WIKA A-IAI-1, A-AI-1 Operating Instructions Manual

Operating instructions Betriebsanleitung
DE
EN
Attachable indicator model A-IAI-1
Aufsteckanzeige Typ A-IAI-1
DE
EN
14016825.03 12/2018 EN/DE
Operating instructions model A-IAI-1
Page 3 - 26
Betriebsanleitung Typ A-IAI-1
Seite 27 - 51
WIKA operating instructions attachable indicator model A-IAI-1
2
© 2012 WIKA Alexander Wiegand SE & Co. KG All rights reserved. / Alle Rechte vorbehalten. WIKA
®
is a registered trademark in various countries.
WIKA
®
ist eine geschützte Marke in verschiedenen Ländern.
Prior to starting any work, read the operating instructions! Keep for later use!
Vor Beginn aller Arbeiten Betriebsanleitung lesen! Zum späteren Gebrauch aufbewahren!
EN
WIKA operating instructions attachable indicator model A-IAI-1
3
14016825.03 12/2018 EN/DE
Contents
Contents
1. General information 4
2. Safety 5
2.1 Intended use 6
2.2 Personnel qualication 6
2.3 Additional safety instructions for instruments per ATEX 7
2.4 Special hazards 8
2.5 Labelling / Safety marks 10
3. Specications 11
4. Design and function 13
4.1 Description 13
4.2 Scope of delivery 13
5. Transport, packaging and storage 14
5.1 Transport 14
5.2 Packaging 14
5.3 Storage 14
6. Commissioning, operation 15
6.1 Electrical connection 15
6.2 Pin assignment 15
6.3 Conguration of the display 17
7. Maintenance and cleaning 21
7.1 Maintenance 21
7.2 Cleaning 21
8. Faults 21
9. Dismounting, return and disposal 23
9.1 Disassembly 23
9.2 Returns 23
9.3 Disposal 24 Appendix 1: EU Declaration of conformity 25
Declarations of conformity can be found online at www.wika.com.
EN
WIKA operating instructions attachable indicator model A-IAI-1
4
14016825.03 12/2018 EN/DE
1. General information
The model A-IAI-1 attachable indicator described in the operating instructions has been manufactured using state-of-the-art technology. All components are subject to stringent quality and environmental criteria
during production. Our management systems are certied to ISO 9001
and ISO 14001.
These operating instructions contain important information on handling the instrument. Working safely requires that all safety instructions and work instructions are observed.
Observe the relevant local accident prevention regulations and general safety regulations for the instrument's range of use.
The operating instructions are part of the product and must be kept in the immediate vicinity of the instrument and readily accessible to skilled personnel at any time.
Skilled personnel must have carefully read and understood the operating instructions prior to beginning any work.
The manufacturer's liability is void in the case of any damage caused by using the product contrary to its intended use, non-compliance with these
operating instructions, assignment of insuciently qualied skilled person­nel or unauthorised modications to the instrument.
The general terms and conditions contained in the sales documentation shall apply.
Subject to technical modications.
Further information:
- Internet address: www.wika.de / www.wika.com
- Relevant data sheet: AC 80.07
- Application consultant: Tel.: +49 9372 132-0
Fax: +49 9372 132-406
E-mail: info@wika.com
1. General information
EN
WIKA operating instructions attachable indicator model A-IAI-1
5
14016825.03 12/2018 EN/DE
Explanation of symbols
WARNING!
... indicates a potentially dangerous situation that can result in serious injury or death, if not avoided.
CAUTION!
... indicates a potentially dangerous situation that can result in light injuries or damage to equipment or the environment, if not avoided.
Information
... points out useful tips, recommendations and information for
ecient and trouble-free operation.
DANGER!
... identies hazards caused by electric power. Should the
safety instructions not be observed, there is a risk of serious or fatal injury.
WARNING!
... indicates a potentially dangerous situation in the hazardous area that can result in serious injury or death, if not avoided.
2. Safety
WARNING!
Before installation, commissioning and operation, ensure that the appropriate instrument has been selected in terms of
measuring range, design and specic measuring conditions.
Non-observance can result in serious injury and/or damage to the equipment.
Further important safety instructions can be found in the individual chapters of these operating instructions.
1. General information / 2. Safety
EN
WIKA operating instructions attachable indicator model A-IAI-1
6
14016825.03 12/2018 EN/DE
2. Safety
2.1 Intended use
The model A-IAI-1 attachable indicator is suitable for insertion between an intrinsically-safe transmitter and the corresponding output connector (angular connector).
The instrument has been designed and built solely for the intended use described here, and may only be used accordingly.
The technical specications contained in these operating instructions must
be observed. Improper handling or operation of the instrument outside of its
technical specications requires the instrument to be taken out of service
immediately and inspected by an authorised WIKA service engineer.
Handle electronic precision measuring instruments with the required care
(protect from humidity, impacts, strong magnetic elds, static electricity and
extreme temperatures, do not insert any objects into the instrument or its openings). Plugs and sockets must be protected from contamination. If the instrument is transported from a cold into a warm environment, the formation of condensation may result in instrument malfunction. Before putting it back into operation, wait for the instrument temperature and the room temperature to equalise. The manufacturer shall not be liable for claims of any type based on opera­tion contrary to the intended use.
2.2 Personnel qualication
WARNING!
Risk of injury should qualication be insucient!
Improper handling can result in considerable injury and damage to equipment.
The activities described in these operating instructions may only be carried out by skilled personnel who have the quali­cations described below.
Keep unqualied personnel away from hazardous areas.
EN
WIKA operating instructions attachable indicator model A-IAI-1
7
14016825.03 12/2018 EN/DE
2. Safety
Skilled electrical personnel
Skilled electrical personnel are understood to be personnel who, based on their technical training, know-how and experience as well as their knowledge
of country-specic regulations, current standards and directives, are capable
of carrying out work on electrical systems and independently recognising and avoiding potential hazards.
The skilled electrical personnel have been specically trained for the work
environment they are working in and know the relevant standards and regula­tions. The skilled electrical personnel must comply with current legal accident prevention regulations.
2.3 Additional safety instructions for instruments per ATEX
WARNING!
Non-observance of these instructions and their contents may result in the loss of explosion protection.
Electrical specications in accordance with the EC-type examination certicate.
Input circuit:
In intrinsically-safe ignition protection type Ex ia/ib IIC/IIB.
Only for connection to certied intrinsically-safe circuits.
Maximum values:
U
i
= 28 V
I
i
= 100 mA
P
i
= 1,200 mW
Maximum eective internal capacitance C
i
< 13 nF
The maximum eective internal inductance is negligibly small.
WARNING! Special conditions for all variants:
1. Modications or repairs of the device may not be performed
by the customer. For maintenance or repair the device must be sent to the manufacturer.
2. The opening of the device is only permitted outside the hazardous area.
EN
WIKA operating instructions attachable indicator model A-IAI-1
8
14016825.03 12/2018 EN/DE
2. Safety
WARNING! Special conditions for all variants:
3. The setting of the internal keys may be performed only by trained personnel.
4. The devices meet the requirements of intrinsic safety only after angle plugs, which are appropriate to the required lP protection degree, are connected. The devices shall be installed in places that are protected against external damage.
5. The devices back side may not be cleaned with a cloth or other means, which can generate an electrostatic charge.
2.4 Special hazards
WARNING!
Observe the information given in the applicable type examina-
tion certicate and the relevant country-specic regulations for installation and use in hazardous areas (e.g. IEC 60079-14,
NEC, CEC). Non-observance can result in serious injury and/or damage to equipment.
DANGER!
Danger of death caused by electric current Upon contact with live parts, there is a direct danger of death. The instrument may only be installed and mounted by skilled personnel.
WARNING!
Do not use this instrument in safety or Emergency Stop devices. Incorrect use of the instrument can result in injury or material damage.
This instrument has been designed and tested in accordance with the relevant safety regulations for electronic measuring instruments. The trouble-free operation and reliability of the instrument can only be guaranteed if the general safety measures and the
instrument-specic safety instructions given in this manual are
followed.
EN
WIKA operating instructions attachable indicator model A-IAI-1
9
14016825.03 12/2018 EN/DE
2. Safety
WARNING!
Observe the working conditions in accordance with chapter
3 "Specications".
Prior to opening the instrument, disconnect it from the power supply. Take care that, in tting the instrument and connec­tions, all components are protected against direct contact.
Observe standard regulations and safety rules for electrical, low-power and high-power systems, especially any country-
specic safety regulations (for example VDE 0100).
Design the wiring particularly carefully when connecting to other devices (e.g. a PC). Under certain circumstances, internal connections in third-party devices (e.g. GND connected to the safety earth) can lead to impermissible voltages.
If the connected cable is longer than 30 metres, or it runs outside the building, an additional and suitable overvoltage protection should be provided.
The safety of the operator may be endangered if, for example:
there is visible damage to the instrument.
the instrument is not working as specied.
the instrument has been stored under unsuitable conditions for an
extended period of time. If there is any doubt, please return the instrument to the manufacturer for repair or maintenance.
EN
WIKA operating instructions attachable indicator model A-IAI-1
10
14016825.03 12/2018 EN/DE
2. Safety
2.5 Labelling/Safety marks
2.5.1 Product label
2.5.2 Explanation of symbols
Before mounting and commissioning the instrument, ensure you read the operating instructions!
Input current
Date of manufacture
Serial no.
Order code
EN
WIKA operating instructions attachable indicator model A-IAI-1
11
14016825.03 12/2018 EN/DE
3. Specications
3. Specications
Attachable indicator
Display
Principle 7-segment LCD, 4-digit, character size 10 mm Indication range -1999 ... 9999 Accuracy ±0.2 % of the measuring span ±1 digit Measuring rate 5 measurements/sec
Voltage supply
Electrical connection To intrinsically-safe transmitters with 4 ... 20 mA
output and angular connector to DIN 175301­803 A.
Power supply Not required, since the attachable indicator is
powered by the 4 ... 20 mA loop Voltage drop approx. DC 3.0 ... 3.5 V (typ.) Permitted current carrying
capacity
max. 25 mA (40 mA short term)
Case
Material ABS, front window from polycarbonate Ingress protection IP 65 per EN 60529 / IEC 529
Dimensions ca. 48.5 x 48.5 x 35.5 mm (without angular
connector)
ca. 90 x 50.5 x 39.5 mm (with angular connector)
Weight approx. 80 g
Permissible ambient conditions
Operating temperature -20 ... +50 °C Storage temperature -20 ... +50 °C Relative humidity < 80 % r.h. non-condensing
Temperature eect on the
indication
0.1 % / 10 K
EN
WIKA operating instructions attachable indicator model A-IAI-1
12
14016825.03 12/2018 EN/DE
3. Specications
Safety-related maximum values
Power supply
U
i
= DC 9 ... 28 V
Short circuit current
Ii = 100 mA
Power limitation
P
i
= 1,200 mW
Maximum eective internal
capacitance
Ci < 13 nF
Maximum eective internal
inductance
negligibly small
For further specications see WIKA data sheet AC 80.07 and the order documen­tation.
WARNING!
For further important safety instructions for operation in hazard­ous areas see chapter 2.3 "Additional safety instructions for instruments per ATEX".
Dimensions in mm
EN
WIKA operating instructions attachable indicator model A-IAI-1
13
14016825.03 12/2018 EN/DE
4. Design and function
4. Design and function
4.1 Description
The model A-IAI-1 attachable indicator is a general-purpose, microproces­sor-controlled indicator for standard 4 ... 20 mA signals. It does not require its own power supply, but rather, it is powered directly from the measuring current. The display of the measured value is made on a 4-digit LCD display
with a maximum Indication range of -1999 ... 9999 digits.
The model A-IAI-1 attachable indicator is suitable for use in hazardous areas in accordance with: II 2G Ex ia IIC/IIB T4 Gb respectively II 2G Ex ib IIC/IIB T4 Gb
The A-IAI-1 has been designed for the connection of any intrinsically-safe transmitter (with 4 ... 20 mA output). The matching of the indicator range to the transmitter is made without external aids through the direct input of the upper and lower measuring range limits and the decimal point. The parameters and limit values are entered using three keys. All programmable parameters are saved in an EEProm and are retained in the event of a loss of power (for a minimum of 10 years).
The attachable indicator has its own integrated self-diagnostics, which continuously checks that the key components of the instrument are working properly. The integrated self-diagnostics, as well as the reporting of an over­range or under-range condition, ensure high operational safety.
The attachable indicator is delivered tested and fully calibrated. It is therefore
ready for operation, though it must rst be congured for the particular appli­cation. See chapter 6.3 "Conguration of the display".
4.2 Scope of delivery
The scope of delivery includes the following components:
Attachable indicator
2 mounting screws (68 mm and 75 mm)
Black prole sealing
Operating instructions
Cross-check scope of delivery with the delivery note.
EN
WIKA operating instructions attachable indicator model A-IAI-1
14
14016825.03 12/2018 EN/DE
5. Transport, packaging and storage
5. Transport, packaging and storage
5.1 Transport
Check the attachable indicator for any damage that may have been caused during transportation. Obvious damage must be reported immediately.
5.2 Packaging
Do not remove packaging until just before mounting. Keep the packaging as it will provide optimum protection during transport (e.g. change in installation site, sending for repair).
5.3 Storage
Permissible conditions at the place of storage:
Storage temperature: -20 ... +50 °C
Humidity: 0 ... 80 % r. h. (non-condensing)
Avoid exposure to the following factors:
Direct sunlight or proximity to hot objects
Mechanical vibration, mechanical shock (putting it down hard)
Soot, vapour, dust and corrosive gases
Potentially explosive environments, ammable atmospheres
Store the attachable indicator in its original packaging in a location that fulls
the conditions listed above. If the original packaging is not available, pack and store the instrument as described below:
1. Wrap the instrument in an antistatic plastic lm.
2. Place the instrument, along with shock-absorbent material, in the packag­ing.
3. If stored for a prolonged period of time (more than 30 days), place a bag containing a desiccant inside the packaging.
WARNING!
Before storing the instrument (following operation), remove any residual media. This is of particular importance if the medium is hazardous to health, e.g. caustic, toxic, carcinogenic, radioac­tive, etc.
EN
WIKA operating instructions attachable indicator model A-IAI-1
15
14016825.03 12/2018 EN/DE
6. Commissioning, operation
6. Commissioning, operation
6.1 Electrical connection
The connection of the attachable indicator is made via simply plugging it
between an existing transmitter and connector using a specic adapter
design for connectors to DIN 175301-803 A. No separate power supply is needed since the instrument is powered directly from the measuring current.
The connection and commissioning should only be carried out
by skilled, qualied personnel. An incorrect connection could
damage the indicator.
CAUTION!
Note the maximum permissible input current of 40 mA!
6.2 Pin assignment
The assignment of the angular connector is designed for the most common-
ly-used conguration for the respective input signal. Since this assignment
is not standardised, it can happen that the assignment for the connected transmitter does not match the assignment of the attachable indicator.
Standard assignment for the model A-IAI-1 angular connector
Contact no. Wiring colour Pin Female connector
1 grey
1)
display + display ­2 red connected 3 black connected 4 yellow connected
1) The wire between pin 1 and the device is blue, the wire between the device and female contact 1 is grey. Only the grey wire can be changed.
EN
WIKA operating instructions attachable indicator model A-IAI-1
16
14016825.03 12/2018 EN/DE
Pin contacts
Female connector
6. Commissioning, operation
If the transmitter to be connected does not have the negative power terminal on contact 2 and the positive power terminal is not on contact 1, then the assignment of the A-IAI-1 angular connector and the external angular connector must be matched accordingly. To do this, open the A-IAI-1 angular connector and exchange the wires from contact 1 and contact 2, so that these match the connection of the transmitter to be attached.
Now wire both contacts in the angular connector accordingly.
General information on changing the angular connector assignment
Lift out the coupling assembly using a screwdriver in the recess on the side. Change the assignment in line with the instructions for the relevant input signal.
Then snap the coupling assembly back into the cover. There are 4 dierent output orientations to choose from - each at 90° to each other. Attach the
angular connector and screw the connector together using the long bolt delivered with the unit (don't forget the seals).
In the angular connector, pin contact 2 is directly connected (1:1) with the female contact. Between pin contact 1 (+) and female contact 1 (-) is the A-IAI-1.
Pin contact 3 and 4 are also connected 1:1 with the female connec-
tor.