WIKA IPT-1 Operating Instructions Manual

Operating Instructions
Process pressure transmitter IPT-1* Vers. 3.0 - metalic
sensor
Probus PA
Contents
1 About this document
4
1.2 Target group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
1.3 Symbolism used . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
2 For your safety
2.1 Authorised personnel . . . . . . . . . . . . . . . . . . . . . . . .
5
2.2 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
2.3 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . .
5
2.4 General safety instructions . . . . . . . . . . . . . . . . . . . .
5
2.5 Safety approval markings and safety tips . . . . . . . . . .
6
2.6 CE conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6
2.7 Fulllment of NAMUR recommendations . . . . . . . . . .
6
2.8 Safety instructions for Ex areas . . . . . . . . . . . . . . . . .
6
2.9 Safety instructions for oxygen applications . . . . . . . . .
6
3 Product description
3.1 Conguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
3.2 Principle of operation . . . . . . . . . . . . . . . . . . . . . . . .
8
3.3 Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8
3.4 Packaging, transport and storage . . . . . . . . . . . . . . .
9
4 Mounting
4.1 General instructions . . . . . . . . . . . . . . . . . . . . . . . . .
10
4.2 Mounting instructions . . . . . . . . . . . . . . . . . . . . . . . .
12
4.3 Mounting steps. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12
5 Connecting to power supply
5.1 Preparing the connection . . . . . . . . . . . . . . . . . . . . .
13
5.2 Connection procedure. . . . . . . . . . . . . . . . . . . . . . . .
14
5.3 Wiring plan, single chamber housing . . . . . . . . . . . . .
15
16
5.5 Switch on phase. . . . . . . . . . . . . . . . . . . . . . . . . . . .
18
6 Set up with the indicating and adjustment module
6.1 Short description . . . . . . . . . . . . . . . . . . . . . . . . . . .
20
6.2 Insert indicating and adjustment module. . . . . . . . . . .
20
6.3 Adjustment system . . . . . . . . . . . . . . . . . . . . . . . . . .
22
6.4 Setup procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . .
23
6.5 Menu schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . .
32
6.6 Saving the parameter adjustment data . . . . . . . . . . . .
34
7 Setup with PDM
7.1 Parameter adjustment with PDM . . . . . . . . . . . . . . . .
35
8 Maintenance and fault rectication
8.1 Maintenance, cleaning . . . . . . . . . . . . . . . . . . . . . . .
36
8.2 Remove interferences . . . . . . . . . . . . . . . . . . . . . . . .
36
2 Process pressure transmitter IPT-1* Vers. 3.0 - metalic sensor Probus PA
Contents
31544-EN-081211
8.3 Instrument repair . . . . . . . . . . . . . . . . . . . . . . . . . . .
38
9 Dismounting
9.1 Dismounting steps . . . . . . . . . . . . . . . . . . . . . . . . . .
39
9.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
39
10 Supplement
10.1 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
40
10.2 Information on Probus PA . . . . . . . . . . . . . . . . . . . .
46
10.3 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
51
Supplementary documentation
Information:
Supplementary documents appropriate to the ordered version come with the delivery. You can nd them listed in chapter "Product
description".
Instructions manuals for accessories and replacement parts
Tip:
To ensure reliable setup and operation of your IPT-1* Vers. 3.0, we oer accessories and replacement parts. The associated documents are:
l Operating instructions manual "External indicating and adjustment
unit"
Process pressure transmitter IPT-1* Vers. 3.0 - metalic sensor • Probus PA 3
Contents
31544-EN-081211
1 About this document
1.1 Function
This operating instructions manual provides all the information you need for mounting, connection and setup as well as important instructions for maintenance and fault rectication. Please read this information before putting the instrument into operation and keep this manual accessible in the immediate vicinity of the device.
1.2 Target group
This operating instructions manual is directed to trained qualied personnel. The contents of this manual should be made available to these personnel and put into practice by them.
1.3 Symbolism used
Information, tip, note
This symbol indicates helpful additional information.
Caution: If this warning is ignored, faults or malfunctions can result. Warning: If this warning is ignored, injury to persons and/or serious damage to the instrument can result. Danger: If this warning is ignored, serious injury to persons and/or destruction of the instrument can result.
Ex applications
This symbol indicates special instructions for Ex applications.
l List
The dot set in front indicates a list with no implied sequence.
à Action
This arrow indicates a single action.
1 Sequence
Numbers set in front indicate successive steps in a procedure.
4 Process pressure transmitter IPT-1* Vers. 3.0 - metalic sensor Probus PA
1 About this document
31544-EN-081211
2 For your safety
2.1 Authorised personnel
Mount and set up the pressure transmitter only if you know the applicable national regulations and have the appropriate qualication. You must be aquainted with the regulations and instructions for hazardous areas, measurement and control technology as well as electrical circuits because the pressure transmitter is "electrical equipment" according to EN 50178. Depending on the application conditions, it is necessary that you have appropriate knowledge, e.g. concerning corrosive products or high pressure.
2.2 Appropriate use
IPT-1* Vers. 3.0 is a pressure transmitter for measurement of gauge pressure, absolute pressure and vacuum.
You can nd detailed information on the application range in chapter
"Product description".
Operational reliability is ensured only if the instrument is properly used according to the specications in the operating instructions manual as well as possible supplementary instructions.
For safety and warranty reasons, any invasive work on the device beyond that described in the operating instructions manual may be carried out only by personnel authorised by the manufacturer. Arbitrary conversions or modications are explicitly forbidden.
2.3 Warning about misuse
Inappropriate or incorrect use of the instrument can give rise to application-specic hazards, e.g. vessel overll or damage to system components through incorrect mounting or adjustment.
2.4 General safety instructions
This is a high-tech instrument requiring the strict observance of standard regulations and guidelines. The user must take note of the safety instructions in this operating instructions manual, the country­specic installation standards as well as all prevailing safety regulations and accident prevention rules.
The instrument must only be operated in a technically awless and reliable condition. The operator is responsible for trouble-free operation of the instrument.
During the entire duration of use, the user is obliged to determine the compliance of the required occupational safety measures with the current valid rules and regulations and also take note of new regulations.
Process pressure transmitter IPT-1* Vers. 3.0 - metalic sensor Probus PA 5
2 For your safety
31544-EN-081211
2.5 Safety approval markings and safety tips
The safety approval markings and safety tips on the device must be observed.
2.6 CE conformity
This device fullls the legal requirements of the applicable EC guidelines. By attaching the CE mark, VEGA provides a conrmation of successful testing.
2.7 Fulllment of NAMUR recommendations
With respect to interference resistance and emitted interference, the NAMUR recommendation NE 21 is fullled.
With respect to compatibility, the NAMUR recommendation NE 53 is
fullled. This applies also to the corresponding indicating and adjustment components. WIKA instruments are generally upward and downward compatible.
l Sensor software for DTM IPT-1* Vers. 3.0 HART, PA or FF l DTM IPT-1* Vers. 3.0 for adjustment software PACTware l Indicating and adjustment module for sensor software
The parameter adjustment of the basic sensor functions is indepen­dent of the software version. The range of available functions depends on the respective software version of the individual components.
The software version of IPT-1* Vers. 3.0 can be determined as follows:
l via PACTware l on the type label of the electronics l via the indicating and adjustment module
2.8 Safety instructions for Ex areas
Please note the Ex-specic safety information for installation and operation in Ex areas. These safety instructions are part of the operating instructions manual and come with the Ex-approved instruments.
2.9 Safety instructions for oxygen applications
For instruments in oxygen applications the special instructions in chapters "Storage and transport", "Mounting" as well as "Technical data" under "Process conditions"must be noted. Furthermore the valid national regulations, implementation instructions and memorandums of the BG (professional assoc.) must be noted.
6 Process pressure transmitter IPT-1* Vers. 3.0 - metalic sensor Probus PA
2 For your safety
31544-EN-081211
3 Product description
3.1 Conguration
The scope of delivery encompasses:
l IPT-1* Vers. 3.0 process pressure transmitter l Documentation
- this operating instructions manual
- Operating instructions manual "Indicating and adjustment
module" (optional)
- Supplementary instructions manual "Plug connector for con- tinuously measuring sensors" (optional)
- Ex-specic "Safety instructions" (with Ex-versions)
- if necessary, further certicates
Instruments in the version "Oil and grease-free for oxygen ap- plications" are equipped with a supplementary label. The sup-
plementary label contains instructions on oil and grease-free parts of the instrument.
IPT-1* Vers. 3.0 consists of the following components:
l Process tting with measuring cell l Housing with electronics, optionally available with plug connector l Housing cover, optionally available with indicating and adjustment
module
The components are available in dierent versions.
1
2
3
Fig. 1: Example of a IPT-1* Vers. 3.0 with manometer connection G½ A according to EN 837 and Alu housing
1 Housing cover with integrated indicating and adjustment module (optional) 2 Housing with electronics 3 Process tting with measuring cell
The type label contains the most important data for identication and use of the instrument:
l Article number
Scope of delivery
Supplementary label
"Oil and grease-free for oxygen applications"
Components
Type label
Process pressure transmitter IPT-1* Vers. 3.0 - metalic sensor Probus PA 7
3 Product description
31544-EN-081211
l Serial number l Technical data
3.2 Principle of operation
IPT-1* Vers. 3.0 is a pressure transmitter for measurement of overpressure, absolute pressure or vacuum. Measured products are gases, vapours and liquids in measuring ranges up to 4000 bar (400 MPa); with front-flush version also viscous liquids in measuring ranges up to 600 bar (60 MPa).
The process pressure acts on the sensor element via the stainless steel diaphragm. The process pressure causes a resistance change which is converted into a corresponding output signal and outputted as measured value.
1)
Power supply via the Probus DP/PA segment coupler. A two-wire cable according to Probus specication serves as carrier of both power and digital data transmission for multiple sensors. The instrument prole of IPT-1* Vers. 3.0 corresponds to prole specifi- cation version 3.0.
The GSD (instrument master les) and bitmap les necessary for planning your Probus-DP-(PA) communication network are available from the download section on the WIKA homepage
www.wika.com under "Service". There you can also nd the appropriate certicates. In a PDM environment, an EDD (Electronic Device Description) is also required to enable the full range of sensor functions (also available as a download).A CD with the appropriate les can be ordered via e-mail under info@de.WIKA.com or by phone from one of the WIKA agencies.
The backlight of the indicating and adjustment module is powered by the sensor. Prerequisite is a certain level of operating voltage.
The data for power supply are specied in chapter "Technical data".
This function is available at a later date for instruments with StEx, WHG or ship approval as well as country-specic approvals such as those according to FM or CSA.
3.3 Operation
IPT-1* Vers. 3.0 can be adjusted with dierent adjustment media:
l with indicating and adjustment module l the Simatic adjustment program PDM
The entered parameters are generally saved in IPT-1* Vers. 3.0, optionally also in the indicating/adjustment module.
1)
Measuring ranges up to 16 bar: piezoresistive sensor element with internal transmission liquid, with measuring ranges up to 25 bar: Strain gauge (DMS) sensor element on the rear of the stainless steel diaphragm (dry).
Application area
Functional principle
Power supply and bus
communication
GSD/EDD
8 Process pressure transmitter IPT-1* Vers. 3.0 - metalic sensor Probus PA
3 Product description
31544-EN-081211
3.4 Packaging, transport and storage
Your instrument was protected by packaging during transport. Its capacity to handle normal loads during transport is assured by a test according to DIN EN 24180.
The packaging of standard instruments consists of environment­friendly, recyclable cardboard. For special versions, PE foam or PE foil is also used. Dispose of the packaging material via specialised recycling companies.
Instruments for oxygen applications are sealed in PE foil and provided with a label "Oxygen! Use no Oil". Remove this foil just before mounting the instrument! See instruction under "Mounting".
Transport must be carried out under consideration of the notes on the transport packaging. Nonobservance of these instructions can cause damage to the device.
The delivery must be checked for completeness and possible transit damage immediately at receipt. Ascertained transit damage or concealed defects must be appropriately dealt with.
Up to the time of installation, the packages must be left closed and stored according to the orientation and storage markings on the outside.
Unless otherwise indicated, the packages must be stored only under the following conditions:
l Not in the open l Dry and dust free l Not exposed to corrosive media l Protected against solar radiation l Avoiding mechanical shock and vibration
l Storage and transport temperature see chapter "Supplement -
Technical data - Ambient conditions"
l Relative humidity 20 85 %
Packaging
Transport
Transport inspection
Storage
Storage and transport
temperature
Process pressure transmitter IPT-1* Vers. 3.0 - metalic sensor Probus PA 9
3 Product description
31544-EN-081211
4 Mounting
4.1 General instructions
Make sure that all parts of the instrument in contact with the measured product, especially the sensor element, process seal and process tting, are suitable for the existing process conditions such as process pressure, process temperature as well as t he chemical properties of the medium.
You can nd the specications in chapter "Technical data" in the or on the type label.
Caution:
After removal of the diaphragm protective cover, the diaphragm must not be pressed.
Select an installation position you can easily reach for mounting and connecting as well as later retrotting of an indicating and adjustment module. The housing can be rotated by 330° without the use of any tools. You can also install the indicating and adjustment module in four dierent positions (each displaced by 90°).
Use the recommended cables (see chapter "Connecting to power supply") and tighten the cable gland.
You can give your instrument additional protection against moisture penetration by leading the connection cable downward in front of the cable entry. Rain and condensation water can thus drain off. This applies mainly to outdoor mounting as well as installation in areas where high humidity is expected (e.g. through cleaning processes) or on cooled or heated vessels.
Fig. 2: Measures against moisture penetration
Suitability for process conditions
Diaphragm pro­tection
Mounting position
Moisture
10 Process pressure transmitter IPT-1* Vers. 3.0 - metalic sensor Probus PA
4 Mounting
31544-EN-081211
The ventilation of the measuring cell is realised by a lter element in the socket of the electronics housing. The ventilation of the electronics housing is realised via an additional lter element around the cable glands.
2)
1
2
Fig. 3: Position of the lter elements 1 Filter element for ventilation of the measuring cell 2 Filter element for ventilation of the electronics housing
Information:
Make sure that the lter elements are always free of buildup during operation. A pressure washer must not be used for cleaning.
Higher process temperatures mean often also higher ambient temperatures.
1
2
Fig. 4: Temperature ranges 1 Process temperature 2 Ambient temperature
Make sure that the upper temperature limits for the environment of electronics housing and connection cable specied in chapter "Technical data" are not exceeded.
2)
With previous instrument versions, ventilation and pressure compensation were carried out together via a lter element.
Ventilation and pressure compensation
Temperature limits
Process pressure transmitter IPT-1* Vers. 3.0 - metalic sensor Probus PA 11
4 Mounting
31544-EN-081211
Danger:
Instruments in the version "Oil and grease free for oxygen" should be unpacked just before mounting. After the protective cover of the process tting has been removed, the label "O" on the process tting is visible. Contamination by oil, grease and dirt should be avoided. Danger of explosion!
4.2 Mounting instructions
IPT-1* Vers. 3.0 functions in any installation position. It is mounted according to the same directives as a manometer (DIN EN 839-2).
3)
Information:
We recommend using lock ttings, measuring instrument holders and siphons from the line of WIKA accessories.
4.3 Mounting steps
To mount IPT-1* Vers. 3.0, a welded socket is necessary. Use components from the line of WIKA mounting accessories.
à Note the applicable we lding standards (segment welding proce-
dure) when welding the socket.
Use the seal corresponding to the instrument:
l Process tting GD: Tesnit seal in front of the thread
- or -
Seal the thread with teon, hemp or a similar resistant seal material:
l Process tting GN
à Screw IPT-1* Vers. 3.0 into the welded socket. Tighten the
hexagon on the process tting with a suitable wrench. Wrench size, see chapter "Dimensional drawings".
Warning:
The housing must not be used to screw the instrument in! Applying tightening force can damage internal parts of the housing.
3)
Probable position correction see chapter "Setup steps".
Oxygen applica­tions
Mounting position
Welding the socket
Sealing/Screwing in
12 Process pressure transmitter IPT-1* Vers. 3.0 - metalic sensor Probus PA
4 Mounting
31544-EN-081211
5 Connecting to power supply
5.1 Preparing the connection
Always keep in mind the following safety instructions:
l Connect only in the complete absence of line voltage l If overvoltage surges are expected, overvoltage arresters should
be installed according to Probus specications
In hazardous areas you should take note of the appropriate
regulations, conformity and type approval certicates of the sensors and power supply units.
Power is supplied via a P robus DP/PA segment coupler. The power supply range can dier depending on the instrument version. The exact range is stated in the "Technical data".
IPT-1* Vers. 3.0 is connected with screened cable according to the Probus specication. Power supply and digital bus signal are carried
over the same two-wire connection cable.
Use cable with round cross-section. A cable outer diameter of 5 … 9 mm (0.2 0.35 in) ensures the seal eect of the cable gland. If you are
using cable with a dierent diameter or cross-section, exchange the seal or use a suitable cable gland.
Please make sure that your installation is carried out according to the Probus specication. In particular, make sure that the termination of
the bus is done with appropriate terminating resistors.
In systems with potential equalisation, connect the cable screen directly to ground potential at the power supply unit, in the connection box and at the sensor. The screen in the sensor must be connected directly to the internal ground terminal. The ground terminal outside on the housing must be connected to the potential equalisation (low impedance).
In systems without potential equalisation, connect the cable screen directly to ground potential at the power supply unit and at the sensor. In the connection box or T-distributor, the screen of the short stub to the sensor must not be connected to ground potential or to another cable screen. The cable screens to the power supply unit and to the next distributor must be connected to each other and also connected to ground potential via a ceramic capacitor (e.g. 1 nF, 1500 V). The low frequency potential equalisation currents are thus suppressed, but the protective eect against high frequency interference signals remains.
The total capacitance of the cable and of all capacitors must not exceed 10 nF in Ex applications.
Note safety instructions
Take note of
safety instruc­tions for Ex ap­plications
Select power supply
Selecting connection
cable
Cable screening and grounding
Process pressure transmitter IPT-1* Vers. 3.0 - metalic sensor Probus PA 13
5 Connecting to power supply
31544-EN-081211
Take note of the corresponding installation regulations for Ex applications. In particular, make sure that no potential equalisation currents ow over the cable screen. In case of grounding on both sides this can be achieved by the use of a capacitor or a separate potential equalisation.
5.2 Connection procedure
Proceed as follows:
1 Unscrew the housing cover 2 If an indicating and adjustment module is installed, remove it by
turning it slightly to the left.
3 Loosen compression nut of the cable entry 4 Remove approx. 10 cm (4 in) of the cable mantle, strip approx.
1 cm (0.4 in) insulation from the ends of the individual wires 5 Insert the cable through the cable gland into the sensor 6 Lift the opening levers of the terminals with a screwdriver (see
following illustration) 7 Insert the wire ends into the open terminals according to the wiring
plan
Fig. 5: Connection steps 6 and 7
8 Press down the opening levers of the terminals, you will hear the
terminal spring closing
Select connec­tion cable for Ex applications
14 Process pressure transmitter IPT-1* Vers. 3.0 - metalic sensor Probus PA
5 Connecting to power supply
31544-EN-081211
9 Check the hold of the wires in the terminals by lightly pulling on
them
10 Connect the screen to the internal ground terminal, connect the
outer ground terminal with potential equalisation
11 Tighten the compression nut of the cable entry. The seal ring must
completely encircle the cable
12 Screw the housing cover on
The electrical connection is nished.
5.3 Wiring plan, single chamber housing
The following illustrations apply to the non-Ex as well as to the Ex-ia
version.
1 2 3
5
4
5
5
4
4
Fig. 6: Material versions, single chamber housing
1 Plastic
2 Aluminium
3 Stainless steel
Housing overview
Process pressure transmitter IPT-1* Vers. 3.0 - metalic sensor Probus PA 15
5 Connecting to power supply
31544-EN-081211
I²C
Display
1 2 5 6 7 8
3
4
1
2
Fig. 7: Electronics and connection compartment, single chamber housing 1 Plug connector for service 2 Spring-loaded terminals for connection of the external indicating and
adjustment module
3 Ground terminal for connection of the cable screen 4 Spring-loaded terminals for voltage supply
I2C
Display
1
1 2 5
6 7 8
Fig. 8: Wiring plan, single chamber housing 1 Voltage supply/Signal output
5.4 Wiring plan, double chamber housing
The following illustrations apply to the non-Ex as well as to the Ex-ia version.
Electronics and connec­tion compartment
Wiring plan
16 Process pressure transmitter IPT-1* Vers. 3.0 - metalic sensor Probus PA
5 Connecting to power supply
31544-EN-081211
1 2 3
4
5
Fig. 9: Double chamber housing
1 Housing cover, connection compartment
2 Blind stopper or plug M12 x 1 for the external indicating and adjustment
module (optional)
3 Housing cover, electronics compartment
4 Filter element for air pressure compensation
5 Cable entry or plug
1
3
2
Display
1 2 5 6 7 8
I²C
Fig. 10: Electronics compartment, double chamber housing
1 Plug connector for service
2 Internal connection cable to the connection compartment
3 Terminals for the external indicating and adjustment module
Housing overview
Electronics compart-
ment
Process pressure transmitter IPT-1* Vers. 3.0 - metalic sensor Probus PA 17
5 Connecting to power supply
31544-EN-081211
Loading...
+ 39 hidden pages