www.basler.com
+1 618.654.2341 (USA)
info@basler.com
Model
Part Number
AVC63-4A
9285800102
INTRODUCTION
AVC63-4A voltage regulators are designed for use with
50/60 hertz brushless generators. Regulator features
include frequency compensation, overexcitation shutdown,
a solid-state buildup circuit, and electromagnetic
interference (EMI) filtering.
ELECTRICAL SPECIFICATIONS
DC Output Power Ratings
Continuous: 4 Adc at 63 Vdc (252 W)
One-Minute Forcing: 6 Adc at 90 Vdc (540 W)
10-Second Forcing: 9 Adc at 134 Vdc (1,206 W)
Exciter Field DC Resistance Range
15 to 100 Ω
AC Power Input
Operating Range: 95 to 139 Vac, ±10%, single-
phase, 50/60 Hz
Burden: 450 VA
Sensing Input Operating Range
95 to 139 Vac, ±10% or 190 to 277 Vac, ±10%, singlephase, 50/60 Hz
Regulation Accuracy
Better than ±1.0%, no-load to full-load
Response Time
Less than 1.5 cycles for ±5% change in sensing voltage
EMI Suppression
Equipped with internal EMI filter
Overexcitation Shutdown
Field voltage shuts down after a time delay if exciter field
voltage rises above the normal operating range. See
Operating Features, Overexcitation Shutdown.
Voltage Buildup
Regulator has internal provisions for automatic voltage
buildup from residual generator voltage as low as 6 Vac.
Power Dissipation
15 W maximum
PHYSICAL SPECIFICATIONS
Terminations
Quarter-inch, quick-connect terminals accept Amp 1547183 (positive-lock receptacle) or Amp 154719-1 (nylon
receptacle).
Temperature
Operating Range: –40 to 60°C (–40 to 140°F)
Storage Range: –40 to 85°C (–40 to 185°F)
Vibration
Withstands 1.2 G at 5 to 26 Hz, 0.036” double amplitude at
27 to 52 Hz, and 5G at 53 to 1,000 Hz. Withstands up to 20
G in each of three mutually perpendicular axes.
Weight
283 g (10 oz) net
Dimensions
See Figure 1 for AVC63-4A dimensions.
OPERATING FEATURES
Corner Frequency Selection and Adjustment
The AVC63-4A corner frequency setting is factory-preset at
55 hertz for use with 60 hertz systems. For use with 50
hertz systems, a 45 hertz corner frequency setting is
achieved by connecting a jumper across terminals HZ1 and
HZ2.
The corner frequency is adjusted by the AVC63-4A UF ADJ
control. Clockwise rotation raises the corner frequency
(shifts the curve to the right). To adjust corner frequency:
1. Adjust the UF ADJ control fully counterclockwise.
2. Start and set the generator at its rated voltage.
3. Adjust the generator frequency to the desired
kneepoint frequency.
4. Slowly adjust the UF ADJ control clockwise until the
generator voltage just begins to decrease.
Figure 2 illustrates the AVC63-4A frequency compensation
curves.
Overexcitation Shutdown
If the exciter field voltage rises above the normal operating
range, the overexcitation shutdown function removes the
AVC63-4A output power after a time delay that is inversely
proportional to the magnitude of the overvoltage detected.
The time characteristic for this function is illustrated in
Figure 3.
After output power is removed, the regulator can be reset
by decreasing the input voltage below 6 Vac for a minimum
of 2 seconds. This can be accomplished by stopping the
prime mover or interrupting the regulator input with a reset
switch.
Stability Adjustment
The response rate of the generator output voltage to a
change in load is adjusted through the AVC63-4A STAB
control. Clockwise rotation increases the response time.
This decreases the amount of voltage overshoot which
increases stability. Counterclockwise rotation decreases
the response time. This increases the amount of voltage
overshoot which decreases stability.
Publication
9285800991
For terms of service relating to this product and software, see the Commercial Terms of Products and Servicesdocument available at www.basler.com/terms.
Revision
C
Instruction
Date
09/12
Copyright
2012
FUSES
The AVC63-4A is protected by an internal fuse illustrated in
Figure 1. A spare fuse, mounted on the back of the internal
fuse, is provided with the AVC63-4A.
To protect your wiring from faults before the regulator,
fuses with high interruption capability should be installed
according to the interconnection diagrams (Figure 4, Figure
5, and Figure 6).
OPERATING PROCEDURES
Caution
Meggers and high-potential test equipment must
not be used. Incorrect use of such equipment could
damage the regulator.
The following procedures provide instructions for adjusting
the AVC63-4A. Certain generator system problems are
included along with suggested solutions.
Complete the Preliminary Setup procedure before
proceeding with the System Startup procedure.
Preliminary Setup
1. Verify that the AVC63-4A specifications conform to the
requirements of the generator system.
2. Configure the regulator connections as follows:
a. If a remote voltage adjust rheostat will not be
used, ensure that regulator terminals 6 and 7
are shorted with a jumper.
b. If a 55 Hz corner frequency for a 60 Hz
system is desired, ensure that terminals HZ1
and HZ2 are open. If a 45 Hz corner
frequency for a 50 Hz system is desired, short
terminals HZ1 and HZ2 with a jumper.
c. For 120 Vac nominal sensing, ensure that
terminals V1 and V2 are open. For 240 Vac
sensing, short terminals V1 and V2 with a
jumper.
3. Ensure that the AVC63-4A is connected to the
generator system correctly. Connections for typical
AVC63-4A applications are shown in Figure 4, Figure
5, and Figure 6.
4. Install the fuses as described in Fuses.
5. Adjust the AVC63-4A VOLT ADJ control fully
counterclockwise. If a remote voltage adjust rheostat is
used, adjust it to the center of its rotation.
System Startup
1. Start the generator and bring it up to its rated speed.
Result: Voltage should build up. If it does not, perform field
flashing.
2. Slowly adjust the AVC63-4A VOLT ADJ clockwise until
Result: Voltage should build to the rated value. If the
voltage does not build to the rated value, check the
generator for a short-circuit or excessive load.
3. Check regulator operation under normal operating and
Result: Voltage regulation should be better than ±1.0%
over the range of no-load to full-load. Voltage reduction
under load may be due to a speed change from no-load to
full-load. This may cause the frequency compensation
circuit to reduce the voltage at lower frequencies.
OPERATIONAL TEST
1. Connect the AVC63-4A as shown in Figure 7 but do
2. Adjust the AVC63-4A VOLT ADJ control and/or remote
3. Apply 120 Vac, 50/60 Hz power to the AVC63-4A. The
4. Slowly adjust the AVC63-4A VOLT ADJ control
5. Rotate the STAB ADJ control fully clockwise. Now
DRAWING NOTES
The following notes apply to the interconnection diagrams
(Figure 4, Figure 5, and Figure 6) and the operational test
diagram (Figure 7).
1. If an external rheostat is not used, short terminals 6
2. Short terminals HZ1 and HZ2 for 50 Hz operation and
3. Item is not supplied by Basler Electric.
4. For 120 Vac nominal sensing voltage, make no
Note
The Preliminary Setup procedure must be
performed before proceeding with system startup.
All voltage readings are to be taken with an
average reading voltmeter.
5. Select fuses with a high interrupting capacity. If a
the generator output voltage reaches the nominal
value. If used, adjust the remote voltage adjust
rheostat to set the generator voltage to the desired
level.
loading conditions.
not apply power yet. Ensure that the light bulb is rated
for 120 Vac and less than 100 W.
voltage adjust rheostat fully counterclockwise. Adjust
the AVC63-4A STAB control fully counterclockwise.
light bulb should be off.
clockwise. At the regulation point, the light bulb should
illuminate. Small adjustments above and below this
level should cause the light bulb to turn off and on.
Note that the light bulb turns on and off rapidly.
adjust the VOLT ADJ control above and below the
regulation point. The light bulb should still turn off and
on, but the transition from off to on and on to off should
be much slower.
and 7.
leave terminals HZ1 and HZ2 open for 60 Hz
operation.
connection to terminals V1 and V2. For 240 Vac
nominal sensing voltage, short terminals V1 and V2
together.
glass-type fuse is used, enclose it for safety.
Publication
9285800991
For terms of service relating to this product and software, see the Commercial Terms of Products and Servicesdocument available at www.basler.com/terms.
Revision
C
Instruction
Date
09/12
Page
2 of 4