the CLOCK touch pad, input the time by using the number pads, then touch ENTER.
Select any of the ten cooking modes on the control panel. Verify that the oven is coming up to temperature. For the double oven, be sure to verify operation of both ovens.
IMPORTANT NOTE: A small amount of smoke and odor
may be noticed during the initial break-in period. Refer to the L series built-in ovens use & care guide for additional information.
Troubleshooting
IMPORTANT NOTE: I
properly, follow these troubleshooting steps:
Verify that power is being supplied to the oven.
Check the electrical connections to ensure that the
installation has been completed correctly.
Refer to the troubleshooting guide in the L series
built-in ovens use & care guide.
If the oven still does not work, contact a Wolf author-
ized service center. Do not attempt to repair the oven yourself. Wolf is not responsible for service required to correct a faulty installation.
f the L series oven does not operate
Page 15
Service Information 15
wolfappliance.com/specs
Service Information
f service is necessary, maintain the quality built into your
I L series oven by calling a Wolf authorized service center.
To obtain the name and number of a Wolf authorized service center, check the contact & support section of our website, wolfappliance.com or call Wolf customer service at 800-332-9513.
When calling for service, you will need the model and serial number of the L series oven. Both numbers are listed on the product rating plate located below the control panel. The oven door must be open to view the rating plate. Refer to the illustration.
Location of rating plate.
ATING
R
LATE
P
The information and images in this guide are the copyright property of Wolf Appliance, Inc. Neither this guide nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Wolf Appliance, Inc. © Wolf Appliance, Inc. all rights reserved.
Page 16
WO LF AP PLIAN CE, IN C. P. O . BOX 4 4848 MADIS ON, W I 5374 4 WOLFAPPLI ANCE. COM 80 0.332 .9513
811 577 RE V-B 1/ 2010
Loading...